Loading...
HomeMy WebLinkAboutPetra Academy Master Site Plan - First Phase Site plan No. Z-10117 and No. Z-10135.pdf1 Commission Memorandum REPORT TO: Honorable Mayor and City Commission FROM: Brian Krueger, Associate Planner Chris Saunders, Interim Planning Director Chris A. Kukulski, City Manager SUBJECT: Petra Academy Master Site Plan/First Phase Site Plan Applications (#Z- 10135 and #Z-10117) MEETING DATE: August 2, 2010 AGENDA ITEM TYPE: Action Item RECOMMENDATION: That the City Commission approve the Petra Academy Master Site Plan and First Phase Site Plan applications, #Z-10135 and #Z-10117 with the staff findings and recommended conditions of approval. BACKGROUND: The property owners Bozeman Lakes, LLC; applicant Petra Academy; and their representative Madison Engineering have submitted a Master Site Plan/ First Phase Site Plan application to the Department of Planning & Community Development. The Master Site Plan will determine the overall development plan and parking arrangement for a private school campus including: two buildings and athletic fields with common parking, circulation, and site improvements. The first phase Site Plan application will allow the new construction of an 44,557 square foot private school for K-12 students with associated site improvements to be located along Cottonwood Road due south of Bronken Park. The 25.72 acre site is zoned RMH (Residential Manufactured Home District) and falls within future planned area for the Valley West PUD. The applicant proposes to remove the entire tract from the Valley West Planned Unit Development. The Department of Planning and Community Development and the Development Review Committee (DRC) reviewed the application. The application is found to be in general compliance with the adopted Bozeman Community Plan and Title 18, BMC and conditional approval of the proposal is recommended to the City Commission with the conditions and code provisions outlined in this staff report. The recommended conditions begin on page 2 of this staff report. The recommended code provisions can be found beginning on page 5 of this staff report. The City Commission is the final approval authority for Master Site Plan applications, per Section 18.34.070.B.3 of the BMC. 79 2 UNRESOLVED ISSUES: None determined at this time. FISCAL EFFECTS: The development of a school on this property will increase tax values and corresponding revenue from the property. The City will accrue additional costs to service the property with municipal service. ALTERNATIVES: 1) Approve the applications with the findings and conditions as recommended above by Staff. 2) Approve the applications with revised findings and revised conditions as directed by the City Commission. 3) Deny the applications with findings. Attachments: Staff Report Aerial Photograph Applicant submittal materials Report compiled on: July 20, 2010 80 CITY COMMISSION STAFF REPORT PETRA ACADEMY MASP/SP FILE NOs. #Z-10135 #Z-10117 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 1 Item: A Master Site Plan Application including a first phase Site Plan. The Master Site Plan will determine the overall development plan and parking arrangement for a private school campus, including a school, field house/event center, athletic fields, common parking, circulation, and site improvements. The first phase Site Plan application will allow the new construction of a 44, 557 square foot school building with associated site improvements. Known as Petra Academy, it is to be located west of Cottonwood Road and south of Bronken Park between Durston Road and West Babcock Street. The site is legally described as Tract 1 of the Valley West Subdivision, City of Bozeman, Gallatin County, Montana. Owner: Bozeman Lakes, LLC 822 Stoneridge Drive, Suite 2 Bozeman, MT 59718 Applicant: Petra Academy 100 Discovery Drive Bozeman, MT 59718 Representative: Madison Engineering 517 South 22nd Ave., Suite 4 PO Box 1113 Bozeman, MT 59718 Date: City Commission meeting on August 2, 2010, 6:00 pm in the Commission Meeting Room, Bozeman City Hall, 121 North Rouse, Bozeman, Montana. Report By: Brian Krueger, Associate Planner Recommendation: Conditional Approval ____________________________________________________________________________________ PROJECT LOCATION The subject site is located west of Cottonwood Road and south of Bronken Park between Durston Road and West Babcock Street is legally described as Tract 1 of the Valley West Subdivision, City of Bozeman, Gallatin County, Montana. The overall site is approximately 25.72 acres in size. Please refer to the following vicinity map. 81 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 2 PROPOSAL The Master Site Plan will determine the overall development plan and parking arrangement for a private school campus including: two buildings and athletic fields with common parking, circulation, and site improvements. The first phase Site Plan application will allow new construction of an 44,557 square foot private school for K-12 students with associated site improvements to be located at along Cottonwood Road due south of Bronken Park. The 25.72 acre site is zoned RMH (Residential Manufactured Home District) and falls within future planned area for the Valley West PUD. The applicant proposes to build a new public street, Theodore Street, to access the site and to provide access to the Bronken Park parking area. The applicant has submitted a letter from the property owner and developer of the Valley West Subdivision requesting that this tract be removed from the Planned Unit Development (PUD) and acknowledges that all entitlements for this tract related to the PUD are vacated. This application is being processed without a PUD modification, as no further entitlement or dependency was determined for this tract following the requested removal from the PUD. On July 7, 2010 the Development Review Committee (DRC) recommended conditional approval of this application, their recommended conditions and comments are included in this report. RECOMMENDED CONDITIONS OF APPROVAL Based on the previous analysis, the DRC, and staff find that the application, with conditions and code provisions, is in general compliance with the adopted Growth Policy and the City of Bozeman Unified Development Ordinance. The following conditions of approval are recommended. Please note that these conditions are in addition to the required code provisions beginning on pages 5-9 of this report. 1. An original notarized letter including signatures from the Developer of the Valley West Subdivision, the current owner of the subject tract, and president of the Valley West Owner’s 82 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 3 Association shall be submitted with the final site plan reaffirming the removal of Tract 1 Block 3 of the Valley West Subdivision from the Valley West Planned Unit Development (PUD). The letter shall include at a minimum: a description of how the property owner’s association will function without the participation of the PUD area to be vacated and clear acknowledgement that any City approved entitlements to the PUD area to be vacated would no longer apply. A current (within 30 days) title report shall be submitted with the final site plan. 2. A final wetland planting plan and documentation from the Army Corps of Engineers regarding the mitigated wetland area noted on the site plan shall be provided with the final site plan application. 3. A 25’ public access easement shall be provided over the north/south gravel fines walking trail adjacent to the wetlands mitigation boundary. If the trail is not constructed from the north property line to the south property line of the subject site, it shall be with this project. A Class II trail per the construction specifications in Appendix C of the 2007 PROST Plan shall be provided for this corridor. 4. The master site plan shall be revised to show a minimum 5’ sidewalk connecting the school and future field house/event center adjacent to the parking area. 5. That the applicant upon submitting the Final Site Plan for approval by the Planning Director and prior to issuance of a building permit, will also submit a written narrative outlining how each of the above conditions of approval and code provisions have been satisfied. 6. Project phasing shall be clearly defined on the Final Site Plan and infrastructure plans and specifications including installation of infrastructure. Any proposed phasing of public infrastructure must be reviewed and approved by the City engineering office. Each phase must address paving, drainage, access and other site improvements independently prior occupancy. 7. At this time the lot being proposed for this development has not paid cash-in-lieu of water rights. Prior to development cash-in-lieu of water rights will be required to be paid. The applicant is required to produce an estimate for the annual water consumption for the facility at full build out. This water consumption rate will be reviewed by the Engineering Department to determine the final amount for cash-in-lieu of water rights. 8. A detailed Traffic Impact Study for the proposed development, including a level of service evaluation, shall be provided. 9. Unless the Commission determines the East half of Cottonwood Road adjacent to the subject parcel cannot be constructed with Phase 4 of the Master Site Plan, the improvements must be constructed with Phase 1 and be complete prior to occupancy. 10. The proposed Theodore Street shall be constructed to include full boulevard sidewalk (with boulevard trees) on the southern portion and the full roadway from back of curb to back of curb. The street design must be submitted, reviewed, and accepted by the City Engineering department prior to any construction and issuance of building permits. 11. Any dead end street or access that extends longer than 150 feet must provide an adequate 83 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 4 emergency turn-around that is approved by the Bozeman Fire Department. 12. All drive accesses shall line up directly across from any street, alley, or other drive access or be spaced a minimum of 40 feet apart. All drive accesses and street intersections on adjoining lots shall be shown on the final site plan to verify that all proposed drive accesses either line up or meet the necessary separation distance. If the applicant wishes to keep the proposed nonconforming drive accesses they must formally request them from the City Engineer. The guidelines for this request are outlined in UDO section 18.44.090.H.3. CONCLUSION/RECOMMENDATION The DRC and Staff have reviewed the Master Site Plan and first phase Site Plan Application. Staff recommends to the City Commission approval of said application with the conditions and code provisions outlined in this Staff Report. Staff has identified various code provisions that are currently not met by this application. Some or all of these items are listed in the findings of this Staff Report. The applicant must comply with all provisions of the Bozeman Unified Development Ordinance, which are applicable to this project, prior to receiving Final Site Plan approval. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. ZONING DESIGNATION & LAND USES The property is zoned RMH (Residential Manufactured Home District). The intent of the RMH district is to provide for manufactured home community development and directly related complementary uses within the City at a density and character compatible with adjacent development. North: Bronken Park, City Parkland, zoned “PLI” (Public Lands and Institutions District) South: Vacant, zone “RMH” (Residential Manufactured Home District) East: Vacant and Bronken Park, zoned “R-4” (Residential High Density District) and “PLI” West: Valley West Subdivision PUD, zoned “R-3” (Residential Medium Density District) ADOPTED GROWTH POLICY DESIGNATION The Future Land Use Map of the Bozeman Community Plan designates the subject property to develop as “Residential”. The “Residential” category designates places where the primary activity is urban density dwellings. Other uses which complement residences are also acceptable such as parks, low intensity home based occupations, fire stations, churches, and schools. High density residential areas should be established in close proximity to commercial centers to facilitate the provision of services and employment opportunities to persons without requiring the use of an automobile. Implementation of this category by residential zoning should provide for and coordinate intensive residential uses in proximity to commercial centers. The residential designation indicates that it is expected that development will occur within municipal boundaries, which may require annexation prior to development. The dwelling unit density expected within this classification varies between 6 and 32 dwellings per net acre. A higher density may be considered in some locations and circumstances. A variety of housing types can be blended to achieve the desired density. Large areas of single type housing are discouraged. 84 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 5 In limited instances the strong presence of constraints and natural features such as floodplains may cause an area to be designated for development at a lower density than normally expected within this category. All residential housing should be arranged with consideration of compatibility with adjacent development, natural constraints such as watercourses or steep slopes, and in a fashion which advances the overall goals of the Bozeman growth policy. The residential designation is intended to provide the primary locations for additional housing within the planning area. REVIEW CRITERIA & STAFF FINDINGS SECTION 18.34 “SITE PLAN AND MASTER SITE PLAN REVIEW CRITERIA” In considering applications for site plan approval under this title, the Planning Director, City Commission, DRC, and when appropriate, the ADR Staff, the DRB or WRB shall consider the following: 1. Conformance to and consistency with the City’s adopted growth policy The development proposal is in conformance with the Bozeman Community Plan including the “Residential” classification. The “Residential” category designates places where the primary activity is urban density dwellings. Other uses which complement residences are also acceptable such as parks, low intensity home based occupations, fire stations, churches, and schools. This proposal is for a school and associated accessory uses such as athletic fields and a field house. The proposal is in conformance and consistent with this designation. 2. Conformance to this title, including the cessation of any current violations The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. The following code provisions must be addressed prior to Final Site Plan approval: a) Section 18.34.090.E requires that following the approval of a final master site plan, the applicant shall submit to the Planning Department sequential individual site plan for specific areas within the master site plan. b) Section 18.34.130.D states that following approval of a final master site plan, the final master site plan shall be in effect for not more than five years. c) Section 18.34.130 requires the applicant to submit seven (7) copies a Final Site Plan within 6 months of preliminary approval containing all of the conditions, corrections and modifications to be reviewed and approved by the Planning Office. a. If occupancy of any structure is to occur prior to the installation of all required on-site improvements, the Improvements Agreement must be secured by a method of security equal to one and one-half times the amount of the estimated cost of the scheduled improvements not yet installed. Said method of security shall be valid for a period of not less than twelve (12) months; however, the applicant shall complete all on-site improvements within nine (9) months of occupancy to avoid default on the method of 85 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 6 security. d) Section 18.34.130 requires that the final site plan shall contain the materials required in 18.78.080 and 18.78.090. Specifically the final site plan shall show all utilities and utility rights-of-way or easements: (1) Electric; (2) Natural Gas; (3) Telephone, cable TV, and similar services; (4)Water; and (5) Sewer (sanitary, treated effluent and storm). e) Section 18.34.140 states that a Building Permit must be obtained prior to the work, and must be obtained within one year of Final Site Plan approval. Building Permits will not be issued until the Final Site Plan is approved. f) Section 18.38.050.F requires all mechanical equipment to be screened. Rooftop equipment should be incorporated into the roof form or screened in an enclosure and ground mounted equipment shall be screened with walls, fencing or plant materials. The final master site plan and first phase site plan shall contain a notation that “No ground mounted mechanical equipment, including, but not limited to utilities, air exchange conditioning units, transformers, and meters shall encroach into the required yard setbacks and will be properly screened with an opaque solid wall and adequate landscape features. All rooftop mechanical equipment shall be incorporated into the roof form or screened in an approved rooftop enclosure.” g) Section 18.42.100.B.6 requires a water course setback planting plan for all watercourses. A watercourse setback planting plan shall be provided for the watercourse along Cottonwood Road with the final site plan. h) Sections 18.42.150 requires a lighting plan for all on-site lighting including wall-mounted lights on the building must be included in the final site plan submittal. Clarify that all proposed parking lot and site lighting do not exceed the maximum allowed 25 foot pole height. A photometric plan shall be submitted to assure compliance with this code section. i) Section 18.42.150.D.7 requires that all site lighting other than pathway intersection lighting and security lighting all lighting shall be turned off between 11:00 p.m. and 6:00 a.m. Exceptions shall be granted to those businesses which operate during these hours; such lighting may remain illuminated only while the establishment is actually open for business. j) Section 18.42.170 states the size of the trash receptacle shall be appropriately sized for the use and approved by the City Solid Waste Division. Accommodations for recyclables must also be considered. All receptacles shall be located inside of an approved trash enclosure. A copy of the site plan, indicating the location of the trash enclosure, dimensions of the receptacle and enclosure and details of the materials used, shall be sent to and approved by the City Solid Waste Division (phone: 582-3238) prior to final site plan approval. k) Section 18.46.020.A requires a minimum accessible stall length of 20 feet, 18 feet if measured from a curb where at least 2 ft. of overhand onto landscaping area or a minimum 5 ft. sidewalk is provided or 18 feet measured from a wheel stop where an additional 2 ft. of overhang exists. A minimum 5’ aisle shall be provided next to each accessible stall. l) Section 18.46.020.L states that concrete sidewalks a minimum of 3 feet in width shall be provided between any existing or proposed building and adjacent parking lot. Where sidewalks curbs 86 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 7 serve as wheel stops, an addition 2 feet of sidewalk width is required. The final master site plan shall reflect a minimum 5’ sidewalk connecting the school building and future field house/events center adjacent to the parking lot. m) Section 18.46.040.D states that disabled accessible spaces shall be located as near as practical to a primary entrance. Parking spaces and access aisles shall be level with slopes not exceeding 1:50 in all directions. Raised signs shall be located at a distance no greater than five feet from the front of each accessible space and shall state “Permit Required $100 Fine”. One of the disabled accessible spaces shall also be signed “Van Accessible”. The “Van Accessible” space shall be 8 feet wide with an 8 foot wide striped unloading aisle. n) Section 18.46.040.E, requires that bicycle parking be provide. A bicycle parking location to accommodate all the required spaces shall be specified on the final site plan. o) Section 18.48.050.C.2.A requires that parking lots must be screened from the public street (Cottonwood Road and Theodore Street). The screening required shall not be less than 4 feet in width and shall be maintained at a height of 4 to 6 feet except as otherwise restricted by fence and hedge height limits within required front yards and street vision triangles. p) Section 18.48.050.L requires that the finish grade of all landscape areas including stormwater facilities shall not exceed a slope of 25% grade (4 run: 1 rise). q) Section 18.48.050.L requires that all stormwater retention/detention facilities to be designed as landscape amenities. See specific code section for specific language and requirements. A cross section and landscape detail of each facility that meets the requirements of this section shall be submitted with the final landscape plan. r) Section 18.52.060.C outlines the amount of permitted signage for the property. A Sign Permit shall be reviewed and approved by the Planning Office prior to the construction and installation of any on-site signage. All final building elevations and site plans shall show the signage allowed in compliance with this section. s) Section 18.64.100 states that a building permit shall be obtained within one year of final approval, or said approval shall become null and void. Prior to the lapse of one year, the applicant may seek an extension of one additional year from the Planning Director. t) Section 18.74.030.C.1.c outlines the requirements for site plan concurrent construction. Items 1- 4 of this section shall be satisfied prior to concurrent construction of water mains, sewer mains, public streets and private building improvements. u) The Final Site Plan shall be adequately dimensioned. A complete legend of all line types used shall also be provided. v) A Storm Water Drainage/Treatment Grading Plan and Maintenance Plan for a system designed to remove solids, silt, oils, grease, and other pollutants must be provided to and approved by the City Engineer. The plan must demonstrate adequate site drainage (including sufficient spot elevations), storm water detention/retention basin details (including basin sizing and discharge 87 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 8 calculations, and discharge structure details), storm water discharge destination, and a storm water maintenance plan. w) Plans and Specifications for any fire service line must be prepared in accordance with the City's Fire Service Line Policy by a Professional Engineer (PE), and be provided to and approved by the City Engineer prior to initiation of construction of the fire service or fire protection system. The applicant shall also provide Professional Engineering services for construction inspection, post-construction certification, and preparation of mylar record drawings. x) If construction activities related to the project result in the disturbance of more than 1 acre of natural ground, an erosion/sediment control plan may be required. The Montana Department of Environmental Quality, Water Quality Bureau, shall be contacted by the Applicant to determine if a Storm Water Discharge Permit is necessary. If required by the WQB, an erosion/sediment control plan shall be prepared for disturbed areas of 1 acre or less if the point of discharge is less than 100' from State Waters. y) Sewer and water services shall be shown on the FSP and approved by the Water/Sewer Superintendent. City of Bozeman applications for service shall be completed by the applicant z) Adequate snow storage area must be designated outside the sight triangles, but on the subject property (unless a snow storage easement is obtained for a location off the property and filed with the County Clerk and Recorder's office). aa) Drive approach and public street intersection sight triangles shall be free of plantings which at mature growth will obscure vision within the sight triangle. bb) Plans and specifications for any water, sewer and/or storm sewer main extensions, and Public or Private Streets (including curb, gutter & sidewalks) prepared by a Professional Engineer (PE) shall be provided to and approved by the City Engineer. Water and sewer plans shall also be approved by the Montana Department of Environmental Quality. The applicant shall also provide Professional Engineering services for construction inspection, post-construction certification, and preparation of mylar record drawings. Specific comments regarding the existing and proposed infrastructure shall be provided at that time. Construction shall not be initiated on the public infrastructure improvements until the plans and specifications have been approved and a pre-construction conference has been conducted. cc) Site Plan Concurrent Construction has been requested for this project. However, no building permits will be issued prior to City acceptance of the infrastructure design and, plans & specifications. dd) City standard sidewalk shall be installed and properly depicted at the standard location (i.e., 1 foot off property line) along the street(s) frontage. Any deviation to the standard alignment or location must be approved by the City Engineer. ee) The drive approaches shall be constructed in accordance with the City's standard approach (i.e., concrete apron, sidewalk section and drop-curb) and shown as such on the FSP. 88 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 9 ff) Typical curb details (i.e., raised and/or drop curbs) and typical asphalt paving section detail shall be provided to and approved by the City Engineer. Concrete curbing shall be provided around the entire new parking lot perimeter and adequately identified on the FSP. gg) All trees must be at least 10 feet from any public utilities or service lines. All public utilities and services lines must be shown on the Final Landscaping plan. hh) The location of existing water and sewer mains shall be properly depicted, as well as nearby fire hydrants. Proposed main extensions shall be labeled "proposed". ii) Easements for any water and sewer main extensions shall be a minimum of 30 feet in width, with the utility located in the center of the easement. In no case shall the utility be less than 10 feet from edge of easement. jj) The Montana Department of Fish, Wildlife & Parks, SCS, Montana Department of Environmental Quality and Army Corps of Engineer's shall be contacted regarding the proposed project and any required permits (i.e., 310, 404, Turbidity exemption, etc.) shall be obtained prior to FSP approval. kk) The applicant shall submit a construction route map dictating how materials and heavy equipment will travel to and from the site in accordance with section 18.74.020.A.1 of the Unified Development Ordinance. This shall be submitted as part of the final site plan for site developments, or with the infrastructure plans for subdivisions. It shall be the responsibility of the applicant to ensure that the construction traffic follows the approved routes. ll) All construction activities shall comply with section 18.74.020.A.2. of the Unified Development Ordinance. This shall include routine cleaning/sweeping of material that is dragged to adjacent streets. The City may require a guarantee as allowed for under this section at any time during the construction to ensure any damages or cleaning that are required are complete. The developer shall be responsible to reimburse the City for all costs associated with the work if it becomes necessary for the City to correct any problems that are identified. mm) A grease interceptor conforming to the latest adopted edition of the Uniform Plumbing Code shall be installed with any development responsible for food preparation. In accordance with Municipal Code, on-site maintenance and interceptor service records shall be kept on a regular basis and made available to the City upon request. 3. Conformance with all other applicable laws, ordinances, and regulations The Final Site Plan will be reviewed to ensure compliance with this section. The proposal conforms to all other applicable laws, ordinances, and regulations. The plans will be further evaluated against the requirements of the International Building Code at the time application is made for a Building Permit. 4. Relationship of site plan elements to conditions both on and off the property Existing- The subject property is undeveloped. The west side of Cottonwood Road is constructed in its final location. The access to the parking area at Bronken Park is the only street 89 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 10 access in this portion of Cottonwood Road. The current access road (future Theodore Street)is unfinished road base. Proposed- The Master Site Plan will determine the overall development plan and parking arrangement for a private school campus, including a school, field house/event center, athletic fields, common parking, circulation, and site improvements. The first phase Site Plan application will allow the new construction of a 44, 557 square foot school building with associated site improvements. The proposal includes the construction of Theodore Street west from the Cottonwood Road access to Bronken Park. This street will be constructed to local standards connecting to the existing paved parking areas for Bronken Park. The access to the school property is proposed from the new local street. No direct access to the school or future field house/event center is proposed. The master site plan proposal includes an extension of the parking area south to the parking and circulation areas to support a field house/event center that will be include in a future phase. In total 4 phases are proposed. First, construction of the school building and associated parking; Second, phases II and II include the addition of class room space and additional parking areas; finally Phase IV would include the addition of a field house/event center and associated parking. The final phase would include a connection back to Cottonwood Road for secondary access to the site. The development of athletic fields are proposed with all phases. The west side of the proposed Petra Academy site includes a substantial wetland mitigation area that was installed by the Valley West developers in 2009. The mitigation was required by the Army Corps of Engineers for wetland fill in the Valley West Subdivision east of Cottonwood Road. Although the mitigation work is complete, the area continues to be monitored, as required by the permit from the Army Corps. 5. The impact of the proposal on the existing and anticipated traffic and parking conditions The applicant proposes to construct a new public street that will serve as a local street that would access Cottonwood Road. For this first phase of development all traffic from this proposed site would directly access the new local street, and no direct access would be allowed from this site onto Cottonwood Road. The new local street would be located between the proposed development and Bronken Park and would not be a through street. Three parcels on the east side of Cottonwood Road have received variances to not improve Cottonwood Road to standard principal arterial standards. Another parcel on the east side of Cottonwood Road has been conditioned that their frontage of Cottonwood Road shall be improved to standard principal arterial standards prior to completion of the final phase of the development. A total of 199 parking stalls including 7 accessible spaces are provided on site with the first phase school construction. Based upon the calculation provided by the applicant for school uses proposed on site this appears to be acceptable. The final master plan required parking will be based upon the actual uses and floor plans proposed for the school additions and future field house/event center. The parking areas are divided into separate lot areas that help to minimize the negative visual aspects of parking on site. The parking is provided to the side and behind the buildings located on the public ways. 90 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 11 Staff has noted a code provision regarding the accessible parking provided on site. Conformance with the dimensional standards of this section including location of accessible aisles will be required with the final site plan. 6. Pedestrian and vehicular ingress and egress The primary entrance, for both pedestrians and vehicles, to the development is from Theodore Street via Cottonwood Road. A future secondary access will be developed to Cottonwood Road with Phase IV. The proposal includes the development of sidewalks on Cottonwood Road and Theodore Street, both with standard 5’ width and a 5.5’ boulevard planting strip for the project frontage. A dedicated and crosswalk protected pedestrian route is provided from Theodore Street to the front entrance of the building. As vehicular student drop off is anticipated on site, a safe and dedicated drop off zone at the front of the school building is proposed. There are sidewalks present between the building and all parking areas providing safe pedestrian ingress to the building. 7. Landscaping, including the enhancement of buildings, the appearance of vehicular use, open space, and pedestrian areas, and the preservation or replacement of natural vegetation The landscape design is required to meet the standard of 23 points. The landscape plan currently designates that those points are met on site. Staff notes in the code provisions that the required parking lot landscape screening is deficient and will have to be address on the final site plan. The proposed berm planned along Cottonwood road exceeds the slope requirements of the code and the specific species and planting numbers or spacing are not identified. Staff has noted code provisions for these items that will be required to be satisfied with the final site plan submittal. The final landscape plan will be reviewed during final site plan review for conformance with the requirements of Chapter 18.48 BMC. 8. Open space The existing open space on site is located along the western side of the property. As this is wetland mitigation area, it shall be retained and maintained by the Petra Academy. The site also includes a tributary to Baxter Creek, along Cottonwood Road. A setback is required from this stream corridor that should protect the open space character of this natural feature.. In addition to the landscaped yard spaces, wetland mitigation areas and stream corridors, open spaces are proposed in the form of athletic fields on site. 9. Building location and height The school building and future field house/events center are sited such that they respect all setbacks required in the RMH zoning district. The buildings are also located such that they are outside of the 50’ setback required from the watercourse along Cottonwood Road. The parking 91 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 12 and circulation areas are outside of the required setbacks from Theodore Street and Cottonwood Road. The only building that has been fully designed for the site is the initial Petra Academy school building, which is proposed at approximately 31.6 feet at its maximum height. The maximum height allowed in the RMH zone with the proposed roof configuration is 24 feet. Section 18.38.060.D.2 allows additional height allotments for places of public assembly in churches, schools, and other permitted public and semipublic buildings. The section allows an additional 1 foot in height per additional 1 foot of setback to the side and rear yards required in the district. The proposal exceeds the side and rear yard setbacks by more than the 7.5 additional feet required for the proposed gymnasium at 31.6 feet in height. 10. Setbacks The yard setbacks in the RMH district adjacent to arterial streets (Cottonwood Road) are 25 feet minimum for buildings, parking, and driveway circulation areas. This setback is immaterial to this project because the Baxter Creek tributary watercourse exists in the vicinity which increases the setback to 50’ from the high water line of the water course. The school and parking areas are outside of this watercourse setback area. The property’s designated front yard is on a local street (Theodore Street) and there is a 15 ft. setback along that street for buildings and parking areas. The side and rear yard lines are not applicable as they would be considered in the wetland mitigation area along the western property line, a side yard along Cottonwood Road, and the rear property line to the south. None of these areas is proposed to be close to building areas. A 50’ wetlands setback exists from the wetland mitigation area and no buildings or athletic fields are planned in this area. The project meets all required setbacks. 11. Lighting The light fixture details appear to meet the lighting standards. All lighting fixtures must be noted on the final site plan including wall-mounted lighting and any proposed security lighting. All light fixtures shall conform to the requirements outlined in the City of Bozeman Unified Development Ordinance. Additionally, the pole style light must identify the maximum pole height and a final photometric lighting plan must be submitted for the entire site with the final site plan. Staff has noted a code provision that all site lighting other than security lighting must be turned off between the hours of 11:00 p.m. and 6:00 a.m. 12. Provisions for utilities, including efficient public services and facilities The private utilities and water services are located within adjacent streets. The applicant will extend a water main down Theodore Street to service the building and to provide a fire hydrant on Theodore to service the area. Sewer service is located in Cottonwood Road and will be brought into the site from the east. The applicant will need to coordinate with Northwest Energy, Qwest, or other private providers for other services. The utilities and easements need to be coordinated with the landscape plan to ensure no overlap. No trees are permitted within ten feet of mains and services as noted in the conditions. All final utility locations, both public and private are required to be shown on the final site plan for final approval. 13. Site surface drainage 92 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 13 Stormwater retention and detention is proposed to be satisfied with an underground pipe system installed beneath the parking areas within the site that will be collected in a large stormwater retention/detention pond located at the northwest corner of the site adjacent to the northernmost athletic field. Stormwater runoff calculations will be required as part of the Final Site Plan and any needed grading for stormwater must be provided. Staff notes code provisions in this report that require that the pond be landscaped as an amenity, meet naturalized planting requirements, and include slopes no greater than 25% grade (4’ run: 1’ rise). 14. Loading and unloading areas The applicant has proposed a loading zone area for students for both drop off and pick up. The area reserved for unloading is sized to accommodate multiple vehicles and provides safe ingress and egress to and from the site. 15. Grading Some grading will be required on site. The site generally slopes from south to north. The Engineering Department has found the preliminary grading and drainage plan generally acceptable. A final grading and drainage plan with final calculations is required for review and approval by the City Engineering Department prior to final site plan approval. 16. Signage All new signage shall require a sign permit and shall be included with the Final Site Plan submittal. Staff notes a code provision that requires all signs proposed to be in conformance with the underlying RMH zoning. All final exhibits in the final site plan shall show all signage in conformance with the signage requirements of the district. 17. Screening Staff has noted a code provision that requires all mechanical equipment to be screened. The final master site plan and first phase site plan shall contain a notation that “No ground mounted mechanical equipment, including, but not limited to utilities, air exchange conditioning units, transformers, and meters shall encroach into the required yard setbacks and will be properly screened with an opaque solid wall and adequate landscape features. All rooftop mechanical equipment shall be incorporated into the roof form or screened in an approved rooftop enclosure.” Staff also notes that parking lot screening has not been satisfied along Theodore Street. The final landscape plan submitted with the final site plan shall reflect the screening for the parking areas as required. 18. Overlay district provisions Not applicable. The site is not within an Overlay District. 19. Other related matters, including relevant comment from affected parties 93 #Z-10117 #Z-10135 Petra Academy MASP/SP Staff Report 14 No public or agency comment has been received to date. 20. If the development includes multiple lots that are interdependent for circulation or other means of addressing requirement of this title, whether the lots are either: a. Configured so that the sale of individual lots will not alter the approved configuration or use of the property or cause the development to become nonconforming; b. The subject of reciprocal and perpetual easements or other agreements to which the City is a party so that the sale of individual lots will not cause one or more elements of the development to become nonconforming. Not applicable. The development is proposed on one tract of land. Attachments: Applicant’s Submittal Materials Aerial exhibit Report Sent to: Madison Engineering, 517 South 22nd Avenue, Ste. 4 Bozeman, MT 59718 Petra Academy, 100 South Discovery Drive Bozeman, MT 59718 Bozeman Lakes, LLC, 822 Stoneridge Dr. Ste. 2 Bozeman, MT 59718 94 DURSTON RD COTTONWOOD RD FALLON ST W BABCOCK ST RESORT DR ROSA WAY WATERS ST CLIFDEN DR COTTONWOOD RD BEMBRICK ST RAVALLI ST FLANDERS MILL RD COVER ST STAFFORD AVE ALEXANDER ST BENEPE ST CASCAD E S T PERRY S T MONROE ST BRENDEN ST BRISBIN ST PALISADE DR HANLEY AVE FORBES AVE BROOKSIDE LN CLIFDEN DR C A SCADE ST 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 FLOOR PLANA1SHEET TITLE:SHEET NUMBER:PROJECT: AS114THIS DRAWING IS CLASSIFIED ASPART OF AN UNPUBLISHEDCOLLECTION OF VISUAL ART.UNDER THE 1978 COPYRIGHTACT, IT IS AN EXCLUSIVEORIGINAL WORK OFAUTHORSHIP. NONE OF THEPICTORIAL, GRAPHIC ORTECHNICAL CHARTS ORDRAWINGS DEPICTED ON THISSHEET MAY BE REPRODUCED ORTRANSMITTED IN ANY FORM ORBY ANY MEANS WITHOUT THEEXPRESS PRIOR WRITTENPERMISSION OF THE ARCHITECT.THIS PLAN IS PRODUCED ONLYFOR THIS PROJECT ON THIS SITEAND MAY NOT BE USED ATOTHER LOCATIONS.DO NOT SCALE DRAWING ORIGINAL ISSUE: PreliminaryBOZEMAN, MTPROJECT:PETRA ACADEMYDANIEL COOK ARCHITECT ! 2909 WASHINGTON BLVD - OGDEN, UT 84401 ! PH: 800-552-7137 ! www.BGWSERVICES.comSITE SUBMIAL CITY OF BOZEMAN NWDR50'-0"84'-0"74'-0"88'-0" ELECTRICAL PANEL LOCATION SPRINKLER RISER LOCATION WATER HEATER ELEMENTARY PLAYGROUND HALF WALLW/ GLASSSEATING 288 FUTURE CAFETERIA 132 SEATS 1975 SF ORCHESTRA SOUND BOOTH ALARMEDDOOR 4,692 SF ATRIUM AREAD.F. D.F. D.F.LCD MONITORSBULLETINBOARDR.R. A: 64SqFt R.R. A: 54SqFt R.R. A: 66SqFt WOMEN A: 325SqFt MEN A: 268SqFt WOMEN'S AREA: 345SqFt MEN'S AREA: 212SqFt STORAGE A: 136SqFt PRE-K A: 498SqFt 25'-9" x 19'-11" ART/ LATIN A: 403SqFt20'-3" x 19'-11" KINDERG A R T E N A: 537SqF t29'-6" x 19' - 1 1 " 11TH GRADE A: 397SqFt 19'-11" x 19'-11" 12TH GRADE A: 411SqFt20'-8" x 19'-11" CLASSRO O M A: 383SqFt22'-9" x 16' - 5 " 7TH GRA D E A: 392SqF t 19'-8" x 19 ' - 1 1 " 8TH GRA D E A: 396SqFt19'-11" x 1 9 ' - 1 1 " 9TH GRA D E A: 396SqFt19'-11" x 1 9 ' - 1 1 " 10TH GR A D E A: 396SqF t19'-11" x 19 ' - 1 1 " P.E. OFFICE A: 154SqFt15'-5" x 10'-0" GYMNASIUM A: 7,126SqFt104'-0" x 67'-11" CONFERENCE A: 191SqFt 16'-6" x 11'-6" RECEPT A: 265SqFt 14'-10" x 17'-0" WORK A: 400SqFt12'-10" x 30'-5" GARMENT ROOM A: 612SqFt 19'-1" x 30'-4" PLATFORM A: 628SqFt31'-0" x 21'-0" ATRIUM A: 3,178SqFt59'-11" x 46'-0" FLEX SPACE A: 2,106SqFt FLEX SPACE A: 1,857SqFt PERFORMANCE HALL A: 3,194SqFt59'-11" x 45'-0"TEACHER'S LOUNGE/ STORAGE A: 242SqFt LAB A: 486SqFt24'-5" x 19'-11" LIBRARY/ COMPUTER CENTER A: 1,134SqFt 25'-7" x 40'-4" 3RD GRA D E A: 544SqF t 25'-8" x 21'- 5 " 2ND GRA D E A: 547SqFt25'-7" x 21' - 5 " 1ST GRA D E A: 554SqFt27'-8" x 21' - 5 " 6TH GRADE A: 442SqFt 20'-8" x 21'-5" 5TH GRADE A: 441SqFt 20'-7" x 21'-5" 4TH GRADE A: 440SqFt 20'-7" x 21'-5" BACKSTAGE A: 967SqFt DRESSING A: 108SqFtDRESSING A: 107SqFt GREEN ROOM A: 108SqFt12'-7" x 8'-7" R.R. A: 55SqFt BLEACHERS A: 2,600SqFt 104'-0" x 25'-0" VEST A: 191SqFt 13'-0" x 14'-8" VEST A: 91SqFt 8'-0" x 11'-5" WARMING KITCHEN A: 341SqFt 10'-9" x 32'-6" CONCESSIONS A: 189SqFt18'-10" x 10'-0" VEST A: 197SqFt21'-0" x 9'-5" STORAGEA: 268SqFt15'-5" x 17'-5"STORAGEA: 615SqFt25'-2" x 24'-5"STORAGEA: 609SqFt25'-0" x 24'-5"MDP A: 83SqFtSPKLR A: 56SqFt OFFICE A: 123SqFt 11'-8" x 10'-6" OFFICE A: 123SqFt 11'-8" x 10'-6" OFFICE A: 123SqFt 11'-8" x 10'-6" OFFICE A: 123SqFt 11'-8" x 10'-7" TRAINING AREA: 680SqFt 27'-9" x 24'-6"LOCKERSAREA: 245SqFtSHOWERS AREA: 129SqFt UTILITY A: 108SqFt SHOWERS AREA: 129SqFt LOCKERS AREA: 321SqFt A: 3,087 SqFt F400 RETRACTABLE BLEACHER SEATING @ 24" BOY'S A: 110SqFt JAN A: 54SqFt JAN A: 83SqFt GIRL'S A: 184SqFt Total Building - 44,557 SF Total Building w/ Canopies - 47,861 SF F L O O R P L A N SCALE: 1/16" = 1'-0" 129 Exterior ElevationsA2SHEET TITLE:SHEET NUMBER:PROJECT: AS114THIS DRAWING IS CLASSIFIED ASPART OF AN UNPUBLISHEDCOLLECTION OF VISUAL ART.UNDER THE 1978 COPYRIGHTACT, IT IS AN EXCLUSIVEORIGINAL WORK OFAUTHORSHIP. NONE OF THEPICTORIAL, GRAPHIC ORTECHNICAL CHARTS ORDRAWINGS DEPICTED ON THISSHEET MAY BE REPRODUCED ORTRANSMITTED IN ANY FORM ORBY ANY MEANS WITHOUT THEEXPRESS PRIOR WRITTENPERMISSION OF THE ARCHITECT.THIS PLAN IS PRODUCED ONLYFOR THIS PROJECT ON THIS SITEAND MAY NOT BE USED ATOTHER LOCATIONS.DO NOT SCALE DRAWING ORIGINAL ISSUE: PreliminaryBOZEMAN, MTPROJECT:PETRA ACADEMYDANIEL COOK ARCHITECT ! 2909 WASHINGTON BLVD - OGDEN, UT 84401 ! PH: 800-552-7137 ! www.BGWSERVICES.comSITE SUBMIAL CITY OF BOZEMAN 20'-6" 0" 15'-7" 22'-0" 26'-8" 31'-6" 0" 12'-0" 17'-6" 20'-6" 26'-8" 31'-6" 0" 20'-0"20'-6" 0" 15'-7" 12'-0" 26'-8"22'-0" 22'-0" 0" 15'-7" 26'-8" 20'-0" 0" 12'-0" 31'-6" 26'-8" 0" 15'-7" 20'-6" 0" 15'-7" 31'-6" E A S T E L E V A T I O N SCALE: 1/16" = 1'-0" N O R T H E L E V A T I O N SCALE: 1/16" = 1'-0" S O U T H E L E V A T I O N SCALE: 1/16" = 1'-0" W E S T E L E V A T I O N SCALE: 1/16" = 1'-0" 130