Loading...
HomeMy WebLinkAbout054 - A1-42 - THIRD, FOURTH FLOOR & ROOF PLANS - BUILDINGS 4 & 98" / 1'-0" 8" / 1'-0"6" / 1'-0"6" / 1'-0"8" / 1'-0" 8" / 1'-0" 8" / 1'-0"6" / 1'-0"8" / 1'-0"8" / 1'-0" 8" / 1'-0"8" / 1'-0" 8" / 1'-0" R2 TYP R1 TYP R4 TYP R3 TYP R2 TYP R1 TYP R4 TYP R3 TYP R2 TYP R2 TYP ZONE 14 ZONE 15 ZONE 16 ZONE 17 1 A6.2 DS DS DS DS DS DS DS DSTYP2' - 6".TYP1' - 4"TYP 1' - 4"TYP1' - 4".TYP2' - 6".4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"A4.4 1 A4.4 4 UNIT 1BR-4 U4307 UNIT 1BR-3 VAR. 1 U4305 UNIT 1BR-3 VAR. 2 U4303 UNIT 1BR-1 U4301 UNIT 2BR-3 U4308 UNIT 1BR-3 VAR. 1 U4306UNIT 1BR-3 U4304 UNIT 2BR-1 U4302 7' - 11 1/4"17' - 10 5/8"18' - 7 3/8"7' - 11 1/4"STAIR A D301 CORRIDOR D302 STAIR B D303 STORAGE D304 1 A5.2 4 A6.1 23' - 4 1/4"2' - 9 5/8"2' - 10 3/8"23' - 4 1/4"5' - 0"20' - 9"21' - 7 1/2"5' - 0"A4.4239' - 1 1/4"29' - 11"30' - 1 3/8"39' - 0 7/8"22' - 7 3/8"6' - 2 1/8"22' - 8"28' - 11 5/8"30' - 0"38' - 3 1/4" A4.4 3 29' - 10 1/8"9' - 3 1/8"28' - 8 1/4"43' - 10 1/4"27' - 5 3/4" 27' - 1 3/4"12' - 1"1' - 11 1/2"27' - 11 1/2"1' - 7"28' - 6 1/2"1' - 5 1/2"29' - 10 1/2"8' - 6 1/4" 139' - 1 1/2" 25' - 11 3/8"16' - 6"25' - 3 1/8"42' - 7 1/2"28' - 9 1/2" 25' - 11 3/8"16' - 6"25' - 3 1/8"42' - 7 1/2"28' - 9 1/2" A9.1 2 SIM A9.2 2SIM W03 W03 W03 12 5' - 3 1/8"D304 D301D303 3 A6.1 2 A5.1 1 A6.1 2 A6.1 26' - 5 1/2" 1 A6.2 3 A6.2 4 A6.2D1 D1 D1 C1 C1 C1 D1 D1 D1 H1H1 H1 D1 D1 29 31 33 35 38 U S Q 34 36 373230 T R 52' - 4 1/2"29' - 10 1/8"9' - 3 1/8"28' - 8 1/4"43' - 10 1/4"27' - 5 3/4" W03 W03 1. PRIVATE CONCRETE PATIO AT UNIT, TYPICAL UNLESS OTHERWISE NOTED -SEE SITE PLAN 2. ENGAGED PILASTER WRAPPED IN CEMENTITIOUS TRIM 3. CONCRETE PAD AT EXITS -SEE CIVIL FOR SIDEWALK LEADING TO PADS 4. FURRED WALL FOR EXTERIOR DECORATIVE DETAIL -SEE ELEVATIONS 5. ROOF BELOW, SEE ROOF PLAN 6. COVERED PORCH 7. LINE OF SOFFIT, BEAM AND/ OR ROOF ABOVE 8. WOOD PATIO -TREX DECKING OVER PRESSURE TREATED FRAMING 9. UNIT TO BE 3BR-2 TYPE A AT BUILDING 3, UNIT TO BE 3BR-3 TYPE B AT BUILDING 5 10. UNIT TO BE 2BR-2 TYPE A AT BUILDINGS 2 AND 6 11. UNIT TO BE 3BR-3 A/V AT BUILDINGS 3 AND 5 12. ATTIC ACCESS PANEL -SEE DETAIL 1/A6.3 13. ACCESSIBLE PUSH BUTTON OPERATOR -SEE ELECTRICAL 14. ACCESS CONTROL MODULE -SEE ELECTRICAL 15. UNIT TO BE 2BR-3 A/V AT BUILDING 2, UNIT TO BE 2BR-3 AT BUILDING 6 16. UNIT TO BE 1BR-4 AT BUILDING 2, UNIT TO BE 1BR-4 A/V AT BUILDING 6 17. FDC LOCATION. LOCATION VARIES BETWEEN BUILDINGS 2, 3, AND 5 AND 6. SEE CIVIL AND PLUMBING 18. FDC LOCATION, SEE CIVIL AND PLUMBING FLOOR PLAN KEYNOTES# R1.ASPHALT ROOFING R2.GUTTER R3.RIDGE VENT R4.DRAFTSTOPPING DOOR -SEE DETAIL 3/A6.3 ROOF PLAN KEYNOTES# ROOF PLAN LEGEND SLOPE IN STRUCTURE LINE OF WALL BELOW LINE OF DRAFTSTOPPING -SEE DETAIL 2/A6.3 DOWNSPOUT LOCATION -COORDINATE WITH CIVIL & EXTERIOR ELEVATIONSDS ROOF VENTILATION CALCULATIONS BLDG 7: ZONE 17: 2,279 SF VENTILATION REQUIRED: 2,279 SF / 300 = 7.6 SF OR 1,094.4 SI REQUIRED VENTILATION AT RIDGE: 547.2 SI PROVIDED VENTILATION AT RIDGE: 30' -5" RIDGE VENT (18 SI / LF) = 547.5 SI 547.5 SI REQUIRED VENTILATION AT EAVE: 547.2 SI PROVIDED VENTILATION AT EAVE: 38.2 SF OF SOFFIT VENTING (14.34 SI / SF) = 547.8 SI ZONE 16: 1,679 SF VENTILATION REQUIRED: 1,679 SF / 300 = 5.6 SF OR 806.4 SI REQUIRED VENTILATION AT RIDGE: 403.2 SI PROVIDED VENTILATION AT RIDGE: 22' -5" RIDGE VENT (18 SI / LF) = 403.5 SI 403.5 SI REQUIRED VENTILATION AT EAVE: 403.2 SI PROVIDED VENTILATION AT EAVE: 28.2 SF OF SOFFIT VENTING (14.34 SI / SF) = 404.4 SI ZONE 15: 1,870 SF VENTILATION REQUIRED: 1,870 SF / 300 = 6.23 SF OR 897.12 SI REQUIRED VENTILATION AT RIDGE: 448.56 SI PROVIDED VENTILATION AT RIDGE: 25' -0" RIDGE VENT (18 SI / LF) = 450 SI 450 SI REQUIRED VENTILATION AT EAVE: 448.56 SI PROVIDED VENTILATION AT EAVE: 31.4 SF OF SOFFIT VENTING (14.34 SI / SF) = 450.3 SI ZONE 14: 2,348 SF VENTILATION REQUIRED: 2,348 SF / 300 = 7.83 SF OR 1,127.52 SI REQUIRED VENTILATION AT RIDGE: 563.76 SI PROVIDED VENTILATION AT RIDGE: 31' -4" RIDGE VENT (18 SI / LF) = 563.99 SI 563.99 SI REQUIRED VENTILATION AT EAVE: 563.76 SI PROVIDED VENTILATION AT EAVE: 39.4 SF OF SOFFIT VENTING (14.34 SI / SF) = 565.99 SI ROOF VENTILATION CALCULATION NOTES: 1. ROOF VENTILATION CALCULATIONS PROVIDED BASED ON PLAN AREA. 2. TRIPLE 4" BASKET WEAVE FULL SOFFIT PROVIDES 14.34 SQ. IN. NET FREE AREA PER SQ. FT. 3. RIDGE VENT PROVIDES 18 SQ. IN. NET FREE ARE PER LIN. FT. 4. DURA-FLOW 'TOP' CAP VENT #6075xx (MATCH ROOF COLOR) ROOF LOUVER PROVIDES 75 SQ. IN. NET FREE AREA PER UNIT. 5. ALTERNATE CAP: LOMANCO MODEL 135 (MATCH ROOF COLOR) ROOF LOVER PROVIDES 144 SQ. IN. NET FREE AREA PER UNIT. BUILDING 1 (CLUBHOUSE - CH)BUILDING 10BUILDING 8BUILDING 9BUILDING 7 BUILDING 6 BUILDING 5 BUILDING 4 BUILDING 3BUILDING 2 SENIOR ISSUANCE PROJECT NUMBER Copyright © 2024 HDJ Inc. All Rights Reserved Autodesk Docs://DevCo Graf Street - Canter Bozeman MT 2023.0085/2023.0085 - Arch.rvt3/20/2024 9:05:59 AM2023.0085ALDER RIDGE & SAGE PEAKAPARTMENTSGRAF ST. APARTMENTS, LLCA1.42 THIRD, FOURTH FLOOR & ROOF PLANS - BUILDINGS 4 & 9GRAF STREET, BOZEMAN. MT 597151/8" = 1'-0"A1.42 ROOF PLAN - BUILDINGS 4 & 9 2 1/8" = 1'-0"A1.42 THIRD & FOURTH FLOOR PLAN - BUILDINGS 4 & 9 1 NOT TO SCALE KEYPLAN NO. DATE DESCRIPTION 1 2024.03.19 SITE PLAN SUBMISSION SHOWN: BUILDING 4 SAME: BUILDING 9 SHOWN: BUILDING 4 SAME: BUILDING 9 NORTH VARIES NORTH VARIES