Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
030 E101 Electircal Legend, Notes & Details
JACKSON, RENFRO & ASSOCIATES, INC.SUD BLOCK 3COTTAGES OF BOZEMEMANBOZEMAN, MONTANArOBERT C. rENFRO, PE bobby@jraee.com (D) 205.536.7114 (P) 205.995.1078 E / E C T R I C A / E N * I N E E R I N * & ' E S I * N IQYHrQHVV FHQWHr SNZ\, S8ITE BIR0IN*+A0, A/ABA0A REVISIONS DESIGNED DRAWN PROJECT NUMBER CHECKED 225129 RCR RCR RCR NO.DATE DESCRIPTION SHEET TITLE ISSUE DATE 09/02/2025 SEQUENCE OF 10 SHEET NO. © 2025 JACKSON, RENFRO & ASSCOCIATES, INC. E101 ELECTRICAL LEGEND, NOTES & DETAILS 1 CONTRACTOR SHALL VISIT THE SITE OF THE WORK PRIOR TO SUBMITTING BID TO EXAMINE CAREFULLY LOCAL CONDITIONS AND DIFFICULTIES TO BE ENCOUNTERED. ANY DISCREPANCY BETWEEN PLANS AND EXISTING CONDITIONS SHALL IMMEDIATELY BE CALLED TO THE ATTENTION OF THE ARCHITECT. 1. REMOVE ALL EXISTING ELECTRICAL EQUIPMENT AND WIRING MADE OBSOLETE BY THIS RENOVATION AND DISPOSE OF AS DIRECTED BY THE ARCHITECT. 2. EXISTING PANEL DIRECTORY CARDS MODIFIED BY THIS RENOVATION SHALL BE RETYPED TO INDICATE CONNECTED CIRCUITS. 3. THIS CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR NECESSARY TO EXTEND CIRCUITS AND MAKE RECONNECTIONS TO ANY ACTIVE ELECTRICAL DEVICES ON WHICH THE BRANCH CIRCUIT IS INTERRUPTED BY THIS ALTERATION. CARE SHALL BE TAKEN TO INSURE THAT EXISTING PANEL AND FEEDER RATINGS ARE NOT EXCEEDED. 4. ALL EQUIPMENT SHALL BE GROUNDED AND BONDED IN ACCORDANCE WITH NEC.5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL REQUIREMENTS OF ANY LOCAL APPLICABLE CODES OR ORDINANCES, PUBLIC UTILITY COMPANIES, STATE CODE, NATIONAL ELECTRICAL SAFETY CODE AND THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE WITH THE INTERIM AMENDMENTS THERETO. 6. ALL MATERIALS SHALL CONFORM TO THE LATEST ISSUE OF ALL APPLICABLE STANDARDS AS ESTABLISHED BY EEI, NEMA, IEEE, ASTM, IPCEA, NATIONAL BOARD OF FIRE UNDERWRITERS AND UNDERWRITERS LABORATORIES, INC. 7. CONTRACTOR SHALL FURNISH ARCHITECT WITH A CERTIFICATE OF FINAL INSPECTION FROM THE INSPECTING AUTHORITY. 8. THE COST OF ALL PERMITS AND INSPECTION FEES SHALL BE INCLUDED IN THE CONTRACT PRICE.9. RIGID STEEL CONDUIT SHALL BE GALVANIZED OR SHERARDIZED, FITTINGS SHALL BE CAST FERROUS MATERIAL WITH A CADMIUM OR ZINC PLATED FINISH. 10. 11.EXCEPT AS NOTED OTHERWISE ON THE DRAWINGS, ALL POWER WIRING SHALL BE INSTALLED IN CONDUIT AS FOLLOWS: A.NON-METALLIC CONDUIT (SCHEDULE 80 RIGID PVC) SHALL BE USED FOR BRANCH CIRCUITS AND FEEDERS WHERE BELOW GRADE, OR IN CONCRETE SLAB ON GRADE. 12 WIRE AND CABLE SHALL BE COPPER AND CONFORM TO THE FOLLOWING: 1.NEC TYPE RHW/RHH - NO. 12 AND NO. 10 - SOLID 2.NEC TYPE RHW/RHH-USE - NO. 8 AND LARGER - STRANDED ELECTRICAL CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR APPROVAL COMPLETE CATALOG DATA AND SIX (6) COPIES OF MANUFACTURER'S SHOP DRAWINGS SHOWING GENERAL ARRANGEMENT AND DETAIL CONSTRUCTION FOR ALL ELECTRICAL APPARATUS EXCEPT CONDUIT, FITTINGS AND WIRE BEFORE PURCHASE AND INSTALLATION. 13. THIS CONTRACTOR SHALL LEAVE ENTIRE ELECTRICAL SYSTEM INSTALLED BY HIM UNDER THIS CONTRACT IN PROPER WORKING ORDER AND SHALL REPLACE WITHOUT ADDITIONAL CHARGE ALL WORK OR MATERIALS WHICH MAY DEVELOP DEFECTS WITHIN A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE BY THE ARCHITECT. 14. 15.ALL ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH CITY OF BOZEMAN LIGHTING STANDARDS - REVISION MARCH 2020. CONTRACTOR SHALL DOWNLOAD STANDARDS FROM CITY OF BOZEMAN MUNICIPAL WEBSITE. ALL REQUIREMENTS INDICATED IN THESE STANDARDS ARE A PART OF THE CONTRACT DOCUMENTS. GENERAL ELECTRICAL NOTES FIXTURE OUTLET - POLE LIGHT FIXTURE - QUANTITY AND ORIENTATION(S) OF LUMINAIRES AS INDICATED ON PLANS. ELECTRICAL PULL BOX - SEE FIGURES 2 AND 3 THIS SHEET. BRANCH/FEEDER CIRCUIT - CONCEALED IN WALLS OR CEILING. BRANCH/FEEDER CIRCUIT - EXPOSED ON WALLS OR CEILING. BRANCH/FEEDER CIRCUIT - CONCEALED IN FLOOR SLAB OR DIRT FILL. BRANCH/FEEDER CIRCUIT - HOMERUN - CAN BE USED WITH OTHER BRANCH/FEEDER TYPES. BRANCH/FEEDER CIRCUIT MODIFIERS: : 2#12 & 1#12G UNLESS NOTED OTHERWISE. : 3#12 & 1#12G, ETC. UNLESS NOTED OTHERWISE (TICK MARKS INDICATE CONDUCTOR QUANTITY NOT INCLUDING GROUND WIRE). : 2#10 & 1#10G UNLESS NOTED OTHERWISE (NUMBER INDICATES WIRE AWG). SIZE CONDUIT PER N.E.C. UNLESS INDICATED OTHERWISE. 10 LIGHTING PANEL - SURFACE MOUNTED. DETAIL DESIGNATOR - "A" INDICATED DETAIL MARK - "E-1" INDICATED SHEET NUMBER WHERE DETAIL IS LOCATED (TYPICAL). GENERAL ABBREVIATIONS: EX EXISTING TO REMAIN. XR EXISTING TO BE REMOVED - REMOVE ALL ASSOCIATED ELECTRICAL EQUIPMENT, DEVICES, CONDUIT AND WIRING CONNECTIONS TO OTHER ELECTRICAL ITEMS UNLESS SHOWN OTHERWISE. XRL EXISTING TO BE RELOCATED - REMOVE ALL ASSOCIATED ELECTRICAL EQUIPMENT, DEVICES, CONDUIT AND WIRING AT EXISTING LOCATION. RELOCATE ITEM TO NEW LOCATION SHOWN ON ELECTRICAL PLANS. EXTEND AND RECONNECT EXISTING CONDUIT, WIRING, ETC. TO NEW LOCATION AS REQUIRED UNLESS SHOWN OTHERWISE. XRP EXISTING TO BE REPLACED - EXTEND AND RECONNECT EXISTING CONDUIT AND WIRING TO REPLACED ITEM. TYPICAL CIRCUITRY DESIGNATIONS: 2 SETS OF 4#3/0 & 1#3G - 2 1/2"C CONDUIT SIZE. GROUND CONDUCTOR WIRE GAUGE. QUANTITY OF GROUND CONDUCTORS (PER SET) PHASE/NEUTRAL CONDUCTOR WIRE GAUGE. QUANTITY OF PHASE/NEUTRAL CONDUCTORS (PER SET). QUANTITY OF PARALLEL SETS OF THE PHASE/NEUTRAL CONDUCTORS, GROUND CONDUCTOR AND CONDUIT SPECIFIED. GENERAL ELECTRICAL LEGEND