Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
052 - A1.32 - THIRD, FOURTH FLOOR & ROOF PLANS -BUILDINGS 3 & 7
DWDW DW DWDW DW DW DW UPDN UPDNUNIT 1BR-4U3307UNIT 2BR-3U3305 UNIT 3BR-3VAR. 1U3303 STAIR C C301 UNIT 1BR-1U3301 UNIT 2BR-1 U3302 UNIT 3BR-5 U3304 UNIT 2BR-3 U3306 UNIT 2BR-3 U3308 CORRIDOR C302 STORAGE C304 STAIR DC303 23' - 4 3/8"2' - 10 1/8"2' - 11"23' - 4 1/4"A4.3B 1 A4.3A 1 A4.3A2 A4.3B2 3 A5.1 2 A5.1 65' - 8 7/8"38' - 10"23' - 6 3/8"13' - 8 3/8"27' - 4 3/8" 7' - 7"9' - 10"13' - 10 3/4"13' - 8"12' - 11 1/8"7' - 10"5' - 7"13' - 6"12' - 8"7' - 1"5' - 11"11' - 7 3/8"6' - 0"6' - 10"6' - 10 3/8"7' - 3"13' - 7 3/8"6' - 6"8' - 0"18' - 6 1/2"17' - 11 1/4"8' - 0"W03 W03 W03 5' - 0"21' - 7 7/8"20' - 9 7/8"5' - 0"A9.22 A9.1 2 6' - 6"13' - 3 1/4"7' - 8"6' - 1 3/4"6' - 1"6' - 8"13' - 0"7' - 8"6' - 0"12' - 4 1/2"11' - 10"5' - 7"7' - 8"12' - 7 1/2"6' - 11"4' - 8 1/2"4' - 7 5/8"10' - 7 7/8"12' - 0"7' - 2" 38' - 5 1/4"1' - 4 1/4"38' - 3 3/4"1' - 4 3/8"48' - 5 5/8"2' - 0 3/8"12' - 0 1/4"27' - 2 1/4" 27' - 5 1/4"12' - 2 3/4"27' - 4"35' - 9 1/2"27' - 2 1/2"9' - 4 1/8"29' - 9 7/8" 1 A6.1 2 A6.1 4 A6.1 37' - 7 3/4"39' - 8"49' - 11 1/8" 39' - 0"39' - 8"50' - 5"39' - 2"21' - 8"6' - 2 3/4"21' - 8"5' - 3 3/4"12 C304 C303 C3013 A6.1 26' - 6" 3 A6.2 4 A6.2 W03 W03 D1 D1D1 D1 D2 D1 C1 C1 C1 C1 D1 D1 H1 1 A 3245 6 8 97 B D C E 169' - 2"52' - 5 3/4"1 8888 8888W02W02W02W02W02W02W02 W02 W02W02W02W02W02W02W02W02W02 2 A6.2 1' - 0"3' - 0"37 37 W02 12 4" / 1'-0"4" / 1'-0"R2 TYP ZONE 3-1ZONE 3-2ZONE 3-3 ZONE 3-4 R1 TYP R3 TYP R4 TYP R2TYP R1TYP R3TYP R4TYP R2 TYP R2 TYP DS DS DSDS DS DS DS DSDS 1 A 3245 6 8 9 7 B D C E 2' - 6"1' - 4"1' - 4"1' - 4"2' - 6"6" / 1'-0" 6" / 1'-0"6" / 1'-0"6" / 1'-0" 6" / 1'-0"6" / 1'-0"6" / 1'-0" 6" / 1'-0"6" / 1'-0" 6" / 1'-0" 6" / 1'-0" 6" / 1'-0" 6" / 1'-0"6" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"R5 TYP R5 TYP DSDS DS DS DSDS DS DS4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"2' - 6"1' - 4"2' - 6"2' - 6"1' - 4"2' - 6"3' - 4"2' - 6"2' - 6"TYP6"4" TYP R6 R6 1.A. B. 2.3. 4. 5.6.7.8. 9.10.11.12.13.14.15. 16. 17. 18.19. 20. 21. 22.23.24.25.26.27.28.29.30.31. 32.33.34.35.36. 37.38.39.40.41.42. A. B. 43. A. B. PRIVATE CONCRETE PATIO AT UNITS (TYPICAL) - SEE SITE PLANTYPICAL SIZES AT BLDGS 3, 4, 5, 6, 7, 8, 9 ILLUSTRATED IN FLOOR PLANSUNIT SIZE AT BUILDING #10 ON WEST SIDE OF BUILDING NOTED WITH DASH LINES. THE SIZE OF THESE PATIOS ARE 3'-9" DEEP AND 10'-8" WIDE. THERE ARE 3 TOTAL PATIOSCOLUMN - SEE STRUCTURALCONCRETE PAD AT EXITS - SEE CIVIL FOR SIDEWALK LEADING TO PADSFURRED WALL FOR EXTERIOR DECORATIVE DETAIL - SEE ELEVATIONSROOF BELOW, SEE ROOF PLANCOVERED PORCHLINE OF SOFFIT, BEAM AND/ OR ROOF ABOVEBALCONY - LIGHT WEIGHT CONCRETE OVER PRESSURE TREATED FRAMING (BALCONY SIZE CORRESPONDS WITH THE THE PATIO SIZE NOTED ON FIRST FLOOR)UNIT TO BE 3BR-2 TYPE A AT BUILDINGS 3, 7 & 8UNIT TO BE 2BR-2 TYPE A AT BUILDING 3, 7 & 8UNIT TO BE 4BR-2 TYPE A AT BUILDINGS 5 & 10ATTIC ACCESS PANEL AT FOURTH FLOOR - SEE DETAIL 1/A6.4ACCESSIBLE PUSH BUTTON OPERATOR - SEE ELECTRICALACCESS CONTROL MODULE - SEE ELECTRICALUNIT TO BE 2BR-3 A/V AT BUILDING 3, UNIT TO BE 2BR-3 AT BUILDING 7UNIT TO BE 1BR-1 A/V AT BUILDING 4, UNIT TO BE 1BR-1 AT BUILDING 9FDC LOCATION. LOCATION VARIES BETWEEN BUILDINGS 3, 7, AND 8. SEE CIVIL AND PLUMBINGFDC LOCATION, SEE CIVIL AND PLUMBINGUNIT TO BE 1BR-2 TYPE A AT BUILDINGS 4, 6 & 9 AND 1BR-2 TYPE A VAR 1 AT BUILDING 3 AND 1BR-2 TYPE B AT BUILDING 7UNIT TO BE 4BR-1 A/V AT BUILDING 5, UNIT TO BE 4BR-1 AT BUILDING 10BATHTUBS AND CORRIDOR WALLS SHIFTED AT THIS LOCATION FOR DOOR COORDINATION - ALL FLOORSMAILBOXESCOUNTERTOP WITH BACKSPLASH - SEE INTERIORSBRACKETAMAZON LOCKERSWALL BASE - SEE INTERIORSWASHER WITH PEDESTAL - SEE PLUMBINGDRYER WITH PEDESTAL - SEE MECHANICALACCESS PANEL - SEE MECHANICALSTONE HEARTH - SEE INTERIORSELECTRIC FIREPLACE RECESSED IN WALL- BASIS OF DESIGN: AMANTII SYMMETRY SERIES, MODEL # SYM-60STONE SURROUND (3 SIDES) - SEE INTERIORSSHELVINGLOCATION OF FLUSH HANDLEPIPE PROTECTION ON EXPOSED PIPES - SEE PLUMBINGLIGHT FIXTURE - SEE ELECTRICAL - LIGHT FIXTURE OVER VANITIES SHALL BE CENTERED ABOVE COUNTER AND LOCATED 3" - 4" FROM THE TOP OF MIRROR TO BOTTOM OF FIXTURE - COORDINATE WITH ELECTRICALRADON ACCESS PANEL ON FOURTH FLOOR - SEE PLUMBINGTILE WAINSCOT - SEE INTERIORSCHAIR RAIL - SEE INTERIORSGAS METERS - SEE MECHANICALELECTRICAL METERS - SEE ELECTRICALPROVIDE EXTERIOR SIGNAGE ON ELECTRICAL METERING EQUIPMENT PER ONE LINE DIAGRAM THAT STATES THE FOLLOWING: AT BUILDING #5 "GAS METERS ARE NORTH APPROXIMATELY 150'-0" FROM ELECTRIC METERSAT BUILDING #10 GAS METERS ARE SOUTH APPROXIMATELY 150'-0" FROM ELECTRIC METERSPROVIDE EXTERIOR SIGNAGE ABOVE GAS METERS THAT STATES THE FOLLOWING:AT BUILDING #5 ELECTRIC METERS ARE SOUTH APPROXIMATELY 150'-0" FROM GAS METERSAT BUILDING #10 ELECTRIC METERS ARE NORTH APPROXIMATELY 150'-0" FROM GAS METERS FLOOR PLAN KEYNOTES#BUILDING 10BUILDING 8BUILDING 9BUILDING 7 BUILDING 6BUILDING 5BUILDING 4BUILDING 3 BUILDING 2(CLUBHOUSE - CH) BUILDING 1 -SENIORSEE LOT 2- SAGE PEAK APT DRAWING PACKAGE 1.ALL ROOF-MOUNTED EQUIPMENT AND PENETRATIONS ARE NOT SHOWN. COORDINATE QUANTITIES AND LOCATIONS WITH OTHER DISCIPLINES. GENERAL ROOF PLAN NOTES R1.ASPHALT ROOFINGR2.GUTTERR3.RIDGE VENTR4.DRAFTSTOPPING DOOR - SEE DETAIL 3/A6.4R5. PERMANENT ROOF ANCHOR EQUAL TO "ARS" - INSTALL ALONG ROOF RIDGE MAX 25 FEET ON CENTER AND STARTING 8 FEET FROM ROOF EDGE, INSTALL PER MANUFACTURER REQUIREMENTSR6.ATTIC ACCESS ROOF PLAN KEYNOTES# ROOF PLAN LEGEND SLOPE IN STRUCTURE LINE OF WALL/ COLUMN, BEAM BELOW LINE OF DRAFTSTOPPING TO ALIGN ABOVE THE DEMISING WALL BELOW - SEE STRUCTURAL AND DETAIL 2/A6.3 DOWNSPOUT LOCATION - COORDINATE WITH CIVIL & EXTERIOR ELEVATIONSDS ROOF VENTILATION CALCULATIONS BLDGS 3 & 7: ZONE 3-1: 2,374 SFVENTILATION REQUIRED: 2,374 SF / 300 = 7.91 SF OR 1,139.04 SI REQUIRED VENTILATION AT RIDGE: 569.52 SIPROVIDED VENTILATION AT RIDGE: 31' - 9" RIDGE VENT (18 SI / LF) = 571.5 SI 571.5 SI REQUIRED VENTILATION AT EAVE: 569.52 SIPROVIDED VENTILATION AT EAVE:39.9 SF OF SOFFIT VENTING (14.34 SI / SF) = 572.1 SI ZONE 3-2: 2,257 SFVENTILATION REQUIRED: 2,257 SF / 300 = 7.52 SF OR 1,082.88 SI REQUIRED VENTILATION AT RIDGE: 541.44 SIPROVIDED VENTILATION AT RIDGE:30' - 1" RIDGE VENT (18 SI / LF) = 541.49 SI 541.49 SI REQUIRED VENTILATION AT EAVE: 541.44 SIPROVIDED VENTILATION AT EAVE:37.8 SF OF SOFFIT VENTING (14.34 SI / SF) = 542.1 SI ZONE 3-3: 2,877 SFVENTILATION REQUIRED: 2,877 SF / 300 = 9.59 SF OR 1,380.96 SI REQUIRED VENTILATION AT RIDGE: 690.48 SI PROVIDED VENTILATION AT RIDGE: 38' - 5" RIDGE VENT (18 SI / LF) = 691.5 SI 691.5 SI REQUIRED VENTILATION AT EAVE: 690.48 SIPROVIDED VENTILATION AT EAVE:48.3 SF OF SOFFIT VENTING (14.34 SI / SF) = 692.6 SI ZONE 3-4: 2,445 SFVENTILATION REQUIRED: 2,445 SF / 300 = 8.15 SF OR 1,173.6 SI REQUIRED VENTILATION AT RIDGE: 586.8 SIPROVIDED VENTILATION AT RIDGE:32' - 6" RIDGE VENT (18 SI / LF) = 586.8 SI 586.8 SI REQUIRED VENTILATION AT EAVE: 586.8 SIPROVIDED VENTILATION AT EAVE:41 SF OF SOFFIT VENTING (14.34 SI / SF) = 587.9 SI ROOF VENTILATION CALCULATION NOTES: 1.2. 3.4. 5. ROOF VENTILATION CALCULATIONS PROVIDED BASED ON PLAN AREA.TRIPLE 4" BASKET WEAVE FULL SOFFIT PROVIDES 14.34 SQ. IN. NET FREE AREA PER SQ. FT.RIDGE VENT PROVIDES 18 SQ. IN. NET FREE ARE PER LIN. FT.DURA-FLOW 'TOP' CAP VENT #6075xx (MATCH ROOF COLOR) ROOF LOUVER PROVIDES 75 SQ. IN. NET FREE AREA PER UNIT.ALTERNATE CAP: LOMANCO MODEL 135 (MATCH ROOF COLOR) ROOF LOVER PROVIDES 144 SQ. IN. NET FREE AREA PER UNIT. ISSUANCE PROJECT NUMBER NOT FOR NOT FOR CONSTRUCTI O N C O N S T R U C TI O N Copyright © 2024 HDJ Inc. All Rights Reserved Autodesk Docs://DevCo Graf Street - Canter Bozeman MT 2023.0085/2023.0085 - Arch.rvt2023.0085ALDER RIDGE APARTMENTSGRAF ST. APARTMENTS, LLCA1.32 THIRD, FOURTH FLOOR & ROOF PLANS - BUILDINGS 3 & 7GRAF STREET, BOZEMAN. MT 59715NEW CONSTRUCTION FOR 1/8" = 1'-0"A1.32 THIRD & FOURTH FLOOR PLAN - BUILDINGS 3 & 71 1/8" = 1'-0"A1.32 ROOF PLAN - BUILDINGS 3 & 72 NOT TO SCALE KEYPLAN SHOWN: BUILDING 3SAME: BUILDING 7 NORTH VARIES SHOWN: BUILDING 3SAME: BUILDING 7 NORTH VARIES NO.DATE DESCRIPTION 1 2025.11.12 FINAL INTERNALREVIEW