Loading...
HomeMy WebLinkAboutHM - TAB 4 - HACH pH - Conductivity HQHQd Digital Meters and IntelliCAL™Probes HQd Digital Meters DW = drinking water WW = wastewater municipal PW = pure water / power IW = industrial water E = environmental C = collections FB = food and beverage DATA SHEET ElectrochemistryDW WW PW IW E FB Now offering six testing parameters with standard, rugged, and ultra options. Hach’s HQd system gives maximum measurement flexibility and ease of operation with interchangeable probes and automatic parameter recognition. The full measurement suite includes IntelliCAL probes for pH, conductivity, Luminescent Dissolved Oxygen (LDO), Luminescent BOD (LBOD), ORP, and sodium. Guided Calibrations All Hach HQd Digital Meters provide an intuitive user interface with guided calibration and check standard routines to reduce calibration errors and simplify operation. Calibration status indicator and custom calibration alerts ensure accurate results. Traceability and Reporting HQd meters record probe serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log. Each measurement can be linked to sample ID, user ID, probe serial number, and more for complete traceability and regulatory reporting. Easy to Use in the Field All connections between the meter and the probe are secure and waterproof. Connectors can be color-coded for quick identification. Information is clearly displayed on one screen with back light for low light conditions. Display results can be enlarged for easier reading. 2 HQd Digital Meters continued The Hach HQ40d features three connection ports: 2 ports that allow simultaneous measurement of two different parameters using two different probes, and 1 port for USB and external power. Battery Life Remaining Sample and User ID Probe Stability Indicator Calibration Status Additional Units Displayed View Readings from Two Probes on One Screen Time and Date Four Models to Choose From • HQ40d Dual-input Multi-parameter Meter Plug-and-play with any two IntelliCAL probes to measure pH, conductivity, dissolved oxygen using LDO technology, ORP/Redox and sodium in any combination. The HQ40d meter has three connection ports—two ports for simultaneous measurement using two IntelliCAL probes and an additional port for USB connectivity and external power. Measurements can be made and viewed simultaneously or individually. Transfer the entire data log or individual readings (GLP/ISO) to PC or USB flash stick. The meter can be password-protected for accurate, tamper-proof reporting. The HQ40d meter comes with USB and A/C adapters, and a field kit including a carrying case, protective glove, and sample cups. • HQ30d Single-input Flexi-parameter Meter Plug-and-play with any one IntelliCAL probe to measure pH, conductivity, dissolved oxygen using LDO technology, ORP/Redox and sodium. The HQ30d meter has one port for measurement with one IntelliCAL probe and one port for USB connectivity and external power. Adapters and cables must be purchased separately. Quickly and easily swap IntelliCAL probes without re-calibration. The meter can be password-protected for accurate, tamper-proof reporting. A 500-result data log stores measurements, calibrations, and check standards. • HQ11d, HQ14d Single-input dedicated meters Dedicated meter/IntelliCAL probe combinations provide economical options for testing single parameters with either standard or rugged probes. The HQ11d measures two parameters: pH and ORP. The HQ14d tests conductivity which translates to resistivity, salinity and TDS as well. Detailed Screen Mode Shown Alternate large display mode also available for single and dual parameters. 3 Calibration History Stays with the Probe Each Hach IntelliCAL probe stores its calibration history and settings in the probe itself, allowing the probes to easily be transferred from meter to meter, minimizing probe replacement and calibration. The serial number is also stored in the probe to provide complete traceability, chain of custody, and regulatory reporting. Ready to Use Factory-calibrated IntelliCAL probes are ready to use, right out of the box. The meter will even alert the user when a new calibration is necessary. Three Probe Styles to Choose From • IntelliCAL Ultra Probes IntelliCAL ultra probes are designed for high performance in difficult applications. Probes are optimized for fast response time, accuracy, and precision. Refillable liquid-filled probes are non-submersible. Choice of cable lengths from one to three meters. • IntelliCAL Standard Probes IntelliCAL standard probes are waterproof for up to 24 hours at a depth of three meters (refillable liquid-filled probes are non-submersible). Choice of cable lengths from one to three meters. • IntelliCAL Rugged Probes IntelliCAL rugged probes are designed for harsh environments. These probes feature a super-tough, stainless steel body and polymer sensor shroud that is waterproof for 24 hours at a depth of 30 meters. The reinforced, steel- sheathed cables are durable, yet manageable. Choice of cable lengths available from 5 to 30 meters. IntelliCAL Probes— All with Built-in Temperature Sensors • pH Refillable Ultra Liquid-filled pH probe designed for fast response in all samples, including low-ionic strength sample types. Also measures temperature (not available in rugged style). • pH Gel-filled Combination Gel-filled pH probe also measures temperature (also available in rugged style). • pH Refillable Combination Liquid-filled pH probe also measures temperature (not available in rugged style). • Oxidation Reduction Potential/Redox Gel-filled Combination Gel-filled ORP/Redox probe also measures temperature (also available in rugged style). • Oxidation Reduction Potential/Redox Refillable Combination Liquid-filled ORP/Redox probe also measures temperature(not available in rugged style). • Dissolved Oxygen (DO) Using patented Hach Luminescent Dissolved Oxygen (LDO®) technology, this probe measures DO (mg/L), % saturation, pressure, and temperature (also available in rugged style). • LBOD By integrating a stirrer into the LDO probe, this probe will comply with requirements of the USEPA-based BOD5 and CBOD testing. Patented LDO technology provides fast calibration and stabilization throughout the BOD test. • Sodium Ion Selective Electrode Refillable Combination Liquid-filled sodium ISE also measures temperature (not available in rugged style). • Conductivity Four-pole graphite design probe measures conductivity (µS/cm or mS/cm), resistivity, salinity, TDS and temperature (also available in rugged style). IntelliCAL Probes Easily track measurements— “intelligent” probes store calibration info and serial numbers Polymer shroud protects sensor from impact Quickly identify probes with optional color-coded bands Standard Probe: For Laboratory Use Rugged Probe: For Field Use The LBOD system uses the breakthrough Hach Luminescent Dissolved Oxygen (LDO) probe for accurately determining DO and BOD for NPDES reporting. With no membranes to replace or fail mid-run, LBOD saves 15% in maintenance costs annually. 4 HQd Digital Meters Specifications* IntelliCAL Probes & Electrodes Specifications* Power 4 AA batteries (battery life: >200 hours) USB/DC and AC/DC power connection included (HQ40d only) USB/DC and AC/DC power connections available (HQ30d, HQ14d, HQ11d) Languages Selectable: English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian Display Display readings from one or two probes Simultaneous readings from two probes (HQ40d only) pH:pH, mV, temperature Conductivity:Conductivity, TDS, salinity, resistivity, temperature LDO:dissolved oxygen, pressure, temperature LBOD:dissolved oxygen, pressure, temperature ORP/Redox:mV, temperature Sodium:Sodium, mV, temperature Data Memory 500 results Data Storage GLP/ISO compliant reading data stored with calibration details. Calibration details and check standard readings documented as events in data log. Automatically store in “press to read” mode and interval measurement mode. Manually store in “continuous read” mode. Data Export Download via USB connection to PC or flash stick. Automatically transfer entire data log or as readings are taken. Temperature Correction/Compensation Off, automatic, and manual (auto correction is parameter dependent) Display Lock Function Continuous measurement or “press to read” mode available with averaging function for LDO measurement Automatic pH Buffer Recognition Color-coded:4.01, 7.00, 10.01 pH; IUPAC:1.679, 4.005, 7.000, 10.012, 12.45 DIN:1.09, 4.65, 9.23 User-defined custom buffer sets Keyboard External PC keyboard via USB connection Water Resistance Meter Casing:1 meter submersion for 30 minutes (IP67) Dimensions 19.7 x 9.5 cm (7.75 x 3.75 in.) Weight 335 g (0.75 lb.) Temperature Range: -10.0 to 110.0°C Resolution:0.1°C Accuracy:±0.3°C (±0.54°F) (Visit www.hach.com for exact probe operating temperatures.) pH Range:0 to 14 pH (both standard refillable and refillable ultra pH sample probes); 2 to 14 pH (standard gel-filled probe) Resolution:0.1/0.01/0.001 selectable, pH Ultra Precision: 0.01 pH units pH Precision: 0.02 pH units ORP/Redox Range:-1200mV to +1200 mV Resolution:0.1 mV Sodium Range:0.023 mg/L (1x10-6 M) to 23,000 mg/L (1 M) Na+ Resolution:2/3/4 Significant digits selectable Conductivity Range: 0.01 µS/cm to 200 mS/cm Resolution: 0.01 µS/cm (5 digits, maximum) Resistivity Range:2.5 ohm cm to 49 Mohm cm Resolution:0.1 ohm cm (5 digits, maximum) Salinity Range:0 to 42 g/kg or ‰ Resolution:0.01 ppt Total Dissolved Solids Range:0.0 to 50.0 g/L Resolution:0.1 mg/L Dissolved Oxygen (using LDO technology) Range:0.05 to 20.00 mg/L (0 to 200%) Resolution:0.01 mg/L NEW Auto Salinity Correction feature when CDC401 probe is connected (HQ40d only) BOD5/CBOD (using LBOD with LDO technology) Range:0.05 to 20.0 mg/L Resolution:0.01 mg/L Elevation Limitation 5,000 m (16,400 ft.), maximum Water Resistance Standard:IP68, waterproof for 24 hours at a depth of 3 meters (refillable liquid-filled probes are not submersible) Rugged:IP68, waterproof for 24 hours at a depth of 30 meters LBOD: IP65, waterproof for strong jets of water Cable Lengths Standard (all except LBOD):1 or 3 m (3.3 or 9.8 ft.) Rugged:5, 10, 15, or 30 m (16.4, 32.8, 49.2, or 98.4 ft.) LBOD:1.8 m (5.9 ft.) Dimensions Standard (all except LBOD):17.8 cm (7 in.) length Rugged:21.6 cm (8.5 in.) length LBOD:19.1 x 4.1 cm (7.5 x 1.6 in.) length and width Weight Standard (1 meter cable): pHC281 - 76 g (2.7 oz) pHC101 - 76 g (2.7 oz) pHC301 - 76 g (2.7 oz) MTC101 - 76 g (2.7 oz) MTC301 - 76 g (2.7 oz) ISENa381 - 76 g (2.7 oz) CDC401 - 104 g (3.7 oz) LDO101 - 127 g (4.5 oz) Rugged (5 meter cable): pHC101 - 1182 g (41.7 oz) MTC101 - 1182 g (41.7 oz) CDC401 - 1210 g (42.7 oz) LDO101 - 1232 g (43.5 oz) LBOD: 225g (7.9 oz) *Specifications subject to change without notice. 5 Ordering Information Meters Only HQ40d53000000 HQ40d Dual-input Multi-parameter Meter (includes field case and USB/AC power connections) HQ30d53000000 HQ30d Single-input Multi-parameter Meter HQ11d53000000 HQ11d Digital Portable pH/ORP Meter HQ14d53000000 HQ14d Digital Portable Conductivity Meter pH Probes Ultra Refillable Combination Standard Probe pHC28101 1 m cable pHC28103 3 m cable Gel-filled Combination Standard Probe pHC10101 1 m cable pHC10103 3 m cable Gel-filled Combination Rugged Probe pHC10105 5 m cable pHC10110 10 m cable pHC10115 15 m cable pHC10130 30 m cable Refillable Combination Standard Probe pHC30101 1 m cable pHC30103 3 m cable ORP/Redox Probes Gel-filled Combination Standard Probe MTC10101 1 m cable MTC10103 3 m cable Gel-filled Combination Rugged Probe MTC10105 5 m cable MTC10110 10 m cable MTC10115 15 m cable MTC10130 30 m cable Refillable Combination Standard Probe MTC30101 1 m cable MTC30103 3 m cable Conductivity Probes Standard Probe CDC40101 1 m cable CDC40103 3 m cable Rugged Probe CDC40105 5 m cable CDC40110 10 m cable CDC40115 15 m cable CDC40130 30 m cable Sodium ISE Probes Refillable Combination Standard Probe ISENa38101 1 m cable ISENa38103 3 m cable 6 Ordering Information continued Meter & Probe Bundles 8505900 pH Starter Kit HQ11d pH meter, gel pH probe with 1 m cable, HQd meter stand, pH Buffer Kit (500 mL), pH storage solution (500 mL), and probe stand. 8506000 Complete Water Quality Lab Kit: DO/pH/Conductivity HQ40d meter with A/C power and USB adapters, refillable pH probe with 1 m cable, conductivity probe with 1 m cable, standard LDO probe with 1 m cable, HQd meter stand, pH Buffer Kit (500 mL), pH storage solution (500 mL), conductivity standard (1000 µS/cm, 100 mL), disposable BOD bottle and stopper for calibration, and probe stand. 8506100 Conductivity Starter Kit HQ14d conductivity meter, standard conductivity probe with 1 m cable, HQd meter stand, conductivity standard (1000 µS/cm, 100 mL), and probe stand. 8505800 Advanced pH/Conductivity Kit HQ40d meter with A/C power and USB adapters, refillable pH probe with 1 m cable, conductivity probe with 1 m cable, HQd meter stand, pH Buffer Kit, 500 mL, pH storage solution (500 mL), conductivity standard (1000 µS/cm, 100 mL), probe stand. 8506200 Advanced pH/BOD Kit HQ40d meter with A/C power and USB adapters, refillable pH probe with 1 m cable, LBOD probe, HQd meter stand, pH Buffer Kit, 500 mL, pH storage solution (500 mL), disposable BOD Bottles (117/case), acrylic stoppers (25), probe stand, and BOD bottle caps (2 packages of 6). 8506300 Basic Dissolved Oxygen Kit HQ30d meter, standard LDO probe with 1 m cable, disposable BOD bottle and stopper for calibration, and HQd meter stand. 8506400 pH ultra Starter Kit HQ40d meter with A/C power and USB adapters, pH ultra probe with 1 m cable, probe stand, HQd meter stand, pH 4.01 buffer solution (color-coded red, 500 mL), pH 7.00 buffer solution (color-coded yellow, 500 mL), and pH 10.01 buffer solution (color-coded blue, 500 mL). 8506500 ORP Starter Kit HQ11d meter with A/C power and USB adapters, gel-filled standard ORP probe with 1 m cable, probe stand, HQd meter stand, ORP standard solution (500 mL). 8507000 Sodium ISE Starter Kit HQ40d meter with A/C power and USB adapters, cables, sodium ISE probe with 1 m cable, probe stand, HQd meter stand, sodium and potassium ionic strength adjustor powder pillows (pkg of 100), sodium standard solution 10 mg/L (1L), sodium standard solution 100 mg/L and (1 L), and sodium standard solution 1000 mg/L (500 mL). 8507100 ORP/pH Ultra Advanced Kit HQ40d meter with A/C power and USB adapters, standard gel-filled ORP probe with 1 m cable, pH ultra probe with 1 m cable, probe stand, HQd meter stand, ORP standard solution (500 mL), pH storage solution (500 mL), pH 4.01 buffer solution (color-coded red, 500 mL), pH 7.00 buffer solution (color-coded yellow, 500 mL), and pH 10.01 buffer solution (color-coded blue, 500 mL). 8507200 ORP/pH Basic Kit HQ40d meter with A/C power and USB adapters, standard gel-filled ORP probe with 1 m cable, standard gel-filled pH probe with 1 m cable, probe stand, HQd meter stand, ORP standard solution (500 mL), pH storage solution (500 mL), pH 4.01 buffer solution (color-coded red, 500 mL), pH 7.00 buffer solution (color-coded yellow, 500 mL), and pH 10.01 buffer solution (color-coded blue, 500 mL). LDO (Luminescent Dissolved Oxygen) Probes Standard Probe LDO10101 1 m cable LDO10103 3 m cable Rugged Probe LDO10105 5 m cable LDO10110 10 m cable LDO10115 15 m cable LDO10130 30 m cable BOD Probes LBOD10101 LDO Probe with Integrated Stirrer and 1.8 m cable HQDBOD01 BOD System; includes HQ40d meter, LBOD probe with 1.8 m cable, and meter stand 8505700 BOD System; includes HQ40d meter, LBOD probe with 1.8 m cable, meter stand, Disposable BOD Bottles (117/case), Acrylic Stoppers (25) and BOD Bottle Caps (2 packages of 6) 7 Ordering Information continued Rugged Field Kits 8505100 Rugged DO Field Kit Rugged case with durable foam insert for organization, HQ30d meter, rugged LDO probe with 5 m cable, protective glove for meter, 250 mL plastic flask for calibration, 4 containers for sample collection, polyethylene wash bottle (500 mL), box of disposable wipes, waste container, operation manual. 8505200 Rugged DO Field Kit with HQ40d Multi Meter Rugged case with durable foam insert for organization, HQ40d meter with A/C power and USB adapters, rugged LDO probe with 5 m cable, protective glove for meter, 250 mL plastic flask for calibration, 4 containers for sample collection, polyethylene wash bottle (500 mL), box of disposable wipes, waste container, operation manual. 8505300 Advanced DO/pH/Conductivity Rugged Field Kit Rugged case with durable foam insert for organization, HQ40d meter with A/C power and USB adapters, rugged LDO probe with 5 m cable, rugged pH probe with 5 m cable, rugged conductivity probe with 5 m cable, pH Buffer Singlet Packs for calibration, pH storage solution (50 mL), conductivity standard, Singlet Packs (1000 µS/cm), protective glove for meter, 250 mL plastic flask for calibration, polyethylene wash bottle (500 mL), box of disposable wipes, waste container, operation manual. 8505400 Rugged DO/pH Field Kit Rugged case with durable foam insert for organization, HQ40d meter with A/C power and USB adapters, rugged LDO probe with 5 m cable, rugged pH probe with 5 m cable, pH Buffer Singlet Packs for calibration, pH storage solution (50 mL), protective glove for meter, 250 mL plastic flask for calibration, containers for sample collection, polyethylene wash bottle (500 mL), box of disposable wipes, waste container, operation manual. 8507300 Rugged ORP Field Kit Rugged case with HQ40d meter with A/C power and USB adapters, ORP rugged gel-filled probe with 5 m cable, protective glove for meter, pH storage solution (500 mL), ORP standard solution (500 mL), electrode cleaning solution (500 mL), ORP electrode reducing solution (500 mL), Erlenmeyer flask (250 mL), polyethylene wash bottle (500 mL), sample containers (120 mL), and disposable wipes. 8507400 Rugged ORP/LDO Field Kit Rugged case with HQ40d meter with A/C power and USB adapters, rugged gel-filled ORP probe with 5 m cable, rugged LDO probe with 5 m cable, protective glove for meter, storage solution (500 mL), ORP standard solution (500 mL), electrode cleaning solution (500 mL), ORP electrode reducing solution (500 mL), 250 mL plastic flask for calibration, polyethylene wash bottle (500 mL), sample containers (120 mL), blank white labels and disposable wipes. 8507500 Rugged Environmental Conductivity/LDO Field Kit Rugged case with HQ40d meter with A/C power and USB adapters, rugged conductivity probe with 5 m cable, rugged LDO probe with 5 m cable, protective glove for meter, conductivity standard (1000 µS/cm, 491 mg/L NaCl, 100 mL), sample containers (120 mL), 250 mL plastic flask for calibration, polyethylene wash bottle (500 mL), and disposable wipes. pH Starter Kit Rugged DO/pH Field Kit Lit. No. 2599 Rev 3 F94 Printed in U.S.A. ©Hach Company, 2009. All rights reserved. In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time. For current price information, technical support, and ordering assistance, contact the Hach office or distributor serving your area. In the United States, contact: HACH COMPANY World Headquarters P.O. Box 389 Loveland, Colorado 80539-0389 U.S.A. Telephone: 800-227-4224 Fax: 970-669-2932 E-mail: orders@hach.com www.hach.com U.S. exporters and customers in Canada, Latin America, sub-Saharan Africa, Asia, and Australia/New Zealand, contact: HACH COMPANY World Headquarters P.O. Box 389 Loveland, Colorado 80539-0389 U.S.A. Telephone: 970-669-3050 Fax: 970-461-3939 E-mail: intl@hach.com www.hach.com In Europe, the Middle East, and Mediterranean Africa, contact: HACH LANGE GmbH Willstätterstraße 11 D-40549 Düsseldorf GERMANY Tel: +49 (0) 211 5288-0 Fax: +49 (0) 211 5288-143 E-mail: info@hach-lange.de www.hach-lange.com At Hach, it’s about learning from our customers and providing the right answers. It’s more than ensuring the quality of water— it’s about ensuring the quality of life. When it comes to the things that touch our lives... Keep it pure. Make it simple. Be right. 8 Ordering Information continued Accessories WM-BOD MGR Hach BOD Manager™ Software automates data entry and calculations from the HQ40d Meter and LBOD probe, providing improved productivity and data integrity for BOD testing. This stand-alone version includes: single computer license with a 2 gigabyte database, tracking up to 300 samples, HQ40d interface, one year of support and software updates, one hour of live web-based training, and training video. 5838000 Replacement LBOD Sensor Cap; includes iButton®and sensor cap 5850800 Replacement Stirrer Assembly for IntelliCAL LBOD Probe 5811200 Replacement LDO Sensor Cap; includes iButton®and sensor cap 5825900 Replacement Polymer Shroud Kit for Rugged Probes; includes protective bell and locking ring 5828610 Probe Cable Depth Markers; 5/pkg. (for rugged probes only) 4754900 Meter Stand 8506600 Probe Stand for Hach IntelliCAL Probes (except LBOD) 5828700 Protective Glove for Meter 5829400 Probe Holder (standard probes only) 5825800 Field Kit; includes hard-sided carrying case, protective glove, and 5 120 mL sample cups 5818400 Color Coded Probe Clips; includes ten clips of five different colors 5826300 USB and A/C Power Adapter Kit; adapter is not waterproof (Included with HQ40d models) 5854000 HQd Software Upgrade Kit LZV582 USB Keyboard 2960100 USB Printer; Citizen PD-24 Handy Printer, 120-220 Vac 5836000 Printer Paper for PD-24, Thermal 5/pk iButton®is a trademark of Maxim Integrated Products. Meter Stand Probe Stand for Hach IntelliCAL Probes HQd Meter USB and AC Power Adapter Kit