Loading...
HomeMy WebLinkAbout019 IrrigationGallatin Center Subdivision Preliminary Plat Application 19 - Irrigation There is no proposed irrigation with the subdivision; therefore, no irrigation supply is identified with this application. Once development of the lots is proposed with subsequent applications, an irrigation source will be identified. Most of the subdivision falls within a solvent site-controlled groundwater area, where irrigation wells may not be permitted. Due to this constraint, it is anticipated that domestic city water will be used for irrigation within the subdivision. The DNRC has been contacted to verify the feasibility of irrigation wells on the subdivision property for future development. If deemed appropriate, further discussions will be held with the MDEQ to determine final feasibility. Please see the DNRC Correspondence included in this section which contains an attachment of the solvent site boundary overlain with the property boundary. Representatives of Tasman Geosciences and the MDEQ have been contacted to identify any additional considerations due to the solvent site. This correspondence is also included in this section. 19 – Irrigation DNRC Correspondence 1 Joselyn Hartwig From:Joselyn Hartwig Sent:Monday, April 14, 2025 3:32 PM To:kstrasheim@mt.gov Subject:Gallatin Center Subdivision - Irrigation Supply Source Attachments:Bozeman Solvent Map.pdf; Lot Layout Exhibit.pdf Hi Kerri, WWC Engineering is preparing a preliminary plat submittal for the Gallatin Center Subdivision located just north of Baxter Lane, west of North 19th Avenue, south of Cattail Street and east of Thomas Drive. The current geocode for the property is: 06-0904-35-1-05-01-0000. We are reaching out to determine the feasibility of landscape irrigation wells for future landscaping within the subdivision. There are no landscaping plans at this time, but we are wanting to confirm if irrigation wells can be permitted on the property for future developments of the lots. The site falls within the Bozeman Solvent Site Controlled Groundwater Area shown in the attached map. The property is outlined in blue on the attached map for reference. The proposed lot layout is also attached. Please let us know if irrigation wells would be a feasible option for the subdivision, or if another water supply source should be pursued. Thank you, JOSELYN HARTWIG | Associate Engineer 895 Technology Blvd, Ste 203 | Bozeman, MT 59718 O: 406.586.0262 | D: 406.898.3448 www.wwcengineering.com 19 – Irrigation Tasman Geosciences Correspondence 1 Joselyn Hartwig From:Joselyn Hartwig Sent:Friday, April 11, 2025 8:08 AM To:jsullivan@tasman-geo.com Subject:Gallatin Center Subdivision - Bozeman Solvent Site Hi Jim, WWC Engineering is preparing a preliminary plat application for a subsequent minor subdivision located in Bozeman, MT. Erik Ringsak from our office gave me your contact information to discuss a pre-application comment we received from the City of Bozeman Engineering Department. The comment is below: The subdivision is located just west of North 19th Avenue and just north of Baxter Lane. The geocode for the property is: 06-0904-35-1-05-01-0000. The location of the property is shown below. 2 Please let me know if there are any construction requirements or other information regarding the solvent site we should be aware of. Thank you, JOSELYN HARTWIG | Associate Engineer 895 Technology Blvd, Ste 203 | Bozeman, MT 59718 O: 406.586.0262 | D: 406.898.3448 www.wwcengineering.com 19 – Irrigation DEQ Correspondence 1 Joselyn Hartwig From:Joselyn Hartwig Sent:Friday, April 11, 2025 7:52 AM To:Fry, Kate Subject:RE: Gallatin Center Subdivision - Bozeman Solvent Site Kate, Thanks for the information. I will pass this onto the contractor in case a Construction Dewatering Permit is required. Thank you, JOSELYN HARTWIG | Associate Engineer 895 Technology Blvd, Ste 203 | Bozeman, MT 59718 O: 406.586.0262 | D: 406.898.3448 www.wwcengineering.com From: Fry, Kate <kfry@mt.gov> Sent: Tuesday, March 11, 2025 8:29 AM To: Joselyn Hartwig <jhartwig@wwcengineering.com> Subject: RE: Gallatin Center Subdivision - Bozeman Solvent Site WARNING: This email originated from an external sender. Please use caution when clicking links or opening attachments. Hi Joselyn, Thank you for reaching out about the Bozeman Solvent Site. The project area shown in your email is within the Bozeman Solvent Site. In August 2011, the Montana Department of Environmental Quality issued the Record of Decision (ROD) for the Bozeman Solvent Site. Tetrachloroethene (PCE) is the main contaminant of concern for the Bozeman Solvent Site. The ROD identified that the Bozeman Solvent Site site-specific clean up level (SSCL) for PCE in groundwater is 5 µg/L. There are no Bozeman Solvent Site groundwater monitoring wells on the west side of North 19th Ave North. Historically, a private well north of the project property (R-07) and a private well south of the project property (R-49) were sampled as part of the Bozeman Solvent Site. R-07 was sampled 6 times between 2000 and 2003. PCE was detected at 1 µg/L in June 2001 and 0.8 µg/L in December 2001. These concentrations are less than the SSCL. PCE was not detected (<0.5 µg/L) during the other sampling events. R-49 was sampled annually from 2000 and 2014, and PCE was not detected (<0.5 µg/L) during any of the sampling events. Groundwater flow across the Bozeman Solvent Site is from the south to the north. Based on historical groundwater data, PCE is not expected to be detected in groundwater at your project area. The ROD does not identify construction requirements related to the Bozeman Solvent Site in the area of your project. However, if construction activities require a dewatering permit, the Construction Dewatering General Permit (CDGP) application requires the applicant to contact me regarding current 2 groundwater plume conditions. This email may satisfy that requirement. Please note, the CDGP may have different requirements for PCE concentrations than the Bozeman Solvent Site SSCL prior to discharge under a CDGP. For additional information on the CDGP application process please contact Christine Weaver in DEQ Water Quality (406-444-3927 or CWeaver@mt.gov). This email only addresses concerns related to the Bozeman Solvent Site. Please let me know if you have questions. Regards, Kate Kate Fry | Senior Project Officer Superfund, AML, and Construction Bureau Waste Management and Remediation Division Montana Department of Environmental Quality Office: 406-444-6426 From: Joselyn Hartwig <jhartwig@wwcengineering.com> Sent: Tuesday, March 11, 2025 8:07 AM To: Fry, Kate <kfry@mt.gov> Subject: [EXTERNAL] Gallatin Center Subdivision - Bozeman Solvent Site Hi Kate, This is Joselyn with WWC Engineering. Erik Ringsak from our office gave me your contact information to discuss a pre-application comment we received from the City of Bozeman Engineering Department. The comment is below: WWC Engineering is preparing a preliminary plat application for a 5-lot subsequent minor subdivision located in Bozeman, MT. The subject property is located just west of North 19th Avenue and just north of Baxter Lane. The geocode for the property is: 06-0904-35-1-05-01-0000 3 Please let me know of any construction requirements or other information regarding the solvent site we should be aware of. Thank you, JOSELYN HARTWIG | Associate Engineer 895 Technology Blvd, Ste 203 | Bozeman, MT 59718 O: 406.586.0262 | D: 406.898.3448 www.wwcengineering.com [wwcengineering.com]