Loading...
HomeMy WebLinkAboutAnalytical - TAB 2 - Rotronic Hygroflex Dewpoint AnalyzerNetworkable Industrial Transmitter Humidity, Temperature and Dew Point or other Computed Parameter •Unique HygroClip®technology for superior performance•Durable, field proven humidity and temperature sensors•Interchangeable probe design eliminates maintenance downtime•Wide range of probes to satisfy every application•Optional display and keypad•Available with a metal enclosureHumidity goes Digital160 E. Main Street •Huntington, NY 11743 •Ph. (631) 427-3898 •Fax. (631) 427-3902 •www.rotronic-usa.com®® Optional metal enclosure HygroClip IC-3 Recommended for the measurement of most processes, this probe is easily installed through a wall (see installation below). For high RH% and high temperature processes see IM-3. PPS body, wire mesh filter Probe and probe cable: min. -50°C (-58°F), max. 200ºC (392ºF) Probe connector: min. -40°C (-40°F), max. 85°C (185°F) HygroClip IM-1 Similar to IC-3, but with a short body, this probe is designed for full immersion in the process to be measured. Temperature limits: same as IC-3 HygroClip IM-3 Similar to the IC-3, this probe should be selected for use in processes that combine high humidity and moderate to high temperature such as pasta dryers, environmental chambers, etc. - Stainless steel body, wire mesh filter Temperature limits: same as IC-3 HygroClip IC-1 Similar to the IC-3, but with a short body, this probe can be installed well inside the process to be measured. The IC-1 is also used for measuring inside ducts with a small cross section. In both cases, the probe should be fully immersed in the environment to be measured (see installation below) PPS body, wire mesh filter Temperature limits: same as IC-3 HygroClip IE-3 Measurement in compressed air. This probe has a 1/2" NPT thread and can be used at pressures up to 50 bar/725 PSI. Not suitable in applications where there is a temperature difference across the mounting wall. min. -40°C (-40°F), max 85ºC (185ºF) sintered steel filter Also available with 1/2"G thread (model IE-1) HygroClip IC-05 5mm (0.2") diameter for measurement in tight spaces min. -50°C (-58°F), max. 100ºC (212ºF) AC1616 Probe Extension Cable Suitable for use with all probes - built in signal booster. Cable length 6 to 656 ft (2 to 200m) min. -40°C (-40°F), max. 85°C (185°F) HygroClip IW Area monitoring (wall mounted transmitter) wire mesh filter. Min. -40°C (-40°F), max. 85°C (185°F) HygroFlex Probe Selection Guide L. 145mm (5.7”) Dia. 15mm (0.6”) Tube L. 250mm (9.8”) Dia. 15mm (0.6”) Cable: 2m (6.5ft) Tube L. 120mm (4.7/10.6”) Dia. 15mm (0.6”) Cable: 2m (6.5ft) Cable: 2m (6.5ft) Dia. 5mm (0.2”) Cable: 2m (6.5ft) Note: we also offer intrinsically safe probes for use in hazardous areas. Standard Probes Special Probes Tube L. 100mm (3.9”) Dia. 15mm (0.6”) Cable: 2m (6.5ft) Tube L. 270mm (10.6”) Dia. 15mm (0.6”) Cable: 2m (6.5ft) Installation of probes type IC and IM IC-3 and IM-3 probes (long probe body): the QMA-15 adapter is convenient both for installing and servicing the probe. The adapter is comprised of a compression fitting and a 3'' flange. The probe should be immersed as much as possible in the process to be measured, especially when temperature is not the same on both sides of the wall. IC-1 and IM-1 probes (short probe body): the probe and its cable should be fully immersed in the environment to be measured (leave the probe connector outside). In a duct of small cross section, install the probe axially. Attach the probe with a clip, a tie or a bracket at a well ventilated location (such as a vent). Do not install the probe through or against a wall, unless temperature is the same on both sides of the wall: insufficient probe immersion will result both in a temperature and a humidity error. QMA-15 min. 7" Humidity goes Digital ® HygroFlex 2:100% Digital •%RH and temperature and calculated value (dew-point, mixing ratio, etc) •RS232 output (%RH and temperature) •Networkable (RS232 first HygroFlex to PC / RS485 between transmitters) •Optional 2nd probe input (digital or analog) •Fully user programmable HygroFlex 3:Analog & Digital Outputs •%RH, temperature and calculated value (dew-point, mixing ratio, etc) •Three linear analog outputs: 4-20 mA, 0-5V, etc. •Jumper configuration of analog outputs signal type •Simultaneous digital output •RS232 output (%RH and temperature) •Networkable (RS232 first HygroFlex to PC / RS485 between transmitters) •Optional 2nd probe input (digital or analog) •Fully user programmable PCHygroPalm Calibrator Analog Outputs RS232 RS485 PC HygroPalm Calibrator RS232 RS485 The HygroFlex industrial humidity and temperature transmitter uses the very latest digital technology. Digital signal processing significantly benefits humidity and temperature measurement in the following key areas: 1.Measurement Accuracy The digital circuits used both in the HygroFlex and associated probe are inherently more stable and consistent than conventional analog circuits. Digital processing of the sensor signals by the probe also provides more scope and greater flexibility when compensating sensor linearity and temperature coefficient. The ROTRONIC HYGROMER™capacitive humidity sensor has always been the leader both in precision and stability. With the application of digital technology, sensor performance is now further improved. 2. Maintenance and Calibration Unique HygroClip®digital technology virtually eliminates downtime during maintenance. When it is time for a scheduled calibration, the interchangeable probe can be ‘hot swapped’ in seconds with a calibrated replacement probe. There is no need to remove the complete transmitter to a calibration laboratory and there is practically no interruption of the measurement data. The HygroClip probe can be directly calibrated while connected to the HygroFlex (requires the optional display and keypad), or it can be calibrated separately using either a PC or the HygroPalm The Digital Advantage portable calibrator. Calibration and sensor data are retained permanently within each HygroClip probe. Software-based calibration is both simple and precise; there are no hard-to- reach, hard-to-adjust potentiometers. Multiple calibration points can be selected across the full measuring range. On-site performance verification is equally easy. Each HygroFlex has a test connector for use with a portable HygroPalm calibrator. The HygroPalm can display the signals from the HygroFlex without interrupting operation and a comparison can be made with the readings of the probe connected to the HygroPalm. 3.Measurement of Dew-Point and other Parameters Digital technology makes it possible to obtain parameters such as dew-point or the mixing ratio with economical, versatile and easy-to-maintain instruments and probes. Comparing the HygroFlex to existing chilled mirror technology typical requirements and problems are eliminated: no sampling system is required in most applications, the uncertainty between dew and frost is eliminated, and there is no mirror that requires frequent cleaning. SPECIFICATIONS (inclding probe) HYGROFLEX 2 HYGROFLEX 3 Number of probe inputs 1 (standard) / 2 (option) Probe type Digital (HygroClip) Analog: 0...2.5V input (scalable), 15V DC, 10mA Probe calibration requires display/keypad option (probe can also be calibrated separately) Probe calibration via PC requires cable AC1623 and HW3 software Calculated parameter Dew-point, wet-bulb, enthalpy, mixing ratio, specific humidity, water vapor pressure, saturation vapor pressure. Pressure input for calculated values 1) Fixed value Fixed value or automatic with (user defined) analog pressure probe (requires 2nd probe input option) User defined calculation HygroFlex can be programmed with the HW3 software to compute and output a user defined calculation such as the difference between temperature and dew point, a difference between two dew points, etc. Transmitter measuring range 0…100%RH, -50…+200°C (-58…+392°F) Temperature limits at probe see Probe Selection Guide Accuracy (at 23°C/73°F) ± 1.0%RH ± 0.2°C (0.4°F) Repeatability ±0.3%RH and better than 0.1°C (0.2°F) Sensors Hygromer ®C94 capacitive humidity sensor, Pt100 1/3 DIN RTD Transmitter operating limits 0…99%RH non-condensing, -40…+60°C (-40…140°F), -30…+60°C with display Optional display and keypad ICD 2-line numeric, 1 line alphanumeric, 1/4" character height, membrane keypad Resolution of optional display 0.1%RH/°C/°F 0.001 calculated parameter or pressure (depends on parameter) Power 12...35VDC (300mA max.) / 12...24VAC or 90...264VAC Analog outputs N/A 3 2) Analog output type N/A 4…20mA or 0…20mA 0…1V, 0…5V, 0…10V (jumper selectable) Load limit for analog outputs N/A current outputs ≤500 ohm voltage outputs ≥1000 ohm Electrical connections for power cable - standard: 1 x for power and analog signals (power / analog outputs) cable grip, (7mm/0.275") cables - standard: 2 x cable grip, optional: 1 x 1/2" conduit adapter (7mm/0.275") optional: 2 x 1 /2"conduit adapter Connection terminals 18 AWG (power) 18 AWG (power, analog outputs) RS232 and RS485 outputs Transmitter provides data each time that a data request command is received. 5-pin receptacle common to both RS232 and RS485 – a matching 2-cable connector is provided together with the HygroFlex Test connector allows reading the measurement data and probe calibration with HygroPalm 3 indicator Housing Standard ABS housing: 207 x 150 x 59mm (8.15 x 5.90 x 2.32"), 310g (0.7 lb). Optional Aluminum housing: 245 x 135 x 75mm (9.65 x 5.32 x 2.95"), 1300g (2.86 lb) Protection grade IP65/NEMA4 CE Conformity EN580081-2, EN50082-2 Notes 1) Barometric pressure is required as an input parameter for the computation of wet bulb temperature, mixing ratio, enthalpy and specific humidity. When a fixed pressure value is used, this value can be set by the user by connecting the HygroFlex to a PC with the optional HW3 software installed. 2) Any of the 3 analog outputs of the HygroFlex 3 can be set to correspond to humidity [probe 1 or 2] or temperature [probe 1 or 2] or calculated psychrometric parameter [probe 1 or 2] or user defined calculation, or to optional analog probe signal (such as pressure). Product Summary & Technical Data Humidity goes Digital ® Ordering A Hygroflex 2 or 3 Modifications reserved Rev. 08/05/02HTS Notes 1. Calibration device: this is a small chamber that seals tightly around the tip of the probe. Using one of the available calibration standards (such as EA35-SCS), a known humidity is generated inside the calibration device. Upon reaching equilibrium with the humidity standard, the probe can be adjusted to match the value of the standard. 2. Probe simulator: plugs on the HygroFlex in lieu of the HygroClip probe to provide known fixed values for both humidity and temperature. This is useful when there is a requirement to validate the electronics of the HygroFlex. Notes 1. Output is jumper selectable and can easily be changed in the field without any required calibration. The range of the output signal (for example 0…300°F) is not affected. 2. The range of all outputs (%RH, Temperature) can be changed using the Rotronic HW3 software. 3. Enter as a separate line item the span of the calculated value along with the units of output. i.e. g/m3 or gr/ft3. 2 HygroFlex 2: digital output Notes 3 HygroFlex 3: digital and analog outputs 1 12…35 VDC / 12…24 VAC Powered 2 90…250 VAC 50-60Hz Powered A ABS enclosure M Aluminum enclosure – conduit only G = cable grips C = 1/2" conduit fittings D Digital Display and Keypad N No Digital Display 1 %RH and temperature to be displayed 2 Calculated value and %RH to be displayed 3 Calculated value and temperature to be displayed N No Digital Display Select output and enter appropriate code 1 4…20mA 3 0…1 VDC 5 0…10 VDC 1 2 0…20mA 4 0…5 VDC Select a Temperature Span from the following 1 0…100ºF 3 0…300ºF 5 0…200ºC 2 2 0…200ºF 4 0…100ºC 6 -50…150ºC Select Computed Parameter. Enter an “X” if none. 1 Dew Point 4 Absolute Humidity 7 Partial Pressure 3 2 Wet Bulb Temp.5 Mixing Ratio 8 Vapor Conc. @ sat 3 Enthalpy 6 Specific Humidity Select probe to be used. 1 IW 3 IC-3 5 IM-3 7 IC-05 2 IC-1 4 IM-1 6 IE-3 Extension cable – max. length is 656 feet X = No extension cable Enter length of extension cable in feet Enter Ordering Code To Left HTS HTS 2 3 1 2 A M G C D N E X Enter a “S” if special temperature range is desired. Also specify range as separate line on purchase order Please, also specify computed parameter range as separate line on purchase order ACCESSORIES & OPTIONS Order code: Description: Order code: Description: OUT3-16bit 16-bit D/A converter option, allows improved resolution on AC1618/XX Probe simulator (HygroFlex 3) a scale of more than 200 units on analog output 3 xx = 35%, 50%, 80%RH: 25°C/77°F HW3 HW3 configuration software ERV-15 Calibration device for type ‘IW’ probes AC1623 HygroFlex configuration cable ER-15 Calibration device for 15mm diameter probes T7-03-WIN Calibration cable HygroClip Probe to PC ER-05 Calibration device for 5mm diameter probes HygroPalm 3 HygroPalm, calibrator for HygroFlex EM-15 Calibration device for type ‘IE’ probes AC1620 Cable HygroPalm 3 to HygroFlex QMA-15 Probe adapter for HygroClip IC-3 and IM-3 EQUIVALENCE TABLE Previous Models Configuration HygroFlex and Probe HC321-W, HC322-W Wall mount HygroFlex 3 + IW probe HC321A-R, HC322-R remote probe HygroFlex 3 + IC-3 probe+ QMA-15 adapter Cal. standard, SCS Certificate, pack 5 xx = 00, 05, 10, 20, 35, 50, 65, 80 or 95 (%RH). use EA35 and EA80 for minimum calibration EAxx-SCS