Loading...
HomeMy WebLinkAboutHM - TAB 2 - HACH Pocket Colorimeter - Cl2DW = drinking water WW = wastewater municipal PW = pure water / power IW = industrial water E = environmental C = collections FB = food and beverage DATA SHEET Pocket Colorimeter™ II Simple as Ever Just four buttons on the Hach Pocket Colorimeter II allow easy operation. The Read/Enter key is used when measuring sample concentrations or to confirm menu choices. The Menu key provides quick menu navigation and selection. Use the Zero/Scroll key to zero the instrument or to scroll through menu options. The Power/Backlight key turns the instrument on and toggles the display backlight for low light conditions. Waterproof, Rugged, and Light Weight The IP67 rating means the Pocket Colorimeter II will resist the elements and still function properly. A tough, impact- resistant shell protects the electronics and optics. It weighs only 0.2 kg—about a half pound. A lanyard keeps the cap attached to the colorimeter. Large Display and Data Logging The Range Indicator icon on the display of the colorimeter indicates either the instrument range or the parameter being tested. For many parameters, the instrument can measure in two different ranges. The battery icon will indicate when the batteries need to be replaced. The instrument logs the ten most recent data points and the time the measurements were made—no need to record results manually. Accurate, Reproducible Measurements The Pocket Colorimeter II offers accuracy and reproducibility comparable to expensive lab instruments, but is designed for a long working life in harsh conditions. A long-lasting LED is used as the light source, and low power requirements assure long battery life. Pre-programmed The instruments are factory programmed for one or two of more than 30 parameters. Many are based on EPA- approved methods. No manual calibration is ever required. Simply zero the instrument with a blank, insert the reacted sample, and read the result. Wavelength-specific models without factory calibration are also available for programming custom methods. Better Optics The higher absorbance range provided by the improved quality of the optical system over the previous model provides expanded ranges for several parameters— reducing the need for dilutions. Features and Benefits DW WW PW IW E FBColorimeterEach Hach Pocket Colorimeter II measures one to two parameters— many at two concentration ranges. Each instrument comes in a ready-to-use kit that includes a manual, pre-measured unit dose reagents, sample cells, and a sturdy custom carrying case. Portable and convenient Rugged Specifications* 2 Lamp Light Emitting Diode (LED) Detector Silicon Enclosure IP67, waterproof at 1 m for 30 minutes (battery compartment excluded) Wavelength Fixed wavelength ±2 nm, varies with model Filter Bandwidth 15 nm Absorbance Range 0 to 2.5 Abs Sample Cell Pathlength 1 cm and 1-in. (25 mm) Operating Conditions 0 to 50°C (32 to 122°F) 0 to 90% relative humidity Display LCD, backlit Power Supply 4 AAA batteries; approximate life of 2000 tests (use of backlight reduces this number) Compliance European CE mark Warranty 2 years Dimensions 6.1 x 15.5 x 3.5 cm (2.5 x 6.2 x 1.4 in.) Weight 0.23 kg (0.5 lbs.) *Specifications subject to change without notice. Continued on next page. Parameters Parameter Range Method Alachlor 0.1, 0.5 ppb thresholds Immunoassay Aluminum 0.02 to 0.80 mg/L Al Aluminon Ammonia 0.01 to 0.80 mg/L NH3-N Salicylate Ammonia, Free 0.02 to 0.50 mg/L Free Ammonia as NH3-N; Indophenol and Monochloramine 0.04 to 4.50 mg/L Monochloramine as CI2 Atrazine 0.1, 0.5, 3.0 ppb thresholds Immunoassay Bromine 0.05 to 4.50; 0.2 to 10.0 mg/L Br2 DPD Chlorine, Free* and Total* **0.02 to 2.00; 0.1 to 8.0 mg/L Cl2 DPD Chlorine, Free, Total, and pH†0.1 to 10.0 mg/L Cl2 DPD 6.0 to 8.5 pH Phenol Red Chlorine, Free* and Total* **0.02 to 2.00; 0.1 to 8.0 mg/L Cl2 DPD SwifTest Dispenser Chlorine Dioxide*0.05 to 5.00 mg/L ClO2 DPD/Glycine Chromium, Hexavalent**0.01 to 0.70 mg/L Cr6+1,5 Diphenylcarbohydrazide Copper** 0.04 to 5.00 mg/L Cu Bicinchoninate Fluoride* **0.1 to 2.0 mg/L F-‡ SPADNS/SPADNS 2 Iron, FerroVer®**0.02 to 5.00 mg/L Fe FerroVer Iron, TPTZ 0.01 to 1.70 mg/L Fe TPTZ Lead, LeadTrak™5 to 150 µg/L Pb Fast Column Extraction Manganese, Low Range 0.01 to 0.70 mg/L Mn PAN Manganese, High Range**0.2-20.0 mg/L Mn Periodate Oxidation Molybdate 0.02 to 3.00; 0.1 to 12.0 mg/L Mo Ternary Complex Monochloramine and Free Ammonia 0.04 to 4.50 mg/L Monochloramine as CI2; Indophenol 0.02 to 0.50 mg/L Free Ammonia as NH3-N Nickel and Cobalt 0.01 to 1.00 mg/L Ni; 0.02 to 2.00 mg/L Co PAN Nitrate 0.4 to 30.0 mg/L NO3-N Cadmium Reduction Oxygen, Dissolved 0.2 to 10.0 mg/L O2 HRDO Ozone 0.01 to 0.25; 0.01 to 0.75 mg/L O3 Indigo Trisulfonate PCB in Soil 1, 5, 10, 50 ppm thresholds Immunoassay Phosphate* **0.02 to 3.00 mg/L PO4 PhosVer®3 Phosphonate 0.1 to 2.5; 1 to 125 mg/L PO4 PhosVer 3 with UV Digestion Parameters continued 3 Ordering Information Parameter Range Method Silica 1 to 100 mg/L SiO2 Silicomolybdate Sulfate**2 to 70 mg/L SO4 Turbidimetric TPH in Soil 20, 50, 100, 200 ppm thresholds Immunoassay TPH in Water 2, 5, 10, 20 ppm thresholds Immunoassay Zinc** 0.02 to 3.00 mg/L Zn Zincon *Method is USEPA accepted or approved for drinking water (additional steps may be required) **Method is USEPA accepted or approved for wastewater (additional steps may be required) †Phenol Red colorimetric pH measurement is not accepted for regulatory reporting. ‡Greater sensitivity (0.01 mg/L) is achieved by substituting bottled SPADNS reagent for the AccuVac® Ampuls provided in the kit. 2812900 Alachlor Pocket Colorimeter II; includes reagents for 18 tests 5870025 Aluminum Pocket Colorimeter II; includes reagents for 100 tests 5870040 Ammonia Pocket Colorimeter II; includes reagents for 100 tests 5870026 Ammonia, Free and Monochloramine Pocket Colorimeter II; includes reagents for 50 Free Ammonia tests, 100 Monochloramine tests 2763500 Atrazine Pocket Colorimeter II; includes reagents for 18 tests 5870001 Bromine Pocket Colorimeter II; includes reagents for 50 to 100 tests 5870000 Chlorine, Free and Total Pocket Colorimeter II; includes reagents for 50 to 100 tests 5870012 Chlorine, Free, Total, and pH Pocket Colorimeter II; includes reagents for 100 tests 5870023 Chlorine, Free, SwifTest Dispenser Pocket Colorimeter II; includes reagents for 125 to 250 tests 5870024 Chlorine, Total SwifTest Dispenser Pocket Colorimeter II; includes reagents for 125 to 250 tests 5870051 Chlorine Dioxide Pocket Colorimeter II; includes reagents for 100 tests 5870017 Chromium, Hexavalent Pocket Colorimeter II; includes reagents for 100 tests 5870019 Copper Pocket Colorimeter II; includes reagents for 100 tests 5870005 Fluoride Pocket Colorimeter II (SPADNS); includes reagents for up to 50 tests 2513100 Fluoride Pocket Colorimeter II (SPADNS 2–Arsenic-Free); includes reagents for up to 50 tests 5870022 Iron, FerroVer Pocket Colorimeter II; includes reagents for 100 tests 5870016 Iron, TPTZ Pocket Colorimeter II; includes reagents for 100 tests 5870021 Lead, LeadTrak Pocket Colorimeter II; includes reagents for 20 tests 5870018 Manganese, Low Range, Pocket Colorimeter II; includes reagents for 50 tests 5870015 Manganese, High Range, Pocket Colorimeter II; includes reagents for 100 tests 5870010 Molybdate Pocket Colorimeter II; includes reagents for 100 tests 5870020 Nickel and Cobalt Pocket Colorimeter II; includes reagents for 100 tests 5870002 Nitrate Pocket Colorimeter II; includes reagents for 100 tests 5870003 Oxygen, Dissolved Pocket Colorimeter II; includes reagents for 25 tests 5870004 Ozone Pocket Colorimeter II; includes reagents for up to 50 tests 2773400 PCB in Soil Pocket Colorimeter II; includes reagents for 18 tests 5870006 Phosphate Pocket Colorimeter II; includes reagents for 100 tests 5870007 Phosphonate Pocket Colorimeter II; includes reagents for 100 tests 5870034 Silica Pocket Colorimeter II; includes reagents for 100 tests 5870029 Sulfate Pocket Colorimeter II; includes reagents for 100 tests 2775000 TPH in Soil Pocket Colorimeter II; includes reagents for 18 tests 2774200 TPH in Water Pocket Colorimeter II; includes reagents for 18 tests 5870009 Zinc Pocket Colorimeter II; includes reagents for 100 tests Continued on next page. The Hach Pocket Colorimeter II includes manual, pre-measured unit dose reagents, sample cells, and a carrying case. Reagents can be refilled by contacting Hach or your Hach distributor. Lit. No. 2596 Rev 2 F9 Printed in U.S.A. ©Hach Company, 2009. All rights reserved. In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time. For current price information, technical support, and ordering assistance, contact the Hach office or distributor serving your area. In the United States, contact: HACH COMPANY World Headquarters P.O. Box 389 Loveland, Colorado 80539-0389 U.S.A. Telephone: 800-227-4224 Fax: 970-669-2932 E-mail: orders@hach.com www.hach.com U.S. exporters and customers in Canada, Latin America, sub-Saharan Africa, Asia, and Australia/New Zealand, contact: HACH COMPANY World Headquarters P.O. Box 389 Loveland, Colorado 80539-0389 U.S.A. Telephone: 970-669-3050 Fax: 970-461-3939 E-mail: intl@hach.com www.hach.com In Europe, the Middle East, and Mediterranean Africa, contact: HACH LANGE GmbH Willstätterstraße 11 D-40549 Düsseldorf GERMANY Tel: +49 (0) 211 5288-0 Fax: +49 (0) 211 5288-143 E-mail: info@hach-lange.de www.hach-lange.com At Hach, it’s about learning from our customers and providing the right answers. It’s more than ensuring the quality of water—it’s about ensuring the quality of life. When it comes to the things that touch our lives... Keep it pure. Make it simple. Be right. 4 Ordering Information continued Wavelength-specific Pocket Colorimeters Program custom methods and calibrations on two channels. 5870042 Pocket Colorimeter II; Light Wavelength 420 nm 5870045 Pocket Colorimeter II; Light Wavelength 450 nm 5870050 Pocket Colorimeter II; Light Wavelength 500 nm 5870052 Pocket Colorimeter II; Light Wavelength 528 nm 5870055 Pocket Colorimeter II; Light Wavelength 550 nm 5870058 Pocket Colorimeter II; Light Wavelength 580 nm 5870060 Pocket Colorimeter II; Light Wavelength 600 nm 5870065 Pocket Colorimeter II; Light Wavelength 655 nm Standards Spec✔Ampule Standards are colored gels that simulate the color produced by the analytical procedure, for simple checks on instrument response. Each set includes a blank and three concentrations. 2635300 Chlorine Spec✔Standard Kit, DPD LR (0 to 2.0 mg/L Cl2); set of 4 vials 2893300 Chlorine Spec✔Standard Kit, DPD HR (0 to 6.5 mg/L Cl2); set of 4 vials 2712500 Fluoride Spec✔Standard Kit (0 to 2.00 mg/L F-); set of 4 vials 2507500 Monochloramine/Free Ammonia Spec✔Standard Kit (0 to 4.5 mg/L Cl2 and 0 to 0.50 mg/L NH3-N); set of 4 vials 2708000 Ozone MR Spec✔Standard Kit (0 to 0.75 mg/L); set of 4 vials Accessory 5953100 Pocket Colorimeter II Soft-Sided Case/Holster (holds colorimeter, two sample cells and reagent pouches) The optional soft-sided case/holster holds the Pocket Colorimeter, two vials, and more!