Loading...
HomeMy WebLinkAbout2026-08-07_BPL Childrens Room_ADD1 510 Marquette Avenue South, Suite 200 Minneapolis, MN 55402 | 612.375.0336 msrdesign.com Introduction This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated 6/29/2026 . Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject Bidder to disqualification. Reference made below to Specifications and /or Drawings shall be used as a guide only. When Specification Sections or Drawings are issued, changes made in Specification or on Drawings will take precedence over narrative explanation below. Contractor shall determine for themselves the work affected b y Addendum items. This Addendum consists of two p ages, plus attachments listed below. It is assumed that specification sections and drawings are not attached unless specifically indicated as Attached. Attachments Specifications 00 21 13c Bid Bond 01 60 10.01 Substitution Request Form 01 57 19 Temporary Environmental Controls Detail Drawings N/A Drawings ED201 – LEVEL ONE LIGHTING DEMOLITION PLAN ED101 – LEVEL ONE POWER AND SIGNAL PLAN TD101 – LEVEL ONE – ICT DEMO PLAN T100 – LEVEL ONE - ICT Special Attachments 2026 -07-29_NorthernRockies_Lighting_MSR26.08.04_BZN26.08.05 2026 -08 -04_MH_Companies_Lighting_MSR26.08.04_BZN26.08.05 2026 -08 -05_Greenheck Substitution_MM26.08.05_BZN26.08.06 2026 -08 -05_TLA Light Substitutions_MSR26.08.05_BZN26.08.05 FloAire_Exhaust_Fan_Prior_Approval_MSR26.08.04_BZN26.08.05 If attachments are not as stipulated above, please notify MSR Design promptly. Changes to Project Manual Modifications to Introductory Information a. N/A Modifications to Bidding Information 1. 00 21 13c Bid Bond : Replace Section in full a. Notes have been revised. Addendum NO. 001 Date 8/7/2026 Project Na me Bozeman Public Library Children’s Room Remodel Project Number 2025021BCR Project Phase Bidding Project Location 626 E Main St, Bozeman, MT 59715 Issue Date 8/7/2026 Bid Date 8/13/2026 To Bidding Contractors From MSR Design 510 Marquette Avenue South, Suite 200 Minneapolis, MN 55402 Bozeman Public Library Children’s Room Remodel Section 000901 Addendum NO: 001 2025021BCR Bid Documents 2 b. Note 1 has been added clarifying requirements for Bond Amount and procedures. 2. 01 60 10.01 Substitution Request Form : Replace Section in full a. Complete form for use by Contractors has been added to the Project Manual Modifications to Specifications 1. 01 57 19 Temporary Environmental Controls : Replace section in full a. Deleted Sections: i. 1.06, D – H ii. 3.03 iii. 3.04 iv. 3.05 Changes to Drawings 1. ED201 - LEVEL ONE LIGHTING DEMOLITION PLAN : Replace sheet in full a. 1/ED201: Updated to show temporary removal of paging equipment in RM118 2. E101 - LEVEL ONE POWER AND SIGNAL PLAN: Replace sheet in full a. 1/E101: Updated to show reinstallation of paging equipment in RM118 at new location 3. TD101 - LEVEL ONE – ICT DEMO PLAN: Replace sheet in full a. 1/TD101: Updated to show temporary removal of paging equipment in RM118 4. T100 - LEVEL ONE - ICT: Replace sheet in full a. 1/T100: Updated to show reinstallation of paging equipment in RM118 at new location End of Addendum 001 GENERAL ELECTRICAL DEMO NOTES A. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF ANY EXISTING CONDUIT OR FEEDER CIRCUITS THAT ARE INTENDED TO REMAIN, THAT ARE SAW-CUT, OR OTHERWISE DAMAGED, AS PART OF THE DEMOLITION PROCESS. PROVISION FOR THIS WORK SHALL INCLUDE, BUT IS NOT LIMITED TO: ALL NECESSARY CONDUIT AND CONDUCTORS, MOUNTING ACCESSORIES AND LABOR, TO RESTORE SYSTEM TO INTENDED FUNCTION. B. ELECTRICAL DRAWINGS SHOWING EXISTING BUILDING CONDITIONS, SUCH AS DEMOLITION DRAWINGS, EXISTING PANEL SCHEDULES, ETC. ARE BASED ON RECORD DRAWINGS AND SITE VISITS. IF ACTUAL EXISTING CONDITIONS DIFFER FROM THOSE SHOWN ON DRAWINGS, PLEASE NOTIFY ENGINEER. C. ELECTRICAL DEVICES SHOWN IN GREY ARE EXISTING TO REMAIN. ELECTRICAL DEVICES SHOWN IN BLACK/DASHED WITH A '(D)' ARE TO BE DEMOLISHED AND WITH A '(R)' ARE TO BE RELOCATED, UNO. FOR DEVICES NOTED TO BE DEMOLISHED, ELECTRICAL CONTRACTOR SHALL REMOVE IN ENTIRETY, INCLUDING ASSOCIATED BRANCH CIRCUIT BACK TO SOURCE OR NEAREST UPSTREAM LIVE DEVICE. D. PATCH/REPAIR ALL HOLES IN FLOOR, WALLS, AND DECK RESULTING FROM DEMOLITION WORK AS REQUIRED. 1 2 3 4 5 6 7 7.9 8 9 K J I.5 I H G.9 G F E D C B A (R)(R) (D)(D)(D)(D) (D)(D)(D)(D) (D)(D) (D)(D) (R)(R) (D) CHILDRENS ROOM 116 COLLECTION 116B STORAGE / IT 120 (D)(D) (D)(D) 1 1 1 1 1/8" = 1'-0"ED201 1 LEVEL ONE LIGHTING DEMOLITION PLAN 1. SALVAGE EXISTING LUMINAIRE FOR RE-USE AND RE-LOCATION. KEY NOTES:# No. 60006 PE RYAN P. MARONEY M O NTANA LICENS E DPRO F ESSIONA L E N G IN EERDrawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. Drawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. ISSUE / REVISION Signature Print Name Date License No DateMark Description 510 Marquette Avenue South, Suite 200 Minneapolis, MN 55402 | 612.375.0336 2026.06.29 Ryan P. Maroney 60006 2025.12.05 Scope Concept Pricing 2026.04.24 Design Pricing 8/4/2026 1:33:06 PM Autodesk Docs://2025021 Bozeman Childrens Room Renovation/5964.004 - BPL Childrens Room_ MEP_R26.rvtAddendum 12026.08.07 ED201 LEVEL ONE LIGHTING DEMOLITION PLAN Bidding and Permit 2026.06.29 Bidding and PermitProject No: 2025021Bozeman Public LibraryChildren's Room Remodel626 E Main St.Bozeman, MT 59715Architecture and Interiors 2880 Technology Blvd W, Bozeman, MT, 59718 | 406.587.0721 Mechanical, Electrical, Plumbing, IT M M S S S FS SFFD C SM ADAADAADAADAD C M D D E D J TVTV J F SSD F SADAADAADAM ADA J J E M S S SS S M M M J J S S TV SD D J H F C C C F C C JC S S S F S F D J D J D D 1 2 3 4 5 6 7 7.9 8 9 K J I.5 I H G.9 G F E D C B A GFI GFI GFI DRINKING FOUNTAIN LG EF-8 FAMILY RESTROOM 115 FAMILY RESTROOM 114A NOOK 116D STAFF WORK 118 OFFICE 117 COLLECTION 116B ACTIVE PLAY 116A STEAM ZONE 116C THEME ROOM 113 WELLNESS ROOM 114 1 1 1 1 1 3 DISHWASHER 2 2 LG-36 LG-36 LG-38 LG-38 LG-40 LG-42 LG-47 LG-49 3 LG-51,53 LG-44 GFI3 LG-38 3 LG-43 3 3 2 4 3 3 5 (EX)LB 3 1 3 3 3 3333 48" LG-46 1 LG-40 LG-47 5 LG-48 LG-48 LG-48 1 LG-42 PRINTERLG-50LG-48LG-33 5 1 LG-52 1 LG-52 1 1 48" 48" 48" (EX) 6 6 3 GENERAL ELECTRICAL NOTES A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. C. LOW VOLTAGE CABLES (LIGHTING CONTROLS) ABOVE ACCESSIBLE CEILINGS SHALL BE SUPPORTED USING J-HOOKS AT INTERVALS NOT TO EXCEED 48" OC, UNO. D. ELECTRICAL DEVICES SHOWN IN GREY ARE EXISTING TO REMAIN. ELECTRICAL DEVICES SHOWN IN BLACK ARE NEW, UNLESS NOTED OTHERWISE. E. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONNECTIONS TO POWERED MILLWORK AND CASEWORK ACCESSORIES, COORDINATE WITH MILLWORK DRAWINGS. F. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CONNECTIONS TO POWERED FURNITURE AND ACCESSORIES, COORDINATE WITH FURNITURE PLANS AND MANUFACTURERS REQUIREMENTS. G. WHERE NEW ELECTRICAL DEVICES ARE SHOWN ON EXISTING WALLS, ELECTRICAL CONTRACTOR SHALL FISH MC CABLE CONCEALED THROUGH EXISTING WALL AND PROVIDE FLUSH DEVICES. COORDINATE WITH GENERAL CONTRACTOR FOR ANY REQIURED CUTTING AND PATCHING. H. REFER TO ARCHITECTURAL CEILING PLANS FOR EXACT LOCATIONS OF CEILING MOUNTED DEVICES IN GYPSUM BOARD AND WOOD CEILINGS. I. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT LOCATIONS OF WALL MOUNTED DEVICES. J. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND ORIENTATION OF LUMINAIRES AND DEVICES PRIOR TO INSTALLATION. No. 60006 PE RYAN P. MARONEY M O NTANA LICENS E DPRO F ESSIONA L E N G IN EERDrawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. Drawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. ISSUE / REVISION Signature Print Name Date License No DateMark Description 510 Marquette Avenue South, Suite 200 Minneapolis, MN 55402 | 612.375.0336 2026.06.29 Ryan P. Maroney 60006 2025.12.05 Scope Concept Pricing 2026.04.24 Design Pricing 8/4/2026 1:33:07 PM Autodesk Docs://2025021 Bozeman Childrens Room Renovation/5964.004 - BPL Childrens Room_ MEP_R26.rvtAddendum 12026.08.07 E101 LEVEL ONE POWER AND SIGNAL PLAN Bidding and Permit 2026.06.29 Bidding and PermitProject No: 2025021Bozeman Public LibraryChildren's Room Remodel626 E Main St.Bozeman, MT 59715Architecture and Interiors 2880 Technology Blvd W, Bozeman, MT, 59718 | 406.587.0721 Mechanical, Electrical, Plumbing, IT 1/8" = 1'-0"E101 1 LEVEL ONE POWER AND SIGNAL PLAN KEY NOTES:# 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF FLOOR BOXES PRIOR TO ROUGH-IN. 2. RELOCATE SALVAGED FIRE ALARM NOTIFICATION DEVICE HERE. EXTEND EXISTING FIRE ALARM CIRCUIT AS REQUIRED. 3. POWER NEW RECEPTACLE FROM EXISTING 20A 120V CIRCUIT SERVING EXISTING RECEPTACLE(S) IN ROOM, UNO. EXTEND EXISTING BRANCH CIRCUIT AS REQUIRED. 4. MOUNT RECEPTACLE UNDER SINK TO SERVE DISHWASHER. 5. SEE DETAIL ON SHEET E002 FOR DROP RECEPTACLE. REFER TO ARCHITECTURAL DRAWING FOR EXACT LOCATION PRIOR TO ROUGH-IN. 6. UPDATE EXISTING PANEL SCHEDULE DIRECTORY UPON COMPLETION OF WORK TO REFLECT AS-BUILT CIRCUITRY. REF-21 2 3 4 5 6 7 7.9 8 9 A B C D E F G G.9 H I I.5 J K (D) (D) (D) (D) (D) (D) (D) (D) (D) (D) (D) (D) (D) (D) (D)(D) (D) WAOS IN EXISTING WIREMOLD. SEE ELECTRICAL SHEETS FOR ADDITIONAL INFO. EXISTING OVERHEAD PAGING SYSTEM MOUNTED ON WALL. DEMO AND SALVAGE EQUIPMENT, CONDUITS AND BACKBOXES FOR REUSE. RELOCATE ALL ASSOCIATED WALL MOUNTED EQUIPMENT TO WALL SHOWN ON SHEET T100. GENERAL ICT DEMO NOTES A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER. B. CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. C. ALL WALL REGIONS SHOWN DASHED ARE EXISTING, TO BE DEMOLISHED, OR IN SOME CASES ARE EXISTING DOORWAYS TO BE WALLED IN. CONTRACTOR SHALL FIELD VERIFY AFFECTED ICT SYSTEMS PRIOR TO BID, AND DURING CONSTRUCTION. D. DASHED WALLS, EQUIPMENT, AND DEVICES SHOWN BLACK, OR BLACK AND DASHED, IN HATCHED GRID REGION ARE EXISTING FOR DEMOLITION, AND ITEMS IN SOLID GREY ARE EXISTING TO REMAIN, UNO. E. THE DEVICE LAYOUT IN THESE DEMOLITION PLANS DOES NOT REFLECT ALL DEVICES OR CONDITIONS THE CONTRACTOR MAY FIND IN THE FIELD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLTION OF DEVICES NOT SHOWN IN THE ICT DEMOLITION DRAWINGS. THE CONTRACTOR SHALL FIELD-VERIFY EXISTING CONDITIONS PRIOR TO BID. F. THE CONTRACTOR SHALL REMOVE ALL CABLING ASSOCIATED WITH DEMOED DEVICES (LABELED (D)) FROM SOURCE TO DESTINATION. G. ALL WORK AREA OUTLETS, CABLING, CAMERAS, KEYPADS, CARD READERS, RACKS, CABINETS, SPEAKERS, AND ACTIVE EQUIPMENT IN HATCHED GRID REGION SHALL BE RETURNED TO OWNER, UNO. IS S EFORP LANO E N G INEERO NTM ANA LICENS E D PAUL HEFFERNAN No. 91429 PE Drawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. Drawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. ISSUE / REVISION Signature Print Name Date License No DateMark Description 510 Marquette Avenue South, Suite 200 Minneapolis, MN 55402 | 612.375.0336 2026.06.29 91429 Paul Heffernan 8/6/2026 3:07:57 PM Autodesk Docs://2025021 Bozeman Childrens Room Renovation/5964.004 - BPL Childrens Room_ICT_R26.rvtTD101 LEVEL ONE - ICT DEMO PLAN Bidding and Permit 2025.12.05 Scope Concept Pricing 2026.06.29 Bidding and Permit 2026.08.07 Addendum 1 2026.04.24 Design PricingProject No: 2025021Bozeman Public LibraryChildren's Room Remodel626 E Main St.Bozeman, MT 59715Architecture and Interiors 2880 Technology Blvd W | Bozeman, MT, 59718 | 406.587.0721 Mechanical, Electrical, Plumbing, ICT 1/8" = 1'-0"TD101 1 LEVEL ONE ICT DEMOLITION PLAN REF-2W/D DW1 2 3 4 5 6 7 7.9 8 9 A B C D E F G G.9 H I I.5 J K 2 22 2 2 2 2 T201 1 Sim 1 1 STAFF WORK 118 STORAGE / IT 120CHILDRENS ROOM 116 ACTIVE PLAY 116A THEME ROOM 113 WELLNESS ROOM 114 FAMILY RESTROOM 114A FAMILY RESTROOM 115 NOOK 116D 2 2 3 2 FOR WIRELESS ACCESS POINT FOR WIRELESS ACCESS POINT 2 2 2 1 2 4 2 1 2 1 2 1 RELOCATE ALL DEMO'D AND SALVAGED OVERHEAD PAGING EQUIPMENT TO THIS LOCATION. EXTEND CABLING AS REQUIRED TO MAINTAIN SYSTEM FUNCTIONALITY. GENERAL ICT NOTES A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. B. CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. C. ALL SIZING, PLACEMENT, AND QUANTITIES FOR CONDUITS, CONDUIT SLEEVES, CABLE TRAY, AND LADDER RACK CALLED OUT ON STRUCTURED CABLING PLANS AND/OR ENLARGED VIEWS. D. ALL CONDUIT ENDS SHALL BE FURNISHED WITH PLASTIC BUSHINGS FOR CABLE PROTECTION. E. PROVIDE PULL STRINGS FOR ALL CONDUITS INSTALLED GREATER THAN 10'. F. PROVIDE SECURITY LOOP FOR ALL NEW CABLING IN STORAGE/IT 120. SECURITY LOOP SHALL BE LONG ENOUGH TO REACH FURTHEST CORNER OF THE ROOM PLUS AN ADDITIONAL 10'. IS S EFORP LANO E N G INEERO NTM ANA LICENS E D PAUL HEFFERNAN No. 91429 PE Drawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. Drawing 2021 Copyright Meyer, Scherer & Rockcastle, Ltd. ISSUE / REVISION Signature Print Name Date License No DateMark Description 510 Marquette Avenue South, Suite 200 Minneapolis, MN 55402 | 612.375.0336 2026.06.29 91429 Paul Heffernan 8/6/2026 3:07:58 PM Autodesk Docs://2025021 Bozeman Childrens Room Renovation/5964.004 - BPL Childrens Room_ICT_R26.rvtT100 LEVEL ONE - ICT Bidding and Permit 2025.12.05 Scope Concept Pricing 2026.06.29 Bidding and Permit 2026.08.07 Addendum 1 2026.04.24 Design PricingProject No: 2025021Bozeman Public LibraryChildren's Room Remodel626 E Main St.Bozeman, MT 59715Architecture and Interiors 2880 Technology Blvd W | Bozeman, MT, 59718 | 406.587.0721 Mechanical, Electrical, Plumbing, ICT 1/8" = 1'-0"T100 1 LEVEL ONE ICT PLAN 1 RUN CABLING FOR FLOOR BOX THROUGH CRAWL SPACE BACK TO STORAGE/IT 120. 2 RUN 2" EMT CONDUIT SLEEVE BETWEEN SECTIONS OF ACCESSIBLE CEILING SPACE. 3 RUN 3" EMT CONDUIT SLEEVE BETWEEN SECTIONS OF ACCESSIBLE CEILING SPACE. 4 MOUNT WORK AREA OUTLET ABOVE COUNTER, MATCH ADJACENT ELECTRICAL RECEPTACLE HEIGHT. KEY NOTES:# Bozeman Public Library Children’s Room and Teen Corner Remodel EJCDC C-430 (Penal Sum Form) Bozeman, MT 59715 BID BOND MSR Design #2025021BCR Page 1 of 2 BID BOND Any singular reference to Bidder, Surety, Owner or other party shall be considered plural where applicable. BIDDER (Name and Address): SURETY (Name and Address of Principal Place of Business): OWNER (Name and Address): BID Bid Due Date: Description: (Project Name and Include Location): BOND Bond Number: Date (Not earlier than Bid due date): Penal sum $ (Words) (Figures) Surety and Bidder, intending to be legally bound hereby, subject to the terms set forth below, do each cause this Bid Bond to be duly executed by an authorized officer, agent, or representative. BIDDER SURETY (Seal) (Seal) Bidder’s Name and Corporate Seal Surety’s Name and Corporate Seal By: By: Signature Signature (Attach Power of Attorney) Print Name Print Name Title Title Attest: Attest: Signature Signature Title Title Note: Above addresses are to be used for giving any required notice. Provide execution by any additional parties, such as joint venturers, if necessary. 1. Provide a Bid Bond of a sum no less than ten (10) percent of the Bid Amount on AIA A310 Bid Bond Form, or standard surety company form, or a certified bank check made payable to the Owner. Check may be either a cashier's check, a check certified by a bank in Montana or a bank chartered under the laws of the United States, or a certified share draft on a credit union in the State in which the Project is located or chartered under the laws of the United States. Bozeman Public Library Children’s Room and Teen Corner Remodel EJCDC C-430 (Penal Sum Form) Bozeman, MT 59715 BID BOND MSR Design #2025021BCR Page 2 of 2 a. Include the cost of bid security in the Bid Amount. 2. After a bid has been accepted, all securities will be returned to the respective bidders and other requested enclosures. If no contract is awarded, all security deposits will be returned.Bidder and Surety, jointly and severally, bind themselves, their heirs, executors, administrators, successors, and assigns to pay to Owner upon default of Bidder the penal sum set forth on the face of this Bond. Payment of the penal sum is the extent of Bidder’s and Surety’s liability. Recovery of such penal sum under the terms of this Bond shall be Owner’s sole and exclusive remedy upon default of Bidder. 3. Default of Bidder shall occur upon the failure of Bidder to deliver within the time required by the Bidding Documents (or any extension thereof agreed to in writing by Owner) the executed Agreement required by the Bidding Documents and any performance and payment bonds required by the Bidding Documents. 4. This obligation shall be null and void if: 4.1 Owner accepts Bidder’s Bid and Bidder delivers within the time required by the Bidding Documents (or any extension thereof agreed to in writing by Owner) the executed Agreement required by the Bidding Documents and any performance and payment bonds required by the Bidding Documents, or 4.2 All Bids are rejected by Owner, or 4.3 Owner fails to issue a Notice of Award to Bidder within the time specified in the Bidding Documents (or any extension thereof agreed to in writing by Bidder and, if applicable, consented to by Surety when required by Paragraph 5 hereof). 5. Payment under this Bond will be due and payable upon default of Bidder and within 30 calendar days after receipt by Bidder and Surety of written notice of default from Owner, which notice will be given with reasonable promptness, identifying this Bond and the Project and including a statement of the amount due. 6. Surety waives notice of any and all defenses based on or arising out of any time extension to issue Notice of Award agreed to in writing by Owner and Bidder, provided that the total time for issuing Notice of Award including extensions shall not in the aggregate exceed 120 days from Bid due date without Surety’s written consent. 7. No suit or action shall be commenced under this Bond prior to 30 calendar days after the notice of default required in Paragraph 5 above is received by Bidder and Surety and in no case later than one year after Bid due date. 8. Any suit or action under this Bond shall be commenced only in a court of competent jurisdiction located in the state in which the Project is located. 9. Notices required hereunder shall be in writing and sent to Bidder and Surety at their respective addresses shown on the face of this Bond. Such notices may be sent by personal delivery, commercial courier, or by United States Registered or Certified Mail, return receipt requested, postage pre-paid, and shall be deemed to be effective upon receipt by the party concerned. 10. Surety shall cause to be attached to this Bond a current and effective Power of Attorney evidencing the authority of the officer, agent, or representative who executed this Bond on behalf of Surety to execute, seal, and deliver such Bond and bind the Surety thereby. 11. This Bond is intended to conform to all applicable statutory requirements. Any applicable requirement of any applicable statute that has been omitted from this Bond shall be deemed to be included herein as if set forth at length. If any provision of this Bond conflicts with any applicable statute, then the provision of said statute shall govern and the remainder of this Bond that is not in conflict therewith shall continue in full force and effect. 12. The term “Bid” as used herein includes a Bid, offer, or proposal as applicable. END OF BID BOND Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman,MT 59715 MSR Design #2025021BCR 01 60 10.01 SUBSTITUTION REQUEST FORM Page 1 of 2 SECTION 01 60 10.01 SUBSTITUTION REQUEST FORM We hereby submit for your consideration the following product instead of the specified item for the following project: PROJECT TITLE _____________________________ PROJECT NO._______________ DRAWING NO._________________DRAWING TITLE ______________________ SPEC.SECTION SPEC.TITLE PARAGRAPH SPECIFIED ITEM ______________ _____________ ___________ _____________________________ Proposed Substitution:_________________________________________________________ Attach complete information on changes to Drawings and/or Specifications which proposed substitution will require for its proper installation. Submit,with request,all necessary samples and substantiating data to prove equal quality and performance to that which is specified.Clearly mark manufacturer's literature to indicate equality in performance. Substitutions of the materials and equipment described in the Contract Documents will be considered during the bidding period upon receipt of a written request to the Architect for approval up to ten (10)days before receipt of bids. Verbal or written requests without the completed Substitution Request Form will not be considered. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE The undersigned states that the function,appearance,and quality are equivalent or superior to the specified item. Submitted by: ___________________________________________________________________________ Signature ___________________________________________________________________________ Firm ___________________________________________________________________________ Address ____________________ ________________________ __________________________ Telephone Email Date Signature shall be by person having authority to legally bind his firm to the above terms.Failure to provide legally binding signature will result in retraction of approval. Fill in Blanks Below: Does the substitution affect dimensions shown on Drawings?Yes No If yes,clearly indicate changes: ________________________________________________________________________ ________________________________________________________________________ Will the undersigned pay for changes to the building design,including engineering and detailing costs caused by the requested substitution?Yes No If no,fully explain: ________________________________________________________________________ ________________________________________________________________________ What effect does substitution have on other Contracts or other trades? ________________________________________________________________________ ________________________________________________________________________ What effect does substitution have on construction schedule? ________________________________________________________________________ ________________________________________________________________________ Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman,MT 59715 MSR Design #2025021BCR 01 60 10.01 SUBSTITUTION REQUEST FORM Page 2 of 2 Manufacturer's warranties of the proposed and specified items are: _________Same __________Different (Explain on Attachment) Reason for Request: ________________________________________________________________________ ________________________________________________________________________ Itemized comparison of specified item(s)with the proposed substitution. List significant variations: ________________________________________________________________________ ________________________________________________________________________ Accurate cost data comparing proposed substitution with product specified: ________________________________________________________________________ ________________________________________________________________________ Designation of maintenance services and sources: ________________________________________________________________________ ________________________________________________________________________ (ATTACH ADDITIONAL SHEETS IF REQUIRED) For Use by Design Professional: _________Recommended _________Recommended as Noted _________Not Recommended _________Received Too Late Signed By _______________________________________________________ Date ___________________________________________________________ For Use by Owner's Representative or Owner: _________Approved _________Approved as Noted _________Not Approved _________Approved Too Late Signed By _______________________________________________________ Date ___________________________________________________________ END OF SECTION Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #2025021BCR 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS Page 1 of 4 SECTION 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS PART 1 GENERAL 1.01 SECTION INCLUDES A. Construction procedures to promote adequate indoor air quality after construction. B. Building flush-out after construction and before occupancy. 1.02 PROJECT GOALS A. Dust and Airborne Particulates: Prevent deposition of dust and other particulates in HVAC ducts and equipment. 1. Cleaning of ductwork is not contemplated under this Contract. 2. Contractor shall bear the cost of cleaning required due to failure to protect ducts and equipment from construction dust. 3. Establish condition of existing ducts and equipment prior to start of alterations. B. Airborne Contaminants: Procedures and products have been specified to minimize indoor air pollutants. 1. Furnish products meeting the specifications. 2. Avoid construction practices that could result in contamination of installed products leading to indoor air pollution. 1.03 RELATED REQUIREMENTS A. Section 01 40 00 - Quality Requirements: Testing and inspection services. B. Section 01 61 16 - Volatile Organic Compound (VOC) Content Restrictions. C. Division 23: HVAC filters; testing HVAC systems for proper air flow rates, adjustment of dampers and registers, and settings for equipment; cleaning air ducts, equipment, and terminal units. 1.04 REFERENCE STANDARDS A. SMACNA (OCC) - IAQ Guidelines for Occupied Buildings Under Construction; 2007. 1.05 DEFINITIONS A. Adsorptive Materials: Gypsum board, acoustical ceiling tile and panels, carpet and carpet tile, fabrics, fibrous insulation, and other similar products. B. Contaminants: Gases, vapors, regulated pollutants, airborne mold and mildew, and the like, as specified. C. Particulates: Dust, dirt, and other airborne solid matter. D. Wet Work: Concrete, plaster, coatings, and other products that emit water vapor or volatile organic compounds during installation, drying, or curing. 1.06 SUBMITTALS A. See Section 01 30 00 - Administrative Requirements for submittal procedures. B. Indoor Air Quality Management Plan: Describe, in detail, measures to be taken to promote adequate indoor air quality upon completion; use SMACNA (OCC) as a guide. 1. Submit not less than 60 days before enclosure of building. 2. Identify potential sources of odor and dust. 3. Identify construction activities likely to produce odor or dust. 4. Identify areas of project potentially affected, especially occupied areas. 5. Evaluate potential problems by severity and describe methods of control. 6. Describe construction ventilation to be provided, including type and duration of ventilation, use of permanent HVAC systems, types of filters and schedule for replacement of filters. 7. Describe cleaning and dust control procedures. C. Interior Finishes Installation Schedule: Identify each interior finish that either generates odors, moisture, or vapors or is susceptible to adsorption of odors and vapors, and indicate air handling zone, sequence of application, and curing times. Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #2025021BCR 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS Page 2 of 4 PART 2 PRODUCTS 2.01 MATERIALS A. Low VOC Materials: See Section 01 61 16. B. Low VOC Materials: See other sections for specific requirements for materials with low VOC content. PART 3 EXECUTION 3.01 CONSTRUCTION PROCEDURES A. Prevent the absorption of moisture and humidity by adsorptive materials by: 1. Sequencing the delivery of such materials so that they are not present in the building until wet work is completed and dry. 2. Delivery and storage of such materials in fully sealed moisture-impermeable packaging. 3. Provide sufficient ventilation for drying within reasonable time frame. B. Begin construction ventilation when building is substantially enclosed. C. If extremely dusty or dirty work must be conducted inside the building, shut down HVAC systems for the duration; remove dust and dirt completely before restarting systems. D. When working in a portion of an occupied building, prevent movement of air from construction area to occupied area. E. Do not store construction materials or waste in mechanical or electrical rooms. F. Prior to use of return air ductwork without intake filters clean up and remove dust and debris generated by construction activities. 1. Inspect duct intakes, return air grilles, and terminal units for dust. 2. Clean plenum spaces, including top sides of lay-in ceilings, outsides of ducts, tops of pipes and conduit. 3. Clean tops of doors and frames. 4. Clean mechanical and electrical rooms, including tops of pipes, ducts, and conduit, equipment, and supports. 5. Clean return plenums of air handling units. 6. Remove intake filters last, after cleaning is complete. G. Do not perform dusty or dirty work after starting use of return air ducts without intake filters. H. Use other relevant recommendations of SMACNA (OCC) for avoiding unnecessary contamination due to construction procedures. 3.02 BUILDING FLUSH-OUT A. Perform building flush-out before occupancy. B. Do not start flush-out until: 1. All construction is complete. 2. HVAC systems have been tested, adjusted, and balanced for proper operation. 3. Inspection of inside of return air ducts and terminal units confirms that cleaning is not necessary. 4. New HVAC filtration media have been installed. C. Building Flush-Out: Operate all ventilation systems at normal flow rates with 100 percent outside air until a total air volume of 14,000 cubic feet per square foot of floor area has been supplied. 1. Obtain Owner's concurrence that construction is complete enough before beginning flush-out. 2. Maintain interior temperature of at least 60 degrees F and interior relative humidity no higher than 60 percent. 3. If additional construction involving materials that produce particulates or any of the specified contaminants is conducted during flush-out, start flush-out over. 4. If interior spaces must be occupied prior to completion of the flush-out, supply a minimum of 25 percent of the total air volume prior to occupancy, and: a. Begin ventilation at least three hours prior to daily occupancy. b. Continue ventilation during all occupied periods. c. Provide minimum outside air volume of 0.30 cfm per square foot or design minimum outside air rate, whichever is greater. Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #2025021BCR 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS Page 3 of 4 D. Install new HVAC filtration media after completion of flush-out and before occupancy or further testing. END OF SECTION Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #2025021BCR 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS Page 4 of 4 8/4/2026 MITCH KARR 8/4/2026 MITCH KARR 8/4/2026 X 8/4/2026 MITCH KARR X 8/4/2026 NO EXCEPTIONS TAKEN By: Date: Meyer, Scherer & Rockcastle, LTD MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEM REJECTED REVISE AND RESUBMIT 4 8/4/2026Mitch RECEIVED Checking is only for general conformance with thedesign concept of the project and general compliancewith the information given in the Contract Documents.Any action shown is subject to the requirements of theplans and specifications. Contractor is responsible for:Dimensions and quantities which shall be confirmedand correlated at the job site; fabrication processesand techniques of construction; coordination of theirwork with that of all other trades and the satisfactoryperformance of their work. NO EXCEPTIONS TAKEN By: Date: Meyer, Scherer & Rockcastle, LTD MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEM REJECTED REVISE AND RESUBMIT 4 8/4/2026Mitch RECEIVED Checking is only for general conformance with thedesign concept of the project and general compliancewith the information given in the Contract Documents.Any action shown is subject to the requirements of theplans and specifications. Contractor is responsible for:Dimensions and quantities which shall be confirmedand correlated at the job site; fabrication processesand techniques of construction; coordination of theirwork with that of all other trades and the satisfactoryperformance of their work. OWNERS FACILITIES STANDARD IS WATTSTOPPER PROJECT CANNOT ACCEPT CONTROLS SUBSTITUTIONS NO EXCEPTIONS TAKEN By: Date: Meyer, Scherer & Rockcastle, LTD MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEM REJECTED REVISE AND RESUBMIT 4 8/4/2026Mitch RECEIVED Checking is only for general conformance with thedesign concept of the project and general compliancewith the information given in the Contract Documents.Any action shown is subject to the requirements of theplans and specifications. Contractor is responsible for:Dimensions and quantities which shall be confirmedand correlated at the job site; fabrication processesand techniques of construction; coordination of theirwork with that of all other trades and the satisfactoryperformance of their work. None None 406.500.7950 Ksmith@MHLighitng.com 8/3/2026 1184 North 15th Avenue, Suite 4 Bozeman, MT 59715 MH Lighting Katie Smith Lighting 260 0000 Lighting See Attached 2025021Bozeman Library Children’s Room Reno 8/4/2026 MITCH KARR See Link above with cut sheets with warranty and service info Not Available until bid https://mhlighting1-my.sharepoint.com/:b:/g/personal/ksmith_mhlighting_com/IQCpkYc7REUBSqeTLgcW543cAUQp8pf6ETj AKzFk4URMi6c?e=RoL1pB More Competitive bid for Lighting X 8/4/2026 X sEcTloN 01 60 10.01 SUBSTITUTION REQUEST FORM We hereby submit for your consideration the following product instead of the specified item for the following project: Bozeman Public Library PROJECT TITLE C'hì 1 drcn ts Ronm Rcmodcl PROJECT NO. 2025021 DRAWING NO.DRAWING TITLE SPEC. SECTION SPEC. TITLE PARAGRAPH SPECIFIED ITEM 23 37 13 Grilles, Reqi-Etcrs--and Diffusers 2.01 Proposed Substitution: MetalAÏre (GreenhecX) Attach complete information on changes to Drawings and/or Specifications which proposed substitution will require for its proper installation. Submit, with request, all necessary samples and substantiating data to prove equal quality and performance to that which is specified. Clearly mark manufacturer's literature to indicate equality in performance. Substitutions of the materials and equipment described in the Contract Documents will be considered during the bidding period upon receipt of a written request to the Architect for approval up to ten (10) days before rece¡pt of bids. Verbal or written requests without the completed Substitution Request Form will not be considered. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE The undersigned states that the function, appearance, and quality are equivalent or superior to the spec item iqht re Sound Air LLC Su Firm 422 gL],:' Street S. Great Falls, MI 59405 Address 406-727-8483 keeli@soundairlnc. com 8/4/26 Telephone Email Date ' Signature shall be by person having authority to legally bind his firm to the above terms. Failure to provide legally binding signature will result in retraction of approval. Fillin Blanks Below: Does the substitution affect dimensions shown on Drawings? lf yes, clearly lndicate changes: Yes @ Will the undersigned pay for changes to the buildiEksign, including engineering and detailing costs caused by the requested substitution? LÞ No lf no, fully explain: What effect does substitution have on other Contracts or other trades? None What effect does substitution have on construction schedule? None Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #20250218CR 016010.01 SUBSTITUTION REQUEST FORM Page 1 of 2 Manufacturer's warranties of the proposed and specified items are: )O( Same Different (Explain on Attachment) Reason for Request: Manufar--trrre not listed in Itemized comparison of specified item(s) with the proposed substitution. List significant va riations: None Accurate cost data comparing proposed substitution with product specified: Designation of maintenance services and sources: (ATTACH ADDTTTONAL SHEETS rF REQUTRED) For Use by Design Professional: Recommended Not Recommended Recommended as Noted Received Too Late Signed By Date For Use by Owner's Representative or Owner: Approved Approved as Noted Not Approved Signed By Date END OF SECTION Bozernan Public Library Children's Room and Teen Corner Remodel Bozernan, MT 59715 MSR Design #20250218CR Approved Too Late 0160 10.01 SUBSTITUTION REQUEST FORM Page2 of 2 x Carly Svenvold, PE 8/4/2026 X 8/5/2026 sEcT¡oN 01 60 10.01 SUBSTITUTION REQUEST FORM We hereby submit for your consideration the following product instead of the specified item for the following project: Bozeman Public Líbrary PROJECT TITLE Õhì 1 dren ¡ s Room Remode'l PROJECT NO.?o?50 DRAWING NO DRAWING TITLE SPEC. SECTION SPEC. TITLE PARAGRAPH SPECIFIED ITEM ?.? 33 00 Air-¡ucr Acceoso¡:å-es -2.O5 Dampers Proposed Substitution êreenheok Attach complete information on changes to Drawings and/or Specifications which proposed substitution will require for its proper installation. Submit, with request, all necessary samples and substantiating data to prove equal quality and performance to that which is specified, Clearly mark manufacturer's literature to indicate equality in performance. Substitutions of the materials and equipment described in the Contract Documents will be considered during the bidding period upon receipt of a written request to the Architect for approval up to ten (10) days before receipt of bids. Verbal or written requests without the completed Substitution Request Form will not be considered. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE The undersigned states that the function, appearance, and quality are equivalent or superior to the specifi item. Sub ght Sor¡nd Air LTÆ Firm422 gt],:. Street S. Great Falls, MI 59405 Address 406-727-8483 keeli@soundairlnc . com B/4/26 Telephone Email Date ' Signature shall be by person having authority to legally bind his firm to the above terms. Failure to provide legally binding signature will result in retraction of approval. Fill in Blanks Below: Does the substitution affect dimensions shown on Drawings? lf yes, clearly indicate changes: Yes @ Will the undersigned pay for changes to the buildi esrgn, including engineering and detailing costs caused by the requested substitution? lf no, fully explain: No What effect does substitution have on other Contracts or other trades? Nrrno What effect does substitution have on construction schedule? None Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #20250218CR 01 60 10.01 SUBSTITUTION REQUEST FORM Page 1 of 2 Manufacturer's warranties of the proposed and specified items are )O( Same Reason for Request: Different (Explain on Attachment) Manrrfar.l'-lrre nol-. 1isf.ed ìn s Itemized comparison of specified item(s) with the proposed substitution List significant va riations: ItTnne Accurate cost data comparing proposed substitution with product specified Designation of maintenance services and sources (ATTACH ADDTTTONAL SHEETS lF REQUTRED) For Use by Design Professional: Recommended Not Recommended Recommended as Noted Received Too Late Signed By Date For Use by Owner's Representative or Owner: Approved _Approved as Noted Not Approved - Approved Too Late Signed By Date END OF SECTION Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #20250218CR 01 60 l_0.01 SUBSTITUTION REQUEST FORM Page2 of 2 x Carly Svenvold, PE 8/4/2026 8/5/2026 X sEcTtoN 0160 10.01 SUBSTITUTION REqUEST FORM We hereby submit for your consideration the following product instead of the specified item for the following project: Bozeman Public Library PROJECT TITLE C1hi I rìrcn rs Room RemorJe'l PROJECT NO )n)^o)'l DRAWING NO.DRAWING TITLE SPEC. SECTION SPEC. TITLE PARAGRAPH SPECIFIED ITEM 23 33 00 Air Duct Accessories 2.08 Duct Mounted Access Doors Proposed Substitution:Greenheek Attach complete information on changes to Drawings and/or Specifications which proposed substitution will require for its proper installation. Submit, with request, all necessary samples and substantiating data to prove equal quality and performance to that which is specified. Clearly mark manufacturer's literature to indicate equality in performance. Substitutions of the materials and equipment descríbed in the Contract Documents will be considered during the bidding period upon receipt of a written request to the Architect for approval up to ten (10) days before receipt of bids. Verbal or written requests without the completed Substitution Request Form will not be considered. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE The undersigned states that the function, appearance, and quality are equivalent or superior to the item. iqht re Sound Air LLC Firm 422 gL]:. Street S. Great Falls, l4T 59405 Address 406-727-8483 keel i@soundairlnc. com 8/4/26 Telephone Email Date ' Signature shall be by person having authority to legally bind his firm to the above terms. Failure to provide legally binding signature will result in retraction of approval. Fillin Blanks Below: Does the substitution affect dimensions shown on Drawings? lf yes, clearly indicate changes: Yes Will the undersigned pay for changes to the build caused by the requested substitution? lf no, fully explain: ö'*",,iïluding engineering and detailing costs What effect does substitution have on other Contracts or other trades? None What effect does substitution have on construction schedule? None Bozeman Public Library Children's Room and Teen Corner Remodel Bozernan, MT 59715 MSR Design #2025021BCR 01 60 10.01 SUBSTITUTION REQUEST FORM Page 1 of 2 Manufacturer's warranties of the proposed and specified items are )Õ( Same Different (Explain on Attachment) Reason for Request: Manufa<--t- rre not 'l i sl:ed i n Itemized comparison of specified item(s) with the proposed substitution. List significant variations: None Accurate cost data comparing proposed substitution with product specified: Designation of maintenance services and sources: (ATTACH ADDTTTONAL SHEETS tF REQUTRED) For Use by Design Professional: Recommended - Recommended as Noted Not Recommended Received Too Late Signed By Date For Use by Owner's Representative or Owner: Approved Not Approved Approved as Noted Approved Too Late Signed By Date END OF SECTION Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #20250218CR 016010.01 SUBSTITUTION REQUEST FORM Page2 of 2 x Carly Svenvold, PE 8/4/2026 X 8/5/2026 sEcÏoN 016010.01 SUBSTITUT¡ON REQUEST FORM We hereby submit for your consideration the following product instead of the specified item for the following project: Bozeman Public Library PROJECTTITLE Clhi'l rìrenrs Room RemorJel PROJ ECT NO. )tt?qo)1 DRAWING NO.DRAWING TITLE SPEC. SECTION SPEC. TITLE PARAGRAPH SPECIFIED ITEM 23 33 00 Aír nuct-Accessorics 2-O4 Manrrr 1 \Inl rrma T)ãmfìêrs ProposedSubstitution: Grccnhec.k Attach complete information on changes to Drawings andlor Specifications which proposed substitution will require for its proper installation. Submit, with request, all necessarysamples and substantiating data to prove equal quality and performance to that which is specified. Clearly mark manufacturer's literature to indicate equality in performance. Substitutions of the materials and equipment described in the Contract Documents will be considered during the bidding period upon receipt of a written request to the Architect for approval up to ten (10) days before receipt of bids. Verbal or written requests without the completed Substitution Request Form will not be considered. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE The undersigned states that the function, appearance, and quality are equivalent or superior to the item. qht ure Sound Air LLC Firm 422 gE]¡, Street S. Great Fal1s, MT 59405 Address 406-727-8483 keeli@soundairlnc. com 8/4/26 Telephone Email Date ' Signature shall be by person having authority to legally bind his firm to the above terms. Failure to provide legally binding signature will result in retraction of approval. Fillin Blanks Below: Does the substitution affect dimensions shown on Drawings? lf yes, clearly indicate changes: Yes @ Will the undersigned pay for changes to the build@þsign, including engineering and detailing costs caused by the requested substitution? (þ,) No lf no, fully explain: What effect does substitution have on other Contracts or other trades? None What effect does substitution have on construction schedule? None Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 5971-5 MSR Design #20250218CR 01 60 10.01 SUBSTITUTION REQUEST FORM Page 1 of 2 Manufacturer's warranties of the proposed and specified items are: )C( Same Different (Explain on Attachment) Reason for Request: Manufaeùrtre not 1ìsterj in snees Itemized comparison of specified item(s) with the proposed substitut¡on List significant variations: None Accurate cost data comparing proposed substitution with product specified Designation of maintenance services and sources: (ATTACH ADDTTTONAL SHEETS tF REqUtRED) For Use by Design Professional: Recommended Not Recommended Recommended as Noted Received Too Late Signed By Date For Use by Owner's Representative or Owner: _ Approved Not Approved Approved as Noted Approved Too Late Signed By Date END OF SECTION Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #20250218CR 0160 10.01 SUBSTITUTION REQUEST FORM Page 2 of 2 x Carly Svenvold, PE 8/4/2026 8/5/2026 X sEcTloN 0160 10.01 SUBSTITUTION REQUEST FORM We hereby submit for your consideration the following product instead of the specified item for the following project: Bozeman public Library PROJECT TITLE clhi 'l ¿ìran I s Room Romodel PROJECT NO. ?025021 DRAWING NO.DRAWING TITLE SPEC. SECTION SPEC. TITLE PARAGRAPH SPECIFIED ITEM 23 33 00 Air duct, accessories 2.03 Backdraft & Pressure.Relief Dampers Proposed Substitution Greenheck Attach complete information on changes to Drawings and/or Specifications which proposed substitution will require for its proper installation. Submit, with request, all necessary samples and substantiating data to prove equal quality and performance to that which is specified. Clearly mark manufacturer's literature to indicate equality in performance. Substitutions of the materials and equipment described in the Contract Documents will be considered during the bidding period upon receipt of a written request to the Architect for approval up to ten (10) days before rece¡pt of bids. Verbal or written requests without the completed Substitution Request Form will not be considered. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE The undersigned states that the function, appearance, and quality are equivalent or superior to the item qht ure Sound Air LLC s Su Firm 422 gE],:l Sùreet S. Great Fal1s, MI 59405 Address 406-727-8483 Telephone Signature shall be by perso provide legally binding sign keel i@soundairlnc. com 8/4/26 Email Date ' n having authority to legally bind his firm to the above terms. Failure to ature will result in retraction of approval. Fillin Blanks Below: Does the substitution affect dimensions shown on Drawings? lf yes, clearly indicate changes: Yes Will the undersigned pay for changes to the buildrÆ*lRsi8 caused by the requested substitution? \Jg,l lf no, fully explain: n, including engineering and detailing costs No What effect does substitution have on other Contracts or other trades? None What effect does substitution have on construction schedule? None Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #20250218CR 01 60 10.01 SUBSTITUTION REQUEST FORM Page t of 2 Manufacturer's warranties of the proposed and specified items are: )O( Same Different (Explain on Attachment) Reason for Request: Manufaetrrre noL liste<j in s Itemized comparison of specified item(s) with the proposed substitution List significant variations: None Accurate cost data comparing proposed substitution with product specified Designation of maintenance services and sources: (ATTACH ADDTTTONAL SHEETS tF REQUTRED) For Use by Design Professionalr Recommended Not Recommended Recommended as Noted Received Too Late Signed By Date For Use by Owner's Representative or Owner _ Approved Approved as Noted Not Approved Signed By Date END OF SECTION Bozeman Public Library Children's Room and Teen Corner Remodel Bozeman, MT 59715 MSR Design #2025021BCR Approved Too Late 01 60 10.01 SU BSTITUTION REQUEST FORM Page2 of 2 x Carly Svenvold, PE 8/4/2026 X 8/5/2026 Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman,MT 59715 MSR Design #2025021BCR 01 60 10.01 SUBSTITUTION REQUEST FORM Page 1 of 2 SECTION 01 60 10.01 SUBSTITUTION REQUEST FORM We hereby submit for your consideration the following product instead of the specified item for the following project: PROJECT TITLE _____________________________ PROJECT NO._______________ DRAWING NO._________________DRAWING TITLE ______________________ SPEC.SECTION SPEC.TITLE PARAGRAPH SPECIFIED ITEM ______________ _____________ ___________ _____________________________ Proposed Substitution:_________________________________________________________ Attach complete information on changes to Drawings and/or Specifications which proposed substitution will require for its proper installation. Submit,with request,all necessary samples and substantiating data to prove equal quality and performance to that which is specified.Clearly mark manufacturer's literature to indicate equality in performance. Substitutions of the materials and equipment described in the Contract Documents will be considered during the bidding period upon receipt of a written request to the Architect for approval up to ten (10)days before receipt of bids. Verbal or written requests without the completed Substitution Request Form will not be considered. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE The undersigned states that the function,appearance,and quality are equivalent or superior to the specified item. Submitted by: ___________________________________________________________________________ Signature ___________________________________________________________________________ Firm ___________________________________________________________________________ Address ____________________ ________________________ __________________________ Telephone Email Date Signature shall be by person having authority to legally bind his firm to the above terms.Failure to provide legally binding signature will result in retraction of approval. Fill in Blanks Below: Does the substitution affect dimensions shown on Drawings?Yes No If yes,clearly indicate changes: ________________________________________________________________________ ________________________________________________________________________ Will the undersigned pay for changes to the building design,including engineering and detailing costs caused by the requested substitution?Yes No If no,fully explain: ________________________________________________________________________ ________________________________________________________________________ What effect does substitution have on other Contracts or other trades? ________________________________________________________________________ ________________________________________________________________________ What effect does substitution have on construction schedule? ________________________________________________________________________ ________________________________________________________________________ Bozeman Library 265100 see attached bom Amy Nickelson The Lighting Agency 219A N Broadway, Billings MT 59101 406-245-7116 anickelson@thelightingagency.com 8/4/2026 none no Bozeman Public Library Children’s Room and Teen Corner Remodel Bozeman,MT 59715 MSR Design #2025021BCR 01 60 10.01 SUBSTITUTION REQUEST FORM Page 2 of 2 Manufacturer's warranties of the proposed and specified items are: _________Same __________Different (Explain on Attachment) Reason for Request: ________________________________________________________________________ ________________________________________________________________________ Itemized comparison of specified item(s)with the proposed substitution. List significant variations: ________________________________________________________________________ ________________________________________________________________________ Accurate cost data comparing proposed substitution with product specified: ________________________________________________________________________ ________________________________________________________________________ Designation of maintenance services and sources: ________________________________________________________________________ ________________________________________________________________________ (ATTACH ADDITIONAL SHEETS IF REQUIRED) For Use by Design Professional: _________Recommended _________Recommended as Noted _________Not Recommended _________Received Too Late Signed By _______________________________________________________ Date ___________________________________________________________ For Use by Owner's Representative or Owner: _________Approved _________Approved as Noted _________Not Approved _________Approved Too Late Signed By _______________________________________________________ Date ___________________________________________________________ END OF SECTION yes alternate manufacturers 2026.08.05 MITCH KARR PROPOSALS STRUCK THROUGH ON THE FOLLOWING PAGE ARE REJECTED. REVIEWED AS SUBSTIUTION REQUEST ONLY. FULL APPROVAL AND REVIEW OF LIGHTING PACKAGE VIA CONSTRUCTION SUBMITTALS X 8/5/2026 Project:BOZEMAN LIBRARY CHILDREN'SBid Date:08/13/26Engineer:MORRISON MAIERLEAttn:RYAN MARONEYListed below are the manufacturers and products that we respectfully submit for prior approval on this project:If there are any questions, please feel free to contact Amy Nickelson at our office.1. APPROVED 3. RESUBMIT$OS 4. REJECTEDACTIONTYPE MANUFACTURER DESCRIPTION MANUFACTURER DESCRIPTIONTAKEND1 WILLIAMS GOTHAMIVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWRD2 WILLIAMS GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWRG1 LUMENWERX SAL S2C20-1N05-FINISH-OAHU1 WILLIAMS NEWSTAR MUS-3-HC-L1-35-80CRI-DM-RSV1LUMENWERX SALS7240-L10-35-FINISHCOMMENTS: FAX: 406-245-7703P R I O R A P P R O V A L S U B M I T T A L E N C L O S U R EPROPOSALSPECIFIED FIXTUREThe Lighting Agency North219 N. Broadway, Suite ABillings, MT 59101406-245-7116PROPOSALS STRUCK THROUGH ARE REJECTED. REVIEWED AS SUBSTIUTION REQUEST ONLY. FULL APPROVAL AND REVIEW OF LIGHTINGPACKAGE VIA CONSTRUCTION SUBMITTALS GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 1 of 9 Luminaire Type: Catalog Number: Flanged Flangeless Flangeless in Millwork •Perfect Color™ consistency within ½-step MacAdam Ellipse •Exceptional color rendering with 80 CRI, 90 CRI, or 95 CRI minimum •Bounding Ray™ optical design delivers low brightness apertures for a comfortable lighting experience •45° visual cut-off angle to source •Up to 90% lumen maintenance at 55,000 hours •Wet Location optional, covered ceiling •Easy installation and servicing with snap-in Driver •Batwing distributions with feathered edges to provide even illumination fixture-to-fixture •Clean beams with soft transitions from narrow spot up to wide flood distributions •Field changeable optics available every 5° Feature Set IVO 4" Round Product Family IVO™ 4" Round Downlight New Construction Superior Perfomance* Nominal Lumens 05LM 07LM 10LM 15LM 20LM 25LM 30LM 35LM 40LM 45LM Delivered Lumens 493 735 991 1486 1968 2447 2732 3313 3796 4236 Wattage 5.1 7.3 9.8 15.0 20.5 26.8 29.7 34.4 41.8 45.3 Lumens per Watt 96 100 101 99 96 91 92 96 91 94 *Based on 3500K MWD 80CRI P AR LSS Distribution / Beam AnglesTRIM STYLES AND COLORSPRODUCT FAMILYQUICK SPECIFICATIONSReflector ColorsFlange Styles New construction housing shown. Please see page 6 for full set of dimensional drawings. 4.5" x 8.2" x 11.0" Parabolic Clear Alzak Gold Pewter Wheat Black White White Anti‑Microbial Soft White Bronze CAN BE USED TOCOMPLY WITH 2019 JA8 HIGH EFFICACY LED LIGHT SOURCE REQUIREMENTS 45°30°10°15°20°25°35°40°50°60°55°MWD1.0 S/MH65° WD1.2 S/MH75° MD0.8 S/MH60° Downlight Lensed WW Surface Cylinder Pendant Cylinder Wall Cylinder Wall Adjustable Cylinder Bevel IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR NO EXCEPTIONS TAKEN By: Date: Meyer, Scherer & Rockcastle, LTD MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEM REJECTED REVISE AND RESUBMIT 4 8/5/2026Mitch RECEIVED Checking is only for general conformance with thedesign concept of the project and general compliancewith the information given in the Contract Documents.Any action shown is subject to the requirements of theplans and specifications. Contractor is responsible for:Dimensions and quantities which shall be confirmedand correlated at the job site; fabrication processesand techniques of construction; coordination of theirwork with that of all other trades and the satisfactoryperformance of their work. GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 2 of 9 IVO™ 4" Round Downlight New Construction Luminaire Type: Catalog Number:ORDERING INFORMATIONEXAMPLE: IVO4 D 10LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS F Series Function Lumen Packages Kelvin Temperature Color Rendering Index Distribution IVO4 4" Round Recessed D Downlight 05LM 1 500 Lumens 07LM 750 Lumens 10LM 1000 Lumens 15LM 1500 Lumens 20LM 2000 Lumens 25LM 2500 Lumens 30LM 3000 Lumens 35LM 3500 Lumens 40LM2 4000 Lumens 45LM3 4500 Lumens 27K 2700K 30K 3000K 35K 3500K 40K 4000K 50K 5000K 80CRI 80+ CRI 90CRI4 90+ CRI 95CRI4 95+ CRI Narrow / Flood 10D 10°30D 30°50D 50° 15D 15°35D 35°55D 55° 20D 20°40D 40°60D 60° 25D 25°45D 45° General Illumination / Batwing MD Medium Batwing (0.8 s/mh, 60°) MWD Medium Wide Batwing (1.0 s/mh, 65°) WD Wide Batwing (1.2 s/mh, 75°) Dimming Level Voltage Control Input6 Emergency Option Housing Style MIN10 Min 10% Dim Level MIN1 Min 1% Dim Level DARK Min 0.1% Dim Level, Dim-to-Dark MVOLT Multi-Volt input, 120V-277V 120 120V input 3475 347V input ZT7 Generic 0-10V EZT EldoLED 0-10V ELV8 Phase Dimming (Forward/Reverse) (120V only) DMX9 DMX DALI9 DALI-2 NLIGHT Embedded wired controls by nLight NLTAIR2 Embedded wireless controls by nLight NLIGHTER Embedded wired controls by nLight with UL924 listed emergency operation NLTAIREM2 Embedded wireless controls by nLight with UL924 listed emergency operation (blank)No Emergency Pack E7W10 IOTA 7W Emergency battery pack, Constant Power, Title 20 compliant, integrated test switch.E7WR10,11 IOTA 7W Emergency battery pack, Constant Power, Title 20 compliant, remote test switch. E10W12 IOTA 10W Emergency battery pack, Constant Power, Title 20 compliant, integrated test switch E10WR12 IOTA 10W Emergency battery pack, Constant Power, Title 20 compliant, remote test switch. GTD9,13 Generator Transfer Device NCH Non-IC Housing (new construction only) ICAT IC/Airtight Housing (new construction only) 15LM max. CP Chicago Plenum CCEA Housing (new construction only) Options Trim Style Baffle Color Trim Lens Trim Color Trim Finish Flange Style SF14 Single Fuse, specify 120 or 277 WL15 Wet Location P Parabolic Trim BEV16 Bevel Trim SH16,17 Shower/IP65 Bevel Trim (Deadfront) (blank)non-Bevel ARS Clear Anodized Semi-Specular WMRS Soft White BRS Black Semi-Specular BRD Black Diffuse (blank)no lens SLG Solite Lens CLR Clear Lens AR Clear Anodized BR Black Anodized GR Gold Anodized PR Pewter Anodized WTR Wheat Anodized WR 16,18 White Gloss (painted) WMR 16 Soft White Matte (painted) WRAMF 16 White Gloss with Anti-Microbial (painted) BZR 16,18 Dark Bronze (painted) TRALTBD 19 Trim RAL # (TBD for pricing only) TCPC Trim Custom Paint Color LD Matte Diffuse LS Specular LSS Semi Specular F Self Flanged (color matches trim) FL Flangeless (Drywall) FLM 20 Flangeless Millwork FBL21 Flange Only Black FWR 22 Flange Only White FRALTBD 19 Flange Only RAL FCPC Flange Only Custom Paint Color Design Select options indicated by this color background. Maximum order quantity for design select lead times is 100 ORDERING NOTES 1. 05LM only available with ELV or ZT. Not available with 347V. 2. 40LM and CP requires Marked Spacing. 3. 45LM and NCH requires Marked Spacing. 4. 90CRI not available with 50K, 95CRI not available with 35K, 40K or 50K. 5. 347 only available with ZT and MIN1 or MIN10. Not available with nLight or Emergency options. 40LM max. 6. Refer to Tech-240 for compatible dimmers. 7. ZT is not available with DARK. 8. ELV only available with MIN1 and 120V. 9. DMX and DALI are only available with DARK. 10. E7W and E7WR and not available with ICAT. 11. E7WR is not available with CP housings. 12. E10W, E10WR and GTD not available with ICAT or CP. Not available with NLIGHTER or NLTAIREM2. 13. GTD only available with NCH and ZT, ELV, or EZT. 14. Specify 120 or 277 volt. Not available with 347 volt. 15. Not available with E7W or E10W 16. Not available with Trim Finishes. 17. SH Trim not available with FL or FLM flange style. 18. Corrosion Resistant Powder Coat. 19. Replace with applicable RAL number and finish when ready to order. See RAL BROCHURE for available color options. 20. FLM requires Millwork Ceiling Cutout Template accessory, IVO*FLMKIT. Millwork Router Bit accessory, IVOFLMBIT, is optional or use similar. Millwork Adapter is included. 21. For use with different reflector flange color only (i.e AR, BZR, GR, PR, WR, WTR, WMR, WRAMF). Not available with BR (black reflector) or FL or FLM (flangeless) options. 22. For use with different reflector flange color only (i.e AR, BR, BZR, GR, PR, WTR). Not available with WR, WMR, WRAMF (white reflector) or FL or FLM (flangeless) options. IVO™ IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT P AR LSS NCH FWR BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 3 of 9 IVO™ 4" Round Downlight New Construction ACCESSORIES — order as separate catalog numbers (shipped separately) GRA4-6IVO Round goof ring adapter 4" ID, 6.5" OD SCA4 Sloped ceiling adaptor. Degree of slope must be specified (5D, 10D, 15D, 20D, 25D, 30D). Ex: SCA4 10D. Refer to TECH-190 for details. CTAIVODL20 Trim ceiling thickness adaptors for 1-1/4" to 2" thick ceilings and ≤ 30LM (includes set of two for one trim). CTAIVODL27 Trim ceiling thickness adaptors for 2" to 2-3/4" thick ceilings and ≤ 30LM (includes set of two for one trim). CTAIVODL30 Trim ceiling thickness adaptors for 2-3/4" to 3" thick ceilings and ≤ 30LM (includes set of two for one trim). IVO4FLMKIT IVO 4” Round Flangeless in Millwork Ceiling Cutout Template (min. 1 required, to be re-used for multiple luminaire installations) IVOFLMBIT IVO Flangeless in Millwork Straight Router Bit, ¼” Shank with Bearing (optional, to be re-used for multiple luminaire installations) IVO4OPTC D MD Field Replaceable 4" Downlight Optic, Medium Batwing Distribution, 0.8 s/mh IVO4OPTC D MWD Field Replaceable 4" Downlight Optic, Medium Wide Batwing Distribution,1.0 s/mh IVO4OPTC D WD Field Replaceable 4" Downlight Optic, Wide Batwing Distribution, 1.2 s/mh IVO4OPTC D 10D Field Replaceable 4" Downlight Optic, 10° IVO4OPTC D 15D Field Replaceable 4" Downlight Optic, 15° IVO4OPTC D 20D Field Replaceable 4" Downlight Optic, 20° IVO4OPTC D 25D Field Replaceable 4" Downlight Optic, 25° IVO4OPTC D 30D Field Replaceable 4" Downlight Optic, 30° IVO4OPTC D 35D Field Replaceable 4" Downlight Optic, 35° IVO4OPTC D 40D Field Replaceable 4" Downlight Optic, 40° IVO4OPTC D 45D Field Replaceable 4" Downlight Optic, 45° IVO4OPTC D 50D Field Replaceable 4" Downlight Optic, 50° IVO4OPTC D 55D Field Replaceable 4" Downlight Optic, 55° IVO4OPTC D 60D Field Replaceable 4" Downlight Optic, 60° Items marked by a shaded background qualify for the Design Select program and ship in 15 days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect. *See ordering tree for details IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 4 of 9 IVO™ 4" Round Downlight New Construction DIMENSIONAL DATA •Dimensions in inches [millimeters] are overall width and height (including mounting hardware Butterfly Brackets / Hanger Bars), length excludes extendable Hanger Bars. •½" clearance on all sides from non‑combustible materials for non‑IC applications required, unless marked spacing is noted otherwise. •nLight Air Antenna extends 1.5" off the end of the j‑box (lengthwise). •Ceiling cutout for Flanged or Flangeless Trim is 5.0" •Fixture with Marked Spacing require the following clearances (min): 24" center‑to‑center, 12" center to side building member, 2" overhead to building member •Hanger Bars are extendable from 8.5" to 24". New Construction Dimensions Non-IC Housing (NCH)For 05LM to 30LM 4.5" [114mm] height 0.5"[12.7mm] collar depth7.3"[184mm] center of aperture 11.0"[279mm] length 8.1"[207mm] width 2x1.5"[38.1mm] butterfly bracket Non-IC Housing (NCH)For 35LM to 40LM 6.9" [175mm] 0.5"[12.7mm] 7.3"[184mm] 11.0"[279mm] 8.1"[207mm] 2x1.5"[38.1mm] Non-IC Housing (NCH)For 45LM – MARKED SPACING24” x 12” x 2” 6.9" [175mm] 0.5"[12.7mm] 7.3"[184mm] 11.0"[279mm] 8.1"[207mm] 2x1.5"[38.1mm] Chicago Plenum Housing (CP)For 05LM to 25LM 5.2" [132mm] 0.5"[12.7mm] 6.9"[175mm] 11.0"[279mm] 8.1"[207mm] 2x1.5"[38.1mm] Chicago Plenum, New Construction Housing (CP)For 30LM to 35LM 7.3" [185mm] 0.5"[12.7mm] 6.9"[175mm] 11.0"[279mm] 8.1"[207mm] 2x1.5"[38.1mm] Chicago Plenum Housing (CP)For 40LM – MARKED SPACING24” x 12” x 2” 7.3" [185mm] 0.5"[12.7mm] 6.9"[175mm] 11.0"[279mm] 8.1"[207mm] 2x1.5"[38.1mm] IC rated Housing (ICAT)For 05LM to 15LM 5.2" [132mm] 0.5"[12.7mm] 7.3"[184mm] 11.0"[279mm] 8.1"[207mm] 2x1.5"[38.1mm] Non-IC Housing (NCH) with E7Wx, E10Wx Emergency Battery For 07LM to 30LM 0.5"[12.7mm] 4.5" [114mm] 8.5"[216mm] 17.4"[442mm] 1.5"[38.1mm] 12.2"[310mm] Non-IC Housing (NCH) with E7Wx, E10Wx Emergency Battery For 35LM to 45LM 6.9" [175mm] 0.5"[12.7mm] 8.5"[216mm] 17.4"[442mm] 1.5"[38.1mm] 12.2"[310mm]Generator Transfer Device Housing (GTD)For 07LM to 30LM 4.5" [114mm] 0.5"[12.7mm] 8.5"[216mm] 13.2"[335mm] 1.5"[38.1mm] 10.3"[262mm] Generator Transfer Device Housing (GTD)For 35LM to 45LM 6.9" [175mm] 0.5"[12.7mm] 8.5"[216mm] 13.2"[335mm] 1.5"[38.1mm] 10.3"[262mm] IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 5 of 9 IVO™ 4" Round Downlight New Construction TRIM OPTIONSTrim Style and Flange Option •Dimensions in inches [millimeters] Trim Color Optical Finish Parabolic Flanged(P) (F) Bevel Flanged(BEV) (F) Clear Anodized(AR) Wheat Anodized (WTR) Semi‑Specular(LSS) Parabolic Flangeless(P) (FL) Bevel Flangeless(BEV) (FL) Soft WhiteMatte Painted(WMR) Dark Bronze Gloss Painted(BZR) Specular(LS) Parabolic Flangeless Millwork(P) (FLM) Bevel Flangeless Millwork(BEV) (FLM) Black Anodized (BR) WhiteGloss Painted(WR) Matte Diffuse(LD) Gold Anodized (GR) White Anti‑MicrobialGloss Painted(WRAMF) Pewter Anodized (PR) Note: These colors were carefully reproduced to give as true a depiction as possible of the finished product color. Some colors, however, may vary slightly from actual appearance due to display/printing variations and limitations. Please contact a Gotham representative for an Architectural Color Chip Kit (GCOLORS KIT), consisting of Powder-Coated and Plated Finishes. Parabolic Flanged shown. Clear Anodized shown. Bevel Solite Lens Flanged(BEV) (SLG) (F) 4.30in 109mm 5.50in 140mm 2.96in75mm 3.08in78mm 4.30in109mm 2.96in75mm 4.77in121mm 3.08in 78mm 2.97in75mm 3.17in81mm 5.50in 140mm .76in 19mm 3.08in78mm 2.97in75mm 3.17in81mm .76in 19mm 4.77in121mm 3.08in78mm Emergency with Integrated Test Switch(E7W, E10W) IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 6 of 9 IVO™ 4" Round Downlight New Construction TABLES OF USEFLANGELESSDimming ConfigurationsDimming Level Control Input Dimming Level Driver Dim Curve Recommended Control Dim Curve MIN10 +ZT 100% to 10%Linear Linear/Logarithmic +EZT 100% to 10%Linear Linear/Logarithmic MIN1 +ZT 100% to 1%Linear Linear/Logarithmic +EZT 100% to 1%Linear Linear/Logarithmic +ELV 100% to 1%*n/a n/a DARK +EZT 100% to 0.1%Logarithmic Linear +DMX 100% to 0.1%Square Linear +DALI 100% to 0.1%Logarithmic Linear Embedded Nlight ConfigurationsDimming Level Control Input Dimming Level Control Provided Driver Provided MIN10 +NLIGHT 100% to 10%NIO EZDXA eldoLED ECOdrive +NLIGHTER 100% to 10%NIO EZDCL ER eldoLED ECOdrive +NLTAIR2 100% to 10%RIO EZDL G2 eldoLED ECOdrive +NLTAIREM2 100% to 10%RIO EZDL EM G2 eldoLED ECOdrive MIN1 +NLIGHT 100% to 1%NIO EZDXA eldoLED ECOdrive +NLIGHTER 100% to 1%NIO EZDCL ER eldoLED ECOdrive +NLTAIR2 100% to 1%RIO EZDL G2 eldoLED ECOdrive +NLTAIREM2 100% to 1%RIO EZDL EM G2 eldoLED ECOdrive DARK +NLIGHT 100% to 0.1%NIO EZDXA eldoLED SOLOdrive +NLIGHTER 100% to 0.1%NIO EZDCL ER eldoLED SOLOdrive +NLTAIR2 100% to 0.1%RIO EZDL G2 eldoLED SOLOdrive +NLTAIREM2 100% to 0.1%RIO EZDL EM G2 eldoLED SOLOdrive * ELV Minimum Dimming level depends on dimmer and dimmer load Flangeless Installation Gotham’s flangeless option utilizes a micro‑thin polymer mud ring that minimizes the amount of drywall compound required to finish the ceiling. The end result is a virtually undetectable flangeless downlight installation. The polymer mud ring is installed independent of the of the recessed frame, therefore floating with the ceiling. This innovation minimizes any surface cracks during reflector installation, ceiling movement and any future service to the recessed frame, wiring, electronics, etc. Flangeless Millwork Installation IVO’s Flangeless in Millwork solution makes installation easy and precise. First, cut a hole in the Wood Ceiling using the Millwork Cutout Template (sold separately). Second, once Housing and ceiling are mounted in place, insert sheet metal Millwork Adapter (provided) lining up edge of tab with bottom of ceiling. Third, secure in place using finishing nails (provided) then remove tabs from Millwork Adapter. Last, install Trim! Partially finished mud ring, showing cross‑section detail. Insert Millwork Adapter into precision‑cut hole. An IVO downlight requires only approximately 3" of plaster to finish. Secure with finishing nails. IVO with flangeless trim Insert Trim and Module. How to Estimate Delivered Lumens in Emergency Mode Delivered Lumens = 1.25 x P x LPW P = Output Power/Wattage of Emergency Battery Driver (E7WR* = 7W, E10WR* = 10W, E15WR* = 15W) LPW = Lumen per Watt rating of luminaire based on Ordering Code selections IVO4D Title 24, JA8 Energy Star Drivers:ZT, EZT, ELV, DMX ZT, EZT, ELV, DMX, DALI DOWNLIGHT80CRI 2700K 5,6 3000K 5,6 3500K 5,6 4000K 5,6 5000K 5,6 90CRI 2700K 1,2,3 5,6 3000K 1,2,3 5,6 3500K 1,2,3 5,6 4000K 1,2,3 5,6 95CRI 2700K 1,2,3,4 3000K 1,2,3,4 1 ‑ 05LM, 07LM, 10LM, 15LM with ICAT housings only2 ‑ 347V, DALI, NLIGHT(ER), & NLTAIR(EM)2 excluded3 ‑ Emergency options excluded4 ‑ 95CRI + P trim with BR or BZR finishes excluded5 ‑ 05LM excluded6 ‑ 07LM + P trim with BR or BZR finishes excluded IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 7 of 9 IVO™ 4" Round Downlight New Construction SPECIFICATIONSOptical System •Bounding Ray™ optical design delivers low brightness apertures for a comfortable lighting experience and ensures no source image up to cut‑off angle, minimizing glare. •45° visual cut‑off angle to source •Top‑Down Flash characteristics avoids flash on trim until source becomes visible. •Batwing distributions with feathered edges to provide even illumination fixture‑to‑fixture. Available with 0.8, 1.0, and 1.2 spacing‑to‑mounting‑height ratio (s/mh). •Clean beams with soft transitions from narrow spot up to wide flood distributions with optics available every 5° •Optics are field changeable (tool‑free). LED Light Engine •Perfect Color™ consistency within ½‑step MacAdam Ellipse using proprietary pick and place algorithm •90% lumen maintenance at 55,000 hours. •Available in 80, 90, or 95 CRI. 90CRI has R9 greater than 50, 95 CRI has R9 greater than 80. Trims •Trims are field changeable via twist‑lock (tool‑free). •Trims are available in 9 colors and 3 surface finishes (standard) •Custom RAL and Paint colors available upon request. •Wall Wash and Downlight Trims are designed to be interchangeable. •Trim lenses are made of Tempered Glass. Electrical •120, 347, or Multi‑Volt (MVOLT) 120‑277 VAC input at 50/60 Hz •Power Factor > 85% •Input wires 18 AWG, 600V minimum, copper •Fixtures are ROHS compliant EMI/RFI •EMI/RFI per FCC Title 47 CFR, Part 15, Class A rated standard. Controls (Optional) •Luminaire can be equipped with interface for nLight wired, allowing it to communicate over an nLight network. Couple with nLight‑enabled sensors, power packs, or WallPods using CAT‑5 cabling to create an nLight Control Zone. Link Control Zone to a Gateway directly or via a Bridge for remote status monitoring and control using SensorView software. •Luminaire can be equipped with interface for nLight Air, allowing it to communicate over the wireless nLight control platform. Can be paired to other luminaires and wall switches through CLAIRITY+, a mobile app, which allows individual fixture control. Dimming •Luminaire Is capable of continuous dimming without perceivable flicker (stroboscopic) as measured by flicker index (ASNI/IES RP‑16‑10). •Available dimming ranges include: 100%‑10% (MIN10), 100%‑1% (MIN1), and 100%‑0.1% (DARK) of rated lumen output. •Available with smooth shut off function from minimum dimming level to 0%. •EldoLED drivers (EZT, DALI) conform to IEEE P1789 standards. •Drivers are inaudible in 24dB environment and stable even when input voltage conditions experience typical commercial environment fluctuations. Emergency Battery (Optional) •Luminaires equipped with battery pack (E7W, E10W, E15W) comply with NFPA 101 (Life Safety Code) and deliver constant light output for a duration of 90 minutes minimum with AC power loss. •Self‑Diagnostic Capability allows the emergency battery pack to automatically conduct Life Safety Code tests on a monthly or annual basis. Self‑Diagnostic Capability can be disabled if preferred. •Stainless steel test switch with green light charging indicator for a discreet and attractive solution to complement the luminaire aesthetic. •Emergency battery is CEC T20 compliant. Installation •Patent‑pending Wire‑Form Mounting Springs with custom profile facilitates effortless installation, maintains tension across various ceiling thicknesses, and ensures a snug‑fit of the trim to the ceiling with no sag. •Plug‑in Driver design allows for quick and easy installation and servicing. •Light Engine, Driver, Housing, and Trim can be installed tool‑free. •Ceiling Thickness Adapters available for 1.25" to 3" thick ceilings. Construction •Access to Light Engine, Driver, and branch circuit conductors is available from below the ceiling without the use of tools. •Universal Mounting Butterfly Brackets can adjust vertically 2.5" and accept various mounting bars including ¾" and 1‑1/2" C Channel, ½" or ¾" Flat Strap, ½" Conduit, and ½" Angle Bars, as well as standard Hanger Bars (included). •Hanger Bars are extendable from 8.5" to 24". •Luminaire is constructed with 20 gauge min cold‑rolled steel, galvanized steel, and aluminum. Listings •Fixtures are CSA certified to meet US and Canadian standards. •Fixtures are NOM certified to meet Mexican standards •All fixtures are manufactured in strict accordance with the appropriate and current requirements of the "Standards for Safety" per UL. •Damp Location standard. •Wet Location (WL) available, covered ceiling required. Photometrics •All photometry is conducted by IESNA standard LM‑79‑08 in an accredited lab. •LEDs are tested to LM‑80 standards. Lumen maintenance is calculated via TM‑21. Warranty •5‑year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms‑and‑conditions Note: •Actual performance may differ as a result of end‑user environment and application. •All values are design or typical values, measured under laboratory conditions at 25 °C. •The product images shown are for illustration purposes only and may not be an exact representation of the product. Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provided consistent color appearance and out‑of‑the‑box control capability with simple commissioning when used with Acuity Brands controls products. All configurations of this luminaire are calibrated and tested meet the Acuity Brands' specification for chromatic consistency ‑ including color rendering, color fidelity and color temperature tolerance around standard CIE chromaticity coordinates. To learn more about A+, visit www.acuitybrands.com/aplus. IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 8 of 9 IVO™ 4" Round Downlight New Construction PHOTOMETRYMD Medium Beam 35 Degree Beam 50 Degree Beam IVO4 D 20LM 35K 80CRI MD P AR LSS IVO4 D 20LM 35K 80CRI 35D P AR LSS IVO4 D 20LM 35K 80CRI 45D P AR LSS Wattage: 20.5, Lumens: 1920, LPW: 94, S/MH: ..8, Test No: 24-850-22P801 Wattage: 20.5, Lumens: 2044.6, LPW: 100, S/MH: .54, Test No: 24-850-34P401 Wattage: 20.5, Lumens: 1920.1, LPW: 94, S/MH: .8, Test No: 24-850-11P809 Lens Multiplier None 1.00 SLG 0.96 CLR 0.93 Trim Color and Finish Multiplier Trim Color Trim Finish Multiplier AR LSS 1.00 AR LS 1.06 AR LD 0.97 GR LSS 0.97 GR LS 0.98 GR LD 0.92 PR LSS 0.97 PR LS 0.97 PR LD 0.90 BR LSS 0.68 BR LS 0.68 BR LD 0.68 WTR LSS 0.87 WTR LS 0.89 WTR LD 0.87 WR 1.03 WMR 1.03 WRAMF 1.04 BZR 0.68 Zonal Lumen Summary Zone Lumens % 0-30 1435 74.7% 0-40 1798.4 93.7% 0-60 1914 99.7% 0-90 1920.1 100% Zonal Lumen Summary Zone Lumens % 0-30 1778.1 87.0% 0-40 1992.7 97.5% 0-60 2040.2 99.8% 0-90 2044.6 100% Zonal Lumen Summary Zone Lumens % 0-30 1435 74.7% 0-40 1798.4 93.7% 0-60 1914 99.7% 0-90 1920.1 100.0% Cone of Light Mounting Height Initial FC Center Beam Beam Diameter (ft) Horizontal Vertical 8' 40.67 7.6 7.6 10'26.03 9.5 9.5 12'18.07 11.4 11.4 14'13.28 13.3 13.3 16'10.17 15.2 15.2 Cone of Light Mounting Height Initial FC Center Beam Beam Diameter (ft) Horizontal Vertical 8' 79.94 4.8 4.8 10'51.16 6 6 12'35.53 7.2 7.2 14'26.1 8.4 8.4 16'19.99 9.6 9.6 Cone of Light Mounting Height Initial FC Center Beam Beam Diameter (ft) Horizontal Vertical 8' 40.67 7.6 7.6 10'26.03 9.5 9.5 12'18.07 11.4 11.4 14'13.28 13.3 13.3 16'10.17 15.2 15.2 Candela Summary 0°2603 10°2366 20°1784 30°909 40°319 50°26 60°6 70°3 80°1 90°0 Candela Summary 0°5116 10°3734 20°2039 30°675 40°120 50°14 60°4 70°2 80°1 90°0 Candela Summary 0°2603 10°2366 20°1784 30°909 40°319 50°26 60°6 70°3 80°1 90°0 UGR (70% 50% 20% reflectance using a 4H x 8H room size) Lumen Package Crosswise Endwise MD MWD WD MD MWD WD 05LM 0 0 0 0 0 0 07LM 0 0 0.7 0 0 0.7 10LM 0 0.1 1.8 0 0.1 1.8 15LM 1.4 1.5 3.2 1.4 1.5 3.2 20LM 2.4 2.5 4.2 2.4 2.5 4.2 25LM 3.1 3.3 4.9 3.1 3.3 4.9 30LM 3.8 3.9 5.6 3.8 3.9 5.6 35LM 4.2 4.3 6 4.2 4.3 6 40LM 4.7 4.8 6.4 4.7 4.8 6.4 45LM 5 5.2 6.8 5 5.2 6.8 CRI/CCT Multiplier CRI CCT Multiplier 80 2700K 0.92 3000K 0.96 3500K 1.00 4000K 1.01 5000K 1.04 90 2700K 0.80 3000K 0.85 3500K 0.85 4000K 0.89 95 2700K 0.68 3000K 0.75 *UGR varies based on luminaire options and is affected by application dependent parameters. Numbers depicted here are considered "Luminaire‑UGR" and/or "Point‑UGR" values. To determine a more precise maximum UGR value ("Application‑UGR"), a full lighting design layout should be completed with the selected luminaire configuration for each application. **Calculated using an AR (Clear reflector) with LSS (Semi‑Specular) finish UGR of zero for fixtures aimed at nadir with a cut‑off equal to or less than 60deg per CIE 117‑1995 Discomfort Glare in Interior Lighting. UGR FAQ Polar Candela Distribution 2,700 2,250 1,800 1,350 900 450 0.00 450 900 1,350 1,800 2,250 2,700 VA:0°10°20°30°40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°150°160°170°180° - 0° H - 90° H Polar Candela Distribution 5,200 4,333 3,467 2,600 1,733 867 0.00 867 1,733 2,600 3,467 4,333 5,200 VA:0°10°20°30°40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°150°160°170°180° - 0° H - 90° H Polar Candela Distribution 2,700 2,250 1,800 1,350 900 450 0.00 450 900 1,350 1,800 2,250 2,700 VA:0°10°20°30°40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°150°160°170°180° - 0° H - 90° H Trim Type Multiplier Trim Style Trim Finish Multiplier P LSS 1.00 BEV ARS 0.79 BEV WMRS 0.79 BEV BRS 0.66 BEV BD 0.60 IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2026 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/02/26 Specifications subject to change without notice. IVO4page 9 of 9 IVO™ 4" Round Downlight New Construction UL924 Sequence of Operation The below information applies to all nLight AIR devices with an EM option. •EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds. •Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts. •Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing.NLIGHTSingle Lighting Controls Platform for Indoor & Outdoor Spaces nLight® is your networked lighting controls platform, for indoor and outdoor applications, providing wired or wireless options. Scaling from room to campus-wide applications, it is the one platform that grows with your business today and tomorrow; to seamlessly address energy cost optimization, building code compliance, improved occupant comfort, and much more. nLight also interfaces with DALI®, BACnet®, DMX and additional third-party devices. nLightcontrols.com Wired Embedded Controls 1. Install the luminaires with embedded controls 2. Install the nLight Wired wall switch 3. Connect the luminaires using standard CAT-5e cables and the controls devices will automatically discover each other and work (plug and play) CAT-5e nLight nPODMA DX NH NH NH Wireless Embedded Controls 1. Install the luminaires with embedded controls 2. Install the nLight AIR battery-powered wall switch 3. Use CLAIRITY+ mobile app to pair the fixtures with the wall switch and if desired, customize the sensor settings IVO SeriesIVO Series nLight rPODBA 2P DX NH NH NH Mobile Device IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D1 GOTHAM IVO4 D 20LM 35K 80CRI MWD MIN10 MVOLT ZT NCH P AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 1 of 10 Luminaire Type: Catalog Number: Flanged Flangeless Flangeless in Millwork •Tool-free aiming and locking with 0° - 40° Tilt and 365° Rotation •Compact 4.5" tall housing ideal for congested plenum spaces •Center Beam Candle Power up to 23,887 cd •Low visibility interior finish for quiet appearance •Perfect Color™ consistency within 1/2-step MacAdam Ellipse •Center-beam aiming through the aperture for maximum efficiency and minimal trim flash •Exceptional color rendering with 80 CRI, 90 CRI, or 95 CRI minimum •Accepts up to 2 accessory lenses •90% lumen maintenance at 55,000 hours •Wet Location optional, covered ceiling •Shower Trim, IP65 Rated, Dead Front available •Clean beams with soft transition from narrow spot up to wide flood distributions •Field changeable optics available every 5° Feature Set IVO 4" Round Product Family IVO™ 4" Round Adjustable New Construction Superior Perfomance* Nominal Lumens 05LM 07LM 10LM 15LM 20LM 25LM 30LM Delivered Lumens 526 762 1001 1557 2049 2726 3255 Wattage 5.1 7.8 10.6 16.5 22.8 27.7 34.3 Lumens per Watt 103 98 94 95 90 98 95 *Based on 35K/80, 35D, AC20, AR LSS Distribution / Beam AnglesTRIM STYLES AND COLORSPRODUCT FAMILYQUICK SPECIFICATIONSReflector ColorsFlange Styles New construction housing shown. Please see page 6 for full set of dimensional drawings. 4.5" x 11.8" x 15.8" "Angle Cut Bevel Clear Alzak Gold Pewter Wheat Black White White Anti‑Microbial Soft White Bronze 45°30°10°15°20°25°35°40°50°60°55° Downlight Lensed WW Surface Cylinder Pendant Cylinder Wall Cylinder Wall Adjustable Cylinder IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR NO EXCEPTIONS TAKEN By: Date: Meyer, Scherer & Rockcastle, LTD MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEM REJECTED REVISE AND RESUBMIT 4 8/5/2026Mitch RECEIVED Checking is only for general conformance with thedesign concept of the project and general compliancewith the information given in the Contract Documents.Any action shown is subject to the requirements of theplans and specifications. Contractor is responsible for:Dimensions and quantities which shall be confirmedand correlated at the job site; fabrication processesand techniques of construction; coordination of theirwork with that of all other trades and the satisfactoryperformance of their work. GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 2 of 10 IVO™ 4" Round Adjustable New Construction Luminaire Type: Catalog Number:ORDERING INFORMATIONEXAMPLE: IVO4 ADJ 10LM 35K 80CRI 20D MIN10 MVOLT ZT NCH AC AR LSS F Series Function Lumen Packages Kelvin Temperature Color Rendering Index Distribution IVO4 4" Round Recessed ADJ Adjustable 05LM 1 500 Lumens 07LM 750 Lumens 10LM 1000 Lumens 15LM 1500 Lumens 20LM 2000 Lumens 25LM 2500 Lumens 30LM 3000 Lumens 27K 2700K 30K 3000K 35K 3500K 40K 4000K 50K 5000K 80CRI 80+ CRI 90CRI2 90+ CRI 95CRI2 95+ CRI 10D3 10°30D 30°50D 50° 15D 15°35D 35°55D 55° 20D 20°40D 40°60D 60° 25D 25°45D 45° Dimming Level Voltage Control Input5 Emergency Option Housing Style MIN10 Min 10% Dim Level MIN1 Min 1% Dim Level DARK Min 0.1% Dim Level, Dim-to-Dark MVOLT Multi-Volt input, 120V-277V 120 120V input 277 277V input3474347V input ZT 6 Generic 0-10V EZT21 EldoLED 0-10V ELV7 Phase Dimming (Forward/Reverse) (120V only) DMX 8 DMX DALI 8 DALI-2 NLIGHT21 Embedded wired controls by nLight NLTAIR221 Embedded wireless controls by nLight NLIGHTER21 Embedded wired controls by nLight with UL924 listed emergency operation NLTAIREM221 Embedded wireless controls by nLight with UL924 listed emergency operation (Blank)No Emergency Pack E7WR9 IOTA 7W Emergency battery pack, Constant Power, Title 20 compliant, remote test switch. GTD20 Generator Transfer Device NCH Non-IC Housing (new construction only) ICAT IC/Airtight Housing (new construction only) 25LM max. CP Chicago Plenum CCEA Housing (new construction only) 25LM max. Options Trim Style Trim Lens12 Trim Color Trim Finish Flange Style SF Single Fuse, specify 120 or 277 WL10 Wet Location AC Angle Cut Reflector, recommended for 0° -40° tilt AC20 Angle Cut Reflector, recommended for 0° -20° tilt ABEV11 Bevel Trim ASH10,11 Shower/IP65 Bevel Trim (Deadfront) (blank)No Lens SLG Solite Lens CLR Clear Lens AR Clear Anodized BR Black Anodized GR Gold Anodized PR Pewter Anodized WTR Wheat Anodized WMR 13 Soft White Matte (painted) WRAMF 13 White Gloss with Anti-Microbial (painted) BZR 13,14 Dark Bronze (painted) TRALTBD 13,15 Trim RAL # (TBD for pricing only) TCPC Trim Custom Paint Color LD Matte Diffuse LS Specular LSS Semi Specular F Self Flanged (color matches trim) FL Flangeless (Drywall) FLM 16 Flangeless Millwork FBL 17 Flange Only Black FWR 18 Flange Only White FRALTBD 15 Flange Only RAL FCPC Flange Only Custom Paint Color ORDERING NOTES 1. 05LM only available with ELV or ZT. Not available with 347. 2. 90CRI not available with 50K, 95CRI not available with 35K, 40K, or 50K. 3. 10D available up to 20LM max. 4. 347 only available with ZT at MIN1 or MIN10. Not available with nLight, Emergency options, or 05LM. 5. Refer to Tech-240 for compatible dimmers. 6. ZT not available with DARK. 7. ELV only available with MIN1. 8. DMX and DALI only available with DARK. DMX and DALI with ICAT or CP available up to 20LM max. 9. E7WR not available with 20LM. 10. Trim lens required for WL or ASH trim. 11. ABEV and ASH trims not available with LS Trim Finish. 12. Trim lens optional for AC, AC20, or ABEV trim. 13. WMR, WRAMF, BZR, and TRALTBD not available with Trim Finish 14. BZR uses Corrosion Resistant Powder Coat. 15. For TRALTBD replace TBD with applicable RAL number and finish when ready to order. See RAL BROCHURE for available color options. 16. FLM requires Millwork Ceiling Cutout Template accessory, IVO4FLMKIT. Millwork Router Bit accessory, IVOFLMBIT, is optional or use similar. Millwork Adapter is included. 17. FBL not applicable with BR, FL, or FLM option. 18. FWR not applicable with WMR, FL, or FLM option. 19. FRALTBD not applicable with WMR, WRAMF, FL, or FLM option. 20. GTD not available with CP. Above ceiling access only. 21. EZT or nLight with ICAT or CP housings available up to 20LM max. IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 3 of 10 IVO™ 4" Round Adjustable New Construction ACCESSORIES — order as separate catalog numbers (shipped separately) IVO4FLMKIT IVO 4" Round Flangeless in Millwork Ceiling Cutout Template (min. 1 required per install) IVOFLMBIT IVO Flangeless in Millwork Straight Router Bit, ¼" Shank with Bearing (optional) IVO4OPTC D 10D U Field Replaceable 4" Downlight Optic, 10° IVO4OPTC D 15D U Field Replaceable 4" Downlight Optic, 15° IVO4OPTC D 20D U Field Replaceable 4" Downlight Optic, 20° IVO4OPTC D 25D U Field Replaceable 4" Downlight Optic, 25° IVO4OPTC D 30D U Field Replaceable 4" Downlight Optic, 30° IVO4OPTC D 35D U Field Replaceable 4" Downlight Optic, 35° IVO4OPTC D 40D U Field Replaceable 4" Downlight Optic, 40° IVO4OPTC D 45D U Field Replaceable 4" Downlight Optic, 45° IVO4OPTC D 50D U Field Replaceable 4" Downlight Optic, 50° IVO4OPTC D 55D U Field Replaceable 4" Downlight Optic, 55° IVO4OPTC D 60D U Field Replaceable 4" Downlight Optic, 60° IVO4 HEXCELL LOUVER Hexcell Louver 4", Optic Accessory IVO4 ELLIPTICAL LENS 60 X 15 60° x 15° Elliptical Lens 4", Optic Accessory IVO4 ELLIPTICAL LENS 60 X 30 60° x 30° Elliptical Lens 4", Optic Accessory IVO4 ACCESSORY HOLDER 4" Accessory Holder (included) HBTL 25" Tru-Lock Mounting Bar for 2-foot Grid Ceilings (pair) IVO C-CHANNEL 28" C-Channel (pair) IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 4 of 10 IVO™ 4" Round Adjustable New Construction DIMENSIONAL DATA •Dimensions in inches [millimeters] are overall width and height (including mounting hardware Butterfly Brackets / Hanger Bars), length excludes extendable Hanger Bars. •½" clearance on all sides from non‑combustible materials for non‑IC applications required, unless marked spacing is noted otherwise. •nLight Air Antenna extends 1.5" off the end of the j‑box (lengthwise). •Ceiling cutout for Flanged Trim is 5.13", ceiling cutout for Flangeless Trim is 5.25". •Fixture with Marked Spacing require the following clearances (min): 24" center‑to‑center, 12" center to side building member, 2" overhead to building member •Hanger Bars are extendable from 8.5" to 24". New Construction Dimensions Non-IC Housing (NCH)For 05LM to 30LM 4.5" [114mm] height 0.5"[12.7mm] collar depth7.3"[184mm] center of aperture 15.8"[401mm] length 2x1.5"[28.1mm] butterfly bracket 11.8"[300mm]width IC Rated Housing (ICAT)For 05LM to 25LM 4.5" [114mm] 0.5"[12.7mm] 7.3"[184mm] 15.8"[401mm]2x1.5"[28.1mm] 11.8"[300mm] Chicago Plenum Housing (CP)For 05LM to 25LM 4.5" [114mm] 0.5"[12.7mm] 7.3"[184mm] 15.8"[401mm]2x1.5"[28.1mm] 11.8"[300mm] Non-IC Housing (NCH)with E7WR Emergency Battery 4.5" [114mm] 0.5"[12.7mm]7.3"[184mm] 16.8"[426mm]2x1.5"[28.1mm] 11.9"[301mm] Non-IC Housing (NCH)with Generator Transfer Device (GTD) 4.5" [114mm] 0.5"[12.7mm]7.3"[184mm] 15.8"[401mm]2x1.5"[28.1mm] 13.9"[353mm] IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 5 of 10 IVO™ 4" Round Adjustable New Construction TRIM OPTIONSTrim Style and Flange Option •Dimensions in inches [millimeters] Trim Color Optical Finish Angle Cut (0°‑40°) Flanged (AC) (F) Angle Cut (0°‑20°) Flanged (AC20) (F) Bevel Flanged (BEV) (F) Clear Anodized(AR) Wheat Anodized (WTR) Semi-Specular(LSS) Angle Cut (0°‑40°) Flangeless (AC) (FL) Angle Cut (0°‑20°) Flangeless (AC20) (FL) Bevel Flangeless (BEV) (FL) Soft WhiteMatte Painted(WMR) Dark Bronze Gloss Painted(BZR) Specular(LS) Angle Cut (0°‑40°) Flangeless Millwork (AC) (FLM) Angle Cut (0°‑20°) Flangeless Millwork (AC20) (FLM) Bevel Flangeless Millwork (BEV) (FLM) Angle Cut (0°‑40°) Solite Lens Flanged (AC) (SLG) (F) Angle Cut (0°‑20°) Solite Lens Flanged (AC20) (SLG) (F) Bevel Solite Lens Flanged (BEV) (SLG) (F) Angle Cut (0°‑40°), best for hiding fixture interior Angle Cut (0°‑20°), best for maximum output, shallow tilt Bevel, black baffle hides fixture interior Black Anodized (BR) WhiteGloss Painted(WR) Matte Diffuse(LD) Gold Anodized (GR) White Anti‑MicrobialGloss Painted(WRAMF) Pewter Anodized (PR) Note: These colors were carefully reproduced to give as true a depiction as possible of the finished product color. Some colors, however, may vary slightly from actual appearance due to display/printing variations and limitations. Please contact a Gotham representative for an Architectural Color Chip Kit (GCOLORS KIT), consisting of Powder-Coated and Plated Finishes. Parabolic Flanged shown. Clear Anodized shown. BB 512"14.0 414"10.8 11316"4.6 BB 11516"4.9 512"14.0 4 716"11.3 CC 458"11.7 512"14.0 2 116"5.2 IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 6 of 10 IVO™ 4" Round Adjustable New Construction FEATURESTilt •Lockable tilt from 0°‑40° (tool‑free) maintains center‑beam through the aperture for maximum efficiency and minimal trim flash Rotation •Lockable rotation 0°‑365° (tool‑free) ensures no dead‑spots when aiming Field Changeable Optics •Twist and lock swappable optics allow for easy beam angle adjustment in the field (example below) Accessory Lenses •Accessory holder accepts up to two lenses (example below) •Available lenses include: Hexcell and Elliptical Center‑beam maintained through aperture over tilt angles Rotation 0°‑365° Hexcell Louver Elliptical Lens Accessory Lens Holder Rotation lever, locked Rotation lever, unlocked Adjustable fixture aimed at 0°, tilt lever unlocked Adjustable fixture aimed at 0°, tilt lever locked Adjustable fixture aimed at 20°, tilt lever locked Adjustable fixture aimed at 40°, tilt lever locked IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 7 of 10 IVO™ 4" Round Adjustable New Construction TABLES OF USEFLANGELESSDimming ConfigurationsDimming Level Control Input Dimming Level Driver Dim Curve Recommended Control Dim Curve MIN10 +ZT 100% to 10%Linear Linear/Logarithmic +EZT 100% to 10%Linear Linear/Logarithmic MIN1 +ZT 100% to 1%Linear Linear/Logarithmic +EZT 100% to 1%Linear Linear/Logarithmic +ELV 100% to 1%*n/a n/a DARK +EZT 100% to 0.1%Logarithmic Linear +DMX 100% to 0.1%Square Linear +DALI 100% to 0.1%Logarithmic Linear Embedded Nlight ConfigurationsDimming Level Control Input Dimming Level Control Provided Driver Provided MIN10 +NLIGHT 100% to 10%NIO EZDXA eldoLED ECOdrive +NLIGHTER 100% to 10%NIO EZDCL ER eldoLED ECOdrive +NLTAIR2 100% to 10%RIO EZDL G2 eldoLED ECOdrive +NLTAIREM2 100% to 10%RIO EZDL EM G2 eldoLED ECOdrive MIN1 +NLIGHT 100% to 1%NIO EZDXA eldoLED ECOdrive +NLIGHTER 100% to 1%NIO EZDCL ER eldoLED ECOdrive +NLTAIR2 100% to 1%RIO EZDL G2 eldoLED ECOdrive +NLTAIREM2 100% to 1%RIO EZDL EM G2 eldoLED ECOdrive DARK +NLIGHT 100% to 0.1%NIO EZDXA eldoLED SOLOdrive +NLIGHTER 100% to 0.1%NIO EZDCL ER eldoLED SOLOdrive +NLTAIR2 100% to 0.1%RIO EZDL G2 eldoLED SOLOdrive +NLTAIREM2 100% to 0.1%RIO EZDL EM G2 eldoLED SOLOdrive * ELV Minimum Dimming level depends on dimmer and dimmer load Flangeless Installation Gotham’s flangeless option utilizes a micro‑thin polymer mud ring that minimizes the amount of drywall compound required to finish the ceiling. The end result is a virtually undetectable flangeless downlight installation. The polymer mud ring is installed independent of the of the recessed frame, therefore floating with the ceiling. This innovation minimizes any surface cracks during reflector installation, ceiling movement and any future service to the recessed frame, wiring, electronics, etc. Flangeless Millwork Installation IVO’s Flangeless in Millwork solution makes installation easy and precise. First, cut a hole in the Wood Ceiling using the Millwork Cutout Template (sold separately). Second, once Housing and ceiling are mounted in place, insert sheet metal Millwork Adapter (provided) lining up edge of tab with bottom of ceiling. Third, secure in place using finishing nails (provided) then remove tabs from Millwork Adapter. Last, install Trim! Partially finished mud ring, showing cross‑section detail. Insert Millwork Adapter into precision‑cut hole. An IVO downlight requires only approximately 3" of plaster to finish. Secure with finishing nails. IVO with flangeless trim Insert Trim and Module. How to Estimate Delivered Lumens in Emergency Mode Delivered Lumens = 1.25 x P x LPW P = Output Power/Wattage of Emergency Battery Driver (E7WR* = 7W, E10WR* = 10W, E15WR* = 15W) LPW = Lumen per Watt rating of luminaire based on Ordering Code selections IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 8 of 10 IVO™ 4" Round Adjustable New Construction SPECIFICATIONSOptical System •Bounding Ray™ optical design delivers low brightness apertures for a comfortable lighting experience and ensures no source image up to cut‑off angle, minimizing glare. •Clean beams with soft transitions from narrow spot up to wide flood distributions with optics available every 5° •Optics are field changeable (tool‑free). •Accepts one Hexcell Louver plus one additional Optic Accessory (Elliptical Lens). LED Light Engine •Perfect Color™ consistency within ½‑step MacAdam Ellipse using proprietary pick and place algorithm •90% lumen maintenance at 55,000 hours. •Available in 80, 90, or 95 CRI. 90CRI has R9 greater than 50, 95 CRI has R9 greater than 80. Trims •Trims are field changeable. •Trims are available in 9 colors and 3 surface finishes (standard) •Custom RAL and Paint colors available upon request. •Trim lenses are made of Tempered Glass. Electrical •120, 277, 347, or Multi‑Volt (MVOLT) 120‑277 VAC input at 50/60 Hz •Power Factor > 85% •Input wires 18 AWG, 600V minimum, copper •Fixtures are ROHS compliant EMI/RFI •EMI/RFI per FCC Title 47 CFR, Part 15, Class A rated standard. Controls (Optional) •Luminaire can be equipped with interface for nLight wired, allowing it to communicate over an nLight network. Couple with nLight‑enabled sensors, power packs, or WallPods using CAT‑5 cabling to create an nLight Control Zone. Link Control Zone to a Gateway directly or via a Bridge for remote status monitoring and control using SensorView software. •Luminaire can be equipped with interface for nLight Air, allowing it to communicate over the wireless nLight control platform. Can be paired to other luminaires and wall switches through CLAIRITY+, a mobile app, which allows individual fixture control. Dimming •Luminaire Is capable of continuous dimming without perceivable flicker (stroboscopic) as measured by flicker index (ASNI/IES RP‑16‑10). •Available dimming ranges include: 100%‑10% (MIN10), 100%‑1% (MIN1), and 100%‑0.1% (DARK) of rated lumen output. •Available with smooth shut off function from minimum dimming level to 0%. •EldoLED drivers (EZT, DALI) conform to IEEE P1789 standards. •Drivers are inaudible in 24dB environment and stable even when input voltage conditions experience typical commercial environment fluctuations. Emergency Battery (Optional) •Luminaires equipped with battery pack (E7WR) comply with NFPA 101 (Life Safety Code) and deliver constant light output for a duration of 90 minutes minimum with AC power loss. •Emergency battery is CEC T20 compliant. Installation •Stamped Spring Clips allow tool‑free Trim installation and servicing. •Compatible with 1/2" to 1‑1/8" ceiling thicknesses. Construction •Access to Light Engine, Driver, and branch circuit conductors is available from below the ceiling without the use of tools. •Universal Mounting Butterfly Brackets can adjust vertically 2.5" and accept various mounting bars including ¾" and 1‑1/2" C Channel, ½" or ¾" Flat Strap, ½" Conduit, and ½" Angle Bars, as well as standard Hanger Bars (included). •Hanger Bars are extendable from 8.5" to 24". •Luminaire is constructed with 20 gauge min cold‑rolled steel, galvanized steel, and aluminum. •Hanger Bar or C‑Channel accessories available Listings •Fixtures are CSA certified to meet US and Canadian standards. •Fixtures are NOM certified to meet Mexican standards •All fixtures are manufactured in strict accordance with the appropriate and current requirements of the "Standards for Safety" per UL. •Damp Location standard. •Wet Location available, covered ceiling. Photometrics •All photometry is conducted by IESNA standard LM‑79‑08 in an accredited lab. •LEDs are tested to LM‑80 standards. Lumen maintenance is calculated via TM‑21. Warranty •5‑year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms‑and‑conditions Note: •Actual performance or Life calculations may differ as a result of end‑user environment and application. •All values are design or typical values, measured under laboratory conditions at 25 °C. •The product images shown are for illustration purposes only and may not be an exact representation of the product. Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provided consistent color appearance and out‑of‑the‑box control capability with simple commissioning when used with Acuity Brands controls products. All configurations of this luminaire are calibrated and tested meet the Acuity Brands' specification for chromatic consistency ‑ including color rendering, color fidelity and color temperature tolerance around standard CIE chromaticity coordinates. To learn more about A+, visit www.acuitybrands.com/aplus. IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 9 of 10 IVO™ 4" Round Adjustable New Construction PHOTOMETRY15 Degree Beam 35 Degree Beam 45 Degree Beam IVO4 ADJ 20LM 35K 80CRI 15D AC20 AR LSS IVO4 ADJ 20LM 35K 80CRI 35D AC20 AR LSS IVO4 ADJ 20LM 35K 80CRI 45D AC20 AR LSS Wattage: 22.8, Lumens: 2023, LPW: 89, S/MH: .24 Wattage: 22.4, Lumens: 2019, LPW: 88, S/MH: .27 Wattage: 22.8, Lumens: 2003.2, LPW: 88,S/MH: .33 Trim Color and Finish Multiplier Trim Color Trim Finish Multiplier AR LSS 1.00 AR LS 1.00 AR LD 0.99 BR LSS 0.96 BR LS 0.96 BR LD 0.96 GR LSS 0.99 GR LS 0.99 GR LD 0.99 PR LSS 0.99 PR LS 0.98 PR LD 0.97 WTR LSS 1.00 WTR LS 1.00 WTR LD 1.00 WR LSS 1.01 WRM LSS 1.01 WRAMF LD 1.01 BZR LSS 0.96 Zonal Lumen Summary Zone Lumens % 0-30 1868.8 92.4% 0-40 1970.4 97.4% 0-60 2015 99.6% 0-90 2022.4 100% Zonal Lumen Summary Zone Lumens % 0-30 1863 92.3% 0-40 1966 97.4% 0-60 2011 99.6% 0-90 2018.5 100% Zonal Lumen Summary Zone Lumens % 0-30 1838.5 91.8% 0-40 1947.8 97.2% 0-60 1994.6 99.6% 0-90 2002.4 100.0% Cone of Light Mounting Height Initial FC Center Beam Beam Diameter (ft) Horizontal Vertical 8' 331.21 1.9 1.9 10'211.98 2.4 2.4 12'147.21 2.9 2.9 14'108.15 3.4 3.4 16'82.8 3.9 3.8 Cone of Light Mounting Height Initial FC Center Beam Beam Diameter (ft) Horizontal Vertical 8' 249.79 2.3 2.2 10'159.86 2.9 2.8 12'111.02 3.4 3.4 14'81.56 4 3.9 16'62.45 4.6 4.5 Cone of Light Mounting Height Initial FC Center Beam Beam Diameter (ft) Horizontal Vertical 8' 170.12 2.8 2.8 10'108.87 3.6 3.4 12'75.61 4.3 4.1 14'55.55 5 4.8 16'42.53 5.7 5.5 Candela Summary 0°21198 10°4884 20°824 30°29 40°9 50°0 60°0 70°0 80°0 90°0 Candela Summary 0°15986 10°5319 20°949 30°33 40°11 50°1 60°0 70°0 80°0 90°0 Candela Summary 0°10887 10°5260 20°1174 30°30 40°10 50°1 60°0 70°0 80°0 90°0 Lumen Multiplier to 20LM 05LM 0.26 07LM 0.37 10LM 0.49 15LM 0.76 20LM 1.00 25LM 1.33 30LM 1.59 Polar Candela Distribution 22,000 18,333 14,667 11,000 7,333 3,667 0.00 3,667 7,333 11,000 14,667 18,333 22,000 VA:0°10°20°30°40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°150°160°170°180° - 0° H - 90° H Polar Candela Distribution 16,000 13,333 10,667 8,000 5,333 2,667 0.00 2,667 5,333 8,000 10,667 13,333 16,000 VA:0°10°20°30°40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°150°160°170°180° - 0° H - 90° H Polar Candela Distribution 11,000 9,167 7,333 5,500 3,667 1,833 0.00 1,833 3,667 5,500 7,333 9,167 11,000 VA:0°10°20°30°40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°150°160°170°180° - 0° H - 90° H CRI/CCT Multiplier Table CRI CCT Multiplier 80 2700K 0.92 3000K 0.96 3500K 1.00 4000K 1.01 5000K 1.04 90 2700K 0.80 3000K 0.85 3500K 0.85 4000K 0.89 95 2700K 0.68 3000K 0.75 Trim Type Multiplier AC 0.90 AC20 1.00 ABEV 0.78 Lens Mutliplier None 1.00 SLG 0.95 CLG 0.93 IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR GOTHAM ARCHITECTURAL DOWNLIGHTING | 1 Acuity Way, Decatur, GA 30035 | P 800-705-SERV (7378) | gothamlighting.com © 2025 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 11/07/25 Specifications subject to change without notice. IVO4-ADJpage 10 of 10 IVO™ 4" Round Adjustable New Construction UL924 Sequence of Operation The below information applies to all nLight AIR devices with an EM option. •EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds. •Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts. •Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing.NLIGHTSingle Lighting Controls Platform for Indoor & Outdoor Spaces nLight® is your networked lighting controls platform, for indoor and outdoor applications, providing wired or wireless options. Scaling from room to campus-wide applications, it is the one platform that grows with your business today and tomorrow; to seamlessly address energy cost optimization, building code compliance, improved occupant comfort, and much more. nLight also interfaces with DALI®, BACnet®, DMX and additional third-party devices. nLightcontrols.com Wired Embedded Controls 1. Install the luminaires with embedded controls 2. Install the nLight Wired wall switch 3. Connect the luminaires using standard CAT-5e cables and the controls devices will automatically discover each other and work (plug and play) CAT-5e nLight nPODMA DX NH NH NH Wireless Embedded Controls 1. Install the luminaires with embedded controls 2. Install the nLight AIR battery-powered wall switch 3. Use CLAIRITY+ mobile app to pair the fixtures with the wall switch and if desired, customize the sensor settings IVO SeriesIVO Series nLight rPODBA 2P DX NH NH NH Mobile Device IVO™ BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: D2 GOTHAM IVO4 ADJ 20LM 35K 80CRI 30D MIN1 MVOLT ZT NCH AC AR LSS FWR www.ScottArchLighting.com | Tel (707) 864-2172 | Fax (707) 864-2182 © Copyright 2025 Scott Architectural Lighting. All Rights Reserved. Made in the USA. DIMENSIONS  H Dia X Recommended LampSize (By Others)BASE MODEL NO. 60″6″6″A15 S2C20-1N05 60″8″8″A19 S2C21-1N10 60″10″10″A19 S2C22-1N10 60″12″12″A21 S2C23-1N15 60″14″14″A21 S2C24-1N15 SPECIFICATIONS Voltage: 120V Only Mounting: Mounts to all Standard Electrical Junction Boxes (by others) With Hardware Provided. FEATURES • 6-14″ Opal Diffuser (Standard) • Skull Cap Top • Black SJ Cord • E26 Socket for LED Lamp (By Others) ORDER AS A COMPLETE UNIT: Model No. + Lamp Code + Finish Code + Option Code S2C20-1N05 +PT +OA +Option S2C21-1N10 XT S2C22-1N10 PF S2C23-1N15 S2C24-1N15 FINISHES PT Powder Coated Finishes* XT Trending Brushed Metal Finishes* PF Pure Metal Finishes* *(Specify Color Code from the list of Finishes – ie. Gold Touch would be ‘GT’) OPTIONS CAG – Clear Acrylic Globe WH0 – White Cord SB0 – Silver Braided Cord S2C20 Series KUGEL BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: G1 SAL S2C20-1N05-FINISH-OAH NO EXCEPTIONS TAKEN By: Date: Meyer, Scherer & Rockcastle, LTD MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEM REJECTED REVISE AND RESUBMIT 4 8/5/2026Mitch RECEIVED Checking is only for general conformance with thedesign concept of the project and general compliancewith the information given in the Contract Documents.Any action shown is subject to the requirements of theplans and specifications. Contractor is responsible for:Dimensions and quantities which shall be confirmedand correlated at the job site; fabrication processesand techniques of construction; coordination of theirwork with that of all other trades and the satisfactoryperformance of their work. STARMED MUS UNDERCABINET SERIESTM New Star Lighting 2225 W Pershing Rd, Chicago, IL 60609 (773) 847-1400 www.newstarlighting.com Specifications and dimensions are subject to change without notice. For additional options and dimensional details, please consult your New Star Lighting representative. © 2026, New Star Lighting. All rights reserved. Unauthorized duplication or distribution is prohibited. 1 06042026 ORDERING INFORMATION Example: MUS2-HC-L135-90C-A-UN-DM PROJECT: TYPE: PRODUCT: APPROVED BY: PRODUCT FEATURES • Intended for Task Lighting, Patient Rooms, Nurse Stations, Medical Offices, Research Facilities, Laboratories, and more • Available in three sizes: 1ft, 18in, 2ft, 3ft and 4ft • Easy installation with keyhole slots • White antimicrobial finish standard • Fixture is certified to UL standard by Intertek Testing Laboratory for Damp Locations • This product is Made in America and complies with the Buy American Act (BAA) and the Build America Buy America Act (BABAA) MUS MUS L1 Series Size* 1 = 1ft 18 = 18in 2 = 2ft 3 = 3ft 4 = 4ft *Nominal Size. Dimensional Data on Page 2. Housing HC = 20Ga. CRS Painted HA = 16Ga. Alum. Painted Lumen Output* L1 = Standard *Subject to change. Performance data on Page 2. Color Temp. 30 = 3000K 35 = 3500K 40 = 4000K 50 = 5000K A DM CRI 80C = 80 CRI 90C = 90 CRI Lens A = .125 Prismatic Acrylic Voltage 12 = 120V 27 = 277V UN = Universal (120V-277V) Driver DM = 0-10V dimming with 10-100% range Options FZ1 = Fuse (120V) FZ2 = Fuse (277V) RM = Row Mount (consult factory) RS = Rocker Switch (120V) CO = Convenience Outlet (120V) OC = Occupancy Sensor BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: U1 NEWSTAR LIGHTING MUS-3-HC-L1-35-80CRI-DM-RS STARMED MUS UNDERCABINET SERIESTM New Star Lighting 2225 W Pershing Rd, Chicago, IL 60609 (773) 847-1400 www.newstarlighting.com Specifications and dimensions are subject to change without notice. For additional options and dimensional details, please consult your New Star Lighting representative. © 2026, New Star Lighting. All rights reserved. Unauthorized duplication or distribution is prohibited. 2 06042026 SPECIFICATIONS HOUSING: 20-Gauge formed cold rolled steel housing with continuous seam welds and ground smooth. Aluminum option available. LENS: .125” prismatic acrylic lens. LED: Available in three color temperatures 3000K, 3500K and 4000K with maximum 3-step MacAdam variation allowance. Other color temperatures available, consult factory. Minimum 50,000 hours with 70% lumen maintenance in a 25°C ambient temperature environment, compliant with IES LM-80 testing standards. ELECTRICAL: 120/277VAC 50/60HZ standard integral 0-10V dimming driver available with 10-100% range. FINISH: White antimicrobial polyester powder coat finish following multi-stage iron phosphate pretreatment. INSTALLATION: Surface installation. Keyhole slots for easy installation. Mounting screws are not provided. WARRANTY: 5 Year Warranty. LABEL: Fixture is certified to UL standards by Intertek Testing Laboratory for Damp Location.This product was Made in America and complies with the Buy American Act (BAA). DIMENSIONAL DATA PERFORMANCE DATA* *LEDs are frequently updated therefore values may change without notice. 5.00” 5.00” MUS2 22.50” 46.12” 1.25” 2.81” 11.25” 6.06” 10.38” 22.50” 2X ø 0.25” KEY SLOT 3X ø .625x.58 DD K.O MUS4 1.16” 5X ø .625x.58 DD K.O 17.00” 17.00” 6.06” 6.06” 34.00” 46.12” 2X ø 0.25” KEY SLOT 1.25” 2.81” 5.00” 1.16” 5.91” 6.06” 22.19” 34.31” 11.25” 11.25” 2X ø 0.25” KEY SLOT 5X ø .625x.58 DD K.O 1.25” 2.81” 34.31” 5.00” MUS3 MODEL OUTPUT COLOR TEMP.LUMENS DELIVERED EFFICACY (lm/W)INPUT POWER (W) MUS1 L1 = Standard 4000K 625 100 6 MUS18 L1 = Standard 4000K 937 100 9 MUS2 L1 = Standard 4000K 1250 100 12 MUS3 L1 = Standard 4000K 1875 100 18 MUS4 L1 = Standard 4000K 2500 100 25 BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: U1 NEWSTAR LIGHTING MUS-3-HC-L1-35-80CRI-DM-RS www.ScottArchLighting.com | Tel (707) 864-2172 | Fax (707) 864-2182 © Copyright 2026 Scott Architectural Lighting. All Rights Reserved. Made in the USA. DIMENSIONS  Dia H BASE MODEL NO. 8″6 1/2″S7240-L1012″11″S7241-L10 18″16 3/4″S7242-L1622″20 5/8″S7243-L24 SPECIFICATIONS Driver: REMOTE Mounted 0-10V dimming to 1%, 120/277 Mounting: Mounts to all Standard Electrical Junction Boxes (by others) With Hardware Provided. FEATURES • Opal Matte Acrylic Diffuser • LED 0-10V Dimming Driver ORDER AS A COMPLETE UNIT: Model No. + Lamp Code + Finish Code + OA + Option Code S7240-L10 +27K +OptionS7241-L10 30K S7242-L16 35KS7243-L24 40K OPTIONS EML Remote 10W Emergency LED Battery Backup (Requires Additional Power Cable) LIGHT OUTPUT LXX = ~ 119 LPW Delivered Lumens (Example: L10= 10W x 119LPW = 1,190 Lumens) S7240 Series PALLA THIS WILL BE MODIFIED TO BE A WALL SCONCE BOZEMAN LIBRARY CHILDREN'S ROOM FIXTURE: V1 SAL S27240-L10-35-FINISH NO EXCEPTIONS TAKEN By: Date: Meyer, Scherer & Rockcastle, LTD MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEM REJECTED REVISE AND RESUBMIT 4 8/5/2026Mitch RECEIVED Checking is only for general conformance with thedesign concept of the project and general compliancewith the information given in the Contract Documents.Any action shown is subject to the requirements of theplans and specifications. Contractor is responsible for:Dimensions and quantities which shall be confirmedand correlated at the job site; fabrication processesand techniques of construction; coordination of theirwork with that of all other trades and the satisfactoryperformance of their work. Carly Svenvold, PEx08/04/26X8/4/2026