Loading...
HomeMy WebLinkAbout038 - L2.01 Schedule & Notes1.THE CONTRACTOR IS TO INSTALL AN AUTOMATIC IRRIGATION SYSTEM THAT WILL PROVIDE 100% COVERAGE FOR ALL LANDSCAPED AREAS.2.REFER TO DETAILS FOR INSTALLATION INSTRUCTIONS.3.MEET ALL APPLICABLE LOCAL AND MUNICIPAL CODES FOR WORK NECESSARY IN IRRIGATION SYSTEM INSTALLATION.4.THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, AND USE/SALES TAXES APPLICABLE TO THIS PROJECT.5.VERIFY ALL SITE INFORMATION PRIOR TO CONSTRUCTION.6.NOTIFY OWNER/LANDSCAPE ARCHITECT OF ANY DISCREPANCIES FROM PREPARED IRRIGATION PLANS.7.LOCATE ALL UNDERGROUND UTILITIES PRIOR TO BEGINNING OF WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO UNDERGROUND UTILITIESCAUSED BY INSTALLATION OF IRRIGATION SYSTEM.8.CONTRACTOR IS TO REFER TO AND COORDINATE IRRIGATION SYSTEM INSTALLATION WITH LANDSCAPE PLANS. AVOID CONFLICTING LOCATIONS BETWEENPIPING AND LANDSCAPE MATERIAL, EDGING, ETC.9.TAP LOCATION ON PLAN IS SCHEMATIC, CONTRACTOR IS TO VERIFY LOCATION AND COORDINATE WITH OWNER AND ALL OTHER DISCIPLINES.10.CONTRACTOR IS TO PROVIDE ALL NECESSARY PIPE, VALVES, ETC. DOWNSTREAM FROM POINT OF CONNECTION NOT INSTALLED BY OTHER DISCIPLINES.11.CONTRACTOR IS TO VERIFY AVAILABLE PRESSURE AND FLOW AT POINT OF CONNECTION PRIOR TO INSTALLATION OF IRRIGATION SYSTEM EQUIPMENT ANDNOTIFY LANDSCAPE ARCHITECT WITH VERIFICATION FIGURES. FAILURE TO NOTIFY LANDSCAPE ARCHITECT WILL RESULT IN CONTRACTOR TAKINGRESPONSIBILITY FOR ANY ALTERATIONS TO THE PLAN DUE TO VARIATIONS OF PRESSURE OR FLOW AT HIS/HER OWN RISK.12.INSTALL MANUAL DRAIN VALVES AT ALL LOW POINTS TO ALLOW FOR SYSTEM WINTERIZATION.13.CONTRACTOR TO COORDINATE INSTALLATION OF SLEEVING WITH BUILDING CONSTRUCTION AND INSTALLATION OF PAVING AND SIDEWALKS. ALL SLEEVINGUNDER PAVED SURFACES SHOWN ON PLANS IS BY CONTRACTOR UNLESS OTHERWISE NOTED. ALL MAINLINES, LATERAL LINES, DRIP LINES AND CONTROLWIRES UNDER PAVED SURFACES ARE TO BE INSTALLED IN SLEEVING. INSTALL SLEEVING AS PER DETAIL AND SPECIFICATIONS. ALL SLEEVING TO BE TWICETHE SIZE OF PIPING ROUTED THROUGH SLEEVE.14.ALL PIPING, PVC ELECTRICAL SLEEVES, ETC. UNDER PAVING SHALL BE INSTALLED PRIOR TO PAVING WORK. NO TEES, ELLS OR OTHER TURNS IN PIPING SHALLBE LOCATED UNDER PAVING EXCEPT WHERE SHOWN ON DRAWING. CAP ALL ENDS HAND TIGHT PRIOR TO BACKFILL USE PVC SCHEDULE 40 PIPE FOR ALLNON-PRESSURE LATERAL LINE PIPING INSTALLED UNDER PAVED AREAS.15.SPRINKLER HEADS MUST BE SPACED 2 INCHES MINIMUM FROM HARDSCAPE EDGES.16.OPERATING PRESSURE OF THE IRRIGATION SYSTEM MUST MEET MANUFACTURER’S RECOMMENDED OPERATING PRESSURE.17.CONTRACTOR IS TO PROVIDE ELECTRICAL POWER TO THE AUTOMATIC CONTROLLER. COORDINATE LOCATION WITH OWNER/LANDSCAPE ARCHITECT.18.CONTRACTOR SHALL EXTEND SPARE CONTROL WIRES FROM EACH CONTROLLER TO THE END OF THE MAINLINE SERVING THAT CONTROLLER. SEE DETAILSFOR NUMBER OF SPARE WIRES AND INSTALLATION REQ.19.INSTALL ALL MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL MALE PIPE THREADS ON ALL IRRIGATIONSWING JOINT AND VALVE ASSEMBLIES.20.ALL TRENCHES TO BE PUDDLED AND COMPACTED TO THE SAME DENSITY AS THE UNDISTURBED ADJACENT SOIL.21.CONTRACTOR TO PERFORM IRRIGATION AUDIT FOR IRRIGATION ZONES AS PART OF FINAL IRRIGATION ACCEPTANCE.22.IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED IN LANDSCAPED AREAS AND WITHIN THE PROPERTY LIMITS. ANYEQUIPMENT SHOWN OUTSIDE OF THESE LIMITS IS SHOWN IN THAT LOCATION FOR GRAPHICAL CLARITY ONLY. ALL VALVE BOXES SHALL BE INSTALLED AMINIMUM OF 2'-0" FROM EDGE OF ANY PAVED SURFACES. AND A MINIMUM OF 3'-0" FROM THE CENTERLINE OF ANY DRAINAGE SWALES.23.IF PROPOSED IRRIGATION SYSTEM IS CONNECTING TO AN EXISTING SYSTEM, CONTRACTOR IS RESPONSIBLE FOR TESTING AND VERIFYING BOTH EXISTINGAND NEW IRRIGATION SYSTEMS PROVIDE 100% COVERAGE.24.DRIP IRRIGATION MUST BE INSTALLED WITH THE ABILITY TO EASILY FLUSH THE LINE.GENERAL NOTESSYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYPSIDETAILHUNTER MP1000 PROS-06-PRS30-CVTURF ROTATOR, 6IN. POP-UP WITH CHECK VALVE,PRESSURE REGULATED TO 30 PSI, MP ROTATOR NOZZLEON PRS30 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHTBLUE 210 TO 270 ARC, O=OLIVE 360 ARC.730HUNTER MP2000 PROS-06-PRS30-CVTURF ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLEDCHECK VALVE, PRESSURE REGULATED TO 30 PSI, MPROTATOR NOZZLE ON PRS30 BODY. K=BLACK ADJ ARC90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC.630HUNTER MP3000 PROS-06-PRS30-CVTURF ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLEDCHECK VALVE, PRESSURE REGULATED TO 30 PSI, MPROTATOR NOZZLE ON PRS30 BODY. B=BLUE ADJ ARC90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC.1030HUNTER MP3500 PROS-06-PRS30-CVTURF ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLEDCHECK VALVE, PRESSURE REGULATED TO 30 PSI, MPROTATOR NOZZLE ON PRS30 BODY. LB=LIGHT BROWNADJUSTABLE ARC, 90-210.1330SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYDETAILNETAFIM LVCZ-150HPPRE-ASSEMBLED CONTROL ZONE KITS WITH 1-1/2IN.SERIES 80 CONTROL VALVE, 1-1/2IN. DISC FILTER AND1-1/2IN. HIGH FLOW PRESSURE REGULATOR. FLOWRANGE: 11-35 GPM. COMMERCIAL APPLICATION.1NETAFIM LVCZ-150HPPRE-ASSEMBLED CONTROL ZONE KITS WITH 1-1/2IN.SERIES 80 CONTROL VALVE, 1-1/2IN. DISC FILTER AND1-1/2IN. HIGH FLOW PRESSURE REGULATOR. FLOWRANGE: 11-35 GPM. COMMERCIAL APPLICATION.11NETAFIM TLDL-06-12 DRIP RING9AREA TO RECEIVE DRIPLINENETAFIM TLDL-06-12TECHLINE PRESSURE COMPENSATING LANDSCAPEDRIPLINE. 0.6 GPH EMITTERS AT 12" O.C. DRIPLINELATERALS SPACED AT 12" APART, WITH EMITTERS OFFSETFOR TRIANGULAR PATTERN. SURFACE AND SUB SURFACEINSTALLATIONS. UV RESISTANT.30,121 LFSYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYDETAILHUNTER ICV-G1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTECONTROL VALVES, GLOBE CONFIGURATION, WITH NPTTHREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPALUSE.3HUNTER HQ-44RCQUICK COUPLER VALVE, YELLOW RUBBER COVER, REDBRASS AND STAINLESS STEEL, WITH 1IN. NPT INLET,2-PIECE BODY.1GATE VALVE2" RESILIENT SEATED GATE VALVE2HUNTER ICV-G 2"1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC MASTERVALVE, GLOBE CONFIGURATION, WITH NPT THREADEDINLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE.1WILKINS BY ZURN ELKAY WATER SOLUTIONS 500XLLEAD-FREE WATER PRESSURE REDUCING VALVE WITHTHE HIGHEST FLOW RATE OF THE ENTIRE WILKINSREGULATOR LINE. BRONZE, UNION END CONNECTION,AVAILABLE IN 1/2IN. TO 3IN..1FEBCO 825Y 2"REDUCED PRESSURE BACKFLOW PREVENTER1HUNTER A2C-5400-M54-STATION CONTROLLER WITH SEVEN (7) A2M-600MODULES IN AN OUTDOOR GRAY STEEL WALL MOUNTENCLOSURE.1HUNTER SOIL-CLIKTHE SOIL-CLIK PROBE USES PROVEN TECHNOLOGY TOMEASURE MOISTURE WITHIN THE ROOT ZONE. WHEN THEPROBE SENSES THAT THE SOIL HAS REACHED ITSDESIRED MOISTURE LEVEL, IT WILL SHUT DOWNIRRIGATION, PREVENTING WATER WASTE.1HUNTER WSSWIRELESS SOLAR, RAIN FREEZE SENSOR WITH OUTDOORINTERFACE, CONNECTS TO HUNTER PCC, PRO-C, ANDI-CORE CONTROLLERS, INSTALL AS NOTED. INCLUDES 10YEAR LITHIUM BATTERY AND RUBBER MODULE COVER,AND GUTTER MOUNT BRACKET.1HUNTER HFS-200FLOW SENSOR FOR USE WITH ACC CONTROLLER, 2IN.SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP.1WATER METER 1-1/2"1IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 212,194 LFIRRIGATION MAINLINE: PVC SCHEDULE 401,532 LFPIPE SLEEVE: DUCTILE IRON PIPE - CLASS 52170.7 LF1000200030003500MBFCSoil ClickSolar SyncXXMValve NumberValve SizeValve FlowValve Callout###"IRRIGATION SCHEDULENUMBERMODELSIZETYPEGPMPSIPSI @ POCPRECIP1NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE25.5711.226.50.96 in/h2NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE25.8912.027.40.96 in/h3NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE29.5111.928.20.96 in/h4NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE25.0711.526.60.96 in/h5NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE34.1911.1290.96 in/h6NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE22.9711.225.40.96 in/h7NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE32.4611.227.30.96 in/h8NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE33.721127.00.96 in/h9NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE30.6911.126.70.96 in/h10NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE30.0911.527.50.96 in/h11HUNTER ICV-G1-1/2"TURF ROTARY3.232.544.70.36 in/h12NETAFIM LVCZ-150HP2"AREA FOR DRIPLINE13.6112.325.30.96 in/h13HUNTER ICV-G1"TURF ROTARY22.2839.854.30.2 in/h14HUNTER ICV-G1"TURF ROTARY20.6137.051.20.19 in/h15NETAFIM LVCZ-150HP1-1/2"DRIP RING1.2617.429.60.57 in/hVALVE SCHEDULETOTAL YEARLY WATER DEMAND FROM IRRIGATION 266,708 GALLONSBASED ON 26 WEEK WATERING SEASONWATERING SCHEDULE BASED ON AVERAGE WATERING WEEK, AND IS EXPECTED TO BE MORE OR LESSDEPENDING ON SEASONAL CONDITIONS.NUMBERMODELTYPEPRECIPSUNMONTUEWEDTHUFRISATIN./WEEKMIN./WEEKGAL./WEEKGAL./DAY1NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.332129598.52NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.33213151053NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.33214951654NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.33214291435NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.33217182396NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.33214821617NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.33216822278NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.33217082369NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.332164421510NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.332163221111HUNTER ICV-GTURF ROTARY0.36 in/h19 min19 min19 min0.335617959.812NETAFIM LVCZ-150HPAREA FOR DRIPLINE0.96 in/h7 min7 min7 min0.332128695.313HUNTER ICV-GTURF ROTARY0.2 in/h33 min33 min33 min0.33982,18472814HUNTER ICV-GTURF ROTARY0.19 in/h35 min35 min35 min0.331052,16472115NETAFIM LVCZ-150HPDRIP RING0.57 in/h12 min12 min12 min0.333544.114.7TOTALS:17617617652510,2583,419WATERING SCHEDULEGenerated:2026-05-15 10:28P.O.C. NUMBER: 01Water Source Information:FLOW AVAILABLEWater Meter Size:1-1/2"Flow Available75 GPMPRESSURE AVAILABLEStatic Pressure at POC:138 PSIElevation Change:5.00 ftService Line Size:4"Length of Service Line:20 ftPressure Available:136 PSIDESIGN ANALYSISMaximum Station Flow:34.19 GPMFlow Available at POC:75 GPMResidual Flow Available:40.81 GPMCritical Station:13 Design Pressure:30 PSI Friction Loss:4.92 PSI Fittings Loss:0.49 PSI Elevation Loss:0 PSI Loss through Valve:4.37 PSIPressure Req. at Critical Station:39.8 PSILoss for Fittings:0.13 PSILoss for Main Line:1.26 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:11.3 PSILoss for Master Valve:0.8 PSILoss for Water Meter:1.03 PSICritical Station Pressure at POC:54.3 PSIPressure Available:136 PSIResidual Pressure Available:81.7 PSICRITICAL ANALYSISDATE:NUMBER:PROJECT:DISCOUNT TIRE - BOZEMANMay 14, 2026LLA0644.25TITLE:DESIGN:MJLDRAWN:ZACHECKED:MJLSHEET:SCALE:DISCOUNT TIRE 5889 E VALLEY CENTER ROAD BOZEMAN, MT PROJECT ADDRESS:2111 South C Street, Tacoma, WA 98402 253-209-4053 | Moghan@LyonLA.comREVISIONS:REV 1:REV 2:REV 3:Know what'sbelow.before you dig.CallRDRAWING SET:MOGHAN LYONLICENSED LANDSCAPE A R C HITE C T ST A T E OF MONTANACONCEPTUALREVIEW SET(CONR)L2.01IRRIGATIONSCHEDULE ANDNOTESNTS