HomeMy WebLinkAbout027.2 - L505 - LANDSCAPE ROOF DETAILS1L505ROOFTOP PEDESTAL CONCRETE PAVERS 1 1/2"=1'-0"NOTE:1.ROOFTOP CONCRETE PAVERS TO BE 24" X 24" X 1 34" to 3" V-SERIES EXPRESSION XP-50 PAVERS ASMANUFACTURED BY WAUSAUTILE.COM. INSTALL ON MANUFACTURER'S PEDESTAL SYSTEM FORSLOPING ROOF.2.INSTALL AS PER MANUFACTURER'S WRITTEN RECOMMENDATIONS.3.SEE ARCHITECTURE FOR FINISH GRADE ELEVATION.4.SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.5.PROVIDE SAMPLES FOR COLOR VERIFICATION.SEE ARCH.FLOWSCH. 80 T.O.E. NIPPLE (2)PVC MAINLINE PIPE & FITTINGS12" X 18" VALVE BOX AS SPECIFIED,CUT BOTTOM AS NOTEDWATERPROOF CONNECTORS (2)18-24" COILED WIRENOTE:1.INSTALL PER MANUF.'S WRITTEN INSTRUCTIONS.2.ROTATE TO LAY FLAT FOR LOWEST PROFILE (NOT SHOWN).3.CUT VALVE BOX TO AS CLOSE TO FLUSH WITH FINISH GRADE AS POSSIBLE WHILE MAINTAINING DRIPZONE CONTROL KIT OPERABILITY. OPTION TO USE ACCESS BOX AS SPECIFIED.DRIP ZONE CONTROL KIT, AS NOTEDFINISH GRADE, FILL TO FLUSH AT BOXPVC SLIP UNIONS (2)TRAY-TYPE VEG. ROOFSYSTEM APPLICATIONROOFTOP SOIL RETAINER AND ADJACENT FINISH GRADE, FILLAND COVER PIPE WITH SOIL GROWING MEDIA5L505ROOFTOP DRIP ZONE CONTROL KIT 1 1/2"=1'-0"INSTALL PIPING PER TRAY-TYPE VEG. ROOF SYSTEM MANUF.RECOMMENDATIONS FOR SUBTERRANEAN IRRIGATIONTRAY-TYPE VEG. ROOFSYSTEM APPLICATIONROOFTOP BALLASTAPPLICATIONCOMPOSITE GEOTEXTILE, SEE ARCH.INSULATION, SEE ARCH.ROOFTOP SOIL RETAINER AND ADJACENT FINISH GRADE, FILLAND COVER PIPE WITH SOIL GROWING MEDIAINSTALL PIPING PER TRAY-TYPE VEG. ROOF SYSTEM MANUF.RECOMMENDATIONS FOR SUBTERRANEAN IRRIGATIONQUICK COUPLING VALVE AS NOTEDAND SPECIFIEDFINISH GRADE, FILL TO FLUSH ATBOX WHERE FEASIBLE9" ROUND VALVE BOX AS SPECIFIED,CUT BOTTOM AS NOTEDSWING JOINT, LENGTH AS REQUIREDFILL BOX WITH BALLAST TO SUPPORTVALVEPVC MAINLINE PIPE & FITTINGSWATERPROOF MEMBRANE, SEE ARCH.INSULATION, SEE ARCH.NOTE:1.INSTALL PER MANUF.'S WRITTEN INSTRUCTIONS.2.ROTATE, IF ALLOWABLE, FOR LOWEST PROFILE (NOT SHOWN).3.CUT VALVE BOX TO AS CLOSE TO FLUSH WITH FINISH GRADE AS POSSIBLE WHILE MAINTAINING QUICKCOUPLER VALVE OPERABILITY. OPTION TO USE ACCESS BOX AS SPECIFIED.10L505ROOFTOP QUICK COUPLER VALVE 1 1/2"=1'-0"TRAY-TYPE VEG. ROOFSYSTEM APPLICATIONROOFTOP MINERALMULCH/BALLAST APPLICATIONPVC MAINLINE PIPE & FITTINGSWATERPROOF MEMBRANE, SEE ARCH.INSULATION, SEE ARCH.NOTE:1.INSTALL PER MANUF.'S WRITTEN INSTRUCTIONS.2.ROTATE, IF ALLOWABLE, FOR LOWEST PROFILE (NOT SHOWN).3.CUT VALVE BOX TO AS CLOSE TO FLUSH WITH FINISH GRADE AS POSSIBLE WHILE MAINTAINING MANUALISOLATION VALVE OPERABILITY. OPTION TO USE ACCESS BOX AS SPECIFIED.6L505ROOFTOP MANUAL ISOLATION VALVE 1 1/2"=1'-0"ROOFTOP BALLASTAPPLICATIONROOFTOP MANUAL ISOLATION VALVEAS NOTED AND SPECIFIED12" ROUND VALVE BOX AS SPECIFIED,CUT BOTTOM AS NOTEDFINISH GRADE, TYP.ROOFTOP SOIL RETAINER AND ADJACENT FINISH GRADE, FILLAND COVER PIPE WITH SOIL GROWING MEDIAINSTALL PIPING PER TRAY-TYPE VEG. ROOF SYSTEM MANUF.RECOMMENDATIONS FOR SUBTERRANEAN IRRIGATIONSCHED. 80 PVC UNION (2)TOPVIEWWATERPROOF MEMBRANE, SEE ARCH.INSULATION, SEE ARCH.NOTE:1.INSTALL PER MANUF.'S WRITTEN INSTRUCTIONS.2.ROTATE, IF ALLOWABLE, FOR LOWEST PROFILE (NOT SHOWN).3.CUT VALVE BOX TO AS CLOSE TO FLUSH WITH FINISH GRADE AS POSSIBLE WHILE MAINTAINING DRAIN VALVEOPERABILITY. OPTION TO USE ACCESS BOX AS SPECIFIED.4.CONNECT ADDITIONAL PIPING AND DIRECT TORWARD ROOF DRAIN AS REQUIRED.7L505ROOFTOP DRAIN VALVE 1 1/2"=1'-0"TRAY-TYPE VEG. ROOFSYSTEM APPLICATIONROOFTOP MINERALMULCH/BALLAST APPLICATIONFINISH GRADEMAINLINE WITH 1" TEE ON SIDE12" ROUND VALVE BOX AS SPECIFIED,CUT BOTTOM AS NOTED2" PVC RISER, LENGTH AS REQUIRED1" GATE VALVE (FOR DRAINING), SEE DETAILMAINLINE WITH 1" TEE ON SIDE9L505ROOFTOP MANUAL LINE FLUSHING VALVE 1 1/2"=1'-0"7" ROUND VALVE BOX AS SPECIFIEDNOTE:1.INSTALL PER MANUF.'S WRITTEN INSTRUCTIONS.2.ROTATE, IF ALLOWABLE, FOR LOWEST PROFILE (NOT SHOWN).3.CUT VALVE BOX TO AS CLOSE TO FLUSH WITH FINISH GRADE AS POSSIBLE WHILE MAINTAINING DRAINVALVE OPERABILITY. OPTION TO USE ACCESS BOX AS SPECIFIED.4.INSTALL ONE ROOFTOP MANUAL LINE FLUSHING VALVE ON EACH IN-LINE EMITTER DRIP LINE LOOP.FINISH GRADE, TYP.DRIP LINE TUBING, TYP.ROOFTOP MANUAL LINE FLUSHING VALVE, ASNOTEDPLANVALVE BOX, SEE SECTIONDRIP LINE TUBING LATERAL, TYP.ROOFTOP MANUAL LINEFLUSHING VALVE, SEE SECTIONVALVE BOX AS NOTEDGATE VALVETRAY-TYPE VEG. ROOFSYSTEM APPLICATIONROOFTOP MINERALMULCH/BALLAST APPLICATIONWATERPROOF MEMBRANE, SEE ARCH.COMPOSITE GEOTEXTILE, SEE ARCH.ROOFTOP WALKWAYPAVERS, AS NOTED, FLUSHWITH FINISH FLOOR TYP.ADJUSTABLE PEDESTALWITH BUILT-IN SPACERFOR UNIFORM SPACEBETWEEN PAVERS, TYP.GEOTEXTILE, TYP.WATERPROOFMEMBRANE, TYP.TAPEREDINSULATION, TYP.2.98" 6" SEE ARCH.WATERPROOFMEMBRANE, TYP.TAPERED INSULATION,TYP.PLANTS, MIN. 95% SOILCOVERAGE AT INSTALLATIONENGINEERED SOIL, TYP.INSTALL FLUSH W/ TOP OFPAVER ELEVATIONTRAY-TYPE VEGETATEDROOF ASSEMBLY, TYP.IRRIGATION IN-LINE EMITTERDRIP LINE, TYP.SEE ARCH.GEOTEXTILE, TYP.TAPEREDINSULATION, TYP.ROOFTOP SOILRETAINER, AS NOTED,TYP.TRAY-TYPE VEGETATED ROOFASSEMBLY OR OTHER MULCH/BALLASTMATERIAL, SEE DETAIL, TYP.2L505ROOF ASSEMBLYTRAY-TYPE VEGETATED 1 1/2"=1'-0"NOTE:1.TRAY-TYPE VEGETATED ROOF ASSEMBLY TO BE 1' X 2' X 6" DEEP MODULE AS MANUFACTURED BY LIVEROOF,WWW.LIVEROOF.COM. INSTALL AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS.1.1.PROVIDE SEDUM MIX FOR APPROVAL.1.2.INSTALL ASSEMBLY TO UNIFORM ELEVATION TO PAVERS AT PAVER TRANSITION.2.SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION..3.SEE TYPICAL DRIP LINE LAYOUT WITHIN TRAY-TYPE VEGETATED ROOF ASSEMBLY DETAIL FOR ADDITIONALIRRIGATION INFORMATION.ROOFTOP WALKWAYPAVERS, SEE DETAIL,TYP.3L505ROOFTOP SOIL RETAINER 1 1/2"=1'-0"NOTE:1.ROOFTOP SOIL RETAINER TO BE 'L' SHAPED MATERIAL AS SPECIFIED WITH MILL FINISH. RETAINERTO BE COMPATIBLE AND FLUSH WITH TRAY-TYPE VEGETATED ROOF ASSEMBLY AND WALKWAYPAVERS. HEIGHT OF RETAINER MAY VARY WITH SLOPING ROOF SYSTEM.2.INSTALL AROUND PERIMETER OF ALL TRAY-TYPE VEGETATED ROOF ASSEMBLY AND ALLROOFTOP WALKWAY PAVER ASSEMBLY LOCATIONS.3.SEE ROOFTOP MINERAL MULCH/BALLAST DETAIL FOR PAVER TO MINERAL MULCH TRANSITION.4.INSTALL AS PER MANUFACTURER'S WRITTEN RECOMMENDATIONS.5.SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.ROOFTOP PAVER TO TRAYAPPLICATIONTRAY TO ROOFTOPBALLAST APPLICATIONWATERPROOFMEMBRANE, TYP.GEOTEXTILE, TYP.WITHIN TRAY-TYPE VEG. ROOF ASSEMBLYTYPICAL DRIPLINE LAYOUT SCALE: NOT TO SCALE8L505NOTE:1.SEE SCHEMATIC DRIP LAYOUT DETAIL. SEE LEGEND FOR MODEL AND MANUF. INSTALL IRRIGATIONSYSTEM PER MANUFACTURE'S. WRITTEN INSTRUCTIONS.2.LENGTH OF IN-LINE EMITTER DRIP LINE NOT TO EXCEED 500' BEFORE CONNECTION BACK TO LATERALSUPPLY LINE3.COORDINATE INSTALLATION WITH TRAY-TYPE VEG. ROOF ASSEMBLY'S MANUFACTURER REQUIREMENTSAND ACCOMMODATIONS. SEE TRAY-TYPE VEGETATED ROOF ASSEMBLY DETAIL.4.OVERHEAD (INCL. SPRAY/ROTOR) IRRIGATION NOT ALLOWED.LFTRAY-TYPE VEGETATED ROOFMODULE, TYP, SEE DETAILLATERAL SUPPLY PVC PIPE,MINIMIZE VISIBILITY. PLACEBELOW, ADJACENT OR THRUMODULEROOFTOP DRIP ZONECONTROL KIT, SEE DETAILIN-LINE EMITTER DRIP LINE THRUMODULES AND AS NOTED±1'-0"±1'-0" TYP.TYP.NOTE:1.IF WATER SOURCE NOT LOCATED IN PLANTING AREA, EXTEND LINE TO NEARESTPLANTER TO INSTALL VALVE BOXES.2.LOCATE VALVE BOXES TO REDUCE VISIBILITY.3.VALVE BOX SIZES MAY BE SIZED SMALLER TO REDUCE VISIBILITY. VALVES MUSTBE OPERABLE.4.VALVES MAY BE ROTATED, BUT MUST BE OPERABLE.4L505POINT OF CONNECTIONROOFTOP SCHEMATIC IRRIGATION 1/2"=1'-0"1" WATER SOURCE AND BACKFLOW PREVENTER,PROVIDED BY PLUMBING CONTRACTORUNIFORM HEIGHT OF ALL VALVE BOXESWHEN IN SAME PLANTING AREA AND/ORCLOSE PROXIMITY. BASE HEIGHT ONHIGHEST REQUIRED VALVE BOX.ROOFTOP QUICKCOUPLERROOFTOP MANUALISOLATION VALVEROOFTOP DRAIN VALVE6L50510L5057L505TYP. LOCATE AT MAINLINELOW POINTSTYP.TYP.ROOFTOP MANUALLINE FLUSHING VALVEAT EACH END OFLATERAL LINE9L505©| ALL RIGHTS RESERVED®DRAWN BY |REVISIONSREVIEWED BY |DESIGNED BY |PROJ# |URSUS_MAJOR BOZEMAN, MT LATTICE MATERIALS2026SITE PLAN03.06.2026URSUS_MAJSTA T E OF MONTANALANDSCAPE ARCHI T ECT DEBRALICENSED264ANN-LESLIEROSA05.15.2026 CITY COMMENTS # 105.15.26 9:53 AM | L:\URSUS_MAJ\BIMCAD\LandArch\URSUS_MAJ_L503-L505.dwgL505LANDSCAPE ROOFDETAILSROSADAWSONROSA