Loading...
HomeMy WebLinkAboutHM - TAB 5 - HACH WGS267 PART COUNTER-SAMPLERSPECIFICATIONS WGS267 Particle Counter and Sampler THERES ONLY ONE WAY TO BE SURE Built-in printer and a direct readout of particle counts in six size ranges make the WGS267 ideal for measuring drinking water filter performance in the pipe gallery or in the lab. Because the WGS267 is battery-powered, simply drop the sample tube into your grab sample, start the pump, and set the flow. Particle counts are then displayed automatically in a variety of formats. A speed adjustable pump system is used to draw the sample through the sensor from beakers, tanks or process streams. Flow enters directly into the sensor from the source to prevent particle contamination. A mesh inlet strainer is provided for raw water sources. A flowmeter measures the flow through the sensor. The sensor has a flow cross section of 750 x 750 microns is field-replaceable. The counter collects, displays, and prints count data in up to six (6) size ranges. The operator may select displayed data to be cumulative or differential counts per mL or counts per 100 mL. Programmable functions include sample duration, time period between sample runs, number of samples, flow rate, time, and date. The ounter buffer has a storage capacity of 250 records. Every part of this sampler/counter is rugged. Configuration and data communication are accomplished with the RS485 interface, allowing the unit to function either standalone (logging data for post analysis) or tied into a computer running the PortAll grab sampling software. The software transfers records in memory to a PC-compatible computer and creates report formats compatible with most popular spreadsheets. The WGS267 is designed for automatic particle monitoring in industrial environments. Sample from tanks, open streams, piping, and jars. Print results on-the-spot. Produce graphs, tables, and spreadsheet reports. Battery-powered Counts particles in six size ranges Built-in printer for on-site results Spreadsheet compatible data with PortAll software Specifications Fluid Sampler Type of Fluid Water Flow Rate 20120 mL/minute (100 mL/minute, typical) Maximum Pressure 20 psig Connection 0.25" tubing, quick connection Particle Counter Size Ranges/Channel 2, 3, 5, 8, 10, 15 microns (other ranges avail., specify when ordering) Light Source Laser diode Display 7-digit LED Locations 999 different location IDs Sample Time 1 second24 hours Sample Frequency 1 second24 hours Display Modes Counts, counts/mL, counts/100 mL, rate Dimensions 10" W x 12" H x 14" D Weight 15 lbs. Power 115 VAC/24VDC adapter Battery Power 3 hours, typical Ordering Information WGS267 Grab Sampling Instrument 57030-00 PortAll Software Package for Drinking Water57005-00 PortAll Software Package for Drinking Water with Modem Software Module 57005-01 For current price information, technical support and ordering assistance, contact the Hach office or distributor serving your area. Hach Company is ISO 9001 Certified In the United States, contact: HACH COMPANY P.O. Box 389 Loveland, Colorado 80539-0389 U.S.A. Telephone: 800-227-4224 Fax: 970-669-2932 Email: orders@hach.com www.hach.com International customer contact: HACH COMPANY P.O. Box 389 Loveland, Colorado 80539-0389 U.S.A. Telephone: 970-669-3050 Fax: 970-669-2932 Email: intl@hach.com www.hach.com J93 Printed in U.S.A. ' Hach Company, 1999. All rights reserved. The particle counting system shall consist of a portable sampling unit (consisting of sensor, counter electronics, internal printer, and pump), data collection software, and cleaning accessories, as called out herein, to produce a complete working system. SAMPLER. The sampling unit with above mentioned systems shall be designed into a rugged, portable shell with handle, to allow for easy set up and transport. It shall not exceed 21 pounds in weight and measure no more than 12 inches high, 10 inches in width, and 14 inches in depth. Housing material shall be made of an aluminum alloy to ensure ruggedness while minimizing weight. Sampler shall be powered by its internal battery or plugged into a 115vAC outlet. A speed adjustable pump system shall be used to draw the sample through the sensor from beakers, tanks or process streams. This system shall be capable of drawing water a minimum of three feet of head. Flow shall enter directly into the sensor from the source to prevent particle contamination. A mesh inlet strainer shall be provided for raw water sources. A flowmeter shall be provided to measure flow through the sensor. The sampler shall have a user-adjustable flow path enabling the operator to by-pass the pump, using gravity pressure only and external flow control. SENSOR. The sensor shall be a solid-state laser diode, light-blocking type with a field-replaceable cell. It shall be capable of counting particles from 2 to 700 microns in diameter, at a flow rate of 20 to 120 ml/ minute. The maximum particle concentration shall be 16,000 particles per milliliter, at 10% coincidence when operated with a 100 ml/minute flow rate. The sensor shall have a flow cross section of 750 x 750 microns and the flow cell shall be field-replaceable. COUNTER. The on-board counter shall collect, display, and print count data in up to six (6) size ranges. The operator may select displayed data to be cumulative or differential counts per ml or counts per 100 ml. Counter shall be capable of automatically completing a programmable number of multiple samples and printing the average of all runs. Counter shall be capable of calculating and printing log removal between sequential locations. Programmable functions shall include sample duration, time period between sample runs, number of samples, flow rate, time, and date. Counter buffer shall be capable of storing 250 records. SOFTWARE. Software shall be capable of transferring records in memory to a PC-compatible computer. The files created shall be in a format compatible with most popular, commercially-available spreadsheets. The software shall be run in Windows 98 and Windows NT. Software upgrades shall be supplied at no additional cost for up to one (1) year.