HomeMy WebLinkAbout021 - L503 - IRRIGATION DETAILSNOTES:1.SEE IRRIGATIONSPECIFICATION AND LEGENDFOR MORE INFORMATION.2.INSTALLATION TO BECOMPLETED IN ACCORDANCEWITH MANUFACTURER'SSPECIFICATIONS.3.MOUNT CONTROLLER AT EYELEVEL UNLESS OTHERWISENOTED.4.CONTROLLER SHALL BEHARD-WIRED TO GROUNDED110 VAC SOURCE UNLESSOTHERWISE NOTED.COORDINATE INSTALLATIONWITH ELECTRICAL.5.PROVIDE IRRIGATION ZONELIST AS SPECIFIED.1L503CONTROLLER-ROOF TOP1 1/2"=1'-0"ENSURE MINIMUMCLEARANCE FORDOOR OPENINGCONTROLLERCONDUITCONTROL WIREINTERIOR OREXTERIOR WALL-SEE PLANIRRIGATIONZONE LISTCONTROLLERPOWER SOURCE(2) EMITTERS PER SHRUBDRIP LINE LATERALLATERAL SUPPLY LINE (PVC), TYP.NOTES:1.LOCATE EMITTERS DIRECTLY OUTSIDE PLANTING PIT OF SHRUBS AND TREES.2.LOOP ALL DRIP LINE BACK TO PVC LATERAL.3.DO NOT USE 14" IRRIGATION TUBING FOR TREES, SHRUBS OR ORNAMENTAL GRASSES.(4) EMITTERS PER TREE(1) EMITTER PERPERENNIAL/ORNAMENTALGRASSNOTES:DRIP LINE STARTCONNECTION, TYP.MDPOINT SOURCE LAYOUT NTS3L503DRIP ZONECONTROLKIT, TYP.5L503DRIP MANUAL DRAIN,TYP., EACH END OFLATERAL7L5038L5034L503POINT SOURCE DRIPSECTIONNOTE:1.INSTALL TUBING AND EMITTERS PER MANUF. WRITTEN INSTRUCTIONS. LENGTH OF LINE NOT TO EXCEED500' BEFORE CONNECTION BACK TO SUPPLY LINE.2.INSTALL NUMBER OF EMITTERS PER TYPICAL POINT SOURCE DRIP LAYOUT DETAIL.3.PLANTINGS PRIMARILY TO WATER INCLUDE ISLAND PLANTERS.4.SEE PLANT IRRIGATION SPECIFICATIONS.PLANTINGS, TYP., AS NOTEDFINISH GRADE, TYP.DRIP LINE (BLANK) LATERAL AS NOTED6" SOIL STAPLE, INSTALL (1) APPROX.EVERY 3' OF TUBING AND (2) ON EACHTEE, ELBOW OR CROSSEMITTERS ASNOTEDLATERALSUPPLYBEYONDDRIP LINESTART CONN-ECTIONBEYOND, SEEDETAILWEED BARRIER FABRIC, FOR MINERAL MULCHMULCH, SEE DETAILDRIP LINEBEYONDVARIES,SEE TYPICAL POINTSOURCE DRIP LAYOUT4L503POINT SOURCE DRIP SECTION 1"=1'-0"NOTES:1.INSTALL VALVE AT HIGHESTPOINT ON DISTRIBUTIONPIPING.2.VALVE AND PIPING ASSPECIFIED.3.INSTALL ONE DRIP AIR RELIEFVALVE PER DRIP AREA- SEESCHEMATIC DRIP LAYOUTDETAIL. MULTIPLE DRIPAREAS MAY BE WITHIN ASINGLE DRIP ZONE.4.WHEREVER POSSIBLEINSTALL VALVE BOXES INPLANTING BEDS. SEEIRRIGATION PLAN FOR MOREINFORMATION.6L503DRIP AIR RELIEF VALVE1 1/2"=1'-0"FINISH GRADEVALVE BOXBRICK SUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVELVALVE BOX COVERDISTRIBUTIONPIPING, TYP.DRIP AIR RELIEF VALVEMULCHDISTRIB.PIPINGDRIP LINE TEE OR ELLNOTES:1.VALVE TO BESUPPORTED BYGRAVEL,PROVIDE BLOCKSHIM ASREQUIRED.2.SIZE VALVE ANDPIPING ASSPECIFIED.3.DIRECT BURIALWIRE MIN. 18/4WIRE TOINTERFACEPANEL. MIN. RUNOF 1,000 LF4.WHEREVERPOSSIBLEINSTALL VALVEBOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.FINISH GRADECONTROL VALVEVALVE BOX COVERSCHEDULE 80 PVCUNION, TYP.DECODER SYSTEMIF APPLICABLEMAINLINESERVICE TEE3M DBY-6 WATERPROOFCONNECTOR, TYP.18"-24" OF COILED WIRE5L503DRIP CONTROL VALVE1 1/2"=1'-0"FILTERBRICK SUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVELDISTRIB.PIPINGPRESSURE REGULATORDISTRIBUTIONPIPING7L503DRIP MANUAL DRAIN1 1/2"=1'-0"FINISH GRADEVALVE BOXBRICK SUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVEL SUMP12" X 12" X 12"VALVE BOX COVERDRIP LINE TEE OR ELLMULCHNOTES:1.INSTALL VALVE AT LOWESTPOINT ON DISTRIBUTIONPIPING.2.VALVE TO BE SUPPORTED BYGRAVEL, PROVIDE BLOCKSHIM AS REQUIRED.3.VALVE AND PIPING ASSPECIFIED.3.INSTALL ONE DRAIN VALVEPER DRIP AREA- SEESCHEMATIC DRIP LAYOUTDETAIL. MULTIPLE DRIPAREAS MAY BE WITHIN ASINGLE DRIP ZONE.4.WHEREVER POSSIBLEINSTALL VALVE BOXES INPLANTING BEDS. SEEIRRIGATION PLAN FOR MOREINFORMATION.DRIP MANUALDRAINBLANK DRIP LINE TUBING34" MALE ADAPTERPVC TEE ( SxSxT) OR ELBOWDRIP LINE TUBING TEEWEED BARRIER FABRIC, IF APPLICABLEMULCH 3" MINIMUM FINISH GRADE, TYP.SUPPLY LATERAL (PVC)8L503POINT-SOURCE (PVC TO TEE)DRIP LINE START CONNECTION,3"=1'-0"DRIP LINE TUBINGDRIP LINE TUBINGVEGETATIONFINISHED GRADESOIL CLIK CABLE TOCONTROLLERSOIL CLIK SENSORINSTALLED AT 50% OFROOT DEPTH (INSTALL IN 1CONTAINER OF EACH TYPE)ROOT DEPTHROOTSSOIL CLICK - ROOF SCALE: NOT TO SCALE9L5032L503ROOFTOP IRRIGATION POINT OF CONNECTION 1 1/2"=1'-0"SUPPLY PIPING,SEE PLUMBINGMAIN LINEBUILDING EXTERIORINTERIORBLOW OUT(WINTERIZATION)ASSEMBLY,SEE PLUMBINGBACKFLOWPREVENTERISOLATIONVALVELOCATE BELOW PEDESTALPAVER (FFE) & ABOVETAPERED INSULATION &WATERPROOF MEMBRANE07.22.26 01:39 PM | L:\WFCU_BOZ\BIMCAD\LandArch\WFCU_BOZ_L502-L503.dwgL503IRRIGATIONDETAILS-CHRISTOFANELLICHRISTOFANELLIROSA©| ALL RIGHTS RESERVED®DRAWN BY |REVISIONSREVIEWED BY |DESIGNED BY |PROJ# |BOZEMAN BRANCH WHITEFISH CREDIT UNION2026SITE PLAN SUBMITTAL 04.30.2026WFCU_BOZDEBRA264ANN-LESLIEROSA07.29.2026 CITY COMMENTS #1