HomeMy WebLinkAboutGallatin Valley Seed Company - Greater Yellowstone Coalition CUP and COA with Deviations Commission Memorandum TO: Honorable Mayor and City Commission FROM: Allyson C. Bristor, Associate Planner SUBJECT: Gallatin Valley Seed Company/ Greater Yellowstone Coalition CUP/COA/DEV - #Z-09092 HEARING DATE: Monday, July 6, 2009 at 6:00 p.m. RECOMMENDATION: That the Commission approve the Gallatin Valley Seed Company/ Greater Yellowstone Coalition Conditional Use Permit (CUP) and Certificate of Appropriateness (COA) with a deviations application, #Z-09092, as conditioned. BACKGROUND: The Greater Yellowstone Coalition (GYC), and their representatives CTA Architects Engineers, submitted a Conditional Use Permit (CUP) and Certificate of Appropriateness (COA) with deviations application to the Department of Planning & Community Development. The proposal is to establish GYC’s office headquarters in Building C of the Gallatin Valley Seed Company complex, which is approximately 9,000 square feet in size. The proposal does not result in any change of uses for Buildings A and B of the complex. The applicant and representative submitted an informal application prior to the formal CUP/COA application. The primary emphasis of the informal review was to see if City Staff would be acceptable to a parking deviation for the proposal, and if Staff would be acceptable to the applicant submitting a CUP application rather than a Zoning Map Amendment (ZMA) application for the formal review process. The applicant and representative had the choice of a ZMA because of the recent adoption of the Bozeman Community Plan (June 1, 2009), which designates the Gallatin Valley Seed Company property as “Community Core.” The property was designated as “Residential” in the previous Bozeman 2020 Plan. A ZMA application could have requested a change to commercial zoning (likely “B-3,” Central Business District), which is appropriate for the “Community Core” designation. Following a change in zoning, the applicant would have been responsible to submit a Site Plan/COA application to permit the actual site development and building rehabilitation. A combination of office, warehouse and residential uses were approved in a CUP application for the Gallatin Valley Seed Company property in 1994. Warehouse use was approved in Building C with that application. Because the current proposal is seeking to expand a lawful nonconforming nonresidential use (office), it must be approved through the granting of a CUP by the City Commission (per Section 18.60.020, “Changes To or Expansions of Nonconforming Uses,” of the Unified Development Ordinance). The current CUP/COA application requested one deviation from Section 18.46.040, “Number of Parking Spaces Required,” to allow a reduction in the parking demand, up to 12 spaces, for the proposal. One additional deviation was found during the preliminary review of the project. The deviation is from Section 18.38.060, “Yard and Height Encroachments, Limitations, and Exceptions,” and is to allow a portion of the covered exterior deck proposed on the south elevation to encroach into the required 15-foot front yard setback along Curtiss Street. The deviation is specifically for a 2’ x 21’ area (42 square feet) of the covered deck. The application was reviewed by Administrative Design Review (ADR) Staff throughout the application process. The Development Review Committee (DRC) completed their three-week review of the project 287 Report compiled on July 1, 2009 on June 24, 2009 and recommended approval of the proposal as conditioned by Staff. The Design Review Board (DRB) completed reviewed the project on June 24, 2009 and also recommended approval of the proposal. The DRB draft minutes are not available at the time of this report. The Historic Preservation Advisory Board (HPAB) reviewed the project on June 25, 2009 and recommended approval of the proposal with an additional condition of approval (see below). The standard review authority for CUP/COA applications with deviations is the Board of Adjustment (BOA). However, the project is dealing with the expansion of a lawful nonconforming nonresidential use (office). This type of expansions may be expanded only through the granting of a CUP by the City Commission. UNRESOLVED ISSUES: Staff is not aware of any unresolved issues for this proposed development at this time. FISCAL EFFECTS: Staff is not aware of any fiscal effects at this time. ALTERNATIVES: As suggested by the City Commission. CONTACT: Please email Allyson Bristor at abristor@bozeman.net if you have any questions prior to the public hearing. APPROVED BY: Andrew Epple, Planning Director Chris Kukulski, City Manager 288 CITY COMMISSION STAFF REPORT GALLATIN VALLEY SEED COMPANY / GREATER YELLOWSTONE COALITION CUP/COA/DEV #Z-09092 #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 1 Item: Zoning Application #Z-09092, a Conditional Use Permit and Certificate of Appropriateness application with deviations, to allow the following alterations to the historic Gallatin Valley Seed Company property, addressed on the 200 block of S. Wallace Avenue: (1) allow Building C to change from warehouse to office use for the Greater Yellowstone Coalition, (2) demolition of a connector between Buildings B and C and rehabilitation/remodel of Building C to accommodate the office use, (3) addition of a covered and uncovered exterior deck on the south elevation of Building C, (4) addition of a ADA accessible ramp on the south elevation of Building C, (5) improvements to the existing surface parking areas on the property, and (6) other related site improvements including new landscaping. The property is zoned as R-4 zoning (Residential High Density District) and is located within the Neighborhood Conservation Overlay District. Property Owner: Gallatin Valley Seed Company, Inc. c/o Lowell Springer 201 S. Wallace Avenue Bozeman, MT 59715 Applicant: Greater Yellowstone Coalition PO Box 1874 Bozeman, MT 59771 Representative: CTA Architects Engineers, Inc. 1143 Stoneridge Drive Bozeman, MT 59718 Date: City Commission public hearing on Monday, July 6, 2009 at 6:00 p.m. in the City Commission Room, Bozeman City Hall, 121 North Rouse Avenue, Bozeman, Montana. Report By: Allyson C. Bristor, Associate Planner Recommendation: Conditional Approval ____________________________________________________________________________________ LOCATION The Gallatin Valley Seed Company complex consists of three structures and is located between East Olive and East Curtiss Streets, on the west side of South Wallace Avenue. The property is addressed as 201, 209 and 215 South Wallace and is legally described as Lots 11-20, Block D, Rouse’s First Addition, City of Bozeman, Gallatin County, Montana. The property is zoned as R-4 (High Density Residential District) and is located within the Neighborhood Conservation Overlay District. The Gallatin Valley Seed Company property is individually listed on the National Register of Historic Places, due to its association with Gallatin Valley’s seed pea industry from the late 1910s through the 1940s. The historic complex is composed of the seed plant (Building B) and two warehouses (Buildings A and C). The wood-frame and metal covered seed plant and brick-veneer warehouse (Building A and B) were built in c. 1917 as detached buildings. The seed plant was likely built first because it was where the peas were cleaned and sorted. The long, 289 wood-frame and metal covered warehouse (Building C) was built c. 1945 south of the seed plant and is listed non- contributing to the historic site. All of the buildings are now attached with framed-in walkways. PROPOSAL & BACKGROUND The Greater Yellowstone Coalition (GYC), and their representatives CTA Architects Engineers, submitted a Conditional Use Permit (CUP) and Certificate of Appropriateness (COA) with deviations application to the Department of Planning & Community Development. The proposal is to establish GYC’s office headquarters in Building C of the Gallatin Valley Seed Company complex, which is approximately 9,000 square feet in size. The proposal does not result in any change of uses for Buildings A and B of the complex. The applicant and representative submitted an informal application prior to the formal CUP/COA application. The primary emphasis of the informal review was to see if City Staff would be acceptable to a parking deviation for the proposal, and if Staff would be acceptable to the applicant submitting a CUP application rather than a Zoning Map Amendment (ZMA) application for the formal review process. The applicant and representative had the choice of a ZMA because of the recent adoption of the Bozeman Community Plan (June 1, 2009), which designates the Gallatin Valley Seed Company property as “Community Core.” The property was designated as “Residential” in the previous Bozeman 2020 Plan. A ZMA application could have requested a change to commercial zoning (likely “B-3,” Central Business District), which is appropriate for the “Community Core” designation. Following a change in zoning, the applicant would have been responsible to submit a Site Plan/COA application to permit the actual site development and building rehabilitation. A combination of office, warehouse and residential uses were approved in a CUP application for the Gallatin Valley Seed Company property in 1994. Warehouse use was approved in Building C with that application. Because the current proposal is seeking to expand a lawful nonconforming nonresidential use (office), it must be approved through the granting of a CUP by the City Commission (per Section 18.60.020, “Changes To or Expansions of Nonconforming Uses,” of the Unified Development Ordinance). The current CUP/COA application requested one deviation from Section 18.46.040, “Number of Parking Spaces Required,” to allow a reduction in the parking demand, up to 12 spaces, for the proposal. One additional deviation was found during the preliminary review of the project. The deviation is from Section 18.38.060, “Yard and Height Encroachments, Limitations, and Exceptions,” and is to allow a portion of the covered exterior deck proposed on the south elevation to encroach into the required 15-foot front yard setback along Curtiss Street. The deviation is specifically for a 2’ x 21’ area (42 square feet) of the covered deck. The application was reviewed by Administrative Design Review (ADR) Staff throughout the application process. The Development Review Committee (DRC) completed their three-week review of the project on June 24, 2009 and recommended approval of the proposal as conditioned by Staff. The Design Review Board (DRB) completed reviewed the project on June 24, 2009 and also recommended approval of the proposal. The DRB draft minutes are not available at the time of this report. The Historic Preservation Advisory Board (HPAB) reviewed the project on June 25, 2009 and recommended approval of the proposal with an additional condition of approval (see below). The standard review authority for CUP/COA applications with deviations is the Board of Adjustment (BOA). However, the project is dealing with the expansion of a lawful nonconforming nonresidential use (office). This type of expansions may be expanded only through the granting of a CUP by the City Commission. RECOMMENDATION & CONDITIONS OF APPROVAL ADR Staff, and the DRC, DRB, and HPAB, reviewed the Gallatin Valley Seed Company/Greater Yellowstone CUP and COA application with deviations. As a result, all recommend to the City Commission approval of the proposal with the conditions and code provisions outlined in this staff report. Planning Staff has identified various code provisions that are currently not met by this application. Some or all of these items are listed in the #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 2 290 findings of this staff report. The applicant must comply with all provisions of the Bozeman Municipal Code, which are applicable to this project, prior to the commencement of use. Planning Conditions 1. The Montana Architectural and Historic Inventory/National Register file of the Gallatin Valley Seed Company property shall be corrected and updated prior to the issuance of a building permit. The corrections and updates should reflect changes that have occurred to the site since the property’s initial listing on the National Register of Historic Places, as well as the proposed alterations to Building C. 2. A copy of all information obtained during the cataloguing of Building C’s interior shall be submitted to the Department of Planning. 3. A detailed construction schedule shall be included with the final site plan submittal. 4. Concrete pindown wheel stops shall be required to be installed in all locations that perimeter curbing does not exist or is not proposed. 5. All holes or damaged areas of the parking lot surfacing shall be repaired. 6. One compact parking space shall be removed from the proposed site plan, so the total number of compact parking spaces does not exceed 25% of the provided parking spaces on-site. 7. All bylaws, covenants, conditions and restrictions documents related to the Gallatin Valley Seed Company condominium/property owners association for the site shall be included with the final site plan submittal. The documents shall be submitted with a completed City of Bozeman “Condominium Conversion Checklist.” 8. All new signage proposed with the proposal shall be submitted in a separate City of Bozeman “Sign Permit Application,” and shall be included with the final site plan submittal.. 9. The landscape plan shall clearly show what existing landscaping is proposed to be preserved on site and what landscaping is proposed as new. 10. Permanent irrigation systems shall be provided to all landscape areas and their location(s) shall be noted on the landscape plan. 11. Two signs which read “No Parking” must be installed at the existing concrete ramp along the west elevation of Building B, in an attempt to prevent parking on the ramp. Engineering Conditions 12. The drive approach shall be constructed in accordance with the City’s standard drive approach (i.e. concrete apron, sidewalk section and drop-curb) and shown as such on the final site plan materials. Section 18.44.090.C.2.b specifies two-way commercial drive access shall be a minimum of 16 feet wide and not exceed 35 feet wide. All drive approaches shall meet all minimum separation requirements from public street intersections and other driveways. 13. The proposed project site is located in an area of known asbestos contamination in the soil. It is the responsibility of the property owner to determine the extent of any possible contamination on this site prior to construction. #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 3 291 Historic Preservation Advisory Board Conditions 14. High quality exterior and detail photos of the existing building shall be taken prior to the proposed alteration. ZONING DESIGNATION & LAND USES The property is zoned as “R-4” (Residential High Density District). The intent of the “R-4” zoning district is to provide for high-density residential development through a variety of housing types within the City with associated service functions. This will provide for a variety of compatible housing types to serve the varying needs of the community’s residents. The net density, as defined in Chapter 18.80, BMC, for new developments shall be 8 dwellings per acre or greater. Although some office use is permitted, it shall remain as a secondary use to residential development. Secondary status shall be as measured by percentage of total building area. The CUP is required because the proposal is expanding the legal, nonconforming office use on the property. Office use is a conditional use in “R-4” zoning. Please reference the following zoning map. BOZEMAN COMMUNITY PLAN DESIGNATION On June 1, 2009, the Bozeman 2020 Plan was wholly replaced by a new document entitled Bozeman Community Plan. The Future Land Use Map of this plan designates the subject property as “Community Core.” The traditional core of Bozeman is the historic downtown. This area has an extensive mutually supportive diversity of uses, a strong pedestrian and multi-modal transportation network, and a rich architectural character. Essential government services, places of public assembly, and open spaces provide the civic and social core of town. Residential development on upper floors is well established. New residential uses should be high density. The area along Main Street should be preserved as a place for high pedestrian activity uses, with strong pedestrian connectivity to other uses on nearby streets. Users are drawn from the entire planning area and beyond. The intensity of development is high with a Floor Area Ratio (FAR) well over 1. Future development should continue to be intense while providing areas of transition to adjacent areas and preserving the historic character of Main Street. The Bozeman Community Plan looks at a twenty-year horizon as well as the current situation, so it is to be expected that some areas which are not in conformance with the plan will be identified. This plan recognizes the #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 4 292 presence of these uses without specifically mapping or otherwise identifying them. It is desired that these anomalies be resolved over the term of this plan so that the land use pattern identified herein may be completed. The proposed expansion of office use and the rehabilitation of Building C on the Gallatin Valley Seed Company property are appropriate for the “Community Core” designation, as it is increasing the pedestrian activity uses on the property as well protecting the rich architectural character of the site. REVIEW CRITERIA & FINDINGS In approving the Gallatin Valley Seed Company/ Greater Yellowstone Coalition CUP/COA application with deviations, the City Commission shall consider the criteria outlined in the Unified Development Ordinance, including Section 18.28.050, “Standards for Certificates of Appropriateness,” Section 18.28.070, “Deviations from Underlying Zoning Requirements,” Section 18.34.090 “Site Plan and Master Site Plan Review Criteria,” Section 18.34.100 “City Commission Consideration and Findings for Conditional Use Permits,” and Section 18.60.020, “Changes to or Expansions of Nonconforming Uses.” The Development Review Committee (DRC), Design Review Board (DRB), Historic Preservation Advisory Board (HPAB) and Administrative Design Review (ADR) Staff evaluated the application against the applicable review criteria and offer a summary of review comments in the following sections of this report. Section 18.28.050 “Standards for Certificates of Appropriateness” The discussion below is specifically oriented toward the proposed site improvements, including the proposed rehabilitation work to Building C of the Gallatin Valley Seed Company complex. A. All work performed in completion of an approved Certificate of Appropriateness shall be in conformance with the most recent edition of the Secretary of Interior’s Standards for the Treatment of Historic Properties with Guidelines for Preserving, Rehabilitating, Restoring and Reconstructing Historic Buildings (Published 1995), published by U.S. Department of the Interior, National Park Service, Cultural Resource Stewardship and Partnerships, Heritage Preservation Services, Washington, D.C. (available for review at the Department of Planning). The Secretary of Interior’s Standards for Rehabilitation are relevant for this proposal. Building C of the Gallatin Valley Seed Company complex is listed as a non-contributing structure. Despite the structure’s status, Staff finds the proposed building rehabilitation as preservation sensitive. Significant features of the building (metal cladding and simple warehouse footprint) are being retained, while still providing new windows and entrances (light and circulation) for the new GYC office space. The existing on-site, paved parking areas have been located on the property since at least 1994 (the year of the original CUP application for the property). The proposed parking lot improvements occur to the existing surface parking areas and do not expand. Expansions would require the partial demolition or alteration to the significant structures of the historic complex (Buildings A and B). Reusing and improving the existing parking areas on site is the most appropriate rehabilitation approach. With the conditions of approval, the proposal is found to be in conformance with the Secretary of Interior Standards. B. Architectural appearance design guidelines used to consider the appropriateness and compatibility of proposed alterations with original design features of subject structures or properties, and with neighboring structures and properties, shall focus upon the following: #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 5 293 1. Height; No height change is proposed with the rehabilitation to Building C. A one-foot increase to the existing parapet was at one time considered by the representative, but is now determined as no longer necessary for the work. 2. Proportions of doors and windows; New windows are proposed on the east, south and west elevations of Building C. The proposed window locations on the east elevation overlap existing loading door locations and extend to the ground. The windows that are completely new for the east façade are distinguished from the others by not extending to the ground. The existing, small, square, mezzanine level window locations on the east elevation are preserved. Four windows of similar style to the existing mezzanine windows are proposed. The south elevation is heavily altered with a new curtain wall window system, ADA accessible ramp, window awning, and deck added to provide interior light and accommodate people accessing GYC’s office entrance. Though there are a lot of new window openings, the alterations add pedestrian interest and improve the building’s appearance for the Curtiss streetscape. The west elevation is also heavily altered with new windows. The proposed locations do not overlap existing doors, but are appropriately proportioned throughout the façade. The locations are to provide the best solar gains and air circulation. 3. Relationship of building masses and spaces; Besides the removal of the existing walkway connection between Buildings B and C, there is no proposed change to the building masses and spaces. 4. Roof shape; No change is proposed to the primary roof system of Building C. Roof mounted solar and HVAC equipment is proposed on top of the roof, but is found as appropriate. 5. Scale; The scale of Building C is retained with the rehabilitation work. This is one of the most historically appropriate approaches in the work. 6. Directional expression, with regard to the dominant horizontal or vertical expression of surrounding structures; No change is proposed with the Building C’s footprint. Therefore, the dominant horizontal length of the building is retained. 7. Architectural details; The existing corrugated metal siding will be preserved in the rehabilitation work. Other architectural details include grass roof awnings with timber bracing, decks, windows, wood mechanical screening, and black pipe and timber rails for the ADA accessible ramp. All details are found to be appropriate for the building character. 8. Concealment of nonperiod appurtenances, such as mechanical equipment; and #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 6 294 Roof mounted equipment other than the solar and HVAC equipment requires screening as described in Section 18.38.050.F of the Unified Development Ordinance. 9. Materials and color schemes (any requirements or conditions imposed regarding color schemes shall be limited to the prevention of nuisances upon abutting properties and prevention of degradation of features on the property in question. Color schemes may be considered as primary design elements if a deviation from the underlying zoning is requested). See comments under “Architectural Details.” C. Contemporary, nonperiod and innovative design of new structures and additions to existing structures shall be encouraged when such new construction or additions do not destroy significant historical, cultural or architectural structures, or their components, and when such design is compatible with the foregoing elements of the structure and the surrounding structures. Not applicable because no new structures or additions are proposed. D. When applying the standards of subsections A-C, the review authority shall be guided by the Design Guidelines for the Neighborhood Conservation Overlay District which are hereby incorporated by this reference. When reviewing a contemporary, non-period, or innovative design of new structures, or addition to existing structure, the review authority shall be guided by the Design Guidelines for the Neighborhood Conservation Overlay District to determine whether the proposal is compatible with any existing or surrounding structures. Staff considered the applicable chapters of the Design Guidelines for Historic Preservation & the Neighborhood Conservation Overlay District while making comments for the architectural appearance design guidelines. E. Conformance with other applicable development standards of this title. Based on the requirements outlined in Chapters 18.28, 18.34 and 18.60 of the Bozeman Unified Development Ordinance, Planning Staff has provided comments in this report to comply with the “Deviations from Underlying Zoning Requirements,” “Site Plan and Master Site Plan Review Criteria,” “City Commission Consideration and Findings for Conditional Use Permits,” and “Conformance to or Expansion of Nonconforming Uses” sections. Section 18.28.070 “Deviations from Underlying Zoning Requirements” Two deviation requests from the Unified Development Ordinance are included in the CUP/COA application. Both are examined under the criteria listed below. A. Modifications shall be historically appropriate for the building and site in question and the adjacent properties; Section 18.38.060, “Yard and Height Encroachments, Limitations, and Exceptions” Staff finds it historically appropriate to add window awnings and decks to Building C. Both additions will improve the streetscape along Curtiss Street and add opportunities for pedestrian activity. The predominate portion of the deck is located within the allowable yard encroachment areas. Because of the significantly small area of encroachment (42 square feet), Staff finds it historically appropriate for the building and site. #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 7 295 Section 18.46.040, “Number of Parking Spaces Required” The parking deviation allows for the continued reuse and rehabilitation of the historic buildings. The reduction of on-site surface parking allows the improved parking area to occur in the existing surface parking areas, rather than expand and remove character-defining features of the property (Buildings A and B). Staff finds a reduction in required parking spaces as historically appropriate for the building and site. B. Modifications will have minimal adverse effect on abutting properties or the permitted uses thereof; Section 18.38.060, “Yard and Height Encroachments, Limitations, and Exceptions” Staff doesn’t find any adverse effect on abutting properties from the requested covered deck encroachment in the required front yard along Curtiss Street. Ten feet of yard is still provided along Curtiss Street. The encroachment doesn’t block any on-street parking. Section 18.46.040, “Number of Parking Spaces Required” In the 1994 CUP application for the Gallatin Valley Seed Company property, it was determined that the proposed mix of uses in the three buildings created a demand of 55 parking spaces. Staff is assuming the uses in Buildings A and B have not significantly changed since 1994 (based on discussions with the property owner and representative). This means the current parking demand is the same as in 1994, which is 55 spaces. An increase of 10 parking spaces occurs with the proposed change from warehouse to office use in Building C. This brings the parking demand to 65 spaces. After the proposed site improvements, 54 parking spaces are located in the on-site parking areas. This creates a parking deviation of 11 spaces. On-street parking adjacent to property may not be counted toward office use per the Unified Development Ordinance. If on-street parking was included in the parking supply, an increase of 13 spaces occurs. Staff visited the site several times throughout the application review process. It appeared that ample parking existed on the site. The parking areas that seemed the most popular with the buildings’ occupants were the primary lot along Wallace Avenue and the small lot to the west of Building A. TV station vehicles seemed to accommodate most of the small parking lot west of Building A. During all site visits, the entire stretch of alley parking was predominately empty. On-street parking appeared adequately used on the adjacent streets (Olive and Curtiss Streets and Wallace Avenue). Staff finds the deviation request for a reduction of 11 required parking spaces as appropriate for the site. Staff finds the deviation as having a minimal adverse effect on the abutting properties. C. Modifications shall assure the protection of the public health, safety and general welfare. Section 18.38.060, “Yard and Height Encroachments, Limitations, and Exceptions” The covered deck encroachment does not impede the protection of the public health, safety and general welfare. Section 18.46.040, “Number of Parking Spaces Required” During the Development Review Committee (DRC) review of the project, both the Fire and Building Departments checked the proposal to assure the protection of public health, safety and general welfare. There is adequate fire truck access to the site. Staff is including a condition of approval that requires the #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 8 296 placement of two “No Parking,” signs at the concrete ramp located on the west elevation of Building B to help restrict cars parking on that angled, paved area. Section 18.34.090 “Site Plan and Master Site Plan Review Criteria” In considering applications for site plan approval under this title, the City Commission shall consider the following: 1. Conformance to and consistency with the City’s adopted growth policy. Staff finds the proposed office expansion in Building C as appropriate for the “Community Core” designated land. 2. Conformance to this title, including the cessation of any current violations. The property owner must comply with all provisions of the Bozeman Municipal Code, which are applicable to this project prior to receiving final site plan approval. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. The following code provisions must be addressed with the final site plan submittal. Planning Code Provisions • Section 18.34.100, “Board of Adjustment Consideration and Findings for Conditional Use Permits,” the right to a use and occupancy permit shall be contingent upon the fulfillment of all general and special conditions imposed by the conditional use permit procedure. • Section 18.34.100, all of the special conditions shall constitute restrictions running with the land use, shall apply and be adhered to by the owner of the land, successors or assigns, shall be binding upon the owner of the land, his successors or assigns, shall be consented to in writing, and shall be recorded as such with the County Clerk and Recorder’s Office by the property owner prior to the issuance of any building permits, final site plan approval or commencement of the conditional use. • Section 18.34.130, “Final Site Plan,” no later than six months after the date of approval of a preliminary site plan or master site plan, the applicant shall submit to the Department of Planning seven (7) copies of final site plan materials. The final site plan shall contain all of the conditions, corrections and modifications approved by the Department of Planning. • Section 18.34.130, a Building Permit must be obtained prior to the work, and must be obtained within one year of final site plan approval. Building Permits will not be issued until the final site plan is approved. Minor site surface preparation and normal maintenance shall be allowed prior to submittal and approval of the final site plan, including excavation and footing preparation, but NO CONCRETE MAY BE POURED UNTIL A BUILDING PERMIT IS OBTAINED. • Section 18.34.130, upon submitting the final site plan for approval by the Planning Director, and prior to the issuance of a building permit, applicant shall also submit a written narrative outlining how each of the above conditions of approval and code provisions have been satisfied or met. • Section 18.38.050.F, “Accessory Buildings, Uses and Equipment,” all mechanical equipment shall be screened. Rooftop equipment should be incorporated into the roof form and ground mounted equipment shall be screened with walls, fencing or plant materials. • Section 18.42.080.H, “Grading and Drainage,” stormwater retention/detention facilities in #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 9 297 landscaped areas shall be designed as landscape amenities. They shall be an organic feature with a natural, curvilinear shape. The facilities shall have 75 percent of surface area covered with live vegetation appropriate for the depth and design of the retention/detention facility, and be lined with native grasses, indigenous plants, wet root tolerant plant types and groupings of boulders to create a functional yet, natural site feature. A cross section and landscape detail of each facility shall be submitted with the final landscape plan for review and approval. • Section 18.42.150, “Lighting,” all proposed site and building lighting shall comply with said section requirements. A detailed lighting plan shall be included with the final site plan submittal. • Section 18.42.170, “Trash and Garbage Enclosures,” a permanent enclosure for temporary storage of garbage, refuse, and other solid waste shall be provided for every use, other than single-household dwellings, duplexes, individually owned townhouse or condominium units, unless other arrangements are made. A narrative detail as to the garbage receptacle arrangements shall be provided with the final site plan submittal. • Section 18.42.170, the size of the trash receptacle shall be appropriately sized for the use and approved by the City Sanitation Department. Accommodations for recyclables must also be considered. All receptacles shall be located inside of an approved trash enclosure. A copy of the site plan, indicating the location of the trash enclosure, dimensions of the receptacle and enclosure and details of the materials used, shall be sent to and approved by the City Sanitation Division (phone: 586-3258) prior to final site plan approval. • Section 18.44.100, “Street Vision Triangle,” at the intersection of each driveway or alley with a street, no fence, wall or planting > 30” above the street centerline grades, shall be permitted in the street vision triangle. • Chapter 18.46, “Parking,” all proposed parking affiliated with the project, both on- and off-site, shall comply with said chapter requirements. • Section 18.48.050, “Mandatory Landscaping Provisions,” all proposed landscaping shall comply with said section requirements. Parking lot landscaping shall apply to the area within the perimeter of the paved portion of the parking areas. • Section 18.48.060, “Landscape Performance Standards,” all proposed landscaping shall comply with said section requirements. The lot has residential adjacency, so 23 points are required for the required landscaping standards. • Section 18.52.060, “Signs Permitted Upon the Issuance of a Sign Permit,” any signage associate with the development must obtain a sign permit, as well as, meet the requirements of this section. • Section 18.64.100, “Building Permit Requirements,” a Building Permit must be obtained prior to the work, and must be obtained within one year of final site plan approval. Building Permits will not be issued until the final site plan is approved. • Section 18.64.110, “Permit Issuance,” states that no permit or license shall be issued unless the use, arrangement and construction has been set forth in such approved plans and applications. • Section 18.78.100, “Submittal Requirements for Landscape Plans,” the landscape plan shall abide by all the submittal requirements listed in this section. #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 10298 Engineering Code Provisions a. The final site plan shall be adequately dimensioned. A complete legend of all line types used shall also be provided. b. A Storm Water Drainage/Treatment Grading Plan and Maintenance Plan for a system designed to remove solids, silt, oils, grease, and other pollutants must be provided to and approved by the City Engineer. The plan must demonstrate adequate site drainage (including sufficient spot elevations), storm water detention/retention basin details (including basin sizing and discharge calculations, and discharge structure details), storm water discharge destination, and a storm water maintenance plan. c. Sewer and water services shall be shown on the final site plan and approved by the Water/Sewer Superintendent. City of Bozeman applications for service shall be completed by the applicant. d. The drive approach shall be constructed in accordance with the City's standard approach (i.e., concrete apron, sidewalk section and drop-curb) and shown as such on the final site plan. e. All existing utility and other easements must be shown on the final site plan. f. Typical curb details (i.e., raised and/or drop curbs) and typical asphalt paving section detail shall be provided to and approved by the City Engineer. Concrete curbing shall be provided around the entire new parking lot perimeter and adequately identified on the final site plan. g. Adequate snow storage area must be designated outside the sight triangles, but on the subject property (unless a snow storage easement is obtained for a location off the property and filed with the County Clerk and Recorder's office). h. Necessary backflow prevention must be demonstrated for all proposed water service lines. i. Drive approach and public street intersection sight triangles shall be free of plantings which at mature growth will obscure vision within the sight triangle. j. All trees must be at least 10 feet from any public utilities or service lines. All public utilities and services lines must be shown on the Final Landscaping plan. k. The applicant shall submit a construction route map dictating how materials and heavy equipment will travel to and from the site in accordance with section 18.74.020.A.1 of the Unified Development Ordinance. This shall be submitted as part of the final site plan for site developments, or with the infrastructure plans for subdivisions. It shall be the responsibility of the applicant to ensure that the construction traffic follows the approved routes. l. All construction activities shall comply with section 18.74.020.A.2 of the Unified Development Ordinance. This shall include routine cleaning/sweeping of material that is dragged to adjacent streets. The City may require a guarantee as allowed for under this section at any time during the construction to ensure any damages or cleaning that are required are complete. The developer shall be responsible to reimburse the City for all costs associated with the work if it becomes necessary for the City to correct any problems that are identified. 3. Conformance with all other applicable laws, ordinances, and regulations. The proposal conforms to all other applicable laws, ordinances, and regulations. All conditions for a CUP must be met prior to final site plan approval, including the recording of the conditions for the Conditional Use Permit. Following final site plan approval, the proposal will be held to all provisions of the International Building Code (IBC) during the building permit review. #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 11299 4. Relationship of site plan elements to conditions both on and off the property. With the recommended conditions of approval, the proposal is found to be compatible with and sensitive to the immediate environment of the site and adjacent neighborhood. The significant historic character of the site is preserved with the proposal. 5. The impact of the proposal on the existing and anticipated traffic and parking conditions. In the 1994 CUP application for the Gallatin Valley Seed Company property, it was determined that the proposed mix of uses in the three buildings created a demand of 55 parking spaces. Staff is assuming the uses in Buildings A and B have not significantly changed since 1994 (based on discussions with the property owner and representative). This means the current parking demand is the same as in 1994, which is 55 spaces. An increase of 10 parking spaces occurs with the proposed change from warehouse to office use in Building C. This brings the parking demand to 65 spaces. After the proposed site improvements, 54 parking spaces are located in the on-site parking areas. This creates a parking deviation of 11 spaces. On-street parking adjacent to property may not be counted toward office use per the Unified Development Ordinance. If on-street parking was included in the parking supply, an increase of 13 spaces occurs. Staff visited the site several times throughout the application review process. It appeared that ample parking existed on the site. The parking areas that seemed the most popular with the buildings’ occupants were the primary lot along Wallace Avenue and the small lot to the west of Building A. TV station vehicles seemed to accommodate most of the small parking lot west of Building A. During all site visits, the entire stretch of alley parking was predominately empty. On-street parking appeared adequately used on the adjacent streets (Olive and Curtiss Streets and Wallace Avenue). Staff finds the deviation request for a reduction of 11 required parking spaces as having a minimal adverse effect on the anticipated traffic and parking conditions. 6. Pedestrian and vehicular ingress and egress. The proposal show adequate design of pedestrian and vehicular circulation systems so that pedestrians and vehicles can move safely and easily within the site. A pedestrian pathway is added between Buildings B and C after the walkway connection is removed. New sidewalks are added off the Curtiss Street sidewalk to provide pedestrian access to the GYC entrance. 7. Landscaping, including the enhancement of buildings, the appearance of vehicular use, open space, and pedestrian areas, and the preservation or replacement of natural vegetation. The proposal includes plantings in the internal parking islands to enhance the parking areas. Long stretches of landscaping is added along the west and south elevations of Building C. Grass covered awnings are added to all elevations of Building C to enhance the building exterior. A deck and landscaping is added to the south elevation of Building C to enhance the pedestrian entrance. As required by the Unified Development Ordinance, a separate landscape plan shall be submitted with the final site plan submittal. The property has residential adjacency and requires 23 performance points. 8. Open space. No additional square footage of open space or park land is required as the proposal does not include residential units. #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 12300 9. Building location and height. No change is occurring to Building C’s location or height. The existing footprint is also unchanged. 10. Setbacks. The property has a required 15-foot front yard setback along its entire perimeter. The parking areas received a deviation to be permitted in the front yard with the 1994 CUP application. One of the deviations with the proposal is for a small (42 square foot area) covered deck encroachment into the required 15-foot yard setback along Curtiss Street. 11. Lighting. All future lighting must meet provisions of Section 18.42.150 in the Unified Development Ordinance, which includes the requirement to have all lighting turned off between 11:00 p.m. and 6:00 a.m. and the requirement to have all lighting fixtures shielded in a manner that no light is emitted above a horizontal plane passing through the lowest point of the light emitting element (or in other words, only lighting directed downward is permitted). 12. Provisions for utilities, including efficient public services and facilities. As required by Engineering Staff, sewer and water services shall be shown on the final site plan and approved by the Water/Sewer Superintendent. City of Bozeman applications for service shall be completed by the applicant. Necessary backflow prevention must be demonstrated for the existing water service line. Also, all existing utility and other easements must be shown on the final site plan. 13. Site surface drainage. As required by Engineering Staff, a Storm Water Drainage/Treatment Grading Plan and Maintenance Plan for a system designed to remove solids, silt, oils, grease, and other pollutants must be provided to and approved by the City Engineer. The plan must demonstrate adequate site drainage (including sufficient spot elevations), storm water detention/retention basin details (including basin sizing and discharge calculations, and discharge structure details), storm water discharge destination, and a storm water maintenance plan. 14. Loading and unloading areas. The existing parking areas accommodate the building’s loading and unloading areas for the building’s occupants and visitors. The new drive approach from Curtiss Street will be designed to City standards for commercial access. All remaining drive approaches remain in their existing locations. 15. Grading. The parking areas retain their existing asphalt paving. Planning staff is requiring any holes in the pavement to be repaired. As required by Engineering Staff, a Storm Water Drainage/Treatment Grading Plan and Maintenance Plan for a system designed to remove solids, silt, oils, grease, and other pollutants must be provided to and approved by the City Engineer. 16. Signage; Any signage associated with the development must obtain a sign permit, as well as, meet the requirements of Chapter 18.52, “Signs,” of the Unified Development Ordinance. #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 13301 17. Screening. The parking areas received a deviation with the 1994 CUP application to reduce landscaping requirements and not provide landscape screening from public right-of-ways (space doesn’t permit landscape screening). All future mechanical equipment must be adequately screened as noted in the Unified Development Ordinance. 18. Overlay district provisions. The property is located within the Neighborhood Conservation Overlay District and was reviewed under the “Standards for Certificates of Appropriateness,” as included in Section 18.28.050 of the Unified Development Ordinance. 19. Other related matters, including relevant comment from affected parties. The application was publicly noticed with a notice posted on-site and a notice published for two Sundays in the Bozeman Daily Chronicle. The notice was also sent to neighbors within 200 feet of the subject property. The Department of Planning & Community Development received one email of public comment on the project. The email was forwarded from the City’s Neighborhoods Coordinator. The email’s author expressed overall support of GYC moving into Building C, but expressed concern about the lack of on- street parking in front of his property located on Olive Street. He stated the TV station office located in Building A creates the on-street parking congestion. Staff did not notice on-street parking congestion along Olive Street when visiting the site. Staff informed the email author that on-street parking is typically available on a “first come, first serve” basis. Staff also suggested contacting the TV station directly about their company vehicle parking habits. 20. If the development includes multiple lots that are interdependent for circulation or other means of addressing requirement of this title, whether the lots are either: a. Configured so that the sale of individual lots will not alter the approved configuration or use of the property or cause the development to become nonconforming; b. The subject of reciprocal and perpetual easements or other agreements to which the City is a party so that the sale of individual lots will not cause one or more elements of the development to become nonconforming. Not applicable. 21. Compliance with Title 17 Chapter, B.M.C. Not applicable. Section 18.34.100 “Board of Adjustment Consideration and Record for Conditional Use Permits” The standard review authority for CUP/COA applications with deviations is the Board of Adjustment (BOA). However, the project is dealing with the expansion of a lawful nonconforming nonresidential use (office). This type of expansions may be expanded only through the granting of a CUP by the City Commission. . #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 14302 In addition to the review criteria outlined above, the City Commission shall, in approving a CUP, find favorably as follows: 1. That the site for the proposed use is adequate in size and topography to accommodate such use, and all yards, spaces, walls and fences, parking, loading and landscaping are adequate to properly relate such use with the land and uses in the vicinity. The 1994 CUP application approved a mix of uses on the historic Gallatin Valley Seed Company property. The application included several deviations to allow parking areas to encroach into required front yard setbacks, to allow parking spaces to back into the alley public right-of-way, and to allow a reduction in landscaping requirements. Since 1994, the historic property has adequately handled the mix of uses. Staff finds the property as adequate is size to accommodate additional office use. Improvements to the parking areas (new striping, landscaped islands, etc) will better accommodate cars. On-street parking is available around the property to accommodate any shortage of parking on-site. 2. That the proposed use will have no material adverse effect upon the abutting property. Persons objecting to the recommendations of review bodies carry the burden of proof. Staff visited the site several times throughout the application review process. It appeared that ample parking existed on the site. Staff finds the office expansion, and the deviation request for a reduction of 11 required parking spaces, as appropriate for the site. Staff finds the expansion and deviation as having minimal material adverse effects on the abutting properties. 3. That any additional conditions stated in the approval are deemed necessary to protect the public health, safety and general welfare. Such conditions may include, but are not limited to: regulation of use; special yards, spaces, and buffers; special fences, solid fences and walls; surfacing of parking areas; requiring street, service road or alley dedications and improvements or appropriate bonds; regulation of points of vehicular ingress and egress; regulation of signs; requiring maintenance of the grounds; regulation of noise, vibrations and odors; regulation of hours for certain activities; time period within which the proposed use shall be developed; duration of use; requiring the dedication of access rights; other such conditions as will make possible the development of the City in an orderly and efficient manner. Several of the conditions of approval listed in this report address the issues listed above and are recommended by the Development Review Committee (DRC), and Planning and Engineering Staff, to the City Commission for their final action 18.60.020 “Changes to or Expansions of Nonconforming Uses” A lawful nonconforming nonresidential use may be expanded only through the granting of a CUP by the City Commission. In considering the appropriateness of the CUP application, the City Commission shall weigh the criteria set forth below. In addition, the Commission shall consider whether the expansion is reasonable, natural and incidental to the growth and use of an existing business. To approve a CUP to change or expand a nonconforming nonresidential use, the City Commission shall determine that the proposed nonconforming use is more appropriate to the district than the existing nonconforming use, and that no unsafe or unhealthy conditions are perpetuated. In making such a determination, the Commission shall weigh the following criteria in addition to the criteria applicable to all conditional use permits: #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 15303 a. Traffic impacts, both onsite and offsite; The new drive approach from the front parking area to Curtiss Street will better accommodate automobile traffic throughout the parking areas. If the building’s occupants or visitors use the available on-street parking, the parked cars will likely slow down traffic speeds on streets. b. Off-street parking and loading requirements; Staff visited the site several times throughout the application review process. It appeared that ample parking existed on the site. Staff finds the office expansion, and the deviation request for a reduction of 11 required parking spaces, as appropriate for the site. c. The visual impact on the surrounding area; The proposed rehabilitation to Building C and the large amounts of landscaping added to the site will both drastically improve the visual impact of the property, which has deteriorated over the years. d. The degree of compliance with the adopted growth policy and this title; The proposed expansion of office use and the rehabilitation of Building C on the Gallatin Valley Seed Company property are appropriate for the “Community Core” designation, as it is increasing the pedestrian activity uses on the property as well protecting the rich architectural character of the site. e. The level of conflict with other uses in the surrounding area; Staff does not anticipate a level of conflict with other uses in the surrounding area because of the property’s close proximity to “B-3” commercial zoning. f. The presence of other nonconformities in the surrounding area; No nonconformities identified. g. The degree to which any existing unsafe or hazardous conditions would be mitigated; No unsafe or hazardous conditions identified. h. The viability of the subject structure(s); and The rectangular building footprint and open interior floor plan of Building C will easily accommodate an office use. i. Onsite and offsite impacts from noise, dust, smoke, surface or groundwater contamination, or other environmental impacts. The recommended Engineering conditions of approval address the issues of possible asbestos contamination on the property. CONCLUSION The standard review authority for CUP/COA with a deviation applications, is the Board of Adjustment (BOA). However, this CUP is dealing specifically with the expansion of a lawful nonconforming nonresidential use (office). Per Section 18.60.020, “Changes To or Expansions of Nonconforming Uses,” of the Unified Development Ordinance, this type of nonconforming expansion must be approved through the granting of a CUP by the City Commission (per Section). Therefore, the City Commission is the final review authority. #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 16304 #Z-09092 Gallatin Valley Seed Company/ Greater Yellowstone Coalition Staff Report 17 Based on the analysis contained within this report, Planning Staff and the Development Review Committee find the CUP application, with conditions, is in general compliance with the City of Bozeman Unified Development Ordinance. Planning Staff has identified various code provisions which must be met by this application. Some or all of these items are listed in the findings of this report. The applicant must comply with all provisions of the Bozeman Municipal Code, which are applicable to this project prior to receiving final site plan approval. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. THE BOZEMAN CITY COMMISSION SHALL MAKE THE FINAL DECISION ON THIS APPLICATION FOR A CONDITIONAL USE PERMIT AND CERTIFICATE OF APPROPRIATENESS. ANY AGGRIEVED PERSON AS SET FORTH IN CHAPTER 18.66 OF THE BOZEMAN MUNICIPAL CODE MAY APPEAL THE DECISION OF THE CITY COMMISSION. Attachments: Applicant’s Submittal Materials DRB Staff memo (same sent to HPAB) HPAB minutes (draft) Report Sent To: Gallatin Valley Seed Company, Inc., 201 S. Wallace Avenue, Bozeman, MT 59715 Greater Yellowstone Coalition, PO Box 1874, Bozeman, MT 59771 CTA Architects Engineers, Inc., 1143 Stoneridge Drive, Bozeman, MT 59718 305 306 307 Page 3 (Site Plan Checklist – Prepared 12/05/03; revised 9/22/04) SITE PLAN CHECKLIST These checklists shall be completed and returned as part of the submittal. Any item checked “No” or “N/A” (not applicable) must be explained in a narrative attached to the checklist. Incomplete submittals will be returned to the applicant. A. Design Review Board (DRB) Site Plan Review Thresholds. Does the proposal include one or more of the following: Design Review Board (DRB) Site Plan Review Thresholds Yes No 1. 20 or more dwelling units in a multiple household structure or structures 2. 30,000 or more square feet of office space, retail commercial space, service commercial space or industrial space 3. More than two buildings on one site for permitted office uses, permitted retail commercial uses, permitted service commercial uses, permitted industrial uses or permitted combinations of uses 4. 20,000 or more square feet of exterior storage of materials or goods 5. Parking for more than 60 vehicles B. General Information. The following information shall be provided for site plan review: General Information Yes No N/A 1. Location map, including area within one-half mile of the site 2. List of names and addresses of property owners according to Chapter 18.76, BMC (Noticing) 3. A construction route map shall be provided showing how materials and heavy equipment will travel to and from the site. The route shall avoid, where possible, local or minor collector streets or streets where construction traffic would disrupt neighborhood residential character or pose a threat to public health and safety 4. Boundary line of property with dimensions 5. Date of plan preparation and changes 6. North point indicator 7. Suggested scale of 1 inch to 20 feet, but not less than 1 inch to 100 feet 8. Parcel size(s) in gross acres and square feet 9. Estimated total floor area and estimated ratio of floor area to lot size (floor area ratio, FAR), with a breakdown by land use 10. Location, percentage of parcel(s) and total site, and square footage for the following: a. Existing and proposed buildings and structures b. Driveway and parking c. Open space and/or landscaped area, recreational use areas, public and semipublic land, parks, school sites, etc. d. Public street right-of-way 11. Total number, type and density per type of dwelling units, and total net and gross residential density and density per residential parcel 12. Detailed plan of all parking facilities, including circulation aisles, access drives, bicycle racks, compact spaces, handicapped spaces and motorcycle parking, on-street parking, number of employee and non-employee parking spaces, existing and proposed, and total square footage of each 308 Page 4 General Information, continued Yes No N/A 13. The information required by Section 18.78.060.L, BMC (Streets, Roads and Alleys), unless such information was previously provided through a subdivision review process, or the provision of such information was waived in writing by the City during subdivision review of the land to be developed, or the provision of such information is waived in writing by the City prior to submittal of a preliminary site plan application 14. Description and mapping of soils existing on the site, accompanied by analysis as to the suitability of such soils for the intended construction and proposed landscaping 15. Building design information (on-site): a. Building heights and elevations of all exterior walls of the building(s) or structure(s) b. Height above mean sea level of the elevation of the lowest floor and location of lot outfall when the structure is proposed to be located in a floodway or floodplain area c. Floor plans depicting location and dimensions of all proposed uses and activities 16. Temporary facilities plan showing the location of all temporary model homes, sales offices and/or construction facilities, including temporary signs and parking facilities 17. Unless already provided through a previous subdivision review, a noxious weed control plan complying with Section 18.78.050.H, BMC (Noxious Weed Management and Revegetation Plan) 18. Drafts of applicable supplementary documents as set forth in Chapter 18.72, BMC (Supplementary Documents) C. Site Plan Information. The location, identification and dimension of the following existing and proposed data, onsite and to a distance of 100 feet (200 feet for PUDs) outside the site plan boundary, exclusive of public rights-of-way, unless otherwise stated: Site Plan Information Yes No N/A 1. Topographic contours at a minimum interval of 2 feet, or as determined by the Planning Director 2. Adjacent streets and street rights-of-way to a distance of 150 feet, except for sites adjacent to major arterial streets where the distances shall be 200 feet 3. On-site streets and rights-of-way 4. Ingress and egress points 5. Traffic flow on-site 6. Traffic flow off-site 7. Utilities and utility rights-of-way or easements: a. Electric b. Natural gas c. Telephone, cable television and similar utilities d. Water e. Sewer (sanitary, treated effluent and storm) 8. Surface water, including: a. Holding ponds, streams and irrigation ditches b. Watercourses, water bodies and wetlands c. Floodplains as designated on the Federal Insurance Rate Map or that may otherwise be identified as lying within a 100-year floodplain through additional floodplain delineation, engineering analysis, topographic survey or other objective and factual basis d. A floodplain analysis report in compliance with Chapter 18.58, BMC (Bozeman Floodplain Regulations) if not previously provided with subdivision review 309 Page 5 Site Plan Information, continued Yes No N/A 9. Grading and drainage plan, including provisions for on-site retention/detention and water quality improvement facilities as required by the Engineering Department, or in compliance with any adopted storm drainage ordinance or best management practices manual adopted by the City 10. All drainageways, streets, arroyos, dry gullies, diversion ditches, spillways, reservoirs, etc. which may be incorporated into the storm drainage system for the property shall be designated: a. The name of the drainageway (where appropriate) b. The downstream conditions (developed, available drainageways, etc.) c. Any downstream restrictions 11. Significant rock outcroppings, slopes of greater than 15 percent or other significant topographic features 12. Sidewalks, walkways, driveways, loading areas and docks, bikeways, including typical details and interrelationships with vehicular circulation system, indicating proposed treatment of points of conflict 13. Provision for handicapped accessibility, including but not limited to, wheelchair ramps, parking spaces, handrails and curb cuts, including construction details and the applicant’s certification of ADA compliance 14. Fences and walls, including typical details 15. Exterior signs. Note – The review of signs in conjunction with this application is only review for compliance with Chapter 18.52, BMC (Signs). A sign permit must be obtained from the Department of Planning and Community Development prior to erection of any and all signs. 16. Exterior refuse collection areas, including typical details 17. A site plan, complete with all structures, parking spaces, building entrances, traffic areas (both vehicular and pedestrian), vegetation that might interfere with lighting, and adjacent uses, containing a layout of all proposed fixtures by location and type. The materials required in Section 18.78.060.R, BMC (Lighting Plan), if not previously provided 18. Curb, asphalt section and drive approach construction details 19. Landscaping - detailed plan showing plantings, equipment, and other appropriate information as required in Section 18.78.100, BMC (Submittal Requirements for Landscaping Plans). If required, complete section C below 20. Unique natural features, significant wildlife areas and vegetative cover, including existing trees and shrubs having a diameter greater than 2.5 inches, by species 21. Snow storage areas 22. Location of City limit boundaries, and boundaries of Gallatin County’s Bozeman Area Zoning Jurisdiction, within or near the development 23. Existing zoning within 200 feet of the site 24. Historic, cultural and archeological resources, describe and map any designated historic structures or districts, and archeological or cultural sites 25. Major public facilities, including schools, parks, trails, etc. 26. The information necessary to complete the determination of density change and parkland provision required by Chapter 18.50, BMC, unless such information was previously determined by the City to be inapplicable and written confirmation is provided to the applicant prior to submittal of a preliminary site plan application. If a new park will be created by the development, the park plan materials of Section 18.78.060.P, BMC shall be provided. 27. Describe how the site plan will satisfy any requirements of Section 17.02, BMC (Affordable Housing) which have either been established for that lot(s) through the subdivision process or if no subdivision has previously occurred are applicable to a site plan. The description shall be of adequate detail to clearly identify those lots and dwellings designated as subject to Title 17, Chapter 2, BMC compliance requirements and to make the obligations placed on the affected lots and dwellings readily understandable. 310 Page 6 D. Landscape Plans. If a landscape plan is required, the following information shall be provided on the landscape plan: Landscape Plan Information Yes No N/A 1. Date, scale, north arrow, and the names, addresses, and telephone numbers of both the property owner and the person preparing the plan 2. Location of existing boundary lines and dimensions of the lot 3. Approximate centerlines of existing watercourses, required watercourse setbacks, and the location of any 100-year floodplain; the approximate location of significant drainage features; and the location and size of existing and proposed streets and alleys, utility easements, utility lines, driveways and sidewalks on the lot and/or adjacent to the lot 4. Project name, street address, and lot and block description 5. Location, height and material of proposed screening and fencing (with berms to be delineated by one foot contours) 6. Locations and dimensions of proposed landscape buffer strips, including watercourse buffer strips 7. Complete landscape legend providing a description of plant materials shown on the plan, including typical symbols, names (common and botanical name), locations, quantities, container or caliper sizes at installation, heights, spread and spacing. The location and type of all existing trees on the lot over 6 inches in caliper must be specifically indicated 8. Complete illustration of landscaping and screening to be provided in or near off-street parking and loading areas, including information as to the amount (in square feet) of landscape area to be provided internal to parking areas and the number and location of required off-street parking and loading spaces 9. An indication of how existing healthy trees (if any) are to be retained and protected from damage during construction 10. Size, height, location and material of proposed seating, lighting, planters, sculptures, and water features 11. A description of proposed watering methods 12. Location of street vision triangles on the lot (if applicable) 13. Tabulation of points earned by the plan – see Section 18.48.060, BMC (Landscape Performance Standards) 14. Designated snow removal storage areas 15. Location of pavement, curbs, sidewalks and gutters 16. Show location of existing and/or proposed drainage facilities which are to be used for drainage control 17. Existing and proposed grade 18. Size of plantings at the time of installation and at maturity 19. Areas to be irrigated 20. Planting plan for watercourse buffers, per Section 18.42.100, BMC (Watercourse Setbacks), if not previously provided through subdivision review 21. Front and side elevations of buildings, fences and walls with height dimensions if not otherwise provided by the application. Show open stairways and other projections from exterior building walls 311 Page 3 (Certificate of Appropriateness Checklist 2 – Prepared 11/25/03; revised on 9/8/04) CERTIFICATE OF APPROPRIATNESS CHECKLIST 2 If a project is located in the Neighborhood Conservation Overlay District or the Entryway Corridor Overlay District, and DOES NOT qualify for review as a Sketch Plan; Reuse, Change of Use or Further Development of a Site Developed Before 9-3-91; or Amendment/Modification of a Plan Approved On or After 9-3-91, this checklist shall be used. See Section 18.34.050 (Sketch Plan Review), Section 18.34.150 (Amendments to Sketch and Site Plans) or Section 18.34.170 (Reuse, Change in Use or Further Development of Sites Developed Prior to the Adoption of the Ordinance Codified in This Title), BMC. These checklists shall be completed and returned as part of the submittal. Any item checked “No” or “N/A” (not applicable) must be explained in a narrative attached to the checklist. Incomplete submittals will be returned to the applicant. A. Neighborhood Conservation Overlay District. If a proposed development is located in the Neighborhood Conservation Overlay District, information shall be provided to the appropriate review authority to review prior to granting or denying a certificate of appropriateness. The extent of documentation to be submitted on any project shall be dictated by the scope of the planned alteration and the information reasonably necessary for the appropriate review authority to make its determination. At a minimum, the following items shall be included in the submission: Neighborhood Conservation Overlay District Information Yes No N/A 1. One current picture of each elevation of each structure planned to be altered and such additional pictures of the specific elements of the structure or property to be altered that will clearly express the nature and extent of change planned. Except when otherwise recommended, no more than eight pictures should be submitted and all pictures shall be mounted on letter-size sheets and clearly annotated with the property address, elevation direction (N, S, E, W) and relevant information 2. Historical information, including available data such as pictures, plans, authenticated verbal records and similar research documentation that may be relevant to the planned alteration 3. Materials and color schemes to be used 4. Plans, sketches, pictures, specifications and other data that will clearly express the applicant’s proposed alterations 5. A schedule of planned actions that will lead to the completed alterations 6. Such other information as may be suggested by the Planning Department 7. Description of any applicant-requested deviation(s) and a narrative explanation as to how the requested deviation(s) will encourage restoration and rehabilitation activity that will contribute to the overall historic character of the community B. Entryway Corridor Overlay District. If a proposed development is located in the Entryway Corridor Overlay District, information shall be provided to the appropriate review authority to review prior to granting or denying a certificate of appropriateness. The extent of documentation to be submitted on any project shall be dictated by the scope of the planned alteration and the information reasonably necessary for the appropriate review authority to make its determination. At a minimum, the following items shall be included in the submission: Entryway Corridor Overlay District Information Yes No N/A 1. Plans, sketches, pictures, specifications and other data that will clearly express the applicant’s proposed alterations 2. Such other information as may be suggested by the Planning Department 3. If the proposal includes an application for a deviation as outlined in Section 18.66.050 (Deviations), BMC, the application for deviation shall be accompanied by written and graphic material sufficient to illustrate the conditions that the modified standards will produce, so as to enable the City Commission to make the determination that the deviation will produce an environment, landscape quality and character superior to that produced by the existing standards, and will be consistent with the intent and purpose of Chapter 18.30 (Entryway Corridor Overlay District), BMC. 312 313 314 !"#"$$% &’! !"#$ %&"’ ($ )&*+ "’, -. ,&*+ /#0" 1)" 2 3 ")&4 ""5 ($ 3 "" ($ $ 66 "5 ($ 7 ’ (’5#$ % 4 "8 ($ /1&8#064 $4%85)4 ’9 .". 6’3 "" ($ 4&/#0"" !: (;&"(&(< =+$%%"’ ($(<"*(<5 3>4+ /#085"1&: 315 ! " #!$%&’&% &(%(& %)(&(%(%" %*+ & ,% ,% % )%-, (% . /,(## 0 1 ,( *2 &## 3 ,(! "$ #! #(%)(,%)(4 "5 #!/%6 7 (8% &%&#)&# +"2" "9 #!(%(& #%4 ), 3 %4 1 :&+1 "$0+.;$ &%(8%,< ,(! 9 ’#!%,&6 &%/## "2 ’&#!4 /## "" #!&1 %&##,&## &,%/’ == #! ##4 4 ()% ##&) =. #! &4 ,&%& # %4 ,("2";> % ";.2> $’4 ?(% & #, &(#/+)%&&";"=+ &4 % #%&& ";"5+%"’4 )&1 %&% )( &4 %%";.2>"’4 ,(+?(& % &)’&)%#, 3 4 &(#/ 7 &@ & &%4 4 , 4 ,?(#(, ,(# ##&#%# & #4 & =* #!1 &8%(8% <##& =5 #!,,)%##8% <##& ,(! =2 #!&%/##’ 316 317 318 319 Page 1 This Storm Drainage Assessment fulfills the City’s requirement for the redevelopment of the Gallatin Valley Seed Co. Building C in Bozeman, Montana. The project site is approximately 1.15 acres with the proposed redevelopment covering the south half of the subject parcel. The parcel contains three buildings with a narrow passageway connecting buildings B and C, three paved parking areas (2 on the west side of the buildings), sidewalks, associated infrastructure and landscaping. The site is bordered by Olive, Wallace and Curtis Streets with a paved alley along the west property line. A storm water plan with calculations was prepared by Lowell Springer of the Springer Group, P.C., dated June 21, 1993. The drawing was stamped as received by the Bozeman City-County Planning Office, dated June 22, 1993. According to this plan, the runoff from the east parking area flows to the southwest corner of the lot. An 8” PVC pipe conveys the runoff under the passageway to the west side of the building C. A shallow swale conveys the storm water from the pipe to a retention pond located on the west side of the building. The Building C western parking area sheet flows to the gutter along the easterly edge of the parking area. The collected runoff is conveyed to the north and collects at the northeast corner of the area. Buildings A and B do not have gutters and all of the roof runoff is allowed to flow directly from the roof to the ground. Building C has several roof gutters over the doors to divert the roof runoff away from the doorways. The roof is sloped to the west and a gutter collects approximately half of the roof with the downspout discharging to the south at the southwest corner of the building. A visit to the site revealed that none of the storm water components proposed in the June 1993 storm water plan were constructed. However, the owner informed us that a trench drain was installed at the low point in the northwest corner of the east parking area. While there is evidence of sediment accumulation at the low point of the parking areas, there is no evidence of ponding after major storm events. It is anticipated that the project will continue the use and maintain the functionality of the trench drain. All modifications for this project occur on site along the building perimeter. The project includes the removal and placement of new sidewalks, deck, the installation of new sewer and water service lines and a small mechanical yard. The improvements create an additional 39 square feet of impervious area (see Figure 1 for proposed improvements). Storm water from the east parking area will continue to flow toward the northwest corner of the parking area. The existing landscaped islands will be modified to allow for the collection and treatment of storm water runoff in the form of rain gardens. The remaining runoff will be collected and conveyed to the existing trench drain located under the northeast corner of the parking area. A portion of the storm water generated by the west parking area will be collected in the modified landscaped island (rain garden). The remaining storm water will be conveyed under the sidewalk to a rain garden on the east side of the building for treatment and retention. The roof 320 Page 2 downspout will continue to discharge to the south into a retention area between the building and the sidewalk. Although this project is a redevelopment since the proposed storm water system was never constructed, the storm water should be address at this time. However, due to the tight site constraints, the existing landscaped areas will be re-constructed into rain gardens and retention areas to meet the water quality and quantity standards of the collected runoff. G:\GYC\Phase1\Kris Desper\Storm Drainage Assessment.doc 321 322 323 324 325 326 327 328 329 UPUPDNDNREFDNDNA2021A2012A2011A2022EXTERIOR PLANTER BEDS -DESIGN T.B.D.EXTERIORSEATING - SEEDETAILS BELOWNANAWALL FOLDING WALL SYSTEMBIKE STORAGE - BIKE RACKDESIGN T.B.D.EXISTING GAS METER TOREMAIN. PROVIDE MINIMUM4' CLEAR IN FRONT OFMETER AS PERNORTHWESTERN ENERGYFORM NO. 3273 03/09EXTERIOR PATIOBATHBATH4' - 0"ELEC.OFFICEOFFICEOFFICESTORAGEHR RECORDSWORKROOMREC.REC.WAITINGMEETINGCONFERENCEENTRYDATA/COMP.MECH.MEETINGSTORAGESTORAGEOFFICEBREAKKITCHENBREAKOFFICEOFFICEUP TO STORAGE ONLY MEZZANINERECYCLINGSTORAGEJANITORSSHOWER/BATHSHOWER/BATHOFFICELOCKERSEXISTING BUILDING CONNECTOR TO BE DEMOLISHED. SALVAGEALL SIDING MATERIAL FOR REUSEMECHANICAL PAD ANDSCREEN - SEE 4/A201FOR SCREEN DETAIL2' - 0"16' - 6"2' - 2"EXTERIOR PATIOSTORAGEGROSS FLOOR AREA MINUS WINDOWDISPLAY AREA, STORAGE, TOILETS,MECHANICAL SPACES, STAIRWAYS ANDCORRIDORS AS PER CITY OF BOZEMANU.D.O. CHAPTER 18.46 - 4638 SFOFFICEOFFICE12' - 2 1/2"8' - 1 1/4"14' - 8"7' - 11 7/32"43' - 10 29/32"6' - 11"150' - 6 13/16"60' - 5 1/8"COURTYARD SCREENWALL - SEE4/A202R 2' - 6"2X4 SEAT AND FRAME - PROVIDE 2COATTS LOW VOC SEALANT/UVPROTECTANT PRIOR TO INSTALLATIONPAINTED BLACK STEEL BRACKETS ANDSUPPORTS1' - 6"4' - 0"9"2"2X4 BENCH SLATS - ALLOW 1/2"BETWEEN SLATSPAINTED BLACK STEELSADDLE BRACKET ANDSUPPORT1' - 5 1/2"1' - 6"4' - 0"1' - 6"CHECKED BY:CTA #DATE:DRAWN BY:SHEETREVISIONS:COPYRIGHT 2009CTA, INC.ALL RIGHTS RESERVEDNOT FOR CONSTRUCTION - PRELIMINARY DESIGNC:\RevitFiles\GYCSEED\GYED_BEN.rvtGallatin Seed Co. BuildingBozeman, MTBTERSFGYC_SEEDFLOOR PLANA101Greater Yellowstone Coalition5.27.09PRELIMINARY CUPCITY REVIEW 1/8" = 1'-0"A1011Level 1GENERAL NOTE: ALL EXISTING MATERIALS WITHIN BUILDING 'C' OF THE GALLATIN SEED CO. ARE TO BE ASSESSED AT DEMOLITION FOR POTENTIAL REUSE DURING THE CONSTRUCTION PROCESS. DESIGN ELEMENTS WILLVARY DEPENDENT UPON FINAL ASSESSMENT OF INTERIOR SALVAGED MATERIALS. EXTERIOR ELEMENTS IN CONSIDERATION FOR MATERIALS REUSE INCLUDE BUT ARE NOT LIMITTED TO: BIKE RACKS, DECK RAILINGS,SCREEN WALL DETAILS1. ALL EXISTING EXTERIOR SIDING TO BE REMOVED, CATALOGUED, AND STORED FOR REUSE AS NEW SIDING. SIDING TO BE REPLACED IN ORIGINAL LOCATIONS.2. NORTH SIDE SIDING TO BE REMOVED AND USED AS INFILL SIDING WHERE NEEDED. CORRUGATED BONDERIZED METAL TO BE USED AS REPLACEMENT MATERIAL FOR NORTH ELEVATION - SEE ELEVATION SHEETS3. ALL EXISTING EXTERIOR WINDOWS TO BE REMOVED. EXISTING CLERESTORY WINDOWS TO BE SALVAGED AND REUSED AS INTERIOR WINDOWS WHERE ACCEPTABLE4. ALL EXISTING EXTERIOR LOADING DOCK DOORS TO BE REMOVED.5. ALL INTERIOR ELEMENTS EXCLUDING STRUCTURAL MEMBERS AND EXTERIOR WALL FRAMING ARE TO BE DEMOLISHED WITH CARE, ASSESSED FOR REUSE, AND RECYCLED WHERE EVER POSSIBLE.6. DEMOLISHED PARTITION WALL FRAMING WILL BE SALVAGED FOR REUSE IF THERE IS NOT SIGNIFICANT DAMAGE TO SAID MEMBERS.DEMOLITION NOTES: 3/4" = 1'-0"A1012EXTERIOR SEATING ELEVATION 3/4" = 1'-0"A1013EXTERIOR SEATING SECTION 3/4" = 1'-0"A1014EXTERIOR SEATING PLAN330 Greater Yellowstone CoalitionLevel One (existing)101' - 6"Level 1 (new)101' - 10"PARAPET120' - 0"T.O. SCREEN WALL108' - 0""GREATER YELLOWSTONECOALITION" SIGNAGE TO BE PAINTEDON TO EXISTING METAL SIDINGROOF MOUNT SOLARCOLLECTORS. SIZE ANDLOCATION T.B.D.PROVIDE BLACK PIPEHANDRAIL W/ TIMBERTOP RAIL AND TIMBERBALUSTERSPROVIDE ADA ACCESSIBLEENTRY RAMPPROVIDE NEW CURTAIN WALLWINDOWS. WINDOWS TO BESET BACK 4' FROM EXISTINGFACE OF BUILDINGPROVIDE PEDESTRIANBENCHES IN FRONT OFPLANTER BOXES. WOODBENCHES ON STEELSUPPORTSPROVIDE NEW GRASSROOF AWNINGST.O. BENCH @ 18" ABOVE GRADEPROVIDE SAFETY LIGHTING ATENTRY SOFFIT. LIGHT FIXTURES TOBE FULL CUTOFF LUMINARESLevel One (existing)101' - 6"Level One (existing)101' - 6"Level 1 (new)101' - 10"PARAPET120' - 0""GREATER YELLOWSTONECOALITION" SIGNAGE TOBE PAINTED ON TOEXISTING METAL SIDINGRECLAIMED TIMBER &EXPOSED BLACK STEELCANOPY BRACINGEXISTING CONNECTIONBETWEEN BUILDINGS "B" AND"C" TO BE DEMOLISHED.SIDING IS TO BE SALVAGEDFOR FUTURE REUSEPROVIDE NEW GRASSROOF AWNINGSPROVIDE NEW PARAPETCAP TO MATCH EXISTINGSIDINGEXISTING EXPOSEDBOARD FORM CONCRETETO REMAINREMOVE EXISTING SIDING TOPROVIDE AIR INFILTRATIONRETARDER. CATALOG SIDINGAND REPLACE IN ORIGINALPOSITIONPROVIDE NEW WINDOW.DETAIL TO MATCH EXISTINGPROVIDE NEW WINDOW.DETAIL TO MATCH EXISTINGPROVIDE NEW WINDOW.DETAIL TO MATCH EXISTINGPROVIDE NEW WINDOW.DETAIL TO MATCH EXISTINGPROVIDE NEW CURTAINWALL GLASS SYSTEM ATEXISTING OVERHEAD DOORLOCATIONSEXISTING SURFACEMOUNT LADDER TOBE REMOVED10'-0" T.O. SIGNAGE3'-6" T.O. RAIL1' - 10"DOUBLE 2X4 RECLAIMED TIMBERBALUSTERS @ 48" O.C.1x4 RECLAIMED TIMBER SLATS -PROVIDE 1/2" GAP BETWEENSLATSPROVIDE 4" AIR GAP AT GRADE2X4 RECLAIMED TIMBERBALUSTERDOUBLE 2X4 RECLAIMED TIMBERBALUSTERS @ 48" O.C.RECLAIMED CORRUGATEDSTEEL SIDING TO MATCHBUILDING B SIDING - VERIFYCMU FOUNDATION/BASE - TYP.OUTLINE OF NEW CONCRETE PADSIGNAGE TO BE PAINTED ON TO EXISTING METAL SIDING. COLOR TO BE SW2348 (YELLOW CORN) WITHSW2132 (GRAY BRIDGE) OUTLINE. SIGNAGE LOCATED ON SOUTH AND EAST ELEVATIONS. FONT TO BE TIMESNEW ROMAN - BOLD160 SF OF SIGNAGE ALLOTTED TO GALLATIN SEED CO. BUILDINGS A,B,C (FIGURE SUPPLIED BY CITY OFBOZEMAN REPRESENTATIVE VICKI HASSLER)SIGNAGE ALOTMENTS:BUILDINGS A&B: APPROX 40 SF CURRENTLY USEDBUILDING C: 56 SF SIGNAGE PROPOSED (2 SIGNS @ 28 SF EA.)16' - 4 7/32"1' - 9"9 3/8"CHECKED BY:CTA #DATE:DRAWN BY:SHEETREVISIONS:COPYRIGHT 2009CTA, INC.ALL RIGHTS RESERVEDNOT FOR CONSTRUCTION - PRELIMINARY DESIGNC:\RevitFiles\GYCSEED\GYED_BEN.rvtGallatin Seed Co. BuildingBozeman, MTBTERSFGYC_SEEDEXTERIORELEVATIONS/SIGNAGEA201Greater Yellowstone Coalition5.27.09PRELIMINARY CUPCITY REVIEW 1/8" = 1'-0"A2012SOUTH ELEVATION 1/8" = 1'-0"A2011EAST ELEVATION 3/8" = 1'-0"A2014MECHANICAL SCREEN 3/8" = 1'-0"A2015GARBAGE ENCLOSURE 1" = 1'-0"A2013SIGNAGE DESIGN331 Level One (existing)101' - 6"Level 1 (new)101' - 10"PARAPET120' - 0"T.O. SCREEN WALL108' - 0"DOWNSPOUT PIPED TO BURIEDCISTERN FOR ROOFTOP WATERCATCHMENT. SIZE ANDLOCATION OF CISTERN TO BEDETERMINED. COLLECTEDWATER TO BE USED FOR ONSITE IRRIGATIONDOWNSPOUT PIPED TOBURIED CISTERN FORROOFTOP WATERCATCHMENT. SIZE ANDLOCATION OF CISTERN TOBE DETERMINED.COLLECTED WATER TOBE USED FOR ON SITEIRRIGATIONMECHANICAL SCREEN.1X4 WOOD SLATATTACHED TO STEELFRAMECORRUGATEDCLADDING AT DECKBASESSCREENED BICYCLESTORAGEVEGETATED SCREEN WALLS.ALLOW FOR NATIVE SPECIESPLANTINGS TO COVER WALLS.SEE 4/A202ROOFMOUNT SOLAR ANDHVAC EQUIPMENT. SIZE,DESIGN AND LOCATION TBDPROVIDE ALL NEWWINDOWS. LOCATION, SIZEAND AMOUNT TBDDEPENDING UPON SOLARANALYSIS. CURRENTCONFIGURATION IS ANESTIMATED RATIOEXISTING GAS METERTO REMAIN. PROVIDEMINIMUM 4' CLEAR INFRONT OF METERAPPROX. 9'-0" ABOVE FINISHED ROOFSAFETY LIGHTING AT ENTRYSOFFIT. FIXTURES TO BEFULL CUTOFF LUMINAIRES8' - 0"3' - 0"Level One (existing)101' - 6"Level 1 (new)101' - 10"PARAPET120' - 0"T.O. SCREEN WALL108' - 0"EXISTING CONNECTION BETWEENBUILDINGS 'B' AND 'C' TO BEDEMOLISHED. SIDING IS TO BESALVAGED FOR REUSE ANDPATCH OF RESIDUAL OPENINGEXISTING METAL SIDING TO BE REMOVED ANDREUSED ON EAST, SOUTH, WEST, ELEVATIONS ASNEEDED. REPLACEMENT MATERIAL TO BE SIMILARTO EXISTING.MECHANICALEQUIPMENT SCREENEXISTING SURFACE MOUNT LADDER TO BEREMOVED. ROOF ACCESS TO BETHROUGH INTERIOR MECHANICAL ROOMEXTERIOR WALL TO BERATED AT 1-HOUR ULLISTINGSALVAGE EXISTING EXTERIOR SLIDINGDOOR AND ASSOCIATED HARDWAREFOR REUSE AT INTERIOR. INFILLRESIDUAL OPENING TO MATCHEXTERIOR WALL SURFACE12" CONCRETE PIER - MIN.IMBED 36" BELOW GRADE4X4 RECLAIMED TIMBERGRADE BEAM1/2" BLACK STEEL RODS@ 4" O.C.RECLAIMED TIMBERBALUSTERS - STAINED ANDSEALED W/ UV PROTECTANT2X4 RECLAIMED TIMBERRAILING CAP. SEEELEVATIONS FOR VARYINGHEIGHTSDOUBLE 2X4 RECLAIMED TIMBERBALUSTERS @ 48" O.C.1/2" BLACK STEEL RAILS @ 4" O.C.PROVIDE 4" AIR GAP AT GRADE2X4 RECLAIMED TIMBERBALUSTERCHECKED BY:CTA #DATE:DRAWN BY:SHEETREVISIONS:COPYRIGHT 2009CTA, INC.ALL RIGHTS RESERVEDNOT FOR CONSTRUCTION - PRELIMINARY DESIGNC:\RevitFiles\GYCSEED\GYED_BEN.rvtGallatin Seed Co. BuildingBozeman, MTBTERSFGYC_SEEDEXTERIORELEVATIONSA202Greater Yellowstone Coalition5.27.09PRELIMINARY CUPCITY REVIEWEXISTING OVERHEAD POWERLOCATION TO REMAIN. SERVICESIZE TO BE UPGRADED IFNECESSARY 1/8" = 1'-0"A2021WEST ELEVATION 1/8" = 1'-0"A2022NORTH ELEVATION 3/8" = 1'-0"A2023RAILING/SCREENWALL SECTION 3/8" = 1'-0"A2024RAILING/SCREENWALLELEVATION332 planning • zoning • subdivision review • annexation • historic preservation • housing • grant administration • neighborhood coordination CITY OF BOZEMAN DEPARTMENT OF PLANNING AND COMMUNITY DEVELOPMENT Alfred M. Stiff Professional Building 20 East Olive Street P.O. Box 1230 Bozeman, Montana 59771-1230 phone 406-582-2260 fax 406-582-2263 planning@bozeman.net www.bozeman.net MEMORANDUM TO: Design Review Board FROM: Allyson C. Bristor, Associate Planner RE: Gallatin Valley Seed Co. Building/Greater Yellowstone Coalition CUP/COA/DEV – #Z-09092 DATE: June 19, 2009 PROJECT LOCATION The Gallatin Valley Seed Company complex consists of three structures and is located between East Olive and East Curtiss Streets, on the west side of South Wallace Avenue. The property addressed as 201, 209 and 215 South Wallace and is legally described as Lots 11-20, Block D, Rouse’s First Addition, City of Bozeman, Gallatin County, Montana. The property is zoned as R-4 (High Density Residential District) and is located within the Neighborhood Conservation Overlay District. The Gallatin Valley Seed Company property is individually listed on the National Register of Historic Places, due to its association with Gallatin Valley’s seed pea industry from the late 1910s through the 1940s. The historic complex is composed of the seed plant (Building B) and two warehouses (Buildings A and C). The wood-frame and metal covered seed plant and brick-veneer warehouse (Building A) were built in c. 1917 as detached buildings. The seed plant was likely built first because it was where the peas were cleaned and sorted. The long, wood-frame and metal covered warehouse (Building C) was built c. 1945 south of the seed plant and is listed non-contributing to the historic site. All of the buildings are now attached with framed-in walkways. PROJECT PROPOSAL The Greater Yellowstone Coalition (GYC), and their representatives CTA Architects Engineers, submitted a Conditional Use Permit and Certificate of Appropriateness with Deviations application to the Department of Planning & Community Development. The application is seeking to expand office use on the Gallatin Valley Seed Company complex. The proposal is to establish GYC’s headquarters office in Building C of the Gallatin Valley Seed Co. complex, which is approximately 9,000 square feet in size. The proposal does not result in any changes of use for Buildings A and B of the complex. A combination of office, warehouse and residential uses were approved in a Conditional Use Permit application for the Gallatin Valley property in 1993. Only warehouse use was approved in Building C with the previous CUP. Because the current proposal is seeking to expand a lawful nonconforming nonresidential use (office), it must be approved through the granting of a conditional use permit by the City Commission. The application will also be reviewed by Administrative Design Review (ADR) Staff, the Development Review Committee (DRC), the Design Review Board (DRB) and the Historic Preservation Advisory Board (HPAB). The proposal requested a deviation for a reduction in parking, up to 12 spaces. Planning Staff has indicated their support of a parking deviation of no more than 25% of the total parking provided on site, which the applicant’s request falls under. 333 Page 2 An additional deviation was found during the preliminary review of the project. A portion of the exterior deck proposed on the south elevation is covered and encroaches into the required 15-foot front yard setback along Curtiss Street. The deviation is specifically for a 2’ x 21’ area of the covered deck to increase in the required front yard setback. Staff is supportive of the deviation. PROJECT DESIGN The GYC proposal does include exterior alterations to Building C and the site. The connection between Buildings B and C will also be removed to allow for a pedestrian pathway. Building C will maintain its existing corrugated metal siding. The siding will be temporarily removed during construction, but catalogued so that it can be restored to its original position. The building insulation will be replaced. Insulation will be added to the top of the existing roof in order to preserve and expose the existing interior wood ceiling. Exterior windows will be removed and updated with fixtures that are in the same character as the existing windows in Buildings B and C. Loading dock doors will be removed and replaced with store front glass. Additional clerestory windows will be added to the east and west elevations. The proposal will include establishing a new water and sewer connections to Building C. An independent set of services will be brought in from Wallace Avenue. Additional improvements to the site include benches and an informational landscaping element along the southern elevation, decks along the south and west elevations, and bike racks for GYC employees. Also, landscaping plantings will be added to the existing and new parking lot islands. The existing parking areas on site will be reconfigured to increase the number of parking spaces. Though Building C is listed as non-contributing on the historic inventory, it is still important to approach its rehabilitation and remodel in a historically appropriate manner. Though the exterior alterations change the appearance of the building, namely with the addition of the store front style windows, the form and character of the building is retained with the repair and reinstallation of the metal siding and the preservation of the building footprint. The proposed uses are found as appropriate by Planning Staff for the adaptive reuse of the building. STAFF COMMENTS ADR Staff is looking for additional design recommendations or comments from the DRB and HPAB. Staff asks the DRB and HPAB to relate their comments to the Certificate of Appropriate Standards, per 18.28.050 of the Bozeman Unified Development Ordinance, and the Design Guidelines for Historic Preservation & the Neighborhood Conservation Overlay District. The Introduction, Chapters 2 and 4, and the Appendix of the Design Guidelines are relevant to this project, as it is deemed as “new infill and construction in the Neighborhood Conservation Overlay District.” For discussion purposes, listed below are possible design and historic preservation conditions that are being considered by ADR Staff. Staff feels like the majority of these conditions are being addressed with the current proposal. 1. The Montana Architectural and Historic Inventory/National Register file of the Gallatin Valley Seed Co. Property shall be corrected and updated with the proposal, to reflect changes to the site since the property’s initial listing on the National Register of Historic Places. The updated inventory shall be submitted with the final site plan application. 2. Scaled drawings, both plans and elevations, of Building C shall be submitted with the final site plan application. 3. The existing loading dock doors on the east and south elevations of Building C shall be replaced with window glazing that is the same size and dimensions. 4. All of the existing door locations on the east and south elevations of Building C shall be replaced with doors that are the same size and dimensions. 5. All of the new ground floor window glazing proposed in Building C shall be distinguishable from glazing added in the original loading dock door locations. 334 Page 3 Please indicate the conditions that you believe are justifiable for the project scope. CONCLUSION The DRC will complete their review of the project on June 24, 2009. The Bozeman Historic Preservation Advisory Board will review the project on June 25, 2009. The DRB is charged with providing recommendations to the City Commission. ADR Staff will compile comments and recommendations from all boards and include them in the City Commission’s staff report. The City Commission is scheduled to review the project at their public hearing on July 6, 2009. Encl: Applicant’s submittal materials CC: Gallatin Valley Seed Company, Inc., 201 South Wallace Avenue, Bozeman, MT 59715 Greater Yellowstone Coalition, PO Box 1874, Bozeman, MT 59771 CTA Architects Engineers, 1143 Stoneridge Drive, Bozeman, MT 59718 335   Historic Preservation Advisory Board – 25 June 2009    Members Present:  Courtney Kramer (staff liaison), Anne Sherwood, Courtney Gunderson, Mark  Hufstetler (chair), Jane Davidson Klockman, Richard Brown, Lesley Gilmore, Ryan Olson, Mike  Neeley, Lora Dalton‐‐ quorum established    I. Call to Order  II. Minutes from the April meeting were unavailable, and will be approved in August.  III. Public Comment  a. There were no members of the public in attendance.  IV. Introduction of Invited guests:  a. Mike Peris, of the Greater Yellowstone Coalition  b. Valarie, of the GYC  c. Deb Rosa, of CTA Architects and Engineers  d. Ben Elias, CTA  e. Kristin________, with Legends Studio  f. Kira Stoops, Legends Studio  V. Project Review and recommendations to staff  a. Gallatin Valley Seed Company Adaptive Reuse by the Greater Yellowstone  Coalition; CTA the design team  - Ben presented the project. The building is a steel 1940’s warehouse,  which GYC would like to reuse for their headquarters in Bozeman.  They chose the building for the high level of possible salvage options it  offered. The goal is to have it LEED certified.  - Comments by Preservation Board members:  Lesley Gilmore abstained from commenting on this project, as she is  employed by CTA.   1. Mark Hufstetler: Like the notion of GYC going into a building  that is historic and treating the building with a lot of sensitivity.  He was concerned with the south elevation and sees it as a  disconnect with the rest of the building. He is uncertain if it  respects the remainder of the structure. He thinks the materials  aren’t quite a match. He does understand the need to define  the entrance. Mark overall liked the project and is excited with  the possibility of introducing light wells in the center of the  building to provide natural lighting.   2. Lora Dalton: Her impression of the project is very positive and is  excited to see good adaptive reuse of the industrial building.  She like the attempt to soften the building towards the  residential to the south. She is very impressed.   3. Jane Klockman: “I like it, I guess that is the bottom line.” Jane  noted that there is an awful lot of vertical rather than  horizontal, asks about the landscaping: conifers vs. deciduous?  a. Becky responds that the tight space on the lot require  mostly deciduous with low lying conifers.   336 4. Mike Neeley: Thought the project looks good. Likes maintaining  the majority of the structure and sees the alterations as adding  to the evolution of the building.  5. Richard Brown: Like maintaining the original building and  configuration of window openings. Understands Mark’s  concerns and can’t come up with something better.  6. Anne Sherwood: Wonderful to see an application which doesn’t  include demolition. She believes it is really exciting to see new  use in the building.   7. Courtney Gunderson: likes the detail of the reuse and  appreciates all of the effort.   - Anne Sherwood motions to express support for the overall concept of  the project and commend the GYC for their adaptive reuse project,  with the condition that high quality exterior and detail photos of the  building “as‐is” be taken prior to alteration.  - Richard Brown seconds.   - Motion passes unanimously.   b. American Legion new building, Legends Studios the design team  - Kira presented the project. Legends is working with the American  Legion to replace the building destroyed by fire. The Legion members  are interested constructing a building which better fits their needs  and will generate more income. In the new building the 1st floor  becomes the bar,  the basement remains unfinished and the second  floor becomes flexible space for their meetings or available for rent.   - Comments by the Preservation Board Members:  1. Richard Brown: He always through that the older building was  ugly. He’s concerned that the design for the alley side is too  clean and too finished. Overall he likes the look of the front  elevation and the depth of the windows.   2. Anne Sherwood: Doesn’t have a problem with the back, but is  concerned that the design too much reflects the Jacobs Crossing  building. She likes the sunshades, and would like to see the 1st  floor windows be 1 large plate of glass to be more reflective  of2009 and 2010. Reccomends putting the dates of he building  on the new building as cornerstones.   3. Lesley Gilmore: Likes the two different elevations, begins review  with the back elevation. She sees the split face block  everywhere, and recommends using a flat block instead of split  face. She notes that the ramp will add layering to the elevation.  On the front elevation, Lesley is concerned with the materials.  She likes the combination of sandstone and brick, but urges the  designer to re‐think the use of soft sandstone on the base of a  building. It will not wear well over time; maybe granite instead?  Lesley notes that the base of the front elevation looks very  1907‐1910, while the top looks very 2009. Maybe the windows  should be double hung? Are the awnings oppressive? Could  stainless steel be used to differentiate new from old. Lesley  expressed concern that the articulation between stories was  kind of heavy. She recommends thinner pilasters or thinner  brick.  4. Courtney Gunderson: Likes the back entry and think its fits well  in the same alley with the pour house. Likes the entry and the  337 neon sign. Believes strongly that the sign old sign should be on  the front (Main Street) elevation. Notes that the middle of the  front elevation is heavy, and would like to see the base of the  building feel more substantial and bulky in order to support the  second story.   5. Ryan Olson: Would meld Anne and Lesley’s comments. Does  believe the building reminds him of the Jacob’s Crossing  building. Also thinks the old sign should go on the Main Street  elevation, possibly above the entrance to the second story.   6. Lora Dalton: Recalls earlier post‐explosion, when the  community’s highest hope was that building built post‐ explosion are really good buildings. She recognizes that the  client isn’t willing to go super modern, and adores the back  which she thinks looks like an alleyscape should look. Definitely  agrees that the sign should go on the front. The sign IS the  Legion.   - Anne Sherwood motions to recommend approval of the new legion  with the strong recommendation that the sign go on the Main Street  elevation and with consideration of adding cornerstone dates as well  as other comments in the minutes.  - Richard Brown seconds  - Motion passes unanimously.  VI. Chair’s Report  a. Reappointment of members by the City Commission.  - Ryan Olson motions to recommend the commission re‐appoint all  exiting board members who reapply.  - Lesley Gilmore seconds  - Motion passes unanimously  b. Discussion of the BHPAB’s interaction with the Friends of the Story Mansion  group.   - Jane Klockman relays a request from the Friends of the Story Mansion  group for a resolution of support for the Friends by the BHPAB, as well  as help with events.   - Mark Hufstetler feels strongly that it is not the BHPAB’s position to  support other boards. He doesn’t think it’s a good idea to get too  heavily involved with fundraising.   - After some discussion, Lora Dalton notes that the BHPAB should have  no problem supporting the mission statement of the FoS. But on a  practical working basis the BHPAB should review partnering on an  event by event basis.   - Lora Dalton motions that the education and outreach subcommittee  coordinate with other preservation‐minded organizations.  - Anne Sherwood Seconds  - Motion passes  VII. Subcommitee meetings were scheduled as:  a. Education and Outreach, Tuesday, July 7 at 6:30pm. Location TBD?  b. Planning and Policy, Tuesday, July 14 at 6pm at Richard Brown’s house  VIII. Meeting adjourned.   338