Loading...
HomeMy WebLinkAbout004 C-101 DETAILED SITE PLANXXXXXX X X XXXXXXXXXXXXXXXUTUEUE UEUEUEUEUEUEUEUEUE UEUEUEUEUEUEUEUEUEUEUEUEUE UTUTUTUTUTUTUTUTUTUTUTUTUT SHEET NUMBER:REVISION:C-101 DESCRIPTIONREV.DATEBY Copyright © 2026 ATC IP LLC, All Rights Reserved.326 TRYON ROADRALEIGH, NC 27603-3530OFFICE: (919) 661-6351www.tepgroup.net TEP IS A FAMILY OF COMPANIES LICENSED TO PROVIDE DIFFERENT SERVICES INDIFFERENT JURISDICTIONS. DEPENDING ON THE JURISDICTION, PROFESSIONALENGINEERING AND LAND SURVEYING SERVICES ARE PROVIDED BY TEP OPCOLLC, A DELAWARE LIMITED LIABILITY COMPANY, TEP ENGINEERING, LLC, A NORTHCAROLINA PROFESSIONAL LIMITED LIABILITY COMPANY, OR M&H ENGINEERING,LLC, A NEW YORK PROFESSIONAL LIMITED LIABILITY COMPANY. GENERALCONTRACTOR SERVICES ARE PROVIDED BY TEP OPCO LLC, A DELAWARELIMITED LIABILITY COMPANY. WE ACQUIRE THE REQUISITE LICENSES IN EACHSTATE. ADDITIONAL INFORMATION CAN BE OBTAINED FROM THE COMPANY. 419657 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: BRIDGER VIEW MT BRIDGER RD_ATC (419657) ATC SITE NAME: 705 BRIDGER DR BOZEMAN, MT 59715 BRIDGER RD_ATC (419657) 15314363 MT05232A 02/18/26DATE DRAWN: ATC JOB NO: CUSTOMER ID: CUSTOMER NAME: SEAL: 100% CONSTRUCTION0 07/25/25SRZ 02/18/26 100% CONSTRUCTION1 09/24/25SRZ 100% CONSTRUCTION2 02/18/26RMJ A PRELIMINARY PRB 06/10/25 2 DETAILED SITE PLAN 0 10'20' SCALE: 1"=10' (11X17) 1"=5' (22X34) 1 DETAILED SITE PLAN SCALE: 1" = 10' PROPOSED CABLE NOTES: 1. ESTIMATED LENGTH OF PROPOSED CABLE IS 40m.ESTIMATED LENGTH OF CABLE WAS PROVIDED BYCUSTOMER OR CALCULATED BY ADDING THE RADCENTER AND THE DISTANCE FROM THE SHELTERENTRY PLATE TO THE TOWER (ALONG THE ICEBRIDGE) AND A SAFETY FACTOR MEASUREMENT OF15% (OF THE TWO PREVIOUS VALUES), CDS DEFERTO GREATEST CABLE LENGTH. 2. ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. IF ADEQUATE SPACEEXISTS, ROUTE CABLES THROUGH ENTRY PORTHOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXITPORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE,ATTACH CABLES USING STAND-OFF ADAPTERS MOUNTED TO TOWER USING STAINLESS STEELBANDING. ADEQUATELY SECURE CABLES USINGEITHER APPROPRIATELY SIZED STAINLESS STEELSNAP-INS OR MOUNTING HARDWARE AND BRACKETSAS SPECIFIED BY CABLE MANUFACTURER. SITE PLAN NOTES: 1. THIS SITE PLAN REPRESENTS THE BEST PRESENTKNOWLEDGE AVAILABLE TO THE ENGINEER AT THETIME OF THIS DESIGN. THE CONTRACTOR SHALLVISIT THE SITE PRIOR TO CONSTRUCTION ANDVERIFY ALL EXISTING CONDITIONS RELATED TO THESCOPE OF WORK FOR THIS PROJECT. 2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAXCABLE ARE SHOWN FOR REFERENCE ONLY.CONTRACTOR SHALL CONFIRM THE EXACTLOCATION OF ALL PROPOSED AND EXISTINGEQUIPMENT AND STRUCTURES DEPICTED ON THISPLAN. BEFORE UTILIZING EXISTING CABLESUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALLVERIFY ALL ASPECTS OF THE COMPONENTS MEETTHE ATC SPECIFICATIONS. 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TOCOORDINATE WITH THE T-MOBILE REPRESENTATIVEAND LOCAL UTILITY COMPANY FOR THEINSTALLATION OF CONDUITS, CONDUCTORS,BREAKERS, DISCONNECTS, OR ANY OTHEREQUIPMENT REQUIRED FOR ELECTRICAL SERVICE.ALL ELECTRICAL WORK SHALL BE PERFORMED INACCORDANCE WITH LATEST EDITION OF THE STATEAND NATIONAL CODES, ORDINANCES ANDREGULATIONS APPLICABLE TO THIS PROJECT. LEGEND AUTOMATIC TRANSFER SWITCHATS DISCONNECTD ELECTRICALE FIBERF BOLLARDB GENERATOR RECEPTACLEG HAND HOLE, VAULTHH, V ICE BRIDGEIB KENTROX BOXK GENERATORGEN METERM LIGHTING CONTROLLC PULL BOXPB POWER POLEPP TELCOT TRANSFORMERTRN XCHAINLINK FENCE GROUNDING TEST WELL CELL SITE CABINETCSC PROPOSED 20' TOWER EXTENSION(TO BE PERMITTED AND INSTALLED UNDER A SEPARATE PERMIT) PROPOSED T-MOBILEICE BRIDGE (LENGTH 3'-3"±) 1 C-502 PROPOSED GPS ANTENNA 3 C-502 PROPOSED T-MOBILE CABLE COUNT:(2) 6/24 4AWG (LENGTH: ±40m)(2.00" / 50.8mm) HYBRID TRUNKS(ROUTED PER TOWER NOTE 2)(REFER TO PROPOSED CABLELENGTH NOTE ON THIS PAGE) 4 C-501 PROPOSED T-MOBILE10'-0" X 12'-0" EQUIPMENT PAD 1 C-503 PROPOSED T-MOBILE10' X 15' LEASE AREA 1 C-102 PROPOSED T-MOBILE EQUIPMENTWITHIN PROPOSED EQUIPMENT PAD:(1) HPL3.1 600A SITE SUPPORT CABINET(1) PURCELL LB3 BATTERY CABINET(1) 2' x 2' AVV CUBE (1) 225A PPC(1) 200A METER AND DISCONNECT(2) ASIMs(3) ABIPs(1) AMID(1) CSR IXRE V2(2) LED LUMINARE 1 C-102 PROPOSED 10'-0" X 14'-0" WEATHERCANOPY (4 POSTS) BY PERFECTVISION (P/N: PV-EQ1014-B) ORAPPROVED EQUIVALENT 1 R-611 PROPOSED UNDERGROUNDPOWER AND TELCO CONDUITROUTED IN TRENCH 2 C-502 3'-3" PROPOSED 2-GANG METER BASETO BE MOUNTED ON PROPOSEDH-FRAME-UNISTRUT. METERS MUSTBE LABELED VERIZON & T-MOBILECONTRACTOR TO CONFIRM METER SPECS PRIOR TO CONSTRUCTIONWITH NORTH WESTERN ENERGY 1'-0"1'-0" PROPOSED NORTH WESTERNENERGY TO INTERCEPT EXISTINGVERIZON SERVICE RUN ENTERINGCOMPOUND TO BE SPLICED INTOPROPOSED 2-GANG METER BASEFOR T-MOBILE AND VERIZON PROPOSED T-MOBILE FIBERGOING THROUGH EXISTINGFIBER HANDHOLE. 6/26/2026 26265 705 Bridger Dr CONR