Loading...
HomeMy WebLinkAbout019 - Appendix K -Water Design Report WATER DESIGN REPORT FOR LAUREL MEADOWS SUBDIVISION BOZEMAN �-AANA GALLATIN COUNTY MONTANA E • Nfl'Vgl-'A'�,'J,' Prepared By: Morrison-Maierle, Inc. Morrison 2880 Technology Blvd. West Maierle P.O. Box 1113 engineers-surveyors planners scientists Bozeman, Montana 59771-1113 Engineer: Cooper Krause, PE Date: November 26, 2025 File: 10130.004 Table of Contents 1 Executive Summary ........................................................................ 1 2 General Information (DEQ 1.1.1) ....................................................... 1 3 Extend of Water Works System, Including (DEQ 1.1.2) ........................... 1 4 Alternate Plans (1.1.3) ..................................................................... 2 5 Site Conditions (1.1.4) ..................................................................... 2 6 Water Use Date, Including (1.1.5): ....................................................2 7 Flow Requirements (1.1.6) .............................................................. 3 8 Sources of Water Supply (1.1.7) ....................................................... 4 9 Proposed Treatment Processes (1.1.8) ................................................ 4 10 Sewage System Available (1.1.9) ..................................................... 4 11 Waste Disposal (1.1.10) ................................................................ 4 12 Automation (1.1.11) .....................................................................4 13 Project Sites (1.1.12) .................................................................... 5 14 Financing (1.1.13) ......................................................................... 5 15 Future Extensions (1.1.14)................................................................. 5 EXHIBITS Exhibit A Vicinity Map Exhibit B Utility Layout APPENDICES Appendix A WaterCAD Results N:\10130\001.04-PDZANDPPLAT\04 DESIGN\REPORTS\WATER\WATER DESIGN REPORT.DOCX West Park Subdivision Water Distribution Design Report 1 Executive Summary This report provides a basis for design of the Laurel Meadows Subdivision Phase 1 and 2 water distribution system. The water distribution system serving this project is in accordance with the MDEQ Circular No. 1; Montana Public Works Standard Specifications (MPWSS); The City of Bozeman Modifications to MPWSS; City of Bozeman Design Standards; and the City of Bozeman Fire Service Line Standard. 2 General Information (DEQ 1.1.1) a. Water will be provided through the extension of 8" water mains located within the streets in the subdivision. These water mains will be connected to an existing 12" main in Babcock (south), and an existing 12" main in Laurel Parkway (west). Additional water main extensions will be required with each phase as it develops. b. The proposed water main infrastructure will be served by the City of Bozeman. c. Project Developer 8FC, LLC PO Box 11388 Bozeman, MT 59719 d. System Owner City of Bozeman PO Box 1230 Bozeman, MT 59715 3 Extent of Water Works System, Including (DEQ 1.1.2) a. The proposed water main is an extension of the City of Bozeman water infrastructure. The 8" water main will tie into an existing 8" water which is connected to an existing 12" main in Laurel Parkway. All dead ends due to phasing will be less than 500 feet. Fire hydrants for the project are located at approximate intervals of 500 feet. Also, as part of the water main design all thrust restraints will be designed to withstand the test pressure 200 psi. b. Future main extensions will be required to service the future phases including a looped connection to the existing 8" water main located in Vaughn Drive north of the subdivision. c. Laurel Meadows Subdivision will be compromised of four phases zoned R-4, open space and a park. As the lots are planned for both single family and multifamily use, additional main extensions will be required to serve the multifamily buildings on the site. 4 Alternate Plans (1.1.3) There were no other alternate plans considered. 5 Site Conditions (1.1.4) a. Laurel Meadows Subdivision is currently undeveloped agricultural land which slopes gently to the north and east with existing grades of less than 4% and mostly Blackdog silt loam soil deposits (USDA, Natural Resources Conservation Service, Web Soil Survey) b. A site specific geotechnical report has been completed for the The Lakes at Valley West (south) by Castle Rock Civil and Geotechnical Engineering, April 10, 2020. The site is favorable for the building foundation construction. The buildings are to be constructed using conventional stem wall foundations with a concrete slab on grade. The continuous foundations and interior column footings are to be constructed on structural fill placed on top of the native gravels. c. The high groundwater levels are currently 1-4 feet below the existing grade. The groundwater flows generally from the south to the north based on groundwater flow in the valley. The groundwater at this site is variable based on seasonal precipitation and irrigation practices. 6 Water Use Data, Including (1.1.5): Predicted Average Daily Water Demand Water demand predicted in this report is based on the latest detailed information on per capita water use published by in the City of Bozeman Design and Construction Standards, dated October 2024. The average per capita per day use for residential units is 135 gallons per capita per day at 2.17 people per dwelling unit. This results in an average day demand of 293 gallons per day per unit (0.20 gpm). The first two phases of the project will have 96 single-family lots and 2 multifamily lots with an assumed 8 and 4 dwelling units, respectively. The following table indicates the service area utilized and the Average Daily Water Demand for this hydraulic analysis. Lot Dwelling Units Avg Flow (gpd) Avg Flow (gpm) At 0.2gpm/unit Phase 1 41 12,011 8.3 Phase 2 67 19,628 13.6 Total 108 31,639 21.9 Peak Demand Factors For planning purposes the Maximum Daily Demand Factor used will be 2.3 and the Peak Hourly Demand Factor used will be 3.0. This yields to a maximum daily demand of 50.3 gpm, and a peak hour demand of 65.7 gpm. These peaking factors were taken from City of Bozeman, Design and Construction Standards. Pressure Zones The project is in one pressure zone. 7 Flow Requirements (1.1.6) Modeling Procedure The proposed water distribution system for the project and the associated areas located on the existing system were modeled using WaterCAD including the information detailed in this report. The total water demand for the system includes the Maximum Daily Demand and the required fire flow of 1500 gpm as determined by the Insurance Services Office (ISO) criteria. The Maximum Daily Demand is calculated by multiplying the Average Daily Demand by a peaking factor of 2.3 as described above. Flow from City of Bozeman existing fire hydrant #2410 and #2412 were used to determine the existing water distribution flow capabilities. The static, residual and pitot pressures for the fire hydrant were obtained from the City of Bozeman Water Facility Plan from a tested completed on 9/28/2015. This information was used to develop a relationship between residual pressure and flow as simulated in the model by a pump and a reservoir. The minimum pressure used for pipe main sizing was 35-psi during normal uses and no less than 20-psi residual pressure during fire hydrant full flow condition at any supply node. A "C" of 130 is used for the Hazen-Williams pipe roughness factor. Model Results The model's results indicate that 8-inch distribution mains for the project will supply the needed maximum daily flow with fire flow while maintaining the required 20-psi residual pressure at all points within the modeled area. (See the WaterCAD model flow results located in the appendix at the end of this report). Note that the fire flow report results are ran with maximum day demand running. Model Conclusion Utilizing the existing 12-inch water mains located in Laurel Parkway and Babcock Street and then infilling the proposed project with 8-inch mains the area water distribution system meets the required design criteria and will be able to serve the interior needs of the lots which will result in additional looping and redundancy for the area. Water service and fire service lines will be sized as part of the site plan applications for each multifamily lot. 8 Sources of Water Supply (1.1.7) Water is supplied from City of Bozeman 9 Proposed Treatment Processes (1.1.8) Non-applicable 10 Sewage System Available (1.1.9) The area is served by the City of Bozeman wastewater treatment facility 11 Waste Disposal (1.1.10) Non-applicable 12 Automation (1.1.11) Non-applicable 13 Project Sites (1.1.12) The development is bounded by Vaughn Drive to the north, existing park space to the to the east, West Babcock Street to the south, and Laurel Parkway to the west. This property was evaluated during the Norton East Ranch Subdivision as Phase 6, now known as Laurel Meadows. The adjacent properties to the north and south of the site are Existing single family residential subdivisions with a future subdivision to the west. There is an existing church to the east of the project location. There are no existing sources of potential pollution or interference of the proposed water distribution system. 14 Financing (1.1.13) Non-applicable 15 Future Extensions (1.1.14) Due to phasing of the project, future extensions will be needed. EXHIBIT A VICINITY MAP EXHIBIT B UTILITY PLAN APPENDIX A WATERCAD RESULTS EXHIBIT A VICINITY MAP s. . S �v 6V011"CAnlir Rd `' _ Ul I j r DurstonR 1 { z ,, - r - �`, � T -- •W Babcock St - jj -• -1 1 aYi' d ey Mall Weft Cu#'a 0 Huffine Ln Huffine Ln ' ! Huffine Ln • .W li • LI r l f iM. 11 Swl� _I _ m ::0 Technology Blvd West DRAWN BY: CGM PROJECT NO. LAURELMorrison Boz man,MT 59718 •D• :D • 30004 .0.587.0721 BOZEMAN MONTANA In EXHIBIT B UTILITY PLAN U =_ —w--- —w— —w-----w-----w-- ---S-----5 - 5-----=MHN DRIVI§--� �� \ .r PARK 2.74 acs. PHASE 1 II `— — — ` - - - - - —F. LEGEND - ` PHASE 1 BOUNDARY �` / / I FUTURE \ �� PHASE 3 \ \ \ \ \ PHASE 2 BOUNDARY —aw— PROPOSED WATER MAIN �s PROPOSED SEWER MAIN — � l PROPOSED STORM MAIN � - - - - - - - � , // � � � --------------- t It PARK ---w-----w— 8.05 ace. \ .i T� I > I .t �i PARK \ I FUTURE I PHASE 2 N� I PHASE 4 I l A I I II II II \ � I I I — ' I m T •:v-----w-----w-----w-----w-----w-- ----- � w--- w----� \ WBABCOCK ST o , o � r -N- W 'o qU 100 50 0 100 200 F Q SCALE IN FEET a a aDRAWN BY: CGM PROJECT NO. a ■ Morrison 2880 Technology Blvd West LAUREL MEADOWS o Bozeman,MT 59718 10130.004 DSGN.BY: CGM 21 BOZEMAN MT Y CPK M a i e r l e • 4www.m�m?et APPDAR.BE 11I2025 FIGURE NUMBER engineers.surveyors•planners.scientists PHASE 1 AND 2 UTILITY PLAN r�j_D coPYRIGHT®MORRISON-MHIERLE,2025 H Jl D Z lLLJL 1 1J APPENDIX A WATERCAD RESULTS Laurel Meadows Water Model Report Network Schematic Named View - 1 Color Coding Legend Pipe:Diameter(in) - 6.0 _ 8.0 54 = 12.0 Other 14 WaterCAD laurel meadows.wtg Bentley Systems,Inc. Haestad Methods Solution Center [24.00.02.201 11/26/2025 76 Watertown Road,Suite 2D Thomaston,CT 06787 USA +1-203- Page 1 of 20 755-1666 Laurel Meadows Water Model Report Average Daily Demand Scenario Reservoir Table -Time: 0.00 hours ID Label Elevation Zone Flow(Out net) Hydraulic (ft) (gpm) Grade (ft) 77 R-1 4,800.00 <None> 22 4,800.00 Pump Table -Time: 0.00 hours ID Label Elevation Pump Status(Initial) Hydraulic Hydraulic (ft) Definition Grade Grade (Suction) (Discharge) (ft) (ft) 76 PMP-1 4,793.00 StoneFly- On 4,800.00 5,003.59 DragonFly Flow(Total) Pump Head (gpm) (ft) 22 203.59 Flow Head (Wn) Qt) Shutoff: 0 203.59 Design: 4,822 152.69 Max.Operating: 9,644 0.00 StoneFly-DragonFly 225.00 120.0 200.00 v 175.00 100.0 3 150.00 80.0 M 125.00 100.00 60.0 j = 75.00 40.0 _Q 50.00 20.0 25.00 0.00 0.0 0 1,250 2,500 3,750 5,000 6,250 7,500 8,750 10,000 Flow(gpm) Coefficients: a = 203.59 ft; b =2.189e-006 ft/(gpm)-c; c= 2.000 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 2 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Average Daily Demand Scenario Junction Table -Time: 0.00 hours Label Elevation Demand Hydraulic Pressure (ft) (gpm) Grade (psi) (ft) 3-1 4,789.48 0 5,003.58 93 3-2 4,789.60 0 5,003.58 93 3-3 4,791.66 0 5,003.58 92 3-4 4,790.70 0 5,003.58 92 3-5 4,790.89 0 5,003.58 92 3-6 4,793.19 0 5,003.58 91 3-7 4,793.38 0 5,003.58 91 3-8 4,794.50 0 5,003.58 90 3-9 4,788.83 0 5,003.58 93 3-10 4,782.95 0 5,003.58 95 3-11 4,779.43 0 5,003.58 97 3-12 4,778.79 0 5,003.58 97 3-13 4,775.00 0 5,003.58 99 3-14 4,791.50 0 5,003.58 92 3-15 4,792.00 0 5,003.58 92 3-16 4,794.00 0 5,003.58 91 3-17 4,794.80 0 5,003.58 90 3-18 4,794.20 0 5,003.58 91 3-19 4,794.00 0 5,003.58 91 3-22 4,787.79 0 5,003.58 93 3-25 4,781.58 0 5,003.58 96 3-26 4,785.35 0 5,003.58 94 3-27 4,784.36 0 5,003.58 95 3-28 4,782.63 0 5,003.58 96 3-29 4,782.73 0 5,003.58 96 3-30 4,782.97 0 5,003.58 95 3-31 4,783.84 0 5,003.58 95 3-32 4,782.85 0 5,003.58 95 3-44 4,775.50 0 5,003.58 99 3-45 4,775.00 0 5,003.58 99 3-46 4,775.00 0 5,003.58 99 3-47 4,775.25 0 5,003.58 99 3-48 4,781.78 0 5,003.58 96 3-1 4,781.40 0 5,003.58 96 3-2 4,780.68 0 5,003.58 96 3-4 4,781.20 0 5,003.58 96 3-6 4,784.54 0 5,003.58 95 3-7 4,787.96 0 5,003.58 93 3-8 4,788.83 0 5,003.58 93 3-9 4,789.88 0 5,003.58 92 3-10 4,784.18 0 5,003.58 95 3-11 4,788.60 0 5,003.58 93 3-12 4,782.00 0 5,003.58 96 3-13 4,784.89 0 5,003.58 95 3-15 4,780.95 0 5,003.58 96 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 3 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Average Daily Demand Scenario Junction Table -Time: 0.00 hours Label Elevation Demand Hydraulic Pressure (ft) (gpm) Grade (psi) (ft) 3-17 4,784.22 0 5,003.58 95 3-18 4,796.00 2 5,003.58 90 3-19 4,796.00 2 5,003.58 90 3-20 4,787.45 0 5,003.58 94 3-21 4,796.00 3 5,003.58 90 3-22 4,796.00 2 5,003.58 90 3-23 4,787.81 0 5,003.58 93 3-24 4,796.00 1 5,003.58 90 3-25 4,785.00 0 5,003.58 95 3-26 4,796.00 1 5,003.58 90 3-27 4,784.50 0 5,003.58 95 3-28 4,820.00 2 5,003.58 79 3-29 4,780.22 0 5,003.58 97 3-30 4,820.00 1 5,003.58 79 3-31 4,781.03 0 5,003.58 96 3-32 4,792.00 3 5,003.58 92 3-33 4,792.00 2 5,003.58 92 3-34 4,782.31 0 5,003.58 96 3-35 4,792.00 2 5,003.58 92 3-36 4,779.25 0 5,003.58 97 J-37 4,792.00 2 5,003.58 92 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 4 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Average Daily Demand Scenario Pipe Table -Time: 0.00 hours Label Length Diameter Material Hazen-Williams Flow Velocity (Scaled) (in) C (gpm) (ft/s) (ft) P-1 52 12.0 Ductile Iron 130.0 0 0.00 P-2 571 12.0 Ductile Iron 130.0 -10 0.03 P-3 218 12.0 Ductile Iron 130.0 -10 0.03 P-4 131 12.0 Ductile Iron 130.0 -10 0.03 P-5 391 12.0 Ductile Iron 130.0 -10 0.03 P-6 41 12.0 Ductile Iron 130.0 -10 0.03 P-7 175 12.0 Ductile Iron 130.0 0 0.00 P-8 41 12.0 Ductile Iron 130.0 10 0.03 P-9 490 12.0 Ductile Iron 130.0 10 0.03 P-10 326 12.0 Ductile Iron 130.0 10 0.03 P-11 65 12.0 Ductile Iron 130.0 10 0.03 P-13 196 8.0 Ductile Iron 130.0 -12 0.07 P-14 15 8.0 Ductile Iron 130.0 -12 0.07 P-15 262 8.0 Ductile Iron 130.0 -12 0.07 P-16 293 8.0 Ductile Iron 130.0 10 0.07 P-17 15 8.0 Ductile Iron 130.0 10 0.07 P-18 197 8.0 Ductile Iron 130.0 10 0.07 P-19 42 8.0 Ductile Iron 130.0 -22 0.14 P-20 21 8.0 Ductile Iron 130.0 22 0.14 P-21 15 8.0 Ductile Iron 130.0 22 0.14 P-31 108 8.0 Ductile Iron 130.0 1 0.01 P-32 169 8.0 Ductile Iron 130.0 1 0.01 P-33 98 8.0 Ductile Iron 130.0 3 0.02 P-34 61 8.0 Ductile Iron 130.0 -4 0.03 P-36 199 8.0 Ductile Iron 130.0 1 0.01 P-49 308 8.0 Ductile Iron 130.0 0 0.00 P-50 69 8.0 Ductile Iron 130.0 0 0.00 P-51 56 8.0 Ductile Iron 130.0 0 0.00 P-52 30 6.0 Ductile Iron 130.0 0 0.00 P-53 29 6.0 Ductile Iron 130.0 0 0.00 P-54 39 6.0 Ductile Iron 130.0 0 0.00 P-55 35 6.0 Ductile Iron 130.0 0 0.00 P-56 34 6.0 Ductile Iron 130.0 0 0.00 P-57 49 6.0 Ductile Iron 130.0 0 0.00 P-58 23 6.0 Ductile Iron 130.0 0 0.00 P-59 12 6.0 Ductile Iron 130.0 0 0.00 P-60 13 6.0 Ductile Iron 130.0 0 0.00 P-63 7 6.0 Ductile Iron 130.0 0 0.00 P-64 11 6.0 Ductile Iron 130.0 0 0.00 P-65 10 6.0 Ductile Iron 130.0 0 0.00 P-12(1) 276 12.0 Ductile Iron 130.0 5 0.01 P-12(2) 227 12.0 Ductile Iron 130.0 0 0.00 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 5 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Maximum Daily Demand Scenario Reservoir Table -Time: 0.00 hours ID Label Elevation Zone Flow(Out net) Hydraulic (ft) (gpm) Grade (ft) 77 R-1 4,800.00 <None> 50 4,800.00 Pump Table -Time: 0.00 hours ID Label Elevation Pump Status(Initial) Hydraulic Hydraulic (ft) Definition Grade Grade (Suction) (Discharge) (ft) (ft) 76 PMP-1 4,793.00 StoneFly- On 4,800.00 5,003.58 DragonFly Flow(Total) Pump Head (gpm) (ft) 50 203.58 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 6 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Maximum Daily Demand Scenario Junction Table -Time: 0.00 hours Label Elevation Demand Hydraulic Pressure (ft) (gpm) Grade (psi) (ft) 3-1 4,789.48 0 5,003.56 93 3-2 4,789.60 0 5,003.56 93 3-3 4,791.66 0 5,003.56 92 3-4 4,790.70 0 5,003.56 92 3-5 4,790.89 0 5,003.57 92 3-6 4,793.19 0 5,003.57 91 3-7 4,793.38 0 5,003.57 91 3-8 4,794.50 0 5,003.57 90 3-9 4,788.83 0 5,003.56 93 3-10 4,782.95 0 5,003.56 95 3-11 4,779.43 0 5,003.56 97 3-12 4,778.79 0 5,003.56 97 3-13 4,775.00 0 5,003.56 99 3-14 4,791.50 0 5,003.57 92 3-15 4,792.00 0 5,003.57 92 3-16 4,794.00 0 5,003.58 91 3-17 4,794.80 0 5,003.57 90 3-18 4,794.20 0 5,003.57 91 3-19 4,794.00 0 5,003.58 91 3-22 4,787.79 0 5,003.56 93 3-25 4,781.58 0 5,003.56 96 3-26 4,785.35 0 5,003.56 94 3-27 4,784.36 0 5,003.56 95 3-28 4,782.63 0 5,003.56 96 3-29 4,782.73 0 5,003.56 96 3-30 4,782.97 0 5,003.56 95 3-31 4,783.84 0 5,003.56 95 3-32 4,782.85 0 5,003.56 95 3-44 4,775.50 0 5,003.56 99 3-45 4,775.00 0 5,003.56 99 3-46 4,775.00 0 5,003.56 99 3-47 4,775.25 0 5,003.56 99 3-48 1 4,781.78 1 0 1 5,003.56 1 96 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 7 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Maximum Daily Demand Scenario Hydrant Table -Time: 0.00 hours ID Label Hydrant Status Include Emitter Length Elevation Hydrant Coefficient (Hydrant (ft) Lateral Loss? (gpm/psi^n) Lateral) (ft) 137 H-1 Closed False 0.000 20 4,781.20 138 H-2 Closed False 0.000 20 4,798.50 139 H-3 Closed False 0.000 20 4,800.37 140 H-4 Closed False 0.000 20 4,798.10 141 H-5 Closed False 0.000 20 4,798.71 142 H-6 Closed False 0.000 20 4,796.12 143 H-7 Closed False 0.000 20 4,786.28 144 H-8 Closed False 0.000 20 4,782.00 145 H-9 Closed False 0.000 20 4,782.50 148 H-10 Closed False 0.000 20 4,786.33 149 H-11 Closed False 0.000 20 4,788.52 150 H-12 Closed False 0.000 1 20 4,794.76 Zone Demand Demand Hydraulic Pressure Collection (gpm) Grade (psi) (ft) <None> <Collection: 0 0 5,003.57 96 items> <None> <Collection: 0 0 5,003.57 89 items> <None> <Collection: 0 0 5,003.57 88 items> <None> <Collection: 0 0 5,003.57 89 items> <None> <Collection: 0 0 5,003.56 89 items> <None> <Collection: 0 0 5,003.56 90 items> <None> <Collection: 0 0 5,003.56 94 items> <None> <Collection: 0 0 5,003.56 96 items> <None> <Collection: 0 0 5,003.56 96 items> <None> <Collection: 0 0 5,003.56 94 items> <None> <Collection: 0 0 5,003.56 93 items> <None> <Collection: 0 0 5,003.56 90 items> Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 8 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Maximum Daily Demand Scenario Pipe Table -Time: 0.00 hours Label Length Diameter Material Hazen-Williams Flow Velocity (Scaled) (in) C (gpm) (ft/s) (ft) P-1 52 12.0 Ductile Iron 130.0 0 0.00 P-2 571 12.0 Ductile Iron 130.0 -23 0.07 P-3 218 12.0 Ductile Iron 130.0 -23 0.07 P-4 131 12.0 Ductile Iron 130.0 -24 0.07 P-5 391 12.0 Ductile Iron 130.0 -24 0.07 P-6 41 12.0 Ductile Iron 130.0 -24 0.07 P-7 175 12.0 Ductile Iron 130.0 0 0.00 P-8 41 12.0 Ductile Iron 130.0 23 0.07 P-9 490 12.0 Ductile Iron 130.0 23 0.07 P-10 326 12.0 Ductile Iron 130.0 23 0.07 P-11 65 12.0 Ductile Iron 130.0 23 0.07 P-13 196 8.0 Ductile Iron 130.0 -27 0.17 P-14 15 8.0 Ductile Iron 130.0 -27 0.17 P-15 262 8.0 Ductile Iron 130.0 -27 0.17 P-16 293 8.0 Ductile Iron 130.0 24 0.15 P-17 15 8.0 Ductile Iron 130.0 24 0.15 P-18 197 8.0 Ductile Iron 130.0 24 0.15 P-19 42 8.0 Ductile Iron 130.0 -50 0.32 P-20 21 8.0 Ductile Iron 130.0 50 0.32 P-21 15 8.0 Ductile Iron 130.0 50 0.32 P-31 108 8.0 Ductile Iron 130.0 2 0.01 P-32 169 8.0 Ductile Iron 130.0 3 0.02 P-33 98 8.0 Ductile Iron 130.0 8 0.05 P-34 61 8.0 Ductile Iron 130.0 -10 0.07 P-36 199 8.0 Ductile Iron 130.0 3 0.02 P-49 308 8.0 Ductile Iron 130.0 0 0.00 P-50 69 8.0 Ductile Iron 130.0 0 0.00 P-51 56 8.0 Ductile Iron 130.0 0 0.00 P-52 30 6.0 Ductile Iron 130.0 0 0.00 P-53 29 6.0 Ductile Iron 130.0 0 0.00 P-54 39 6.0 Ductile Iron 130.0 0 0.00 P-55 35 6.0 Ductile Iron 130.0 0 0.00 P-56 34 6.0 Ductile Iron 130.0 0 0.00 P-57 49 6.0 Ductile Iron 130.0 0 0.00 P-58 23 6.0 Ductile Iron 130.0 0 0.00 P-59 12 6.0 Ductile Iron 130.0 0 0.00 P-60 13 6.0 Ductile Iron 130.0 0 0.00 P-63 7 6.0 Ductile Iron 130.0 0 0.00 P-64 11 6.0 Ductile Iron 130.0 0 0.00 P-65 10 6.0 Ductile Iron 130.0 0 0.00 P-12(1) 276 12.0 Ductile Iron 130.0 11 0.03 P-12(2) 227 12.0 Ductile Iron 130.0 0 0.00 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 9 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Fire Flow Fire Flow Results Table - Time: 0.00 hours Label Fire Flow Fire Flow Flow(Total Flow(Total Pressure Pressure (Needed) (Available) Needed) Available) (Calculated (Calculated (gpm) (gpm) (gpm) (gpm) Residual) System Lower (psi) Limit) (psi) H-1 1,500 3,500 1,500 3,500 58 54 H-2 1,500 3,500 1,500 3,500 51 54 H-3 1,500 3,500 1,500 3,500 45 51 H-4 1,500 3,500 1,500 3,500 47 49 H-5 1,500 3,500 1,500 3,500 45 48 H-6 1,500 3,500 1,500 3,500 39 46 H-7 1,500 3,500 1,500 3,500 49 43 H-8 1,500 3,500 1,500 3,500 45 43 H-9 1,500 3,500 1,500 3,500 20 27 H-10 1,500 3,500 1,500 3,500 52 42 H-11 1,500 3,500 1,500 3,500 49 40 H-12 1,500 3,500 1,500 3,500 52 46 H-13 1,500 3,500 1,500 3,500 44 36 H-14 1 1,500 1 31500 1 1,500 1 3,500 1 46 1 43 Junction w/ Is Fire Flow Minimum Run Balanced? Pressure (System) J-28 True J-28 True J-28 True J-28 True J-30 True J-30 True J-30 True J-30 True J-44 True J-30 True J-28 True J-28 True J-28 True J-30 True Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 10 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Peak Hour Demand Scenario Reservoir Table -Time: 0.00 hours ID Label Elevation Zone Flow(Out net) Hydraulic (ft) (gpm) Grade (ft) 77 R-1 4,800.00 <None> 66 4,800.00 Pump Table -Time: 0.00 hours ID Label Elevation Pump Status(Initial) Hydraulic Hydraulic (ft) Definition Grade Grade (Suction) (Discharge) (ft) (ft) 76 PMP-1 4,793.00 StoneFly- On 4,800.00 5,003.57 DragonFly Flow(Total) Pump Head (gpm) (ft) 66 203.58 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 11 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Peak Hour Demand Scenario Junction Table -Time: 0.00 hours Label Elevation Demand Hydraulic Pressure (ft) (gpm) Grade (psi) (ft) 3-1 4,789.48 0 5,003.55 93 3-2 4,789.60 0 5,003.55 93 3-3 4,791.66 0 5,003.55 92 3-4 4,790.70 0 5,003.55 92 3-5 4,790.89 0 5,003.55 92 3-6 4,793.19 0 5,003.55 91 3-7 4,793.38 0 5,003.55 91 3-8 4,794.50 0 5,003.55 90 3-9 4,788.83 0 5,003.55 93 3-10 4,782.95 0 5,003.55 95 3-11 4,779.43 0 5,003.54 97 3-12 4,778.79 0 5,003.54 97 3-13 4,775.00 0 5,003.54 99 3-14 4,791.50 0 5,003.56 92 3-15 4,792.00 0 5,003.56 92 3-16 4,794.00 0 5,003.57 91 3-17 4,794.80 0 5,003.56 90 3-18 4,794.20 0 5,003.56 91 3-19 4,794.00 0 5,003.57 91 3-22 4,787.79 0 5,003.55 93 3-25 4,781.58 0 5,003.54 96 3-26 4,785.35 0 5,003.54 94 3-27 4,784.36 0 5,003.54 95 3-28 4,782.63 0 5,003.54 96 3-29 4,782.73 0 5,003.54 96 3-30 4,782.97 0 5,003.54 95 3-31 4,783.84 0 5,003.54 95 3-32 4,782.85 0 5,003.54 95 3-44 4,775.50 0 5,003.54 99 3-45 4,775.00 0 5,003.54 99 3-46 4,775.00 0 5,003.54 99 3-47 4,775.25 0 5,003.54 99 3-48 1 4,781.781 0 1 5,003.54 1 96 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 12 of 13 06787 USA +1-203-755-1666 Laurel Meadows Water Model Report Peak Hour Demand Scenario Pipe Table -Time: 0.00 hours Label Length Diameter Material Hazen-Williams Flow Velocity (Scaled) (in) C (gpm) (ft/s) (ft) P-1 52 12.0 Ductile Iron 130.0 0 0.00 P-2 571 12.0 Ductile Iron 130.0 -30 0.09 P-3 218 12.0 Ductile Iron 130.0 -30 0.09 P-4 131 12.0 Ductile Iron 130.0 -31 0.09 P-5 391 12.0 Ductile Iron 130.0 -31 0.09 P-6 41 12.0 Ductile Iron 130.0 -31 0.09 P-7 175 12.0 Ductile Iron 130.0 0 0.00 P-8 41 12.0 Ductile Iron 130.0 30 0.09 P-9 490 12.0 Ductile Iron 130.0 30 0.09 P-10 326 12.0 Ductile Iron 130.0 30 0.09 P-11 65 12.0 Ductile Iron 130.0 30 0.09 P-13 196 8.0 Ductile Iron 130.0 -35 0.22 P-14 15 8.0 Ductile Iron 130.0 -35 0.22 P-15 262 8.0 Ductile Iron 130.0 -35 0.22 P-16 293 8.0 Ductile Iron 130.0 31 0.20 P-17 15 8.0 Ductile Iron 130.0 31 0.20 P-18 197 8.0 Ductile Iron 130.0 31 0.20 P-19 42 8.0 Ductile Iron 130.0 -66 0.42 P-20 21 8.0 Ductile Iron 130.0 66 0.42 P-21 15 8.0 Ductile Iron 130.0 66 0.42 P-31 108 8.0 Ductile Iron 130.0 3 0.02 P-32 169 8.0 Ductile Iron 130.0 4 0.03 P-33 98 8.0 Ductile Iron 130.0 10 0.06 P-34 61 8.0 Ductile Iron 130.0 -13 0.09 P-36 199 8.0 Ductile Iron 130.0 4 0.03 P-49 308 8.0 Ductile Iron 130.0 0 0.00 P-50 69 8.0 Ductile Iron 130.0 0 0.00 P-51 56 8.0 Ductile Iron 130.0 0 0.00 P-52 30 6.0 Ductile Iron 130.0 0 0.00 P-53 29 6.0 Ductile Iron 130.0 0 0.00 P-54 39 6.0 Ductile Iron 130.0 0 0.00 P-55 35 6.0 Ductile Iron 130.0 0 0.00 P-56 34 6.0 Ductile Iron 130.0 0 0.00 P-57 49 6.0 Ductile Iron 130.0 0 0.00 P-58 23 6.0 Ductile Iron 130.0 0 0.00 P-59 12 6.0 Ductile Iron 130.0 0 0.00 P-60 13 6.0 Ductile Iron 130.0 0 0.00 P-63 7 6.0 Ductile Iron 130.0 0 0.00 P-64 11 6.0 Ductile Iron 130.0 0 0.00 P-65 10 6.0 Ductile Iron 130.0 0 0.00 P-12(1) 276 12.0 Ductile Iron 130.0 15 0.04 P-12(2) 227 12.0 Ductile Iron 130.0 0 0.00 Bentley Systems,Inc. Haestad Methods Solution WaterCAD laurel meadows.wtg Center [24.00.02.201 11/7/2025 76 Watertown Road,Suite 2D Thomaston,CT Page 13 of 13 06787 USA +1-203-755-1666