HomeMy WebLinkAbout027 - L503 - IRRIGATION DETAILSNOTES:1.TAPE & BUNDLE ALL WIRING AT10'-0" INTERVALS.2.TIE A LOOSE 20" LOOP INWIRING AT ALL CHANGES INDIRECTION GREATER THAN 30°UNTIE ALL LOOPS AFTERMAKING CONNECTIONS.3.BURY MARKING TAPE 6" ABOVEALL DIRECT BURIAL WIRING,LATERAL LINES, AND MAINLINE.4.ALL WIRING UNDER PAVEMENTSHALL BE THROUGH SLEEVES-SEE DETAIL.5.ALL SPLICES SHALL BE MADE INVALVE BOXES AND LOCATED ONAS-BUILT PLANS.TYPICAL SECTIONOF A SHARED TRENCH18" MIN. DEPTH4"MIN.FINISH GRADELATERALMAINLINELOW VOLTAGEWIRE IN CONDUITIF APPLICABLEBEDDING ASSPECIFIEDBACKFILL WITHEXCAVATIONMATERIAL REMOVEDFROM TRENCH12" MIN. DEPTH1L503IRRIGATION TRENCH1"=1'-0"6" MARKERTAPE, TYP.2" MIN.COVER NOTES:1.ALL IRRIGATION SLEEVINGSHALL BE (2) SIZES LARGERTHAN PIPE OR COMBINATIONOF PIPES THEREIN ENCLOSED,WITH MINIMUM SIZE TO BE 4"SCHEDULE 40 PVC.2.SUPPLY (1) EXTRA SLEEVEWITH EACH IRRIGATIONSLEEVE FOR CONTROL WIRES.BORE UNDER EXISTINGPAVING WHERE REQUIRED.BORE SEPARATELY FORCONTROL WIRES.3.BURY MARKING TAPE ABOVEALL SLEEVES 6" BELOWPAVEMENT.4.INSTALL 3" HT IRRIGATION "I"STAMP IN PAVEMENT WHERESLEEVES ARE LOCATEDUNDER NEW PAVEMENT.5.WHEN TRENCHING PROVIDEA 4" CLEARANCE AROUNDSIDES OF SLEEVES. SLOPESIDES OF TRENCH PER OSHASPECIFICATIONS.SECTION2'-0"4"MIN.FINISH GRADEIRRIGATION SLEEVECONTROLLERWIRE SLEEVEIF APPLICABLEBEDDING ASSPECIFIEDBACKFILL WITHEXCAVATIONMATERIAL REMOVEDFROM TRENCH6"4" MIN.2L503IRRIGATION SLEEVE1"=1'-0"6" MARKERTAPE, TYP.6" MIN.6" MIN.18"TYP.NEAREST JOINTIF APPLICABLESTAMPED LETTERPAVEMENTPAVEMENT EDGEPLANEXTENDSLEEVE 1'-0"BEYONDPAVEMENT IRRIGATION SLEEVE2" MIN.COVER 3L503WATER POINT OF CONNECTION AT BUILDINGNTSBPFSISOLATION VALVE, TYP.-SEE DETAILBACKFLOW PREVENTOR-SEE PLUMBINGQUICK COUPLER, TYP.-SEE DETAILDOMESTIC WATERFROM BUILDINGIRRIGATION MAINLINEBUILDING WALLNOTES:1.CONNECTION ASSEMBLY INFORMATIONSHOWN IS SCHEMATIC ONLY.2.SEE IRRIGATION PLAN, SPECIFICATION,AND LEGEND FOR MORE INFORMATION.3.COORDINATE BACKFLOW PREVENTORAND MAINLINE SIZE WITH PLUMBING ASNECESSARY.4.LOCATE ADDITIONAL QUICK COUPLERSAS REQUIRED FOR WINTERIZATIONCONNECTIONS.9L50310L503MASTER VALVE(ELECTRICCONTROL VALVE)FLOW SENSOR7L503MANUAL DRAINNOTES:1.VALVE TO BESUPPORTED BYGRAVEL, PROVIDEBLOCK SHIM ASREQUIRED.2.SIZE VALVE ANDPIPING ASSPECIFIED.3.WHEREVERPOSSIBLE INSTALLVALVE BOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.5L503ISOLATION VALVE1 1/2"=1'-0"FINISH GRADEGATE OR BALLVALVEVALVE BOX3/4" CRUSHEDMINUS GRAVELBRICK SUPPORTS,TYP.MAINLINEVALVE BOXEXTENSION, TYP.ADD AS NECESSARYVALVE BOX COVERSCHEDULE 80PVC UNION, TYP.NOTES:1.DOUBLE SWING JOINT SHALL BESCHEDULE 80 PVC NIPPLE WITH(3) MARLEX STREET ELBOWS.2.WHEREVER POSSIBLE INSTALLVALVE BOXES IN PLANTINGBEDS. SEE IRRIGATION PLANFOR MORE INFORMATION.MAINLINE6L503QUICK COUPLER1 1/2"=1'-0"BRICK SUPPORTS,TYP.FINISH GRADEQUICK COUPLERVALVE BOX WITH COVER3/4" CRUSHEDMINUS GRAVEL24" #4 REBAR WITH CLAMPSDOUBLE SWING JOINTMAIN LINE TEE OR ELLMAINLINE7L503MANUAL DRAIN1"=1'-0"FINISH GRADEPVC SCHEDULE 80 FITTINGSAND SCHEDULE 80THREADED NIPPLES, TYP.1" BRONZE BALL ORGATE VALVEGRAVEL SUMP WITH A MIN.3 CUBIC YARDS OF1 1/2 " WASHED AGGREGATE WRAPPED IN FILTER FABRICAS SPECIFIED10" ROUND VALVE BOX3/4" CRUSHEDMINUS GRAVELMAINLINE WITH 1" TEEON BOTTOM6" DIA. PVC RISER,LENGTH AS REQUIRED4" MIN.NOTES:1.INSTALL MANUALDRAIN AT LOWESTPOINT ON MAINLINE.2.RISER TO BESUPPORTED BYGRAVEL.3.VALVE AND PIPINGAS SPECIFIED.4.WHEREVERPOSSIBLE INSTALLVALVE BOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.SCHEDULE 80 PVCUNION, TYP.NOTES:1.VALVE TO BESUPPORTED BYGRAVEL, PROVIDEBLOCK SHIM ASREQUIRED.2.SIZE VALVE AND PIPINGAS SPECIFIED.3.DIRECT BURIAL WIREMIN. 18/4 WIRE TOINTERFACE PANEL. MIN.RUN OF 1,000 LF4.WHEREVER POSSIBLEINSTALL VALVE BOXESIN PLANTING BEDS. SEEIRRIGATION PLAN FORMORE INFORMATION.CONTROL VALVEBRICK SUPPORTS, TYP.SCHEDULE 80 PVCUNION, TYP.DECODER SYSTEMIF APPLICABLEMAINLINE3/4" CRUSHED MINUS GRAVELSERVICE TEE9L503ELECTRIC CONTROL VALVE1 1/2"=1'-0"FINISH GRADEVALVE BOX COVER3M DBY-6 WATERPROOFCONNECTOR, TYP.18"-24" OF COILED WIREDISTRIB.PIPING10L503FLOW SENSOR3/4"=1'-0"FLOWSENSORNOTES:1.INSTALL FLOW SENSOR ALONGMAINLINE AFTER MASTER VALVE ANDACCORDING TO MANUF. WRITTENSPECIFICATIONS.2.SIZE FLOW SENSOR BASED UPONREQUIRED GPM NEEDED FORPROJECT. SIZE VALVE AND PIPING ASSPECIFIED.3.INLET PIPE LENGTH OF SENSOR MUSTBE MIN. 10X PIPE DIA. STRAIGHT,CLEAN RUN OF PIPE, NO FITTINGS ORTURNS. OUTLET PIPE LENGTH OFSENSOR MUST ME MIN. 5X PIPE DIA.OF STRAIGHT CLEAN RUN OF PIPE,NO FITTINGS OR TURNS.4.DIRECT BURIAL WIRE MIN. 18/4 WIRETO INTERFACE PANEL. MIN. RUN OF1,000 LF.5.WHEREVER POSSIBLE INSTALL VALVEBOXES IN PLANTING BEDS. SEEIRRIGATION PLAN FOR MOREINFORMATION.INLET MIN. LENGTH10X PIPE DIA.FINALGRADEOUTLETMIN. LENGTH5X PIPE DIA.18"-24" OF COILED WIRE3M DBY-6 WATERPROOFCONNECTOR, TYP.MASTERVALVE(SEEELECTRICCONTROLVALVE)MAINLINENOTES:1.INSTALL VALVE AT HIGHESTPOINT ON MAINLINE.2.VALVE TO BE BRACED BYGRAVEL, PROVIDE REBARSTAKING AS REQUIRED.3.SIZE VALVE AND PIPING ASSPECIFIED.4.WHEREVER POSSIBLE INSTALLVALVE BOXES IN PLANTINGBEDS. SEE IRRIGATION PLANFOR MORE INFORMATION.11L503AIR RELIEF VALVE1 1/2"=1'-0"FINISH GRADEPVC UNIONVALVE BOX3/4" CRUSHEDMINUS GRAVELBRICK SUPPORTS, TYP.SERVICE TEEMAINLINEVALVE BOX COVERBERMAD AIR RELEASE VALVEOR APPROVED EQUALBALL VALVENOTES:1.SEE IRRIGATIONSPECIFICATION AND LEGENDFOR MORE INFORMATION.2.INSTALLATION TO BECOMPLETED IN ACCORDANCEWITH MANUFACTURER'SSPECIFICATIONS.3.MOUNT CONTROLLER AT EYELEVEL UNLESS OTHERWISENOTED.4.CONTROLLER SHALL BEHARD-WIRED TO GROUNDED110 VAC SOURCE UNLESSOTHERWISE NOTED.COORDINATE INSTALLATIONWITH ELECTRICAL.5.PROVIDE IRRIGATION ZONELIST AS SPECIFIED.4L503CONTROLLER1 1/2"=1'-0"ENSURE MINIMUMCLEARANCE FORDOOR OPENINGCONTROLLERCONDUITCONTROL WIREINTERIOR OREXTERIOR WALL-SEE PLANIRRIGATIONZONE LISTCONTROLLERPOWER SOURCENOTES:1.SEE IRRIGATIONSPECIFICATION AND LEGENDFOR MORE INFORMATION.2.INSTALLATION TO BECOMPLETED INACCORDANCE WITHMANUFACTURER'SSPECIFICATIONS.3.MOUNT WEATHER STATIONWITH CLEAR EXPOSURE TOWEATHER IN LOCATIONSHOWN ON PLANS. MOUNTWITH COMMON SENSE SOAS TO NOT TO VISUALLYDETRACT FROM ITSSURROUNDINGS.4.MOUNT RECEIVER IFAPPLICABLE ON WALL NEXTTO CONTROLLER.5.MOUNT MODULE IFAPPLICABLE WITHIN 6'-0" OFCONTROLLER ON WALL.8L503WEATHER STATION1 1/2"=1'-0"IRRIGATIONCONTROLLERUP TO 800' AWAY IF WIRELESSWIRELESSRECEIVERIF APPLICABLESUPPORTINGMODULE IFAPPLICABLEMOUNTING BRACKETWEATHER STATIONEXTERIOR SECTIONSCALE: 1/4" =1'-0EXTERIOR WALL OR POLEEXTERIOR OR INTERIOR WALLVIEW10'-0" MIN. PER MANUFACTURER MFNOTE:1.PLACE TREES IN LAWN AREAS ONSEPARATE ZONE.EMITTER 1 GPH (4) PERTREE AND (2) PER SHRUBTREE OR SHRUBPLANTING, SEE DETAILDRIP MANUAL DRAIN,SEE DETAILDRIP LINE STARTCONNECTION, SEE DETAIL12L503TREE WATERING IN GRASS SCALE = 1/2"=1'-0"EDGING, TYP.©| ALL RIGHTS RESERVED®DRAWN BY |REVISIONSREVIEWED BY |DESIGNED BY |PROJ# |URSUS_MAJOR BOZEMAN, MT LATTICE MATERIALS2026SITE PLAN03.06.2026URSUS_MAJSTA T E OF MONTANALANDSCAPE ARCHI T ECT DEBRALICENSED264ANN-LESLIEROSA05.15.2026 CITY COMMENTS # 105.15.26 9:47 AM | L:\URSUS_MAJ\BIMCAD\LandArch\URSUS_MAJ_L503-L505.dwgL503IRRIGATIONDETAILSROSADAWSONROSA