HomeMy WebLinkAboutPressure - TAB 1 - ASHCROFT Pressure Gages85 Consult factory for guidance in product selectionPhone (203) 385-0217, Fax (203) 385-0602 or visit our web site at www.ashcroft.com STANDARD RANGES (4) Pressure psi kg/cm2 - bar kPa 0/15 0/30 0/60 0/100 0/160 0/200 0/300 0/400 0/600 0/800 0/1000 0/1500 0/2000 0/3000 0/4000 0/5000 0/6000 0/7500 0/10,000 0/15,000 0/20,000 0/30,000 Vacuum 30 in. /0 in.Hg –1/0 –100/0 Compound 30 in.Hg/15 psi –1/0/1.5 –100/0/150 30 in.Hg /30 psi –1/0/3 –100/0/300 30 in.Hg /60 psi –1/0/5 –100/0/500 30 in.Hg/100 psi –1/0/9 –100/0/900 30 in.Hg /150 psi –1/0/15 –100/0/1500 30 in.Hg/300 psi –1/0/24 –100/0/2400 The 41⁄1⁄12⁄2⁄˝ and 6˝ Ashcroft® Type ® Type ® 1009 gauges are suitable where ambient corrosion is a major con- cern. Its stainless steel case and ring offer good appearance and excellent resistance to chemical, weather and corrosion attack. This 1009 has many optional features that allow a user to develop a basic or special product specifi cation. The 1009 is part of the extensive line of Ashcroft stainless steel pressure gauges. The gauge is available dry, liquid- fi lled weatherproof or hermetically sealed and now with now with now PLUS!™ perfor-™ perfor-™ mance option. • 4• 4•1⁄1⁄12⁄2⁄˝ and 6˝ stainless steel gauges • Dry and liquid-fi lled versions • Micrometer adjustable pointer • VarietyofBourdon tube materialsmaterialsmaterial • ASME Grade 1A, ±1% of span accuracy • New PLUS!™ Performance Option:™ Performance Option:™ - Liquid-fi lled performance in a dry gauge TO ORDER THIS 1009 DURALIFE PRESSURE GAUGE: Select: 45 1009 S 02L XXX 1000# 1. Dial size–41⁄1⁄12⁄2⁄˝, 6˝ 2. Case type –1009 3. Tube and socket material 4. Connection size–1⁄1⁄14⁄4⁄ (02), 1⁄1⁄12⁄2⁄ (04) 5. Connection location–Lower (L), Back (B) 6. Optional features–see page 176 7. Standard pressure range–1000 psi Accessories–see pages 233-238 General Service Gauge Type 1009, ASME B 40.1 Grade 1A (±1% of span) 0/1 0/100 0/1.6 0/160 0/1.6 0/160 0/2.5 0/250 0/2.5 0/250 0/4 0/400 0/4 0/400 0/6 0/600 0/6 0/600 0/10 0/1000 0/10 0/1000 0/16 0/1600 0/16 0/1600 0/25 0/2500 0/25 0/2500 0/40 0/4000 0/40 0/4000 0/60 0/6000 0/60 0/6000 0/100 0/10,000 0/100 0/10,000 0/160 0/16,000 0/160 0/16,000 0/250 0/25,000 0/250 0/25,000 0/400 0/40,000 0/7500 0/400 0/40,000 0/7500 0/400 0/40,000 0/600 0/60,000 0/10,000 0/600 0/60,000 0/10,000 0/600 0/60,000 0/1000 0/100,000 0/1000 0/100,000 0/1600 0/160,000 0/30,000 0/1600 0/160,000 0/30,000 0/1600 0/160,000 The following Table is not for conversion purposes. BOURDON SYSTEM SELECTION(1) Ordering Bourdon Tube & Tip Socket Tube Range Selection NPT Code Material(1) (all joints TIG Material Type Limits (psi) Conn.(2) welded except “A”) A Phosphor Bronze Brass C-Tube 12/1000 1⁄1⁄14⁄4⁄ Brass Tip, Silver Brazed S 316 stainless steel 316 stainless steel C-Tube 12/1500 1⁄1⁄14⁄4⁄ Helical 2000/20,000 1⁄1⁄12⁄2⁄ P(3)(5) K Monel Monel 400 C-Tube 15/1500 1⁄1⁄14⁄4⁄ Helical 2000/30,000 1⁄1⁄12⁄2⁄ (1) For selection of the correct Bourdon system material, see the media application table on page 243. (2) Optional connections available: 1⁄1⁄12⁄2⁄ NPT where 1⁄1⁄14⁄4⁄ NPT is standard, 1⁄1⁄14⁄4⁄ NPT where 1⁄1⁄12⁄2⁄ NPT is standard. (3) Use for applications where NACE Standard MR-01-75 is specifi ed. (4) Single-scale and dual-scale ranges available . (5) 6˝ dial not available with monel or steel systems. - Fights vibration and pulsations without liquid-fi ll headaches - See pages 6-7 for details - Order as option XLL 143 Consult factory for guidance in product selectionPhone (203) 385-0217, Fax (203) 385-0602 or visit our web site at www.ashcroft.com Table C Bottom Housing Materials Material Code Steel B 304L stainless steel C 316L stainless steel S Hastelloy B G Hastelloy C 22(7) J Hastelloy C 276(7) H Carpenter 20 D Monel “400”(7) M Inconel “600” W Nickel N PVC(8) V Tantalum clad stainless steel(9) SU Halar coated stainless steel(10) BH Tefl on fl anged steel(11) T Kynar(13)(14) KY Titanium(13) TI Diaphragm Seal Type 200, Welded or Bonded Type 200 Welded• Tefl on gasketed, continuous-duty diaphragm capsule is welded to the top housing, which is then clamped to a bottom housing. • Fill/bleed connection is standard. • Top housing and pressure instru-ment are removable. • Available in same process connec-tions, materials, types and sizes as the Type 100 capsule design. • Top housing is interchangeable with all standard Ashcroft®with all standard Ashcroft®with all standard Ashcroft bottom ® bottom ® housings. Type 200 Bonded Viton, Kalrezand Tefl onSimilar in construction, materials, and product features to the Type 300 clamped diaphragm seal on page 142, the diaphragm in the Type 200 seal is bonded permanently to the top housing – and is the removable type. Table A – Process Connection/Type Number Process Connection Size/Code—Inches Type Number Size 1⁄1⁄1 4⁄4⁄1⁄1⁄1 2⁄2⁄3⁄3⁄3 4⁄4⁄ 1 11⁄1⁄12⁄2⁄ 2 3 4 6 8 Welded & Process Connection Code 25 50 75 10 15 20 30 40 60 80 Bonded(3) Threaded–female NPT • • • • • 200 Threaded–female NPT (with fl ushing connection) • • • • • 201 Flanged(1) • • • • • • 202 Flanged (with fl ushing connection) • • • • • • 203 In-line—threaded NPT • • • • 204 Saddle • AND LARGER 205 In-line—butt weld • • • • • • 208 In-line—fl anged(2) • • • • • • • • • 206 In-line—socket weld • • • • • • 207 Table E – Filling Fluid Filling Service Connection to Instrument Temperature Range °F Code Glycerin Pressure Direct Only 0/400 CG Silicone Pressure/Vacuum Direct or Flexible Line –40/600 CK Halocarbon Pressure/Vacuum in presence of strong oxidizing agent Direct or Flexible Line –70/300 CF Syltherm Pressure/Vacuum Direct or Flexible Line –40/750 HA 1. From Table A...select TYPE NUMBER based on process connection, process connection size and diaphragm type/construction. (e.g., Threaded/1˝/welded–code-10-200) 2. From Table B...select DIAPHRAGM MATERIAL. (e.g., 316L stainless steel–code S) 3. From Table C...select BOTTOM HOUSING MATERIAL. (e.g., 316 stainless steel–code S) 4. From Table D...select INSTRUMENT CONNECTION size. (e.g., 1⁄1⁄14 ⁄4 ⁄NPT–code 02T) 5. From Table E...select FILLING FLUID, if diaphragm seal will be attached to instrument. (e.g., Glycerin–code CG) Coded order: 10–200SS–02T–CG TO ORDER THIS TYPE 200 DIAPHRAGM SEAL: SELECTION TABLES Table B Diaphragm Material Material Code 316L stainless steel S 304 stainless steel C K-Monel(8) P Nickel N Carpenter 20 D Tantalum U Hastelloy B G Hastelloy C 22(7) J Hastelloy C 276(7) H Tefl on(5) T Viton(6) Y Kalrez(12) K Titanium TI NOTES: (1) 150, 300, 600, 900, 1500 & 2500 class fl anges. (2) 1˝ 150 thru 8˝ 300 class fl anges only. (3) Metal diaphragms welded; Tefl on, Kalrez & Viton diaphragms bonded. (5) Temp. Limits: –40/400°F. (6) Max. Pressure: 500 psi. Temp. Limits: –40/350°F. (7) Use on applications where NACE standard MR-01-75 2003 is specifi ed. (8) Maximum Press./Temp. Threaded: 200 psi/74°F, 125 psi/125°F, 80 psi/150°F. Flanged: 75 psi/100°F. (9) Type 202 only. (10) Temp. Limits: –40/300°F. (11) Only available in 1˝, 1 1⁄1⁄12⁄2⁄˝, & 2˝ 150 class, Type 202. Max. Press./Temp. – 270 psi and 150°F. Consult factory for conditions beyond these limits. (12) Max. Pressure: 500 psi Temp. Limits: 30/212°F. (13) On application. (14) Maximum Pressure/Temp.: 200 psi and 180°F. Table D Instrument Connection Size – NPT Code 1⁄1⁄14⁄4⁄ 02T1⁄1⁄12⁄2⁄ 04T Pressure Ratings—All 2500 psi except fl anged seals are per ASME B 16.5, temperature limit determined by diaphragm, bottom housing and/or fi lling fl uid. 244 245 Consult factory for guidance in product selection Phone (203) 385-0217, Fax (203) 385-0602 or visit our web site at www.ashcroft.com Ashcroft® Options TEST GAUGES 1008S GENERAL SERVICESPECIAL SERVICE1490/1495 SERIES1009 (41/2/2/˝, 6˝)1009 (21/2/2/˝, 31/2/2/˝)DURAGAUGES CODE DESCRIPTION PRESSURE GAUGE TYPE STAINLESS STEEL CASE INDUSTRIAL GAUGE NOTES: The options listed above are only a partial listing. For other options on these or other pressure instruments please call the factory for availability. (1) Available on 63mm and 100mm. (2) Available on 40mm and 50mm. XLL PLUS! Performance PLUS! Performance PLUS!   (1) XNS PLUS! Performance – Silicone Free PLUS! Performance – Silicone Free PLUS!    XBF WaII mounting bracket  XFW Back fl ange  XFF Front fl ange    XUC U-clamp     XLJ Dry liquid-fi llable gauge     XOS Overload stop  STD  STD(1) STD   XVS Underload stop  STD  STD(1) STD   XTS Throttle screw      XTU Throttle plug    XS4 Slotted link movement (decrease)     XRJ Slotted link (increase)     XAP Adjustable pointer     XMP Micrometer pointer STD     XSH Red set hand stationary      XEO Red set hand adjustable        XEP Maximum pointer      XEQ Minimum pointer      XPD Plastic window  STD  STD(2)    STD XSG Safety glass       XMG Metric version gauge   XRG Regular glass STD STD STD STD STD XDA Dial marking         XNN Paper tag         XNH Stainless steel tag         XAB Absolute pressure    XAJ 1⁄1⁄1 2⁄2⁄% optional accuracy STD    XAN 1% optional accuracy STD STD STD  XRA Retard scale    XWN White dial STD   STD STD   STD XBD Black dial         X6B Oxygen-cleaned gauges (gaseous)        XTB Tip bleed   XED High and low electric contacts  XEE Double high-electric contacts  XEF Double low-electric contacts  XEG Electric contacts off at low or  high and in-between XGV Silicone-fi lled gauge     XGX Halocarbon-fi lled gauge     XCH Carrying handle  XC4 Calibration Chart         246 Consult factory for guidance in product selection Phone (203) 385-0217, Fax (203) 385-0602 or visit our web site at www.ashcroft.com Ashcroft® Options CAPILLARY BLEED of the bourdon tube. It may be used as a pressure testing tap for gauge inspection without removing the gauge from service. Capillary bleeders are available in bottom connected gauges only. The capillary bleeder is available in 300 Series stainless steel and limited to 41/2˝ 1379(S)S case with 316 stainless steel system. Capillary bleeders are available to 1000 psi. These bleeders allow trapped air to be removed from the bourdon tube. They can also be used for back-fl ushing or clean-ing the system. The tip bleed is available with 316 stainless steel systems. It is accessible by removing the pressure relief back. Tip bleeders are available to 23,000 psi. The capillary bleeder provides an external case connection to the internals TIP BLEEDER Used to fl ush-mount gauge types 1188, 1220, 1279 and 1379. Standard fi nish is black; polished stainless steel fi nish is available at an extra charge, 41⁄1⁄12⁄2⁄˝ and 6.˝ Gauge Ring A “B”-Three Screws Size O.D. Dia. (inches) (inches) (inches) Size 41⁄1⁄12⁄2⁄ 6.000 5.625 #10-24 x 15⁄5⁄58⁄8⁄˝ 6 7.765 7.25 1⁄1⁄14⁄4⁄-20 x 11⁄1⁄12⁄2⁄˝ CAPILLARY BLEEDER Maximum Pointeravailable for gauges 41⁄1⁄12⁄2⁄˝ size and larger. Indicates maximum pressure attained. Can be reset by a knob on outside of window. Plastic Disc – optional for glass window Laminated Safety Glass – optional for glass window Nonglare Glass – optional for glass window Vacuum Stop to protect low range gauges against vacuum. MAXIMUM POINTER VACUUM STOP Stationary Red Set Hand to indicate a specifi c pressure. Ring must be removed to move the hand. Special Dialranges different from standards, or custom artwork, available on application. Overload Stopto protect gauge system against extreme overpressure. STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL TYPE 1278M FLUSH MOUNTING RING TIP BLEED OPTIONAL WINDOWS