001 G-001 TITLE SHEET
SHEET INDEX SHEET NO:DESCRIPTION:REV:DATE:BY: G-001 TITLE SHEET 2 02/18/26 RMJ G-002 GENERAL NOTES 0 07/25/25 SRZ C-001 OVERALL SITE PLAN 2 02/18/26 RMJ C-101 DETAILED SITE PLAN 2 02/18/26 RMJ C-102 DETAILED EQUIPMENT LAYOUT 2 02/18/26 RMJ C-201 TOWER ELEVATION 1 09/24/25 SRZ C-401 ANTENNA INFORMATION & SCHEDULE 1 09/24/25 SRZ C-501 CONSTRUCTION DETAILS 2 02/18/26 RMJ C-502 CONSTRUCTION DETAILS 0 07/25/25 SRZ C-503 CONSTRUCTION DETAILS 2 02/18/26 RMJ E-101 GROUNDING DETAILS & ELECTRICAL SCHEMATIC 2 02/18/26 RMJ E-501 GROUNDING DETAILS 0 07/25/25 SRZ E-601 PANEL SCHEDULE & ONE-LINE DIAGRAM 2 02/18/26 RMJ R-601 - R-615 SUPPLEMENTAL SHEET NUMBER:REVISION:G-001 DESCRIPTIONREV.DATEBY Copyright © 2026 ATC IP LLC, All Rights Reserved.326 TRYON ROADRALEIGH, NC 27603-3530OFFICE: (919) 661-6351www.tepgroup.net TEP IS A FAMILY OF COMPANIES LICENSED TO PROVIDE DIFFERENT SERVICES INDIFFERENT JURISDICTIONS. DEPENDING ON THE JURISDICTION, PROFESSIONALENGINEERING AND LAND SURVEYING SERVICES ARE PROVIDED BY TEP OPCOLLC, A DELAWARE LIMITED LIABILITY COMPANY, TEP ENGINEERING, LLC, A NORTHCAROLINA PROFESSIONAL LIMITED LIABILITY COMPANY, OR M&H ENGINEERING,LLC, A NEW YORK PROFESSIONAL LIMITED LIABILITY COMPANY. GENERALCONTRACTOR SERVICES ARE PROVIDED BY TEP OPCO LLC, A DELAWARELIMITED LIABILITY COMPANY. WE ACQUIRE THE REQUISITE LICENSES IN EACHSTATE. ADDITIONAL INFORMATION CAN BE OBTAINED FROM THE COMPANY. 419657 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: BRIDGER VIEW MT BRIDGER RD_ATC (419657) ATC SITE NAME: 705 BRIDGER DR BOZEMAN, MT 59715 BRIDGER RD_ATC (419657) 15314363 MT05232A 02/18/26DATE DRAWN: ATC JOB NO: CUSTOMER ID: CUSTOMER NAME: SEAL: 100% CONSTRUCTION0 07/25/25SRZ 02/18/26 100% CONSTRUCTION1 09/24/25SRZ 100% CONSTRUCTION2 02/18/26RMJ A PRELIMINARY PRB 06/10/25 2 TITLE SHEET LOCATION MAPVICINITY MAP COMPLIANCE CODE PROJECT SUMMARY PROJECT DESCRIPTION SITE LOCATION BIRDIE DRT-MOBILE COVERAGE STRATEGY COLLOCATION PLAN56790EBH_SR_T_6X24 CONFIGURATION ATC SITE NAME: BRIDGER VIEW MT ATC SITE NUMBER: 419657 T-MOBILE SITE NAME: BRIDGER RD_ATC (419657) T-MOBILE SITE NUMBER: MT05232A SITE ADDRESS: 705 BRIDGER DR BOZEMAN, MT 59715 PROJECT LOCATION DIRECTIONS HEAD NORTHWEST ON I-90 W: TAKE EXIT 306 FOR N 7TH AVE 0.3MI. TURN RIGHT ONTO N 7TH AVE/I-90 FRONTAGE E 305 FT.CONTINUE STRAIGHT TO STAY ON N 7TH AVE/I-90 FRONTAGE E394 FT. TURN RIGHT ONTO W GRIFFIN DR 0.7 MI. TURN LEFTONTO BRIDGER DR/BRIDGER CANYON DR 0.3 MI. SITE WILL BEON THE (NORTH) BEHIND WAREHOUSE. ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLEDIN ACCORDANCE WITH THE CURRENT EDITIONS OF THEFOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENTAUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESECODES. 1. 2021 INTERNATIONAL BUILDING CODE (IBC) 2. 2021 INTERNATIONAL MECHANICAL CODE (IMC) 3. 2020 NATIONAL ELECTRIC CODE (NEC) UTILITY COMPANIES POWER COMPANY: NORTHWESTERN ENERGYPHONE: (888) 467-2669 TELEPHONE COMPANY: CENTURY LINKPHONE: (866) 642-0444 PROJECT TEAM APPLICANT: T-MOBILE TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ENGINEER: TEP 326 TRYON RD RALEIGH, NC 27603 T-MOBILE MW PM: LAURA BERTELLOTTILAURA.BERTELLOTTI@ T-MOBILE.COM SITE ACQ VENDOR: KIELEY PARKER 140 GRAVES TRAIL, UNIT B BOZEMAN, MT 59718 CONTACT: (240) 997-9218 KPARKER@NETWORKCONNEX.COMPLANNING APPLICANT: VINH DINH CONTACT: (206) 295-5926 VINHD@TEPGROUP.NET PROPERTY OWNER: D & F INDUSTRIES INC 3012 TESLOW DR BOZEMAN, MT 59715-1777 SITE ADDRESS: 705 BRIDGER DR BOZEMAN, MT 59715 COUNTY: GALLATIN GEOGRAPHIC COORDINATES: LATITUDE: 45.70358 LONGITUDE: -111.02699 GROUND ELEVATION: 4,711' AMSL ZONING INFORMATION: JURISDICTION: CITY OF BOZEMAN GEOCODE: 06090531201070000 1. THE FACILITY IS UNMANNED.2. A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE AMONTH FOR ROUTINE INSPECTION AND MAINTENANCE.3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LANDDISTURBANCE OR EFFECT OF STORM WATER DRAINAGE.4. NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL ISREQUIRED.5. HANDICAP ACCESS IS NOT REQUIRED.6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS ANELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEWUNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTINGWIRELESS TOWER THAT INVOLVES THE COLLOCATION,REMOVAL, AND/OR REPLACEMENT OF TRANSMISSIONEQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR §1.61000 (B)(7). PROJECT NOTES TOWER SCOPE:INSTALL (1) 20' TOWER EXTENSION (TO BE PERMITTED ANDINSTALLED UNDER A SEPARATE PERMIT)INSTALL (1) SNP8-NP PLATFORM MOUNT W/ HANDRAIL KIT INSTALL (3) AHLOB RRHsINSTALL (3) AHFII RRHsINSTALL (3) FFVV-65C-R2N23 ANTENNASINSTALL (3) AEHC ANTENNASINSTALL (2) 6/24 4AWG (LENGTH: ±40m) (2.00" / 50.8mm)HYBRID TRUNKSGROUND SCOPE: INSTALL (1) 10'-0" x 12'-0" CONCRETE PADINSTALL (1) ICE BRIDGE (LENGTH: ±3'-3")INSTALL (1) 10'-0" x 14'-0" ICE CANOPYINSTALL (1) H-FRAME WITH (1) 225A PPC, (1) 2' X 2' AAV CUBE, AND(1) MULTI GANGE METER BASEINSTALL (1) TIER STYLE LIGHT SWITCH AND GFCI COMBOINSTALL (1) HPL3.1 CABINET AND (1) LB3 BATTERY CABINETINSTALL FIBER AND POWER CONDUITSINSTALL IN HPL3.1 CABINET:(2) ASIM(s), (3) ABIP(s), (1) AMID(s), AND (1) CSR IXRE V2(s). RFDS VERSION: 1RFDS STATUS: APPROVEDPROJECT TYPE: COVERAGE STRATEGYLAST MODIFIED: 06/26/2025 9:44:17 AM NOTE: INSTALL SITE SIGNS AND LOCKS ON ALL GROUND EQUIPMENT. 6/26/2026 26265 705 Bridger Dr CONR