HomeMy WebLinkAbout036 - E001 - ELECTRICAL LEGENDS AND GENERAL NOTESABOVE COUNTER, 4" BACK SPLASHAC AUTOMATIC TRANSFER SWITCHATS ABOVE FINISHED GRADEAFG ABOVE FINISHED FLOORAFF BELOW GRADEBLG BOTTOM OF DEVICEBOD CONDUITC SYMBOL DESCRIPTION LAY-IN OR RECESSED FIXTURE, SIZE ON PLANS WALL MOUNTED FIXTURE, SIZE ON PLANS SURFACE MOUNTED FIXTURE, SIZE ON PLANS PENDANT OR SURFACE MOUNTED FIXTURE, SIZE ON PLANS RECESSED DOWNLIGHT FIXTURE SURFACE MOUNTED FIXTURE WALL MOUNTED FIXTURE CEILING MOUNTED, WALL MOUNTED EXIT LIGHT (W/ DIRECTIONAL ARROWS) PENDANT MOUNTED FIXTURE, SIZE ON PLANS SHADED FIXTURE INDICATES EMERGENCY POWER FIXTURE. WALL WASH OR DIRECTIONAL FIXTURE WALL SCONCE FIXTURE TRACK FIXTURE, SEE PLAN FOR SIZE AND HEADS SQUARE POLE MOUNTED FIXTURE, EXTERIOR BOLLARD FIXTURE, EXTERIOR CEILINGCLG CENTER OF DEVICECOD COPPERCU DEMO(D) EXISTING(E) ELECTRICAL CONTRACTOREC GENERAL CONTRACTORGC GROUNDGND FIELD ADJUSTABLE LONG TIME, SHORT TIME AND INSTANTANEOUS LSI FIELD ADJUSTABLE LONG TIME, SHORT TIME, INSTANTANEOUS AND GROUND FAULT LSIG MECHANICAL CONTRACTORMC NEW(N) NIGHT LIGHTNL QUANTITYQTY RELOCATED(R) SURFACESF TEMPERATURE CONTROL CONTRACTORTC TELEPHONE TERMINAL BOARDTTB TYPICALTYP UNDERGROUNDUG WITHW/ WIRE MOLDWM WEATHER PROOF (WHILE IN USE)WP TRANSFORMERXFMR SWITCH DESIGNATIONa,b,c etc CIRCUIT DESIGNATION, PANEL BN1L, CIRCUITS 2,4,6BN1L-2,4,6 INDICATES DETAIL 1 ON SHEET E5011/E501 SHEET WORK NOTE HOME RUN TO PANEL CONDUIT CONCEALED IN CEILING OR WALL CONDUIT CONCEALED UNDER FLOOR OR GRADE LOW VOLTAGE CIRCUIT FIBER OPTIC CABLE CABLE TRAY CIRCUIT, MINIMUM OF 2#12 & 1#12 GND, OR AS NOTED. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR NUMBER OF CIRCUITS SHOWN. CONTRACTOR MAY ELECT TO COMBINE CIRCUITS WHERE APPROPRIATE. DERATE CONDUCTORS PER NEC TABLE 310.15(C)(1) AS REQUIRED. LV SHEET DEMO WORK NOTE SWITCH -SPST SUBSCRIPT IS TYPE OCCUPANCY SENSOR (CEILING) -SUBSCRIPT IS TYPEOS RECEPTACLE -SIMPLEX RECEPTACLE -DUPLEX, MOUNTING IN CEILINGCLG CLG GFI RECEPTACLE -DUPLEX, MOUNTING IN CEILING 1 LIGHTING ELECTRICAL LEGEND SYMBOL DESCRIPTION ABBREVIATIONS AND MISCELLANEOUS SYMBOL DESCRIPTION DEVICES AND POWER SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS # # RECEPTACLE -DUPLEX USB DEVICE RECEPTACLE W/ USB-A & USB-C PORTS DC DROP CORD WP WEATHERPROOF COVER & WEATHER RESISTANT RECEPTACLE TR TAMPER RESISTANT S SURGE PROTECTED IG ISOLATED GROUND RECEPTACLE -DOUBLE DUPLEX GFI RECEPTACLE -DOUBLE DUPLEX -SAME INDICATORS AS SHOWN FOR DUPLEX RECEPTACLE RECEPTACLE -208V R RANGE -NEMA 14-50R D DRYER -NEMA 14-30R W WELDER -NEMA 14-50R * NEMA CONFIGURATION AS NOTED 208V RECEPTACLE IN RECESSED FLOORBOX DUPLEX RECEPTACLE/GFI IN RECESSED FLOORBOX -SAME INDICATORS AS SHOWN FOR DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE/GFI IN RECESSED FLOORBOX -SAME INDICATORS AS SHOWN FOR DUPLEX RECEPTACLE J-BOX -BOX INDICATES FLOOR MOUNTING -4"X4"X2-1/8" DEEP UNLESS OTHERWISE NOTED SPECIAL PURPOSE CONNECTION -BOX INDICATES FLOOR MOUNTING -WORK AS NOTED MANUAL MOTOR DISCONNECT/STARTER SWITCH COMBINATION STARTER/DISCONNECT SWITCH DISCONNECT SWITCH CONTACTOR ELECTRIC MOTOR CONNECTION EMERGENCY PUSHBUTTON PC PHOTOCELL, PHOTOCELL WALL MOUNTEDPC TIME CLOCK M ELECTRIC METER, BUILDING MOUNTED TRANSFORMER, INTERIOR or VARIABLE FREQUENCY DRIVE J JJ CO₂ THERMOSTAT/TEMPERATURE SENSOR BY MC OR TC, J-BOX AND CONDUIT TO CEILING BY EC CARBON MONOXIDE DETECTOR BY MC, J-BOX & CONDUIT TO CEILING BY EC PP POWER POLE R RELAY CIRCUIT BREAKER CONTROL PANEL LCP LIGHTING CONTROL PANEL GMCP GENERATOR MASTER CONTROL PANEL PANELBOARD, SURFACE MOUNTED PANELBOARD, FLUSH MOUNTED TRANSFORMER, EXTERIOR M T TC VFD GFI RECEPTACLE -DUPLEX (GROUND FAULT INTERRUPT) -SAME INDICATORS AS SHOWN FOR DUPLEX RECEPTACLE ALUMINUMAL LIGHTING GENERAL NOTES A. LIGHTING CONTROLS MANUFACTURER SHALL PROVIDE SHOP DRAWINGS INDICATING ALL REQUIRED CONNECTIONS FOR RESPECTIVE MANUFACTURER'S SYSTEM. PROVIDE ALL LIGHTING CONTROLS CONNECTIONS IN ACCORDANCE WITH MANUFACTURER'S SHOP DRAWINGS. B. LOW VOLTAGE WIRING IS NOT DEPICTED ON PLAN DIAGRAMS. REFER TO MANUFACTURERS CONNECTION DIAGRAMS FOR LOW VOLTAGE REQUIREMENTS. ALL LOW VOLTAGE CABLE IS TO BE PLENUM RATED. C. CONTRACTORS WORK SHALL INCLUDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. D. WHERE OCCUPANCY SENSORS ARE SHOWN, THE MANUFACTURER SHALL PROVIDE ADEQUATE QUANTITY OF SENSORS BASED ON SPECIFIC MANUFACTURER SENSOR COVERAGE. E. FIELD VERIFY EXACT LOCATION OF EACH SENSOR. LOCATE PER MANUFACTURER'S RECOMMENDATIONS. ULTRASONIC SENSORS SHALL BE INSTALLED A MINIMUM OF 5FT FROM ANY HVAC SUPPLY OR RETURN AIR DIFFUSER. F. PROVIDE TRAINING FOR OWNER’S MAINTENANCE PERSONNEL AND DEVICE ADJUSTMENT AS REQUIRED IN SPECIFICATION 260923. G. ALL EXIT LIGHTS AND EMERGENCY SENSING LEGS FOR EMERGENCY FIXTURES SHALL BE CONNECTED AHEAD OF SWITCH LEG FOR THE LOCAL AREA CIRCUIT. WHERE MULTIPLE CIRCUITS EXIST WITHIN A SPACE, LOCAL AREA CIRCUIT SHALL BE DEFINED AS GENERAL AREA LIGHTING CIRCUIT, UNLESS NOTED OTHERWISE. POWER GENERAL NOTES A. ALL CIRCUITS SHALL CONTAIN A DEDICATED NEUTRAL CONDUCTOR. SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED. B. PROVIDE TYPED UPDATED PANEL DIRECTORIES FOR EXISTING PANELS AFFECTED BY REMODEL WORK. PROVIDE NEW CIRCUIT BREAKER NUMBER IDENTIFICATION AS REQUIRED. C. FIELD COORDINATE LOCATION OF ALL ELECTRICAL EQUIPMENT, DEVICES, AND PATHWAYS WITH STRUCTURE AND MECHANICAL AS REQUIRED TO MAINTAIN ELECTRICAL AND HVAC EQUIPMENT WORKING CLEARANCES, AND TO ENSURE EQUIPMENT SPACE REQUIREMENTS ARE MAINTAINED. D. THE CONDUCTOR SIZE CALLED OUT SHALL BE CARRIED THROUGH THE ENTIRE CIRCUIT, UNLESS OTHERWISE NOTED. E. PROVIDE TAMPER PROOF RECEPTACLES IN ALL SPACES DEFINED IN NEC ARTICLE 406. F. IT SHALL BE THE ELECTRICAL CONTRACTOR’S RESPONSIBILITY TO CONTACT THE LOCAL UTILITY COMPANY AND COORDINATE/SCHEDULE THE INSTALLATION OF THE ELECTRICAL SERVICE. ALL SERVICE CONNECTION FEES ARE THE RESPONSIBILITY OF THE OWNER.POLE BASEDIAMETERPOLE BASEDIAMETERPROJECT ANCHOR BOLTS ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND ONE BELOW BASE FLANGE). GROUT VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE. HAND FINISH. TEMPLATE TO BE FURNISHED BY POLE MANUFACTURER. PROJECT ANCHOR BOLTS ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND ONE BELOW BASE FLANGE). GROUT VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE. HAND FINISH. TEMPLATE TO BE FURNISHED BY POLE MANUFACTURER. REINFORCED CONCRETE BASE, BY ELECTRICAL CONTRACTOR SEE SITE PLAN FOR BRANCH CIRCUIT WIRING EDGE OF CURB OR PAVED AREA EDGE OF SIDEWALK BASE COVER BASE COVER REINFORCED CONCRETE BASE, BY ELECTRICAL CONTRACTOR SEE SITE PLAN FOR BRANCH CIRCUIT WIRING FINISHED GRADE LINE ANCHOR BOLTS TO BE FURNISHED BY POLE MANUFACTURER 3 -#3 TIES AT TOP OF FORM STUB SEPARATE 1" CONDUIT FOR SECURITY. EXTEND TO PULLBOX. PROVIDE STUB OUT WHEN NO CAMERA EXISTS. 1 1/2" MIN. FINISH GROUT 45 DEGREE CHAMFER BUSH CONDUIT ENDS HAND HOLE 6-#6 #3 TIES #3 TIES 6-#6 1 1/2" MIN. FINISH GROUT 45 DEGREE CHAMFER BUSH CONDUIT ENDS FINISHED GRADE LINE ANCHOR BOLTS TO BE FURNISHED BY POLE MANUFACTURER HAND HOLE 1'-7" LAP VERTICAL BARS 3 " C L R VERTICAL BARS #3 TIES @12"1'-7" LAP 3 " C L R VERTICAL BARS #3 TIES @12" (MIN. 3" LARGER THAN OUTER MOST PORTION OF BASE COVER) NOTE: PROVIDE 8' OF #6 AWG BARE COPPER WIRE WITHIN POLE BASE AND TIE TO VERTICAL/HORIZONTAL BARS AND BOND TO POLE AS REQUIRED.RESTRAINED AT BASE UNRESTRAINED AT BASE RIGID SURFACE SURROUNDS POLE AT GROUNDLINE NO RIGID SURFACE AT GROUNDLINE STUB SEPARATE 1" CONDUIT FOR SECURITY. EXTEND TO PULLBOX. PROVIDE STUB OUT WHEN NO CAMERA EXISTS. 2'-0" MIN3" 5'-6" 18" MIN30" 1 1/2" 2" 36" MAX 2'-0" MIN3" 7'-0" 18" MINMIN6" 12" MIN 36" MIN 2" 1 1/2" A. COMPLY WITH THE LATEST ADOPTED VERSION OF NEC, ENERGY CODE, AND ANY OTHER LOCAL CODES/STANDARDS. B. REFER TO AND COMPLY WITH DETAILS LISTED IN THE PROJECT SPECIFICATIONS DOCUMENT. C. ITEMS SHOWN IN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. ITEMS SHOWN IN HEAVY LINEWEIGHT ON NEW PLANS, ARE ALL NEW OR RELOCATED UNLESS NOTED OTHERWISE. D. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE: ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR. E. INFORMATION ON DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS AND/OR FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, PRIOR TO BID, AND BECOME FAMILIAR WITH THE EXTENT OF THE WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT DOCUMENTS. F. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER. G. REFER TO SPECIFICATION 260533 FOR EXPOSED AND CONCEALED RACEWAY REQUIREMENTS. H. ALL WORK REQUIRING BUILDING SHUTDOWN TO EXISTING AND OPERATING PORTIONS OF THE BUILDING SHALL BE COORDINATED IN WRITING WITH BUILDING OWNERS’ REPRESENTATIVE MINIMUM 10-DAYS PRIOR TO SHUTDOWN. COMMON WORK GENERAL NOTES I. ELECTRICAL CONTRACTOR SHALL MAINTAIN FIRE RATINGS FOR ALL CONDUIT AND BOX PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION. SEAL ALL PENETRATIONS OF RATED WALLS PER SPECIFICATIONS. SEE ARCHITECTURAL DRAWINGS FOR WALL RATINGS AND LOCATIONS. J. COORDINATE PATHWAYS AND LOCATIONS OF ALL DEVICES INSTALLED WITHIN CASEWORK WITH SHOP DRAWINGS PRIOR TO ROUGH-IN AND INSTALLATION. K. CONTRACTOR SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL MEMBERS OR STRUCTURAL TOPPING SLABS OF FLOORS, UNLESS NOTED OTHERWISE AND COORDINATED WITH STRUCTURAL. DRAWINGS INDICATE GENERAL DIRECTIONS AND ROUTES, FIELD COORDINATE EXACT ROUTE AND INSTALLATION OF CONDUIT WITH CONDITIONS OF CONSTRUCTION. L. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET HEIGHTS WHERE THE SPECIFIC OUTLET HEIGHT IS NOT INDICATED ON THE DRAWING.REFER TO THE ELECTRICAL LEGEND FOR THE DEFAULT OUTLET HEIGHT WHEN NOT INDICATED ON ELEVATIONS OR ON THIS SHEET. M. ADA COMPLIANCE: ELECTRICAL DEVICES PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27” AND 80”AFF SHALL PROTRUDE NO MORE THAN 4”INTO WALKS OR CORRIDORS. N. ALL SPARE CONDUITS SHALL CONTAIN A PULL CORD. EACH END OF THE CONDUIT SHALL HAVE A LABEL IDENTIFYING THE TERMINATION POINT OF THE OPPOSITE END OF THE CONDUIT. O. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATION. ANY DAMAGE TO THE EXISTING UTILITY SHALL BE REPAIRED AT THE CONTRACTOR’S EXPENSE. P. CONTRACTOR IS RESPONSIBLE FOR ALL TRENCHING, PATCHING, EXCAVATION, BACKFILL, AND RESTORATION RELATED TO THEIR WORK. REVISIONS 5/14/2026 2:08:57 PM ELECTRICAL LEGENDS AND GENERAL NOTES E001 | Project# URSUS_MAJ | L:\URSUS_MAJ\BIMCAD\Revit 05.18.2026 © 2026 | ALL RIGHTS RESERVED SITE PLAN URSUS_MAJORBOZEMAN, MTLATTICE MATERIALSPROJ# | URSUS_MAJ DESIGNED BY | HESTAND DRAWN BY | REOPELLE REVIEWED BY | BRONEC TI LIGHTING FIXTURE SCHEDULE TYPE FIXTURE LIGHT SOURCE OPTIONS DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING VOLTAGE VA FINISH CRI KELVIN LUMENS EMERGENCY DIMMABLELOCATION TYPE HEIGHT <varies> <varies> <varies> <varies> <varies> <varies> <varies> <varies> <varies> <varies> <varies> <varies> C1 FRONT CANOPY DOWNLIGHT GOTHAM IVO4 D 15LM 30K 80CRI WD MIN1 MVOLT ZT NCH WL P AR LSS FWR CEILING RECESSED - 277 V 15.00 SEMI SPECULAR 80 3000 0 lm 1% 0-10V LN1 LINEAR - STORAGE/MECH/ELEC LITHONIA CLX L48 4000LM SEF FDL MVOLT GZ10 35K 90CRI WH - ZAC120 CEILING PENDANT 9' 0" 277 V 31.80 WHITE 90 3500 0 lm 10% 0-10V NOT TO SCALEE001 1 SITE POLE BASE DETAIL 03.06.2026 05.15.2026 CITY COMMENTS # 1