HomeMy WebLinkAbout031-L2.2_IRRIGATION SCHEDULESIRRIGATION NOTESESTIMATED WATER CONSUMPTIONWATER CONSUMPTION ESTIMATES ARE BASED ON A SEASONAL24-WEEK WATERING WINDOW, AND ARE LISTED IN ANNUAL TOTALSACRE FEET BASED ON SYSTEM DESIGN3,066 GAL/.WEEK = 0.23 AC.FT.ACRE FEET BASED ON VEGETATION TYPE SQUARE FEETSHRUBS & GROUND COVER: 4,938 S.F. = 0.23 AC.FT.TREES: 336 SF = 0.01 AC.FT.1.CONTRACTOR RESPONSIBLE FOR SCHEDULING PRE-INSTALLATION MEETING WITH CITY OF BOZEMAN WATERCONSERVATION DIVISION PRIOR TO COMMENCING ANY WORK.2.LANDSCAPE & IRRIGATION SELF-CERTIFICATION FORMS REQUIRED TO RECEIVE CITY OF BOZEMAN BUILDINGPERMIT.3.CONTRACTOR RESPONSIBLE TO INFORM LANDSCAPE ARCHITECT OF ANY DISCREPANCIES OR CHANGES NEEDEDTO THE IRRIGATION DESIGN. IF CONTRACTOR MAKES CHANGES TO THE IRRIGATION DESIGN WITHOUT NOTIFYINGTHE LANDSCAPE ARCHITECT, CONTRACTOR ASSUMES FULL RESPONSIBILITY OF THE IRRIGATION SYSTEM DESIGNAND FUNCTIONALITY.4.LANDSCAPE CONTRACTOR RESPONSIBLE FOR SCHEDULING A PUNCH-LIST SUBSTANTIAL COMPLETIONINSPECTION AND FINAL COMPLETION INSPECTION WITH LANDSCAPE ARCHITECT. PRIOR TO INSPECTIONS,IRRIGATION MAINLINE TO BE CHARGED FOR A MINIMUM TWO HOURS AND VALVE BOXES AND EQUIPMENTHOUSINGS SHALL BE OPENED.5.CONTRACTOR RESPONSIBLE FOR PROVIDING IRRIGATION AS-BUILTS TO LANDSCAPE ARCHITECT WITHIN ONEWEEK OF FINAL COMPLETION INSPECTION.6.CONTRACTOR TO VERIFY STATIC PRESSURE IN THE FIELD PRIOR TO BIDDING AND CONSTRUCTION. IN THE EVENTOF A DISCREPANCY, CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IN WRITING OF ANY CHANGESNECESSARY TO PROVIDE THE REQUIRED OPERATIONAL PRESSURE AND FLOW. IF NOTIFICATION IS NOTRECEIVED, CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR SYSTEM OPERABILITY.7.PROVIDE PRESSURE REDUCING VALVE UP STREAM OF BACKFLOW ASSEMBLY IF PRESSURE EXCEEDS 80 PSI.REDUCE TO 60PSI STATIC PRESSURE.8.INSTALLED SYSTEM TO BE FULLY WINTERIZEABLE. CONTRACTOR TO PROVIDE LANDSCAPE ARCHITECT WITHWINTERIZATION PLAN.9.PROVIDE FLUSH VALVES AT END OF EACH DRIP ZONE FOR FLUSHING AND WINTERIZATION. INSTALL AT LEAST ONEFLUSH VALVE AT LOWEST POINT OF SYSTEM FOR DRAINAGE. LOCATE VALVES IN ACCESSIBLE AREAS IN VALVEBOXES. SHOW ALL FLUSH VALVE LOCATIONS ON AS-BUILT IRRIGATION PLAN.10.CONTRACTOR SHALL COORDINATE PLANTING WITH IRRIGATION INSTALLATION.11.THE CONTRACTOR SHALL INSPECT THE SITE AND VERIFY CONDITIONS AND DIMENSIONS PRIOR TOCONSTRUCTION.12.IRRIGATION PLANS ARE DIAGRAMMATIC REPRESENTATIONS ONLY. PLACE LINES IN A COMMON TRENCHWHENEVER POSSIBLE. FIELD ADJUST LINES TO AVOID CONFLICT WITH UTILITIES. PLACE SPRINKLER HEADS AMINIMUM OF 2" FROM HARDSCAPE EDGES.13.IRRIGATION IS COORDINATED WITH THE PLANTING PLAN AND SITE IMPROVEMENTS AND IS DESIGNED WITHRECTANGULAR SPACING GIVING HEAD TO HEAD COVERAGE. COORDINATE IRRIGATION HEAD LAYOUT WITH NEWPLANT MATERIALS, LOCATE SPRAY HEADS 30" FROM BASE OF TREE. DO NOT ALTER HEAD LOCATION, PIPELAYOUT, OR VALVE LOCATION WITHOUT WRITTEN APPROVAL FROM THE LANDSCAPE ARCHITECT. NOTIFYLANDSCAPE ARCHITECT IF DISCREPANCIES OCCUR BETWEEN THE PLANS AND FIELD CONDITIONS.14.ALL COMPONENTS OF IRRIGATION SYSTEM SHALL BE INSTALLED AND PROPERLY ADJUSTED TO PROVIDEADEQUATE HEAD TO HEAD COVERAGE AND ELIMINATE OVER SPRAY ONTO WALKS, BUILDINGS, PARKING AREAS,ETC.15.ALL PIPE SIZES INDICATED ARE MINIMUMS. CONTRACTOR MAY NOT DECREASE PIPE SIZE. LARGER PIPE SIZESMAY BE USED AT NO ADDITIONAL COST TO OWNER. PIPE SIZES INCREASE IN SIZE DOWNSTREAM OF NEXT SPRAYHEAD, AS SHOWN.16.INSTALL ALL IRRIGATION PIPE AND CONTROL WIRES IN MINIMUM 4" PVC SLEEVE BELOW ALL PAVED SURFACESUNLESS OTHERWISE INDICATED ON THE PLANS. INSTALL SLEEVES PRIOR TO PLACEMENT OF PAVEMENTS ANDPAVEMENT SUB-BASE. WHERE PAVEMENT EXISTS BORE AND PLACE SLEEVES.17.COORDINATE IRRIGATION POINTS OF CONNECTION AND LOCATION OF AUTOMATIC CONTROL VALVES WITHLANDSCAPE ARCHITECT. COORDINATE ALL WORK WITH OTHER TRADES, I.E. ELECTRICAL, MASONRY, ETC.18.CONTRACTOR TO PROGRAM AUTOMATIC CONTROLLER TO ALLOW FOR THE EQUIVALENT OF 3/4" OF WATER PERWEEK FOR MANICURED LAWNS AND 1" PER WEEK FOR ALL OTHER PLANTINGS, OR PER SITE AND PLANTINGNEEDS FOR BEST PLANT HEALTH.19.ALL PVC PIPES SHALL BE TRENCHED UNLESS PRE-APPROVED TO BE PULLED IN WRITING BY LANDSCAPEARCHITECT. POLLY PIPE MAY BE PULLED. PROVIDE POSITIVE DRAINAGE OF MAINLINE. PLACE MANUAL DRAIN ATLOW POINTS IN MAINLINE. IDENTIFY LOCATIONS ON AS-BUILTS.20.USE 45° ELBOWS INSTEAD OF 90° ELBOWS ON ALL MAINLINES 2-1/2" AND LARGER. INSTALL CMU THRUST BLOCKSAT ALL MAINLINE CHANGES IN DIRECTION FOR PIPE 2" AND LARGER .21.CONTRACTOR TO INSTALL CONTROLLER AND ACCESSORIES AS REQUIRED. CONTRACTOR TO FURNISH CONTROLWIRES FROM VALVES TO CONTROLLER. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING 110 VOLTSERVICE FROM EXISTING ELECTRICAL SERVICE AND CONNECTION TO CONTROLLER SERVICE.22.INSTALL ONE (1) ADDITIONAL RED CONTROL WIRE AND ONE (1) ADDITIONAL WHITE CONTROL WIRE FROMCONTROLLER TO END OF MAINLINE.23.ALL TREES TO BE ON A DEDICATED DRIP ZONE FOR DROUGHT PREPARATION.24.ALL RAISED PLANTER BEDS TO BE ON A DEDICATED DRIP ZONE AND DAILY WATERING SCHEDULE.IRRIGATION DELIVERABLE CHECKLISTAS SPECIFIED IN NOTES, CONTRACTOR IS RESPONSIBLE FORPROVIDING THE FOLLOWING DELIVERABLES TO THE LANDSCAPEARCHITECT. THIS CHECKLIST IS PROVIDED FOR CONTRACTORCONVENIENCE.·IRRIGATION DESIGN CHANGES, IF APPLICABLE·IRRIGATION AS-BUILT PLANS·IRRIGATION WINTERIZATION PLANSYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER ICZ-101-25 1"DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH 1IN. HY100FILTER SYSTEM. PRESSURE REGULATION: 25PSI. FLOW RANGE: 2 GPMTO 20 GPM. 150 MESH STAINLESS STEEL SCREEN.1HUNTER ICZ-101-25-LF 1"DRIP CONTROL ZONE KIT. 1" ICV GLOBE VALVE WITH 1" HY100 FILTERSYSTEM. PRESSURE REGULATION: 25PSI. FLOW RANGE: .5-15 GPM.150 MESH STAINLESS STEEL SCREEN.1HUNTER ICZ-151-40 1-1/2"DRIP CONTROL ZONE KIT. 1-1/2" ICV GLOBE VALVE WITH 1" HY100FILTER SYSTEM. PRESSURE REGULATION: 40PSI. FLOW RANGE: 20GPM TO 60 GPM. 120 MESH STAINLESS STEEL SCREEN. 1-1/2" INLET XDUAL 1" OUTLETS3HUNTER HDL-06-12-R DRIP RING12AREA TO RECEIVE DRIPLINEHUNTER HDL-06-12-PCHDL-06-12-PC: HUNTER DRIPLINE WITH 0.6 GPH FLOW. LIGHT BROWNTUBING WITH GRAY STRIPING. EMITTERS AT 12" O.C. DRIPLINELATERALS SPACED AT 12" APART, WITH EMITTERS OFFSET FORTRIANGULAR PATTERN. INSTALL WITH HUNTER PLD BARBED ORPLD-LOC FITTINGS.6,666 LFSYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER HQ-33DRC 3/4"QUICK COUPLER VALVE, YELLOW RUBBER COVER, RED BRASS ANDSTAINLESS STEEL, WITH 3/4" NPT INLET, 2-PIECE BODY.1LASCO FITTINGS TUBV-SC1", 1-1/2", 2", AND 3" PLASTIC FULL BLOCK TRUE UNION BALL VALVE.SHUT OFF/ISOLATION VALVE TO ELIMINATE WATER HAMMER. INSTALLSAME SIZE AS MAINLINE.1BUCKNER-SUPERIOR 3000 1"NORMALLY CLOSED BRASS MASTER VALVE THAT PROVIDES DIRTYWATER PROTECTION AND 3-WAY SOLENOID DESIGN. AVAILABLE IN 1",1-1/4", 1-1/2", 2", 2-1/2" AND 3" SIZES.1FEBCO LF825Y 1"REDUCED PRESSURE BACKFLOW PREVENTER, LEAD FREE1HUNTER HCC-800-M8 STATION OUTDOOR WI-FI ENABLED, FULL-FUNCTIONINGCONTROLLER WITH TOUCHSCREEN, COMMERCIAL USE. METALCABINET.1HUNTER WRF-CLIKRAIN/FREEZE SENSOR, INSTALL WITHIN 1000 FT OF CONTROLLER, INLINE OF SIGHT. 22-28 VAC/VDC 100 MA POWER FROM TIMERTRANSFORMER. MOUNT AS NOTED. INCLUDES GUTTER MOUNT.1HUNTER HFS-200FLOW SENSOR FOR USE WITH ACC CONTROLLER, 2IN. SCHEDULE 40SENSOR BODY, 24 VAC, 2 AMP.1POINT OF CONNECTION 1 1/4"DOMESTIC SERVICE LINE BUILDING 11IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1"1,524 LFIRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1 1/2"414.8 LFIRRIGATION MAINLINE: PVC SCHEDULE 40 2"185.6 LFPIPE SLEEVE: PVC SCHEDULE 40155.5 LFMBFCRFFSPOCIRRIGATION SCHEDULECRITICAL ANALYSISGenerated:2026-05-28 14:08P.O.C. NUMBER: 01Water Source Information:DOMESTIC SERVICE LINE BUILDING 1FLOW AVAILABLEPoint of Connection Size:1 1/4"Flow Available28.49 GPMPRESSURE AVAILABLEStatic Pressure at POC:65 PSIPressure Available:65 PSIDESIGN ANALYSISMaximum Station Flow:18.11 GPMFlow Available at POC:28.49 GPMResidual Flow Available:10.38 GPMCritical Station:5 Design Pressure:20 PSI Friction Loss:1.79 PSI Fittings Loss:0.18 PSI Elevation Loss:0 PSI Loss through Valve:11.5 PSIPressure Req. at Critical Station:33.4 PSILoss for Fittings:0.02 PSILoss for Main Line:0.21 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:11.3 PSILoss for Master Valve:2.03 PSICritical Station Pressure at POC:47.0 PSIPressure Available:65 PSIResidual Pressure Available:18.0 PSIFLOW TOTALSArea for Dripline:66.7Drip Ring:1.7Total:68.3 GPMFLOW AVAILABLE28.5 - 273.5 GPMArea for Dripline:1 - 3 ValvesDrip Ring:1 - 1 ValvesTotal:2 - 4 ValvesMMNUMBERMODELTYPEPRECIPSUNMONTUEWEDTHUFRISATIN./WEEKMIN./WEEKGAL./WEEKGAL./DAY1HUNTER ICZ-151-40AREA FOR DRIPLINE1.33 in/h16 min16 min16 min1466522172HUNTER ICZ-151-40AREA FOR DRIPLINE1.32 in/h16 min16 min16 min1467792603HUNTER ICZ-151-40AREA FOR DRIPLINE1.5 in/h14 min14 min14 min1417432484HUNTER ICZ-101-25-LFDRIP RING0.57 in/h36 min36 min36 min110617859.45HUNTER ICZ-101-25AREA FOR DRIPLINE1.48 in/h14 min14 min14 min141714238TOTALS:9696962803,0661,022WATERING SCHEDULEPERFORMANCE PATHWAYSHEET No:JOB No:DATE:PREPARED FOR:REV:DATE:DESCRIPTION:LANDSCAPEARCHITECTURE614 S Ferguson Ave., Ste 3Bozeman, MT 59718(406) 624-9111hello@inContour.comwww.inContour.com01 05/28/2026 UPDATED HVAC, BIKE RACK, WATERLINE & TREE LOCATIONS
Bozeman Classic Pickleball Club
350 Gallatin Park Dr. Bozeman, MT(406) 931-0564Bozeman, MT 597152414 Arabian Ave.Bozeman Classic Pickleball Club2551005/28/2026L2.2IRRIGATION SCHEDULE & NOTESSTAT
E
OFMONTANALANDSCAPEARCH
ITECTLICENSE
D LESSA R.MILLARD27411