Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
026 - L502 - LANDSACPE DETAILS
1L502DECIDUOUS TREE PLANTING1/4" = 1'-0"NOTES:1.SEE PLANTING GENERAL NOTESFOR MORE INFORMATION.2.REMOVE ALL TWINE, STRING,AND WIRE FROM ROOTBALL.REMOVE BURLAP FROM TOPTHIRD OF ROOTBALL.3.THE ROOT FLARE OF ALL TREESSHALL BE LEVEL WITH OR UP TO1" ABOVE GRADE.4.ALL TREES SHALL BE INSTALLEDWITH A TEMPORARY SAUCER OFRAISED SOIL AT THE EDGE OFROOT BALL TO CONTAIN WATER.REMOVE OR BREACH WATERSAUCER BEFORE WINTER.5.PULL MULCH AWAY FROMTRUNK A MINIMUM OF 6".6.PROVIDE A 3'-6" MINIMUM MULCHRADIUS AROUND TREES INGRASS AREAS.STAKE, TYP.-SEE PLANTING NOTESEDGING AS SPECIFIEDMULCH AS SPECIFIEDWEED BARRIER FABRICIF APPLICABLE AND ASSPECIFIEDPLANTING SOIL AS SPECIFIEDPLACE ROOT BALL ONRAISED RING OFUNDISTURBED NATIVE SOILROOT FLAREFINISH GRADETEMPORARYWATER SAUCERTREE TIE, TYP.-SEE PLANTING NOTES2L502CONIFEROUS TREE PLANTING1/4" = 1'-0"NOTES:1.SEE PLANTING GENERAL NOTESFOR MORE INFORMATION.2.REMOVE ALL TWINE, STRING,AND WIRE FROM ROOTBALL.REMOVE BURLAP FROM TOPTHIRD OF ROOTBALL.3.THE ROOT FLARE OF ALL TREESSHALL BE LEVEL WITH OR UP TO1" ABOVE GRADE.6.ALL TREES SHALL BE INSTALLEDWITH A TEMPORARY SAUCER OFRAISED SOIL AT THE EDGE OFROOT BALL TO CONTAIN WATER.REMOVE OR BREACH WATERSAUCER BEFORE WINTER.7.PULL MULCH AWAY FROMTRUNK A MINIMUM OF 6".8.PROVIDE A 3'-6" MINIMUM MULCHRADIUS AROUND TREES INGRASS AREAS.9.TREE STAKES MAY BEINSTALLED AT 45° ANGLE.STAKE, TYP.-SEE PLANTING NOTESEDGING AS SPECIFIEDMULCH AS SPECIFIEDWEED BARRIER FABRICIF APPLICABLE AND ASSPECIFIEDPLANTING SOIL AS SPECIFIEDPLACE ROOT BALL ONRAISED RING OFUNDISTURBED NATIVE SOILROOT FLAREFINISH GRADETEMPORARYWATER SAUCERTREE TIE, TYP.-SEE PLANTING NOTES4'-0"2'-0"EXCAVATE HOLE: WIDTH = 3X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALLEXCAVATE HOLE: WIDTH = 3X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALL6"3'-0" MIN.6"4'-0"2'-0"3'-0" MIN.3L502SHRUB PLANTING1"=1'-0"NOTES:1.SEE PLANTING GENERALNOTES FOR MOREINFORMATION.2.REMOVE ALL ROOTCONTAINMENT MATERIALSFROM ROOTBALL.3.THE ROOT FLARE OF ALLSHRUBS SHALL BE LEVEL WITHOR UP TO 1" ABOVE GRADE.6.ALL SHRUBS SHALL BEINSTALLED WITH ATEMPORARY SAUCER OFRAISED SOIL AT THE EDGE OFROOT BALL TO CONTAINWATER. REMOVE OR BREACHWATER SAUCER BEFOREWINTER.7.PULL MULCH AWAY FROMROOT FLARE 3".EDGING AS NOTEDMULCH AS SPECIFIEDWEED BARRIER FABRICIF APPLICABLE AND ASSPECIFIEDPLANTING SOIL AS SPECIFIEDPLACE ROOT BALLON RAISED RINGOF UNDISTURBEDNATIVE SOILROOT FLAREFINISH GRADETEMPORARY WATERSAUCER AS NOTED4L502PERENNIAL PLANTING1"=1'-0"NOTES:1.SEE PLANTING GENERAL NOTESFOR MORE INFORMATION.2.REMOVE ALL ROOT CONTAINMENTMATERIALS FROM ROOTBALL.3.THE CROWN OF THE ROOT MASSOF ALL PERENNIALS SHALL BELEVEL WITH OR UP TO 1" ABOVEGRADE.4.ALL PERENNIALS SHALL BEINSTALLED WITH A TEMPORARYSAUCER OF RAISED SOIL AT THEEDGE OF ROOT MASS TO CONTAINWATER. REMOVE OR BREACHWATER SAUCER BEFORE WINTER.5.PULL MULCH AWAY FROM ROOTMASS A MINIMUM OF 3".MULCH AS SPECIFIEDWEED BARRIER FABRICIF APPLICABLE AND ASSPECIFIEDPLANTING SOIL AS SPECIFIEDPLACE ROOT BALLON RAISED RINGOF UNDISTURBEDNATIVE SOILCROWN OFROOT MASSFINISH GRADETEMPORARY WATERSAUCER AS SPECIFIEDEXCAVATE HOLE: WIDTH = 2X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALL6" MIN.EXCAVATE HOLE: WIDTH = 2X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALL6" MIN.3"3"X XX = PLANT SPACINGSEE PLANTING SCHEDULE FOR SPACING REQUIREMENTSY = SPACING BETWEEN ROWSMULTIPLY X VALUE BY 0.86 OR 87%PLANT MATERIAL, TYP.5L502PLANTING LAYOUT1/2"=1'-0"EDGING AS NOTEDOUTSIDE ROW OF PLANTMATERIAL SHALL FOLLOWBED EDGE -SEE PLANTING PLAN.SPACING SHALL NOT EXCEED X.Y6L502SHOVEL CUT EDGING1"=1'-0"MULCH AS SPECIFIEDWEED BARRIER FABRIC IF APPLICABLEAND AS SPECIFIEDFINISH GRADEDEPTH AS SPECIFIED7L502LANDSCAPE EDGING1"=1'-0"MULCH AS SPECIFIEDWEED BARRIER FABRIC IF APPLICABLEAND AS SPECIFIEDPLANTING SOIL AS SPECIFIEDUNDISTURBED NATIVE SOILFINISH GRADEFABRIC STAPLES AS SPECIFIEDDEPTH AS SPECIFIEDPLANTING SOIL AS SPECIFIEDUNDISTURBED NATIVE SOILFABRIC STAPLES AS SPECIFIEDTAPER PLANTING SOIL AT EDGE TO KEEP1 1/2" BELOW FINISH GRADELANDSCAPE EDGING AS SPECIFIEDTAPER PLANTING SOIL AT EDGE TO KEEP1 1/2" BELOW FINISH GRADESHOVEL CUT EDGE AT 45° ANGLE.12"1'-0"112" 112"1'-0"8L502BOULDER1/2"=1'-0"DO NOT SCAR ORDAMAGE BOULDERFINISH GRADECOMPACTEDSUBGRADE AS SPECIFIEDUNDISTURBEDNATIVE SOILBOULDER AS NOTEDNOTES:BOULDERS SHALL HAVE THEFOLLOWING CHARACTERISTICS:1.COLOR: GREY OR TAN2.TYPE: SANDSTONE ORAPPROVED EQUAL3.SOURCE: LOCAL4.FORM: ROUNDED EDGES5.SIZE: SEE PLAN LEGEND6.PLACEMENT: AS SHOWN ONPLAN OR FIELD LOCATE WITHLANDSCAPE ARCHITECTBURY 1/3 OFBOULDER BELOWFINISH GRADEENSURE POSITIVEDRAINAGETREE ROOT ZONEINSTALL 10' BEYONDCANOPY DRIP LINEUNLESS OTHERWISENOTED ON PLANNOTES:1.THE TYPICAL TREE PROTECTION ZONE (TPZ) SHALL ENCOMPASS THE CANOPY PLUS ANADDITIONAL RADIAL WIDTH OF TEN FEET (10’) UNLESS OTHERWISE NOTED ON PLAN.2.MULCH THE ENTIRE AREA OF THE TPZ IN AN EFFORT TO IMPROVE THE GROWINGENVIRONMENT FOR THE ROOTS. DURING CONSTRUCTION PHASE MAINTAIN A FOUR TO SIXINCH LAYER OF CHIP MULCH OVER THE SOIL SURFACE TO REDUCE SOIL COMPACTION,IMPROVE AERATION, ENHANCE MOISTURE RETENTION AND REDUCE TEMPERATUREEXTREMES. MULCH SHALL CONSIST OF SHREDDED BARK, OR WOOD CHIPS.3.FENCE THE TREE PROTECTION ZONE (TPZ) WITH CONSTRUCTION FENCING TO PREVENTWOUNDS TO THE TREE AND SOIL, AND COMPACTION WITHIN THE ROOT ZONE. POST THEFENCE WITH A SIGN STATING: “TREE PROTECTION ZONE – KEEP OUT”.4.SHOULD IT BE NECESSARY TO TRENCH WITHIN THE TPZ ALL TRENCHES SHALL BE HANDDUG. NO ROOTS LARGER THAN TWO INCHES (2”) SHALL BE CUT UNLESS NO OTHERALTERNATIVE IS FEASIBLE. ALL SMALLER ROOTS THAT REQUIRE CUTTING SHALL BE CUTWITH PRUNING SAWS. CUTS SHALL BE MADE FLUSH WITH THE SIDE OF THE TRENCH. IF ATANY TIME TWENTY-FIVE PERCENT (25%) OF THE AREA WITHIN THE TPZ IS BEINGSEPARATED FROM THE TREE BY A TRENCH, THEN THE LINE SHALL BE EITHER RELOCATEDOR INSTALLED BY BORING.5.REMOVAL OF HARDSCAPE AND/OR EXCAVATION WITHIN THE TPZ SHALL BE DONEMANUALLY.6.THE MINIMUM DISTANCE BETWEEN AN OPEN TRENCH AND ANY TREE SHALL BE BETWEENSIX INCHES (6”) TO ONE FOOT (1’) FOR EVERY INCH OF TRUNK DIAMETER MEASURED ATFOUR AND A HALF FEET (4 ½’) ABOVE EXISTING GRADE, DEPENDING ON THE SPECIES OFTREE. MINIMUM CLEARANCE SHALL BE TEN FEET (10’) FROM THE TRUNK OF THE TREE.7.AT NO TIME SHALL ANY EQUIPMENT, MATERIALS, SUPPLIES OR FILL SOIL BE ALLOWED INTHE TREE PROTECTION ZONE UNLESS NECESSARY.8.DO NOT REMOVE TREE PROTECTION-ZONE FENCING, EVEN TEMPORARILY, TO ALLOWDELIVERIES OR EQUIPMENT ACCESS THROUGH THE PROTECTION ZONE.9.TEMPORARY ACCESS IS ONLY PERMITTED SUBJECT TO PREAPPROVAL IN WRITING BYARBORIST IF A ROOT BUFFER EFFECTIVE AGAINST SOIL COMPACTION IS CONSTRUCTEDAS DIRECTED BY ARBORIST. MAINTAIN ROOT BUFFER SO LONG AS ACCESS IS PERMITTEDTREEPROTECTIONSIGNAGECONSTRUCTIONFENCINGEXISTING TREETREE PROTECTION FENCE SCALE: 1/2"=1'-0"9L502©| ALL RIGHTS RESERVED®DRAWN BY |REVISIONSREVIEWED BY |DESIGNED BY |PROJ# |URSUS_MAJOR BOZEMAN, MT LATTICE MATERIALS2026SITE PLAN03.06.2026URSUS_MAJSTA T E OF MONTANALANDSCAPE ARCHI T ECT DEBRALICENSED264ANN-LESLIEROSA05.15.2026 CITY COMMENTS # 105.15.26 9:40 AM | L:\URSUS_MAJ\BIMCAD\LandArch\URSUS_MAJ_L501-L502.dwgL502PLANTINGDETAILSROSADAWSONROSA