HomeMy WebLinkAbout031_L4.2 IRRIGATION DETAILSPRELIMINARY - FOR REVIEW FILE: PROJECT NO: CAD: QUALITY ASSURANCE: DRAWING HISTORY DATE DESCRIPTION IRRIGATION DETAILS HAGGERTY MULTI-FAMILY BOZEMAN, MTL4.2RPE 250389.01_LS_DETAILS.DWG MGB 02/27/2026 SP SUBMITTAL 06/10/2026 07/31/2026 - - - - SP 2 SUBMITTAL SP 3 SUBMITTAL - - - - -- 250389.02 ELECTRIC CONTROL VALVEN.T.S.1'-0"NOTES:1.USE TEFLON TAPE FOR ALL THREADED PIPE CONNECTIONS.2.ALL WIRES TO BE INSTALLED AS PER LOCAL CODES. NO''IN-LINE'' WIRE SPLICES WILL BE ALLOWED.2'-0"PVC MALE ADAPTOR & LATERAL LINEFINISHED GRADE1'-0" STANDARD VALVE BOXDRAIN GRAVEL1 CU. FOOTSCH.80 UNIONCENTER VALVE IN BOXSCH.80 NIPPLESCH.40 PVC SXT 90\CLASS 200 PVC PIPECONTROL WIRESSCH.40 PVC TEE OR 90ANGLE TO DIRECTLATERAL IN TRENCHSUCH THAT PIPE IS NOTCURVED OR OTHERWISESTRESSED.DOUBLEVALVE BOXESBOLTED BACKTO BACK1VARIES19.7"6.6"9.8"TRIM INDIVIDUAL RINGS TOCONFORM TO IRRIGATION HEAD CONTOURCUT AND REMOVE RINGS AND GRIDTO ACCOMMODATE IRRIGATION HEAD,SIZE VARIESIRRIGATION HEAD WITHCOVER PLATEVARIESEXCAVATE COMPACTED SUBGRADEAS REQUIRED TO PERMIT IRRIGATIONHEAD INSTALLATIONPLANSECTIONTRUEGRID WITH IRRIGATION HEADSN.T.S.2P:\250389_01_Haggerty_Lane_Survey_&_CA\CADD_C3D\PRODUCTION_DWG\250389.01_LS_DETAILS.dwg, L4.2 IRRIGATION DETAILS, 8/14/2026 4:11:44 PM, aschnaderbeck, 1:1