Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
010 - C300 - UTILITY PLAN
131110987.1643IHB125C1AFED2GC.1C.27C1C2ss ss ss ss ss ss ssssssssssss ssbpbpbp bpbpbpbpbpbpbpbpbpbpbpbpbp bp bp bp bp bp bp bp bp bp oh oh oh oh oh oh oh oh oh oh ohgasgasga s gasgasgasgasgasgasgasgasgasgasgasgasgasgasgasgasgasbt bt bt bt bt bt bt bt bt bt btbt bt bt bt bt bt bt bt bt bt bt bt bt bt bt bt bt bt bt btWSSEEEE ETTTTTFOFOFOFOTTTTTTTwm wmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwm wmTEEX XSSDstssssssSstDwmwmwmwmELot 3AMinor Subd iv is ion 503CCommon Open Space AMinor Subdivision 503CPublic Right-of-Way DedicationMinor Subdivision 503CKagy BoulevardWidth VariesSouth 19th Avenue Width Varies S 88°36'18" E 191.26' (R1)S 89°52'03" E 191.26' (M)S 28°49'39" E9.81' (C)S 27°33'54" E9.81' (R1)S 00°20'06" W 245.17' (M) S 01°33'21" W 245.27' (R1)S 89°44'45" W 126.63' (M)N 88°56'52" W 126.64' (R1)N 01°03'08" E 44.41' (R1) N 00°12'23" W 44.48' (M)S 89°44'40" W 81.63' (M)N 88°56'52" W 81.67' (R1)S 00°12'31" E20.80' (M)S 01°03'08" W20.83' (R1)S 89°45'28" W 33.87' (C)N 88°56'53" W 34.00' (R1)N 01°03'08" E 179.47' (R1)N 00°12'37" W 179.44' (C)S 88°56'52" E 48.50' (R1)N 89°47'23" E 48.50' (C)N 01°03'08" W 51.97' (R1)N 00°12'37" W 51.97' (C)Lot 2A-1Minor Subdivision 503CArea = 1.262 acres10' Public Utility EasementPer Minor Subdivision 50310' Public Utility Easement Per Minor Subdivision 503 30' Sewer and Water and Access EasementDocument No. 2471376 30' Easement perDocument No. 2471376Easement perDocument No. 2841657Middle Creek Ditch SSBPBP BPWSWSWSWSWSWSWSWS WS WS WS W SFFFFFFFFFF F F F F GA S GAS GAS GAS GAS GASGASHYDFBPPROPOSED BUILDING15,057 SF4921.00 FFEDSTSTDCOC O STSTSUBSURFACESTORMCHAMBERSEXISTING STORM PONDEXISTING 8" WATER MAINEXISTING 8" SEWER MAINEXISTING BURIED POWEREXISTINGELECTRICAL ANDCOMMUNICATIONSTRUCTURES, TYP.EXISTING STREET LIGHT POLE, TYP.PROPOSED BURIED POWER ANDGAS TO BE COORDINATED WITHUTILITY PROVIDERSSANITARY SEWER SERVICECONNECTION AT BUILDING. SEEPLUMBING.INV: 4918.00EXISTING GAS LINEEXISTING OVERHEAD POWEREXISTING BURIED TELECOM LINESEXISTING BURIED POWER1.5" DOMESTIC SERVICE CONNECTIONAT BUILDING. SEE PLUMBING.6" FIRE SERVICE CONNECTION ATBUILDING. SEE FIRE PLANS.INSTALL FIRE SERVICE LINE, SEEDETAIL 4/C402.6" WATER MAIN TAP FOR FIRESERVICE, SEE DETAIL 4/C402.PROPOSED FIRE HYDRANTASSEMBLY, SEE DETAIL 6/402.1.5" WATER MAIN TAP FOR DOMESTICSERVICE, SEE DETAIL 5/C402.6" WATER MAIN TAP FOR FIRESERVICE, SEE DETAIL 4/C402.CONNECT TO EXISTING 4" SANITARYSEWER STUB. CONTRACTOR TO FIELDVERIFY LOCATION AND INVERT PRIORTO THE START OF CONSTRUCTION. INV:4915.43"±EXISTING TELEPHONESTRUCTURES, TYP.EXISTING FIBER OPTICPEDESTAL, TYP.6" 45 DEG BEND WITH THRUSTBLOCK, SEE DETAIL 2/C402.EXISTING FIRE HYDRANTTHRUST BLOCKING FOR WATERMAIN VALVES, SEE DETAIL 3/402.THRUST BLOCKING FOR WATERMAIN VALVES, SEE DETAIL 3/402.INSULATED XING4" SS INV: 4916.04'12" ST INV: 4913.96'EXISTING IRRIGATIONWELL. SEE IRRIGATIONPLANS.FDC1.5" WATER METER11.25' X 6.00' MECHANICAL ROOMGAS SERVICE CONNECTION ATBUILDING. SEE PLUMBING.BURIED POWER CONNECTION ATBUILDING. SEE ELECTRICAL.6" 45 DEG BEND WITH THRUSTBLOCK, SEE DETAIL 2/C402.WS WS F F ©| ALL RIGHTS RESERVED®DRAWN BY |REVISIONSREVIEWED BY |DESIGNED BY |PROJ# |BOZEMAN BRANCH WHITEFISH CREDIT UNION2026SITE PLAN SUBMITTAL 04.30.2026WFCU_BOZ07.29.2026 CITY COMMENTS #17/29/2026 12:50 PM | L:\WFCU_BOZ\BIMCAD\Civil\Sheets\WFCU_BOZ_C300.dwgC300UTILITY PLANMIRANDAMIRANDASCHLEGEL-1C300UTILITY PLAN0102040SCALE: 1" = 20'NORTH1.UNLESS OTHERWISE NOTED, ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THECURRENT MPWSS AND CITY OF BOZEMAN MODIFICATIONS.2.UNLESS OTHERWISE SPECIFIED, WATER LINES 4" AND LARGER SHALL BE CLASS 51 DUCTILIRON PIPE IN CONFORMANCE WITH AWWA C151. ALL SERVICES AND CONNECTIONSSMALLER THAN 4" SHALL BE TYPE K COPPER MEETING AWWA STANDARD C800 ANDCONFORM TO THE CITY OF BOZEMAN STANDARDS.3.THE CONTRACTOR SHALL SUPPLY ALL NECESSARY FITTINGS, COUPLING, AND SPOOL PIECESFOR CONNECTING NEW UTILITIES TO EXISTING UTILITIES. THESE PLANS MAY NOT SHOW ALLREQUIRED COMPONENTS FOR MAKING THE CONNECTIONS.4.THE MINIMUM DEPTH OF BURY TO THE TOP OF PIPE FOR WATER LINES IS 6.5 FT AND AMAXIMUM OF 7.5 FT OF COVER. WHERE AT LEAST 6.5 FT OF COVER CANNOT BE MAINTAINED,INSTALL RIGID INSULATION BOARD ABOVE PIPING AS INDICATED ON PLANS.5.THE CONTRACTOR MUST ENSURE THAT A MINIMUM OF 10 FEET (OUTSIDE PIPE WALL TOOUTSIDE PIPE WALL) OF CLEARANCE IS MAINTAINED ON THE HORIZONTAL PLANE BETWEENALL WATER AND SEWER MAINS. ADDITIONALLY, THE CONTRACTOR MUST ALSO ENSURETHAT 18 INCHES OF VERTICAL CLEARANCE IS MAINTAINED BETWEEN WATER AND SEWERMAINS THAT CROSS. IMMEDIATELY NOTIFY ENGINEER OF CONFLICTS.6.LOCATIONS OF FITTINGS, BENDS, VALVES, AND OTHER APPURTENANCE ARE APPROXIMATE.PROVIDE ADEQUATE SPACING BETWEEN FIXTURES TO MAINTAIN PIPE INTEGRITY. PROVIDEAS BUILT LOCATIONS FOR ALL FIXTURES.7.ANY EXISTING OR NEW VALVES THAT CONTROL THE CITY OF BOZEMAN WATER SUPPLYSHALL BE OPERATED BY CITY PERSONNEL ONLY.8.PRESSURE TEST AND DISINFECT ALL WATER LINES IN ACCORDANCE WITH THE CITY OFBOZEMAN STANDARDS AND ALL OTHER GOVERNING AGENCIES' STANDARDS.9.ALL FITTINGS SHALL BE MECHANICAL JOINT WITH CONCRETE THRUST BLOCKS MEETINGCITY OF BOZEMAN STANDARDS.10.ALL DUCTILE IRON FITTINGS TO BE WRAPPED IN POLYWRAP.1.UNLESS OTHERWISE NOTED, ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THECURRENT MPWSS AND CITY OF BOZEMAN MODIFICATIONS.2.UNLESS OTHERWISE SPECIFIED, SANITARY SEWER PIPE SHALL BE PVC IN CONFORMANCEWITH ASTM D-3034, SDR 26. ALL SERVICES AND CONNECTIONS SHALL CONFORM TO THECITY OF BOZEMAN STANDARDS.3.ALL PIPES SHALL BE BEDDED WITH TYPE 1 BEDDING PER CURRENT MPWSS & ANYAPPLICABLE CITY OF BOZEMAN MODIFICATIONS.4.THE CONTRACTOR SHALL FLUSH AND CLEAN ALL SEWER PIPE AND MANHOLES.5.CONTRACTOR SHALL FIELD VERIFY LINE AND GRADE OF ANY EXISTING AND PROPOSEDUTILITY.DRY UTILITY NOTES1.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE INSTALLATION OF ALL "DRY"UTILITIES (ELECTRIC, GAS, TELEPHONE) WITH SERVICE PROVIDERS.2.REFER TO ELECTRICAL PLANS FOR ADDITIONAL CONDUIT AND SITE LIGHTINGREQUIREMENTS.3.REFER TO LANDSCAPE PLANS FOR IRRIGATION CONDUIT.4.THE CONTRACTOR IS RESPONSIBLE TO CALL 1-800-424-5555 (OR 811) AT LEAST 2 WORKINGDAYS PRIOR TO ANY EARTH DISTURBING ACTIVITIES OR UTILITY EXCAVATIONS.11.256.006" FIRE RISER1.5" DOMESTIC WATER RISER2C300WATER UTILITY ROOM 0124SCALE: 1" = 2'NORTH