HomeMy WebLinkAbout039_L600 IRRIGATION GUIDANCE AND WATER USE ESTIMATES47154710472047054700469546904725473047354740474547404745475047554760476547704710470547004710471547054700WWESWESWESWESWESWESWESWESWES
WES
WES
WES
GEY GEYGEYLUTLUTLUTLUTLUTLUTLUTLUTLUTGEYGEYGEYGEYGEYGEYLUTLUTGEYGEYGEYGEYGEYGEYGEYGEYGEYLUTLUTLUTLUTLUTLUTLUTLUTLUTGEYGEYGEY
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT LUT
GEY
GEY
GEY
GEY
GEY GEY
LUT
LUT
LUT
GEY GEY
GEYLUT
LUT
LUT
LUT LUT
LUT
LUT
LUT
LUT LUT
LUT
LUT LUT
LUT
LUT LUT
LUT
LUT LUT
LUT
LUT
LUT
LUTLUT
LUT
LUT
LUT
LUT
LUT
LUT
LUTLUTLUTLUTLUTLUTGEYGEYGEYGEYGEYGEYGEYGEYGEYGEYGEYGEYGEY
GEY GEY
GEYGEY
GEY
GEYGEYGEYGEY
GEY
GEY
GEY
GEY
GEY
GEY
GEY
GEY
GEY
GEY
GEY
GEY
GEY
GEYGEY
GEYGEY
GEYGEYGEY
GEY
GEY
GEY
GEY
GEYGEY
GEYGEYWESWESWESWESWESWES
WESWES WESWES
WESWESWESWESWESWESREDRED6'8'10'8'10'8'8'10'8'AMU REDREDAMU AMU AMUREDRED REDREDRED
IRRIGATIONTYPEWATER USE ESTIMATE SCHEDULETOTALAREA / QTYANNUALET RATETOTALANNUAL H2OTOTAL ANNUAL H2O REQUIRED: 67,851 GALTOTAL ACRE FEET PER YEAR: .21 ACRE FEETH.E. TREEBUBBLER58 TREES16.5 GAL /WEEK17,226 GALTEMP H.E.TREEBUBBLER125 TREES16.5 GAL /WEEK37,125 GALTEMP H.E.SHRUBBUBBLER375SHRUBS16.5 GAL /WEEK50,625 GALNOTE:1.ALL WATERCOURSE PLANTINGS WILL HAVEDEDICATED DRIP. AFTER ESTABLISHMENT,(APPROX. 3 YEARS) THESE DRIP ZONES WILL BETURNED OFF.CONCEPTUAL IRRIGATION NOTES:1.ALL SECTIONS OF MAINLINE CROSSING UNDER CONCRETE,ROADS, OR OTHER LARGE HARDSCAPE SURFACES TO BE INSCH. 40 PVC SLEEVES.1.1.SLEEVES TO BE DOUBLE THE DIAMETER OF PROPOSEDMAINLINE.1.2.LATERAL LINE SLEEVES TO BE SCH. 40 PVC AT LEASTDOUBLE THE DIAMETER OF THE LATERAL LINE SIZEPROPOSED.2.ALL SYSTEMS TO BE ON A LOOPED MAINLINE WHEREPOSSIBLE, REFER TO CONCEPTUAL IRRIGATION MAINLINELAYOUT.3.ALL SYSTEMS WILL BE 2 WIRE DECODER TYPE SYSTEMS.4.ALL INFORMATION SHOWN ON CONCEPTUAL DRAWINGS TO BEVERIFIED BY IRRIGATION DESIGNER, AND CONTRACTOR.COORDINATION WITH GENERAL CONTRACTOR IS NECESSARYBEFORE CONSTRUCTION BEGINS TO ENSURE PROPERLOCATION OF SLEEVES, ELECTRICAL CONNECTIONS, ANDWATER SOURCE CONNECTIONS.5.ALL IRRIGATION COMPONENTS TO BE HIGH EFFICIENCY,HEADS, NOZZLES, DRIP, VALVES, AND FITTINGS.GENERAL IRRIGATION NOTES AND SPECIFICATIONS1.THESE PLANS PROVIDE GENERAL ANTICIPATED WATERDEMAND AND TYPE OF IRRIGATION FOR THE PARK, WHICH ISIRRIGATED BY A WELL.2.ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER3.IRRIGATION MAIN LINE TO BE SCH. 40 PVC SOLVENT WELDEDPVC IN CONTINUOUS LOOP, SIZE OF LINE DEPENDENT ONWATER DEMAND AS DETERMINED BY LANDSCAPECONTRACTOR. LATERAL LINES TO BE 1" SCH 40 SOLVENTWELDED PVC; DEPENDENT ON PRESSURES AND GALLONS PERMINUTE AT DISCRETION OF LANDSCAPE CONTRACTOR BASEDON PROFESSIONAL EXPERIENCE AND OPINION UPON DESIGNAND INSTALLATION OF THE SYSTEM.4.ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERSEVENLY DISTRIBUTED AROUND BASE OF TREE WITH FOUR (4)EVENLY SPACED 1 GPH BUBBLER EMITTERS.5.TREES AND SHRUBS PLACED WITHIN PLANTING BEDS MAYUTILIZE DRIP IRRIGATION ADJUSTED PER INDIVIDUAL PLANTREQUIREMENTS.6.ALL SHRUBS OUTSIDE OF DEDICATED PLANTING BEDS TO HAVEDEDICATED BUBBLERS EVENLY DISTRIBUTED AROUND BASE,WITH TWO (2) EVENLY SPACED 1 GPH EMITTER.7.BUBBLERS TO TREES MAY BE OMITTED WHERE OVERHEADIRRIGATION WILL PROVIDE ADEQUATE WATER.8.ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BEIRRIGATED WITH DEDICATED DRIP TUBING W/ EMITTERSADJUSTED PER INDIVIDUAL PLANT REQUIREMENTS.9.LAWN AND SEED AREAS TO BE IRRIGATED WITH SPRAY ORROTOR OVERHEAD IRRIGATION AS INDICATED PER PLAN.9.1.ALL SPRAY OR ROTOR OVERHEAD IRRIGATION HEADSWILL BE INSTALLED AND ADJUSTED PROPERLY TOMINIMIZE WATER OVER THROW ONTO PAVEMENT.9.2.ALL SPRAY OR ROTOR OVERHEAD IRRIGATION TO UTILIZEWATER EFFICIENT NOZZLES (MULTI-SPRAY,MULTI-TRAJECTORY, OR ROTATING SPRAY).10.ALL HEADS MUST ACHIEVE HEAD-TO-HEAD COVERAGE FORSOD AREAS.11.SYSTEM SHALL UTILIZE WEATHER / MOISTURE MONITOR.12.BACKFLOW ASSEMBLY AND BLOWOUT ASSEMBLY SHALL BELOCATED IN APPROVED EXTERNAL GRADEBOX, AND IS THERESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TOCOORDINATE INSTALLATION PER LOCAL CODES ANDORDINANCES, WITH ARCHITECTURE AND WITH ALL OTHERTRADES.13.POWER SOURCE FOR IRRIGATION CONTROLLER TO BECOORDINATED WITH ELECTRICAL ENGINEERING ANDELECTRICAL CONTRACTOR BY LANDSCAPE CONTRACTOR.14.DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUSOBSTRUCTIONS OR GRADE CHANGES ARE PRESENT.15.ALL INFORMATION TO BE FIELD VERIFIED BY CONTRACTORPRIOR TO INSTALLATION.16.THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT'AS-BUILT' IRRIGATION PLAN ON SITE AT ALL TIMES.17.ALL SPRAY AND ROTOR HEADS WITHIN SOD LAWN AREAS TOPROVIDE A PRECIPITATION RATE OF 0.4-0.8"/sqft.SYMBOLSIZEDESCRIPTIONIRRIGATION LEGENDBACKFLOW PREVENTER1"CONNECTION POINTIRRIGATION SLEEVE, 4" MIN. SCH 40 PVC*NOTES:-IRRIGATION LAYOUT TO BE DETERMINED IN FIELD BYIRRIGATION CONTRACTOR-FINAL IRRIGATION AS-BUILT MAPS TO BE PROVIDED TO THECITY OF BOZEMAN PARKS DIVISION-WELLS TO BE INSTALLED AT DISTANCE FROM SANITARYSEWER LINES PER CURRENT REGULATIONS-IRRIGATION SYSTEM TO BE HUNTER 2-WIRESYSTEM/DECODERS WITH HUNTER CONTROLLER ONMETAL PEDESTAL MOUNT, UNLESS OTHERWISE APPROVEDBY THE CITY'S PARKS OPS SUPTN/AN/AWPROPOSED WELL*FINAL LOCATION TBD BY CIVILN/ABFCPFINISH GRADESCH. 40 PVC SLEEVE - 4" MIN. OR 2X THE O.D.OF THE IRRIGATION PIPINGWRAP 12 GAUGE WIRE AROUND EACH ENDOF THE SLEEVE AND EXTEND TO THESURFACEWASHED AND GRADED MORTARSAND BACKFILL IN ROCKY SOIL.PAVEMENT EDGENOTE:1.CAP SLEEVES UNTIL USE.2.4" MIN. HORIZONTAL SEPARATION REQUIRED BETWEEN SLEEVESIN THE SAME TRENCH.3.IRRIGATION PIPE AND CONTROL WIRES SHALL BE SLEEVEDSEPARATELY.4.SOIL AROUND SLEEVE BACKFILLED AND COMPACTED TO THESAME DENSITY AS THE SURROUNDING SOIL.DEPTH PER TRENCHING DETAIL2L600NTSIrrigation Sleeve120600240N1L6001"=120'-0"Irrigation Guidance and Water Use EstimatesIRRIGATIONGUIDANCE ANDWATER USEESTIMATESL 600design5la.com406.587.4873dateissue04/29/26SITE PLANdrawn by:checked by:filename:z:\bikefill\autocad\01_sheets\bikefill_l600_d5_irrigation.dwg
Bikefill Community
Bike Park
Bozeman, Montana
AV/GO TMS
107/01/26SITE PLAN RC107/20/26SPR2IRRIGATION WELL. FINALLOCATION TBD. SEE CIVILALSO.ALL WATERCOURSE PLANTINGS TORECEIVE TEMPORARY DRIP IRRIGATION.ALL IRRIGATION INFRASTRUCTURE WITHINSETBACK MUST BE ABOVE GROUND.ALL WATERCOURSE PLANTINGS TORECEIVE TEMPORARY DRIP IRRIGATION.ALL IRRIGATION INFRASTRUCTURE WITHINSETBACK MUST BE ABOVE GROUND.PARKING LOT IRRIGATION BYOTHERSALL SITE TREES OUTSIDE OFWATERCOURSE SETBACK TORECEIVE PERMANENT DRIPIRRIGATION.111111