Loading...
HomeMy WebLinkAbout030 - E0.2 - ELEC -SITE PLANJ J JSNEW BUILDING ED1 ED1 ED1ED1ED1WP1WP2 WP3 WP3 WP2 WP2WP2WP2 WP2 WP3 WP1 WP GFI 1 1 2 3 4 4 WP3 5 5 5 +8'-0" AFG +8'-0" AFG +8'-0" AFG +9'-0" AFG+9'-0" AFG+9'-0" AFG +9'-0" AFG +9'-0" AFG +9'-0" AFG +9'-0" AFG +9'-0" AFG +9'-0" AFG B2 B2 ED4 B2 B2 1 WP3 5 +8'-0" AFG 4 SL1 SL1 SL1 SL2SL2 6 6 6 6 EXISTING PARKING LOT REFER TO CIVIL AND ARCHITECTURAL 7 8 8 8 8 H -20 H -19 H -27 H - 16,18 H - 16,18 H - 16,18 H - 21H - 21 H - 21 H - 21 H - 21 H - 21 H - 22 H - 22 H - 22 H - 22 H - 22 H - 22 H - 22 H - 22 H - 22 H - 22 H - 22H - 22H - 22 H - 22 H2 - 5 H2 - 5 H2 - 5 H - 24,26 H - 24,26 H -38 WP4 WP H - 16,18 +5'-2" AFG WP4 H - 16,18 +5'-2" AFG 9 A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. C. CONTRACTOR IS FULLY RESPONSIBLE FOR FOLLOWING ALL APPLICABLE CODES AND STANDARDS, AS WELL AS ALL LOCAL ADDENDUM TO THOSE CODES AND STANDARDS, WHETHER SPECIFICALLY SHOWN ON THESE DRAWINGS OR NOT. D. RECEPTACLES AND OUTLET BOXES SHALL NOT BE INSTALLED BACK-TO-BACK ON OPPOSITE SIDES OF THE WALL. OUTLET BOXES THAT ARE INSTALLED ADJACENT TO EACH OTHER ON OPPOSITE SIDES OF THE WALLS SHALL HAVE SOUND INSULATING PUTTY PADS INSTALLED ON BACK OF BOTH ELECTRICAL BOXES. GENERAL ELECTRICAL NOTES: SHEET NUMBER PROJECT CODE PROJECT ADDRESS ARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS. DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ON DRAWING SHEET AND MAY NOT BE REPRODUCED OR USED FOR OTHER PURPOSES WITHOUT WRITTEN PERMISSION FROM ARCHITECT. FOR SITE PLAN REVIEW ONLY 2042 Stadium Dr SUITE 2 BOZEMAN, MT 59715 SHEET NAME PROJECT NAME DRAWING REVISIONS DRAWING ISSUE DATE DRAWING ISSUED FOR PHONE: (406) 587-2917 Autodesk Docs://FWC - Ferguson Farm Office Building/FWC - First West Consulting Office Building R24.rvt4/8/2026 3:11:38 PME0.1 FWC FERGUSON FARM OFFICE BUILDING ELEC -SITE PLAN 785 BOARDWALK AVE BOZEMAN, MT 59718 SITE PLAN 2026-04-10 3/32" = 1'-0"E0.1 1 ELEC - SITE PLAN N KEYED NOTES 1 PROVIDE 120V, 20A CIRCUIT, AND JUNCTION BOX FOR FUTURE ELECTRIC BIKE CHARGER. 2 PROVIDE WEATHER-RESISTANT GFI RECEPTACLE IN WEATHERPROOF JBOX WITH COVER. 3 EXTERIOR WALL IS A FIRE RATED ASSEMBLY. REFER TO ARCHITECTURAL PLANS FOR ALL FIRE RATED ASSEMBLY LOCATIONS. PROVIDE FIRE BARRIER PUTTY PADS ON THE BACK OF ALL ELECTRICAL BOXES WITHIN FIRE RATED ASSEMBLIES, FIRE BARRIER SEALANT, AND OTHER TYPES OF FIRE BARRIER PRODUCTS TO MAINTAIN FIRE RATED ASSEMBLY FIRE RATING. REFER TO SPECIFICATIONS FOR MORE INFORMATION. 4 PROVIDE DIMMING FOR EAST WALLPACK LIGHTING TO COMPLY WITH AHJ FOOTCANDLE LIMITS AT PROPERTY LINE. COORDINATE FINAL SETTINGS WITH LOCAL JURISDICTION REQUIREMENTS PRIOR TO FINAL INSPECTION. 5 PROVIDE ADDITIONAL 0-10V WIRING FOR DIMMING OF WALLPACK. REFER TO SHEET E2.0 FOR LOCATION OF DIMMER LOCATED IN MECHANICAL ROOM [104]. 6 PROVIDE LIGHTING FIXTURE ABOVE SIGNAGE. SIGNAGE LIGHT FIXTURE SHALL BE INSTALLED AT TOP OF SIGN AND AIMED DOWNWARD TO SIGN. SIGNAGE LIGHT FIXTURE SHALL COMPLY WITH CITY OF BOZEMAN INSTALLATION REQUIREMENTS. FINAL FIXTURE DESIGN TO BE PROVIDED BY MANUFACTURER APPLICATION ENGINEER BASED ON ANTICIPATED TENANT SIGNAGE. FIXTURE SHOWN AND SCHEDULED AS BASIS OF DESIGN FOR BUDGETING PURPOSES. 7 EXISTING PARKING LOT. REFER TO ARCHITECTURAL AND CIVIL PLANS FOR SITE CONDITIONS AND COORDINATION. 8 REMOTE HEAD TO BE POWERED FROM INDOOR REMOTE-CAPABLE EMERGENCY BUG-EYE (EB1R). REFER TO LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. 9 PROVIDE WEATHERPROOF LIGHT SWITCH FOR TRASH ENCLOSURE LIGHTING. LOCATE IN READILY ACCESSIBLE LOCATION. io.*.{h Si*'.\ i-...1'$t* t i sr*r i t No.' oTffi'l*t* Kiffiifi:.ffi uqt.oi1*' E0.2