Loading...
HomeMy WebLinkAbout060 - A1-72 - THIRD, FOURTH FLOOR & ROOF PLANS - BUILDING 8R2 R2 6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"ZONE 6 ZONE 7 ZONE 8 ZONE 9 TYP R3 TYP R1 TYP TYP R4 TYP R2 TYP R3 TYP R1 TYP R4 TYP DS DS DS DS DS DS DS DS DSTYP2' - 6".TYP1' - 4"TYP 1' - 4"TYP2' - 6"TYP1' - 4"8" / 1'-0" 8" / 1'-0" 8" / 1'-0" 8" / 1'-0"8" / 1'-0" 8" / 1'-0" 8" / 1'-0"8" / 1'-0" 8" / 1'-0" 8" / 1'-0"8" / 1'-0"8" / 1'-0" 8" / 1'-0" 8" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"A4.7B 1 A4.7A 1 A4.7A2 UNIT 1BR-4 U8307 UNIT 2BR-3 U8305 UNIT 3BR-3 VAR. 1 U8303UNIT 1BR-1 U8301 UNIT 2BR-3 U8308 UNIT 2BR-3 U8306 UNIT 3BR-3 U8304 UNIT 2BR-1 U8302 STAIR A G301 CORRIDOR G302 STAIR B G303 STORAGE G304 3 A5.1 2 A5.1 1 A6.1 2 A6.1 3 A6.1 5' - 0 5/8"20' - 9 1/4"21' - 7 1/4"5' - 0 5/8"7' - 11 7/8"18' - 7 3/8"17' - 10 5/8"7' - 11 7/8"23' - 4 3/8"2' - 10 1/8"2' - 11"23' - 4 1/4"22' - 8"6' - 2 3/4"22' - 8"39' - 0 1/8"50' - 2"39' - 8"39' - 11 1/8" 49' - 3 1/8"39' - 8"29' - 11 5/8" 29' - 9 7/8"9' - 3 1/8"27' - 3 1/2"35' - 9 5/8"27' - 3 7/8"12' - 2 3/4"27' - 5 1/8" 27' - 2 1/4"12' - 0 1/4"2' - 0 1/4"48' - 5 5/8"1' - 4 3/8"38' - 3 3/4"1' - 4 1/4"38' - 5 1/4" 29' - 9 7/8"9' - 3 1/8"27' - 3 1/2"35' - 9 5/8"27' - 3 7/8"12' - 2 3/4"27' - 5 1/8" W03 W03 W03 A9.1 2 SIM A9.2 2 SIM5' - 3 3/4"12 G304 G303 G30126' - 6" 4 A6.1 25' - 10 5/8"16' - 7 5/8"22' - 0 3/4"38' - 10"27' - 5 1/8"12' - 5 3/4"25' - 10" 25' - 10 5/8"16' - 7 5/8"22' - 0 3/4"38' - 10"27' - 5 1/8"12' - 5 3/4"25' - 10" 3 A6.2 4 A6.2 H1 H1 H1H1 D1 C1 C1 C1 C1 C1 D1 D1 D1 D1 D1 D1 D1 F G I H J 181617151413111012 A4.7B 252' - 5 3/4"169' - 2" W03 W03 BUILDING 1 (CLUBHOUSE - CH)BUILDING 10BUILDING 8BUILDING 9BUILDING 7 BUILDING 6 BUILDING 5 BUILDING 4 BUILDING 3BUILDING 2 SENIOR 1. PRIVATE CONCRETE PATIO AT UNIT, TYPICAL UNLESS OTHERWISE NOTED -SEE SITE PLAN 2. ENGAGED PILASTER WRAPPED IN CEMENTITIOUS TRIM 3. CONCRETE PAD AT EXITS -SEE CIVIL FOR SIDEWALK LEADING TO PADS 4. FURRED WALL FOR EXTERIOR DECORATIVE DETAIL -SEE ELEVATIONS 5. ROOF BELOW, SEE ROOF PLAN 6. COVERED PORCH 7. LINE OF SOFFIT, BEAM AND/ OR ROOF ABOVE 8. WOOD PATIO -TREX DECKING OVER PRESSURE TREATED FRAMING 9. UNIT TO BE 3BR-2 TYPE A AT BUILDING 3, UNIT TO BE 3BR-3 TYPE B AT BUILDING 5 10. UNIT TO BE 2BR-2 TYPE A AT BUILDINGS 2 AND 6 11. UNIT TO BE 3BR-3 A/V AT BUILDINGS 3 AND 5 12. ATTIC ACCESS PANEL -SEE DETAIL 1/A6.3 13. ACCESSIBLE PUSH BUTTON OPERATOR -SEE ELECTRICAL 14. ACCESS CONTROL MODULE -SEE ELECTRICAL 15. UNIT TO BE 2BR-3 A/V AT BUILDING 2, UNIT TO BE 2BR-3 AT BUILDING 6 16. UNIT TO BE 1BR-4 AT BUILDING 2, UNIT TO BE 1BR-4 A/V AT BUILDING 6 17. FDC LOCATION. LOCATION VARIES BETWEEN BUILDINGS 2, 3, AND 5 AND 6. SEE CIVIL AND PLUMBING 18. FDC LOCATION, SEE CIVIL AND PLUMBING FLOOR PLAN KEYNOTES# R1.ASPHALT ROOFING R2.GUTTER R3.RIDGE VENT R4.DRAFTSTOPPING DOOR -SEE DETAIL 3/A6.3 ROOF PLAN KEYNOTES# ROOF PLAN LEGEND SLOPE IN STRUCTURE LINE OF WALL BELOW LINE OF DRAFTSTOPPING -SEE DETAIL 2/A6.3 DOWNSPOUT LOCATION -COORDINATE WITH CIVIL & EXTERIOR ELEVATIONSDS ROOF VENTILATION CALCULATIONS BLDGS 3 & 5: ZONE 9: 2,374 SF VENTILATION REQUIRED: 2,374 SF / 300 = 7.91 SF OR 1,139.04 SI REQUIRED VENTILATION AT RIDGE: 569.52 SI PROVIDED VENTILATION AT RIDGE: 31' -9" RIDGE VENT (18 SI / LF) = 571.5 SI 571.5 SI REQUIRED VENTILATION AT EAVE: 569.52 SI PROVIDED VENTILATION AT EAVE: 39.9 SF OF SOFFIT VENTING (14.34 SI / SF) = 572.1 SI ZONE 8: 2,257 SF VENTILATION REQUIRED: 2,257 SF / 300 = 7.52 SF OR 1,082.88 SI REQUIRED VENTILATION AT RIDGE: 541.44 SI PROVIDED VENTILATION AT RIDGE: 30' -1" RIDGE VENT (18 SI / LF) = 541.49 SI 541.49 SI REQUIRED VENTILATION AT EAVE: 541.44 SI PROVIDED VENTILATION AT EAVE: 37.8 SF OF SOFFIT VENTING (14.34 SI / SF) = 542.1 SI ZONE 7: 2,877 SF VENTILATION REQUIRED: 2,877 SF / 300 = 9.59 SF OR 1,380.96 SI REQUIRED VENTILATION AT RIDGE: 690.48 SI PROVIDED VENTILATION AT RIDGE: 38' -5" RIDGE VENT (18 SI / LF) = 691.5 SI 691.5 SI REQUIRED VENTILATION AT EAVE: 690.48 SI PROVIDED VENTILATION AT EAVE: 48.3 SF OF SOFFIT VENTING (14.34 SI / SF) = 692.6 SI ZONE 6: 2,445 SF VENTILATION REQUIRED: 2,445 SF / 300 = 8.15 SF OR 1,173.6 SI REQUIRED VENTILATION AT RIDGE: 586.8 SI PROVIDED VENTILATION AT RIDGE: 32' -6" RIDGE VENT (18 SI / LF) = 586.8 SI 586.8 SI REQUIRED VENTILATION AT EAVE: 586.8 SI PROVIDED VENTILATION AT EAVE: 41 SF OF SOFFIT VENTING (14.34 SI / SF) = 587.9 SI ROOF VENTILATION CALCULATION NOTES: 1. ROOF VENTILATION CALCULATIONS PROVIDED BASED ON PLAN AREA. 2. TRIPLE 4" BASKET WEAVE FULL SOFFIT PROVIDES 14.34 SQ. IN. NET FREE AREA PER SQ. FT. 3. RIDGE VENT PROVIDES 18 SQ. IN. NET FREE ARE PER LIN. FT. 4. DURA-FLOW 'TOP' CAP VENT #6075xx (MATCH ROOF COLOR) ROOF LOUVER PROVIDES 75 SQ. IN. NET FREE AREA PER UNIT. 5. ALTERNATE CAP: LOMANCO MODEL 135 (MATCH ROOF COLOR) ROOF LOVER PROVIDES 144 SQ. IN. NET FREE AREA PER UNIT. ISSUANCE PROJECT NUMBER Copyright © 2024 HDJ Inc. All Rights Reserved Autodesk Docs://DevCo Graf Street - Canter Bozeman MT 2023.0085/2023.0085 - Arch.rvt3/20/2024 9:07:07 AM2023.0085ALDER RIDGE & SAGE PEAKAPARTMENTSGRAF ST. APARTMENTS, LLCA1.72 THIRD, FOURTH FLOOR & ROOF PLANS - BUILDING 8 GRAF STREET, BOZEMAN. MT 597151/8" = 1'-0"A1.72 ROOF PLAN - BUILDING 8 2 1/8" = 1'-0"A1.72 THIRD & FOURTH FLOOR PLAN - BUILDING 8 1 NOT TO SCALE KEYPLAN NO. DATE DESCRIPTION 1 2024.03.19 SITE PLAN SUBMISSION