HomeMy WebLinkAboutPressure - TAB 1 - ASHCROFT Pressure Gages85
Consult factory for guidance in product selectionPhone (203) 385-0217, Fax (203) 385-0602 or visit our web site at www.ashcroft.com
STANDARD RANGES (4)
Pressure psi kg/cm2 - bar kPa
0/15
0/30
0/60
0/100
0/160
0/200
0/300
0/400
0/600
0/800
0/1000
0/1500
0/2000
0/3000
0/4000
0/5000
0/6000
0/7500
0/10,000
0/15,000
0/20,000
0/30,000
Vacuum
30 in. /0 in.Hg –1/0 –100/0
Compound
30 in.Hg/15 psi –1/0/1.5 –100/0/150
30 in.Hg /30 psi –1/0/3 –100/0/300
30 in.Hg /60 psi –1/0/5 –100/0/500
30 in.Hg/100 psi –1/0/9 –100/0/900
30 in.Hg /150 psi –1/0/15 –100/0/1500
30 in.Hg/300 psi –1/0/24 –100/0/2400
The 41⁄1⁄12⁄2⁄˝ and 6˝ Ashcroft® Type ® Type ®
1009 gauges are suitable where
ambient corrosion is a major con-
cern. Its stainless steel case and ring
offer good appearance and excellent
resistance to chemical, weather and
corrosion attack. This 1009 has many
optional features that allow a user
to develop a basic or special product
specifi cation. The 1009 is part of the
extensive line of Ashcroft stainless
steel pressure gauges.
The gauge is available dry, liquid-
fi lled weatherproof or hermetically
sealed and now with now with now PLUS!™ perfor-™ perfor-™
mance option.
• 4• 4•1⁄1⁄12⁄2⁄˝ and 6˝ stainless steel gauges
• Dry and liquid-fi lled versions
• Micrometer adjustable pointer
• VarietyofBourdon tube materialsmaterialsmaterial
• ASME Grade 1A, ±1% of span accuracy
• New PLUS!™ Performance Option:™ Performance Option:™
- Liquid-fi lled performance in a dry gauge
TO ORDER THIS 1009 DURALIFE PRESSURE GAUGE:
Select: 45 1009 S 02L XXX 1000#
1. Dial size–41⁄1⁄12⁄2⁄˝, 6˝
2. Case type –1009
3. Tube and socket material
4. Connection size–1⁄1⁄14⁄4⁄ (02), 1⁄1⁄12⁄2⁄ (04)
5. Connection location–Lower (L), Back (B)
6. Optional features–see page 176
7. Standard pressure range–1000 psi
Accessories–see pages 233-238
General Service Gauge
Type 1009, ASME B 40.1
Grade 1A (±1% of span)
0/1 0/100
0/1.6 0/160 0/1.6 0/160
0/2.5 0/250 0/2.5 0/250
0/4 0/400 0/4 0/400
0/6 0/600 0/6 0/600
0/10 0/1000 0/10 0/1000
0/16 0/1600 0/16 0/1600
0/25 0/2500 0/25 0/2500
0/40 0/4000 0/40 0/4000
0/60 0/6000 0/60 0/6000
0/100 0/10,000 0/100 0/10,000
0/160 0/16,000 0/160 0/16,000
0/250 0/25,000 0/250 0/25,000
0/400 0/40,000 0/7500 0/400 0/40,000 0/7500 0/400 0/40,000
0/600 0/60,000 0/10,000 0/600 0/60,000 0/10,000 0/600 0/60,000
0/1000 0/100,000 0/1000 0/100,000
0/1600 0/160,000 0/30,000 0/1600 0/160,000 0/30,000 0/1600 0/160,000
The following Table is not for conversion purposes.
BOURDON SYSTEM SELECTION(1)
Ordering Bourdon Tube & Tip Socket Tube Range Selection NPT Code Material(1) (all joints TIG Material Type Limits (psi) Conn.(2)
welded except “A”)
A Phosphor Bronze Brass C-Tube 12/1000 1⁄1⁄14⁄4⁄ Brass Tip, Silver Brazed
S 316 stainless steel 316 stainless steel C-Tube 12/1500 1⁄1⁄14⁄4⁄
Helical 2000/20,000 1⁄1⁄12⁄2⁄
P(3)(5) K Monel Monel 400 C-Tube 15/1500 1⁄1⁄14⁄4⁄
Helical 2000/30,000 1⁄1⁄12⁄2⁄
(1) For selection of the correct Bourdon system material, see the
media application table on page 243.
(2) Optional connections available: 1⁄1⁄12⁄2⁄ NPT where 1⁄1⁄14⁄4⁄ NPT is
standard, 1⁄1⁄14⁄4⁄ NPT where 1⁄1⁄12⁄2⁄ NPT is standard.
(3) Use for applications where NACE Standard MR-01-75 is
specifi ed.
(4) Single-scale and dual-scale ranges available .
(5) 6˝ dial not available with monel or steel systems.
- Fights vibration and pulsations without liquid-fi ll headaches
- See pages 6-7 for details
- Order as option XLL
143
Consult factory for guidance in product selectionPhone (203) 385-0217, Fax (203) 385-0602 or visit our web site at www.ashcroft.com
Table C Bottom Housing Materials
Material Code
Steel B 304L stainless steel C 316L stainless steel S Hastelloy B G Hastelloy C 22(7) J Hastelloy C 276(7) H Carpenter 20 D Monel “400”(7) M Inconel “600” W Nickel N PVC(8) V Tantalum clad stainless steel(9) SU Halar coated stainless steel(10) BH Tefl on fl anged steel(11) T Kynar(13)(14) KY Titanium(13) TI
Diaphragm Seal
Type 200, Welded or Bonded
Type 200 Welded• Tefl on gasketed, continuous-duty
diaphragm capsule is welded to the top housing, which is then clamped
to a bottom housing.
• Fill/bleed connection is standard.
• Top housing and pressure instru-ment are removable.
• Available in same process connec-tions, materials, types and sizes as
the Type 100 capsule design.
• Top housing is interchangeable
with all standard Ashcroft®with all standard Ashcroft®with all standard Ashcroft bottom ® bottom ®
housings.
Type 200 Bonded Viton, Kalrezand Tefl onSimilar in construction, materials,
and product features to the Type 300 clamped diaphragm seal on page 142,
the diaphragm in the Type 200 seal is bonded permanently to the top
housing – and is the removable type.
Table A – Process Connection/Type Number
Process Connection Size/Code—Inches Type Number
Size 1⁄1⁄1 4⁄4⁄1⁄1⁄1 2⁄2⁄3⁄3⁄3 4⁄4⁄ 1 11⁄1⁄12⁄2⁄ 2 3 4 6 8 Welded &
Process Connection Code 25 50 75 10 15 20 30 40 60 80 Bonded(3)
Threaded–female NPT • • • • • 200
Threaded–female NPT (with fl ushing connection) • • • • • 201
Flanged(1) • • • • • • 202
Flanged (with fl ushing connection) • • • • • • 203
In-line—threaded NPT • • • • 204
Saddle • AND LARGER 205
In-line—butt weld • • • • • • 208
In-line—fl anged(2) • • • • • • • • • 206
In-line—socket weld • • • • • • 207
Table E – Filling Fluid
Filling Service Connection to Instrument Temperature Range °F Code
Glycerin Pressure Direct Only 0/400 CG
Silicone Pressure/Vacuum Direct or Flexible Line –40/600 CK
Halocarbon Pressure/Vacuum in presence of strong oxidizing agent Direct or Flexible Line –70/300 CF
Syltherm Pressure/Vacuum Direct or Flexible Line –40/750 HA
1. From Table A...select TYPE NUMBER based on process connection, process connection size and diaphragm
type/construction. (e.g., Threaded/1˝/welded–code-10-200)
2. From Table B...select DIAPHRAGM MATERIAL. (e.g., 316L stainless steel–code S)
3. From Table C...select BOTTOM HOUSING MATERIAL. (e.g., 316 stainless steel–code S)
4. From Table D...select INSTRUMENT CONNECTION size. (e.g., 1⁄1⁄14 ⁄4 ⁄NPT–code 02T)
5. From Table E...select FILLING FLUID, if diaphragm seal will be attached to instrument. (e.g., Glycerin–code CG)
Coded order: 10–200SS–02T–CG
TO ORDER THIS TYPE 200 DIAPHRAGM SEAL:
SELECTION TABLES
Table B Diaphragm Material
Material Code
316L stainless steel S 304 stainless steel C K-Monel(8) P Nickel N Carpenter 20 D Tantalum U Hastelloy B G Hastelloy C 22(7) J Hastelloy C 276(7) H Tefl on(5) T Viton(6) Y Kalrez(12) K Titanium TI
NOTES:
(1) 150, 300, 600, 900, 1500 & 2500 class fl anges.
(2) 1˝ 150 thru 8˝ 300 class fl anges only.
(3) Metal diaphragms welded; Tefl on, Kalrez & Viton diaphragms bonded.
(5) Temp. Limits: –40/400°F.
(6) Max. Pressure: 500 psi. Temp. Limits: –40/350°F.
(7) Use on applications where NACE standard MR-01-75 2003 is specifi ed.
(8) Maximum Press./Temp. Threaded: 200 psi/74°F, 125 psi/125°F, 80 psi/150°F. Flanged: 75 psi/100°F.
(9) Type 202 only.
(10) Temp. Limits: –40/300°F.
(11) Only available in 1˝, 1 1⁄1⁄12⁄2⁄˝, & 2˝ 150 class, Type 202. Max. Press./Temp. – 270 psi and 150°F. Consult factory for conditions beyond these limits.
(12) Max. Pressure: 500 psi Temp. Limits: 30/212°F.
(13) On application.
(14) Maximum Pressure/Temp.: 200 psi and 180°F.
Table D Instrument Connection
Size – NPT Code
1⁄1⁄14⁄4⁄ 02T1⁄1⁄12⁄2⁄ 04T
Pressure Ratings—All 2500 psi except fl anged seals are per ASME B 16.5, temperature limit determined by diaphragm, bottom housing and/or fi lling fl uid.
244 245
Consult factory for guidance in product selection
Phone (203) 385-0217, Fax (203) 385-0602 or
visit our web site at www.ashcroft.com
Ashcroft® Options
TEST GAUGES 1008S GENERAL SERVICESPECIAL SERVICE1490/1495 SERIES1009 (41/2/2/˝, 6˝)1009 (21/2/2/˝, 31/2/2/˝)DURAGAUGES CODE DESCRIPTION PRESSURE GAUGE TYPE
STAINLESS STEEL CASE INDUSTRIAL GAUGE
NOTES:
The options listed above are only a partial listing. For other options on these or other pressure instruments please call the factory for availability.
(1) Available on 63mm and 100mm.
(2) Available on 40mm and 50mm.
XLL PLUS! Performance PLUS! Performance PLUS! (1)
XNS PLUS! Performance – Silicone Free PLUS! Performance – Silicone Free PLUS!
XBF WaII mounting bracket
XFW Back fl ange
XFF Front fl ange
XUC U-clamp
XLJ Dry liquid-fi llable gauge
XOS Overload stop STD STD(1) STD
XVS Underload stop STD STD(1) STD
XTS Throttle screw
XTU Throttle plug
XS4 Slotted link movement (decrease)
XRJ Slotted link (increase)
XAP Adjustable pointer
XMP Micrometer pointer STD
XSH Red set hand stationary
XEO Red set hand adjustable
XEP Maximum pointer
XEQ Minimum pointer
XPD Plastic window STD STD(2) STD
XSG Safety glass
XMG Metric version gauge
XRG Regular glass STD STD STD STD STD
XDA Dial marking
XNN Paper tag
XNH Stainless steel tag
XAB Absolute pressure
XAJ 1⁄1⁄1 2⁄2⁄% optional accuracy STD
XAN 1% optional accuracy STD STD STD
XRA Retard scale
XWN White dial STD STD STD STD
XBD Black dial
X6B Oxygen-cleaned gauges (gaseous)
XTB Tip bleed
XED High and low electric contacts
XEE Double high-electric contacts
XEF Double low-electric contacts
XEG Electric contacts off at low or
high and in-between
XGV Silicone-fi lled gauge
XGX Halocarbon-fi lled gauge
XCH Carrying handle
XC4 Calibration Chart
246
Consult factory for guidance in product selection
Phone (203) 385-0217, Fax (203) 385-0602 or
visit our web site at www.ashcroft.com
Ashcroft® Options
CAPILLARY BLEED
of the bourdon tube. It may be used as a pressure testing tap for gauge inspection
without removing the gauge from service. Capillary bleeders are available in bottom
connected gauges only. The capillary bleeder is available in 300 Series stainless
steel and limited to 41/2˝ 1379(S)S case with 316 stainless steel system. Capillary
bleeders are available to 1000 psi.
These bleeders allow trapped air to be removed from the bourdon tube. They can
also be used for back-fl ushing or clean-ing the system. The tip bleed is available
with 316 stainless steel systems. It is accessible by removing the pressure relief
back. Tip bleeders are available to 23,000 psi. The capillary bleeder provides an
external case connection to the internals
TIP BLEEDER
Used to fl ush-mount gauge types 1188, 1220, 1279 and 1379. Standard fi nish is
black; polished stainless steel fi nish is available at an extra charge, 41⁄1⁄12⁄2⁄˝ and 6.˝
Gauge Ring A “B”-Three Screws Size O.D. Dia. (inches) (inches) (inches) Size
41⁄1⁄12⁄2⁄ 6.000 5.625 #10-24 x 15⁄5⁄58⁄8⁄˝
6 7.765 7.25 1⁄1⁄14⁄4⁄-20 x 11⁄1⁄12⁄2⁄˝
CAPILLARY BLEEDER
Maximum Pointeravailable for gauges 41⁄1⁄12⁄2⁄˝ size and larger. Indicates maximum pressure attained. Can be reset by a knob on outside of window.
Plastic Disc – optional for glass window
Laminated Safety Glass – optional for
glass window
Nonglare Glass – optional for glass window
Vacuum Stop
to protect low range gauges against
vacuum.
MAXIMUM POINTER VACUUM STOP
Stationary Red Set Hand
to indicate a specifi c pressure. Ring must
be removed to move the hand.
Special Dialranges different from standards, or custom
artwork, available on application.
Overload Stopto protect gauge system against extreme
overpressure.
STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL
TYPE 1278M FLUSH MOUNTING RING
TIP BLEED
OPTIONAL WINDOWS