HomeMy WebLinkAbout029_L4.1_IRRIGATION DETAILSPRELIMINARY - FOR REVIEWFILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION----IRRIGATION DETAILSBIKEFILL COMMUNITY BIKE PARKPATH AND ON-SITE IMPROVEMENTSBOZEMAN, MTL4.1 RPE22147.01_IRR_PROD.DWGDME04/29/2026SITE PLAN SUBMITTAL--------------22147.01POINT OF CONNECTION - HOT BOX
N.T.S.
FROM WATER
SOURCE
TO IRRIGATION
SYSTEM
GROUND LEVEL
BACKFLOW PREVENTOR
BLOWOUT TEE WITH CAP
COPPER PIPE
MAIN LINE (PVC PIPE)
COPPER PIPE 1'-6" MINHOT BOX
CONCRETE SLAB
NOTE:
1.INSTALL A HOT BOX WITH CONCRETE SLAB, POWDER COATED
2.INSTALL ALL COMPONENTS PER NATIONAL PLUMBING CODE
3.COORDINATE WITH OTHER TRADES AND OWNER/OWNERS REP FOR
EXACT LOCATION
1 TRENCHING DETAILS
N.T.S.
1'-6"
PLANS
SECTIONS
DIRECT BURY PLAN
DIRECT BURY SECTION
TAPE & BUNDLE ALL WIRING AT 10'-0"
INTERVALS. USE 6" WIDE MARKING TAPE 6"
ABOVE ALL DIRECT BURIAL WIRING.
ALL SPLICES SHALL BE MADE IN VALVE BOXES
AND LOCATED ON AS-BUILT PLANS (ALL 120 V).
WIRING SHALL BE IN CONDUIT WITH MARKER
TAPE AS ABOVE.
ALL WIRING UNDER PAVEMENT & THROUGH
SLEEVES SHALL BE IN CONDUIT. TIE A LOOSE
1'-8" LOOP IN WIRING AT ALL CHANGES IN
DIRECTION GREATER THAN 30 DEGREES. UNTIE
ALL LOOPS AFTER MAKING CONNECTIONS.
1'-6"
CONDUIT SECTION
CONDUIT PLAN
2'-0" 3'-0" 2'-0" 3'-0"
LATERAL PIPE IN
TRENCH SNAKE ALL
FINISHED GRADE
MARKING TAPE
LOOP
TIES
FINISHED GRADE
LATERAL
MAIN LINE
BEDDING
LOW VOLTAGE WIRE OR 120V WIRE IN CONDUIT
LATERAL
2 ELECTRIC CONTROL VALVE
N.T.S.1'-0"NOTES:
1.USE TEFLON TAPE FOR ALL THREADED PIPE CONNECTIONS.
2.ALL WIRES TO BE INSTALLED AS PER LOCAL CODES. NO
''IN-LINE'' WIRE SPLICES WILL BE ALLOWED.2'-0"PVC MALE ADAPTOR & LATERAL LINE
FINISHED GRADE
1'-0" STANDARD VALVE BOX
DRAIN GRAVEL
1 CU. FOOT
SCH.80 UNION
CENTER VALVE IN BOX
SCH.80 NIPPLE
SCH.40 PVC SXT 90\
CLASS 200 PVC PIPE
CONTROL WIRES
SCH.40 PVC TEE OR 90
ANGLE TO DIRECT
LATERAL IN TRENCH
SUCH THAT PIPE IS NOT
CURVED OR OTHERWISE
STRESSED.DOUBLE
VALVE BOXES
BOLTED BACK
TO BACK
3 POP-UP SPRAY HEAD
N.T.S.
MIN 4"
NOTES:
1.NIPPLE AND STREET ELL DIAMETERS SHALL EQUAL INLET
SIZE SPRAY BODY.
FINISH GRADE
POP-UP SPRINKLER BODY.
SEE SCHEDULE FOR TYPE.
(3)MARLEX STREET ELLS
FLEXIBLE PIPE
SCH.40 P.V.C. TEE
WALK/CURB
4
1" DRIP ZONE KIT
N.T.S.
FINISHED GRADE
PVC SCH 40 ELL
PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)
30" LINEAR LENGTH OF WIRE, COILED
WATERPROOF CONNECTION: SPLICE-1 (1 OF 2)
ID TAG
VALVE BOX WITH COVER
PVC SCH 40 FEMALE ADAPTER
LATERAL PIPE
BRICK (1 OF 4)
3" MINIMUM DEPTH OF 3/4" PEA
GRAVEL
CONTROL ZONE KIT: (INCLUDES 1" VALVE,
BACK FLUSH PRESSURE REGULATING
FILTER, DUCK BILL BOOT).
PVC SCH 80 NIPPLE (2-INCH LENGTH,
HIDDEN) AND PVC SCH 40 ELL
PVC SCH 40 TEE OR ELL
PVC MAINLINE3"5
NOTES:
1.AIR RELIEF VALVE (PLD-AVR) INSTALLED IN VALVE
BOX AT OPTIMAL HIGHEST POINT FROM CONTROL
ZONE KIT. MULTIPLE AIR RELIEF VALVES MAY BE
NEEDED TO ACCOMMODATE DIFFERENCES IN
GRADE.
2.ECO-INDICATOR TO BE INSTALLED AT OPTIMAL
FURTHEST POINT FROM CONTROL ZONE KIT IN
CLEAR VIEW WHEN POPPED UP.
3.FLUSH POINT TO BE INSTALLED AT OPTIMAL
FURTHEST POINT FROM CONTROL ZONE KIT TO
ALLOW FOR MAXIMUM DEBRIS FLUSH IN SYSTEM.
LANDSCAPE DRIP LINE
TREE TRUNK
PDL OR PDL-LOC FITTING TYP.
PVC TO DRIP LINE TUBING CONNECTION
(PDL OR PDL-LOC FITTINGS) TYP.
PVC LATERAL LINE
TREE RING DRIPLINE
N.T.S.6
p:\22147_01_bikefill_bike_park_design\CADD_C3D\production_dwg\22147.01_IRR_PROD.dwg, 4.1 DETAILS, 5/1/2026 11:23:03 AM, amartoncik, 1:1