Loading...
HomeMy WebLinkAboutTab 2 - Filters Product Data: DDPDQD.PD001 Page: 2 of 4 Effective: 1/01/04 DD SERIES General Purpose Compressed Air Filters For Liquid Aerosol Coalescing or Dust OPERATING AND PERFORMANCE DATA – All Models Maximum oil carryover at operating conditions indicated(1) = 0.08 ppm Initial pressure drop at inlet air capacity Filtration efficiency for particles (as dust filter, approx.) 0.7 psig - Down to 1 micron 100% Initial saturated pressure drop at inlet air capacity - Down to .3 micron 99.9% (as liquid coalescing filter, approx.) 1.7 psig Maximum compressed air effective inlet pressure 232 psig Maximum pressure drop for element change 5 psig Minimum compressed air effective inlet pressure 14.5 psig Quality Class of Air at outlet of filter(3) 2 - 2 Maximum compressed air inlet temperature 151°F Oil concentration upstream of the filter between 2.5 – 12.5 ppm Minimum compressed air inlet temperature 35°F PERFORMANCE AND TECHNICAL DATA Model Capacity CFM(2) @ 100 psig Dimensions of Inlet/Outlet Connections (NPT) Net Weight (LBS.) Shipping Weight (LBS.) DD 9 DD 17 DD 32 DD 44 DD 60 DD 120 DD 150 DD 175 DD 280 DD 390 DD 520 19 36 68 93 127 254 318 371 593 827 1102 3/8 ½ ½ ¾ or 1 1 1 ½ 1 ½ 1 ½ 2 or 2 ½ 3 3 2.2 2.4 2.9 4.2 4.6 9.3 9.9 10.1 15.2 24.2 27.7 2.4 2.6 3.1 4.6 5.1 10.1 11.0 11.2 16.8 26.5 30.6 CORRECTION FACTORS Working Pressure (psig) 14.5 29 43.5 58 72.5 87 100 116 145 174 203 232 Correction Factor 0.38 0.53 0.65 0.75 0.83 0.92 1 1.06 1.2 1.31 1.41 1.5 (1) Referred to an atmospheric pressure of 14.5 psia and temperature 68°F (2) Referred to Atlas Copco Standard Reference Conditions of 100 psig inlet pressure and inlet and ambient temperature of 68°F, sea level (3) According to ISO 8573-2 in a typical installation Product Data: DDPDQD.PD001 Page: 3 of 4 Effective: 1/01/04 PD SERIES High Efficiency Compressed Air Filters For Liquid Aerosol Coalescing OPERATING AND PERFORMANCE DATA – All Models Maximum oil carryover at operating conditions indicated(1) = 0.08 ppm Initial pressure drop at inlet air capacity (approx.) 1.2 psig Filtration efficiency for particles Initial saturated pressure drop at inlet air capacity - Down to 1 micron 100% (approx.) 2.9 psig - Down to 0.01 micron 99.9% Maximum pressure drop for element change 5 psig Maximum compressed air effective inlet pressure 232 psig Quality Class of Air at outlet of filter(3) 1 - 1 Minimum compressed air effective inlet pressure 14.5 psig Maximum compressed air inlet temperature 151°F Minimum compressed air inlet temperature 35°F PERFORMANCE AND TECHNICAL DATA Model Capacity CFM(2) @ 100 psig Dimensions of Inlet/Outlet Connections (NPT) Net Weight (LBS.) Shipping Weight (LBS.) PD 9 PD 17 PD 32 PD 44 PD 60 PD 120 PD 150 PD 175 PD 280 PD 390 PD 520 19 36 68 93 127 254 318 371 593 827 1102 3/8 ½ ½ ¾ or 1 1 1 ½ 1 ½ 1 ½ 2 or 2 ½ 3 3 2.2 2.4 2.9 4.2 4.6 9.3 9.9 10.1 15.2 24.2 27.7 2.4 2.6 3.1 4.6 5.1 10.1 11.0 11.2 16.8 26.5 30.6 CORRECTION FACTORS Working Pressure (psig) 14.5 29 43.5 58 72.5 87 100 116 145 174 203 232 Correction Factor 0.38 0.53 0.65 0.75 0.83 0.92 1 1.06 1.2 1.31 1.41 1.5 (1) Referred to an atmospheric pressure of 14.5 psia and temperature 68°F (2) Referred to Atlas Copco Standard Reference Conditions of 100 psig inlet pressure and inlet and ambient temperature of 68°F, sea level (3) According to ISO 8573-2 in a typical installation