HomeMy WebLinkAbout028 - E0.0 - ELECTRICAL COVER SHEETS P S F S T D F FF SS WA CR RE DC ES EL MD GB C H SD SS SC H SD M M M SPD LA PFC M VFD G CB PNL A 208Y/120V3ø, 4W XX XJTV J PS-XXD-1 X ELECTRICAL GENERAL NOTES A. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL SERVICE WORK WITH UTILITY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL SCHEDULING AND COORDINATION OF WORK. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET. C. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT 301-657-3110 OR ON-LINE AT WWW.NECANET.ORG. D. DURING DEMOLITION, THE CONTRACTOR SHALL NOTE ALL EXISTING RACEWAY (BOTH SURFACE AND CONCEALED) TO THE EXTENT POSSIBLE. THESE RACEWAYS SHALL BE REUSED TO THE GREATEST EXTENT POSSIBLE TO ENSURE A CLEAN FINISHED PRODUCT. WHERE PRACTICAL, AND ALLOWED PER CODE, FISHING THROUGH WALLS WITH MC CABLE IS PREFERRED TO SURFACE-MOUNTED CONDUIT. E. CONTRACTOR SHALL REMOVE, TRANSPORT, AND LEGALLY DISPOSE OF LAMPS AND BALLASTS OFF-SITE. IT IS ASSUMED THE BALLASTS DO NOT CONTAIN PCBs. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY IF IT IS SUSPECTED THAT BALLASTS CONTAIN PCBs. F. ALL POWER INTERRUPTIONS SHALL BE COORDINATED WITH OWNER. ANY DISRUPTION OF WORKERS IN THE SPACE SHALL BE KEPT TO A MINIMUM AND BE COORDINATED WITH THE OWNER PRIOR TO WORK COMMENCING IN THAT SPACE. G. CONTRACTOR SHALL EXTEND UNSTITCHED HOT LEG FROM EXISTING EMERGENCY FIXTURE LOCATION TO NEW EMERGENCY FIXTURES. AS NEEDED. SEE DEMO PLANS FOR AN APPROXIMATION OF EXISTING EMERGENCY FIXTURE LOCATIONS. FIELD VERIFY EXACT LOCATION PRIOR TO BID. H. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT. VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS. I. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE-RESISTANCE RATED WALLS. WHERE THIS IS NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE 24" SEPARATION. PROVIDE A UL LISTED THROUGH - PENETRATION FIRESTOP FOR PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES. J. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED, OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED FOR AT LEAST 75 DEGREES C. K. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT VOLTAGE DROP TO 3%. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES SHALL BE AS FOLLOWS: #10 AWG CU FOR RUNS BETWEEN 100 AND 200 LINEAR FEET, #8 AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, AND AS CALCULATED BY THE CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS REQUIRED. L. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT. M. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. N. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. O.ELECTRICAL CONTRACTOR SHALL ADHERE TO THE LATEST ADOPTED VERSION OF ALL APPLICABLE CODES AND ANY LOCAL ADDENDUM TO THOSE CODES. ELECTRICAL ABBREVIATIONS LEGEND A, AMP AMPERES AC ALTERNATING CURRENT A/C AIR CONDITIONING AF AMP FUSE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AL ALUMINUM AS AMP SWITCH ATS AUTOMATIC TRANSFER SWITCH BAS BUILDING AUTOMATION SYSTEM BKR BREAKER C RACEWAY/CONDUIT CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING C.O.RACEWAY/CONDUIT ONLY, WITH PULL STRING CNTRL CONTROL CU COPPER D EXISTING TO BE DEMOLISHED DISC DISCONNECT DIST DISTRIBUTION DPDT DOUBLE POLE DOUBLE THROW DWG DRAWING EA EACH EF EXHAUST FAN ELEC ELECTRIC EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT EX, EXIST EXISTING FA FIRE ALARM FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FD FUSED DISCONNECT FLR FLOOR FO FIBER OPTIC FSD FIRE SMOKE DAMPER RELAY, CONTROLLED BY ASSOCIATED SMOKE DETECTOR AND CIRCUITED BACK TO FACP FVNR FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING GEC GROUNDED ELECTRODE CONDUCTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER GFP GROUND FAULT PROTECTION GND GROUND GRC GALVANIZED RIGID CONDUIT HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HP HORSEPOWER HPS HIGH PRESSURE SODIUM HTR HEATER HVAC HEATING, VENTILATION & AIR CONDITIONING HZ HERTZ J-BOX JUNCTION BOX KVA KILOVOLT-AMPERES KW KILOWATTS LCP LIGHTING CONTROL PANEL LPW LUMENS PER WATT LTG LIGHTING LV LOW VOLTAGE MAG MAGNETIC STARTER MAN MANUAL MAX MAXIMUM MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MH METAL HALIDE MIN MINIMUM MSS MOTOR STARTER SWITCH WITH THERMAL OVERLOADS N NEUTRAL NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFD NON-FUSED DISCONNECT NIC NOT IN CONTRACT NO NORMALLY OPEN #NUMBER OAE OR APPROVED EQUAL OC ON CENTER OCPD OVERCURRENT PROTECTIVE DEVICE OH OVERHEAD P POLE PB PUSHBUTTON PH PHASE PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT PWR POWER R EXISTING TO REMAIN RCPT RECEPTACLE RECEPT RECEPTACLE RGS RIGID GALVANIZED STEEL RM ROOM RVNR REDUCED VOLTAGE NON-REVERSING RVR REDUCED VOLTAGE REVERSING SP SINGLE POLE TOGGLE SWITCH SPD SURGE PROTECTIVE DEVICE (TVSS) SPEC SPECIFICATION SPST SINGLE POLE SINGLE THROW SSPB START-STOP PUSHBUTTON SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TB TELEPHONE BOARD TC TIME CLOCK TD TIME DELAY TEL TELEPHONE TSP TWISTED SHIELDED PAIR TTB TELEPHONE TERMINAL BOARD TYP TYPICAL UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERES VFD VARIABLE FREQUENCY DRIVE W WATTS WP WEATHERPROOF W/O WITHOUT XFMR TRANSFORMER Y WYE-CONNECTED ∆DELTA-CONNECTED ø PHASE ABBREVIATIONS AND SYMBOLS GENERAL NOTES A. THE ABBREVIATIONS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT. B. THE SYMBOLS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT. C. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED. ELECTRICAL LOW VOLTAGE LEGEND FIRE ALARM SYSTEM TELEPHONE/DATA SYSTEM SPRINKLER PRESSURE SWITCH SPRINKLER FLOW SWITCH SPRINKLER TAMPER SWITCH DOOR HOLDER MANUAL STATION (MOUNT AT +46", UNO) STROBE -WALL MOUNT (+90"), CEILING MOUNT HORN/STROBE -WALL MOUNT (+90"), CEILING MOUNT SPEAKER STROBE -WALL MOUNT (+90"), CEILING MOUNT TELEPHONE OUTLET (MOUNT AT +18", UNO). SEE NOTE. VOICE-DATA OUTLET (MOUNT AT +18", UNO). SEE NOTE. DATA OUTLET (MOUNT AT +18", UNO). SEE NOTE. WIRELESS ACCESS POINT CABLE TRAY OR BASKET TRAY -LENGTH AND HEIGHT PER PLAN SECURITY SYSTEM CARD READER -SEE ELECTRICAL DETAILS FOR ROUGH-IN (MOUNT AT +46", OR MATCH ADJACENT DOOR ACCESS CONTROL) REQUEST TO EXIT MOTION DETECTOR DOOR CONTACTS ELECTRIC STRIKE ELECTRIC LOCK MOTION DETECTOR GLASS BREAK DETECTOR CCTV CAMERA -CEILING MOUNT OR WALL MOUNT. SEE NOTE. NOTE:PROVIDE ROUGH-IN ONLY. SINGLE GANG BOX WITH MUD RING & 1" C. STUBBED UP TO ACCESSIBLE CEILING SPACE. NOTE:PROVIDE ROUGH-IN ONLY. 2-GANG BOX WITH MUD RING & 1" C. STUBBED UP TO ACCESSIBLE CEILING SPACE. HEAT DETECTOR SMOKE DETECTOR -PHOTO-ELECTRIC SMOKE DETECTOR "X" INDICATES TYPE: D -DUCT SMOKE DETECTOR E -ELEVATOR SMOKE DETECTOR, A DEVICE THAT TRIGGERS ELEVATOR RECALL FOLLOWED BY SHUNT TRIP OF BREAKERS SERVING THE ELEVATOR AND ELEVATOR SHAFT PER NFPA 72 17.7.3.11, 17.7.3.1.3, 21.3.5.1 AND 21.3.5.2 SINGLE-STATION SMOKE DETECTOR. PROVIDE 120V AND MONITOR AT FACP VIA RELAY. COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR HEAT DETECTOR "X" INDICATES TYPE: RC -COMBINATION RATE-OF-RISE HEAT AND CO DETECTOR L -RATE-OF-RISE HEAT DETECTOR WITH 50' SPACING CRITERIA S -RATE-OF-RISE HEAT DETECTOR WITH 50' SPACING CRITERIA E -ACTIVATES SHUNT TRIP WITHOUT DELAY X x ELECTRICAL ONE-LINE LEGEND MOTOR SYMBOL CT AND CUSTOMER POWER METER UTILITY ELECTRIC METER AND BASE (BASE BY CUSTOMER) SURGE PROTECTION DEVICE LIGHTNING ARRESTOR STRESS RELIEF CONE POWER FACTOR CORRECTION CAPACITOR MOTOR STARTER SWITCH W/ THERMAL OVERLOADS CONTACTOR NORMALLY OPEN, NORMALLY CLOSED TRANSFORMER, 3-PH, 3-WIRE DELTA CONNECTION TRANSFORMER, 3-PH, 4-WIRE GROUNDED WYE CONNECTION AUTOMATIC TRANSFER SWITCH VARIABLE FREQUENCY DRIVE FIXED MOUNT LV BREAKER FUSED SWITCH ("XXAS/XXAF" -SW AND FUSE AMP RATING) GENERATOR WALL MOUNTED BREAKER THERMAL OVERLOAD ELEMENT DISCONNECT SWITCH ("XXAS" = SWITCH AMP RATING) FUSED DISCONNECT SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING) COMBINATION MOTOR STARTER (STR SIZE, TYP, AS, AF, SEE MEP COORDINATION SCHEDULE) SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, PHASE, NUMBER OF WIRES WHEN INDICATED ELECTRICAL POWER LEGEND PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT TO EACH DEVICE (PANEL NAME -CIRCUIT NUMBER). A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDED WITH EACH HOME RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE WIRING IS NOT SHOWN ON PLANS. "X" INDICATES TYPE: GFI -GROUND FAULT INTERRUPTER WP -WEATHERPROOF WHILE-IN-USE COVER USB -PROVIDE WITH (1) USB-A AND (1) USB-C PORTS PANELBOARD OR LOAD CENTER JUNCTION BOX FLATSCREEN TV BOX: 2-GANG, FLUSH IN WALL, HUBBELL HRWB25WHT, WITH WHITE COVER. DUPLEX RECEPTACLE & SINGLE GANG DATA PORT. COORDINATE HEIGHT WITH ARCHITECTURAL DRAWINGS OF TV HEIGHT, TV MOUNTING BRACKETS, AND WALL BLOCKING. PROVIDE 2" DATA CONDUIT TO FLOORBOX WITH PULLSTRING. DUPLEX RECEPTACLE -CEILING MOUNT, POP-UP COUNTERTOP MOUNT, WALL MOUNT (+18", UNO) QUADRUPLEX RECEPTACLE -CEILING MOUNT, WALL MOUNT (+18", UNO) FLOOR BOX WITH QUADPLEX RECEPTACLE -WITH 1-GANG TELE/DATA PORTS, WITHOUT TELE/DATA. INCLUDE ALL HARDWARE/ACCESSORIES AS REQUIRED. PROVIDE COVER (COORDINATE WITH ARCHITECT FOR FLOORING TYPE AND FINISH). SPECIAL PURPOSE RECEPTACLE (MOUNT AT +18", UNO) "(X)" INDICATES TYPE: (A) -NEMA 5-20R, #12 CU;(B) -NEMA 5-30R, #10 CU; (C) -NEMA 5-50R, #8 CU;(D) -NEMA 6-20R, #12 CU; (E) -NEMA 6-30R, #10 CU;(F) -NEMA 6-50R, #8 CU; (G) -NEMA 14-20R, #12 CU;(H) -NEMA 14-30R, #10 CU; (K) -NEMA 14-50R, #8 CU DROP-DOWN POWER OUTLET AND DATA OUTLET SURFACE MOUNTED PLUGSTRIP "X" INDICATES TYPE: A -PLUGSTRIP, POWER ONLY, OUTLET EVERY 3' OC B -WIREMOLD SERIES 4000 POWER AND DATA C -WIREMOLD SERIES 5000 POWER AND DATA SURFACE MOUNTED RACEWAY RACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN FINISHED SPACES, EXPOSED IN UNFINISHED SPACES RACEWAY BELOW FLOOR OR BELOW GRADE RACEWAY STUB-OUT WITH CAPPED END RACEWAY STUB-OUT WITH BRUSHED END GROUNDING BUS PUSHBUTTON (MOUNT AT +46", UNO) "X" INDICATES TYPE: EPO -EMERGENCY POWER OFF ADA -HANDICAPPED ACCESSIBLE DOOR (DEVICE BY OTHERS) ODO -OVERHEAD DOOR OPERATOR (DEVICE BY OTHERS) "X" INDICATES TYPE: BLANK -3-GANG FLOOR BOX, SUITABLE FOR CONCRETE FLOOR SLAB CONSTRUCTION AND FLUSH MOUNTING. WIREMOLD MODULINK 880MP WITH COVER. (OAE) PROVIDE 2" DATA CONDUIT TO BACK OF TELEVISION(WHERE APPLICABLE) AND 1-1/4" DATA CONDUIT FOR ETHERNET CABLES. DATA DEVICE SHALL HAVE TV VIDEO CABLE FEED THRU(WHERE APPLICABLE) AND ETHERNET DATA PORTS. A -6" DIA., FIRE RATED POKE THROUGH FLOOR BOX PRE- POURED INTO CONCRETE FLOORS OR CORE DRILLED INTO CONCRETE FLOORS. HUBBELL S1R6PTFIT OR EQUAL WITH COVER, TV VIDEO CABLE FEED THRU(WHERE APPLICABLE) AND ETHERNET DATA PORTS. ABOVE COUNTER RECEPTACLE -MOUNT AT +4" ABOVE BACKSPLASH *ALL RECEPTACLES ARE TO BE TAMPER RESISTANT WHERE REQUIRED BY NEC 406.12. DUPLEX RECEPTACLE WITH USB-A AND USB-C PLUG-INS.USB NON-FUSED DISCONNECT RATED FOR CIRCUIT AMPACITY, VOLTAGE, AND POLES. NEMA 1 INDOORS. NEMA 3R OUTDOORS. ELECTRICAL LIGHTING FIXTURE LEGEND RECESSED PANEL LIGHT -NORMAL POWER -BACKUP POWER EXIT SIGN -WALL MOUNT, CEILING MOUNT. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE. -NORMAL SIGN -SIGN WITH EMERGENCY LIGHT FIXTURES SURFACE PANEL LIGHT -NORMAL POWER -BACKUP POWER SURFACE WALL MOUNT LED FIXTURE -NORMAL POWER -BACKUP POWER LINEAR LIGHT -SURFACE OR SUSPENDED -NORMAL POWER -BACKUP POWER POLE MOUNTED FIXTURE LIGHTED IN-GROUND BOLLARD -FORWARD LIGHT -ANNULAR LIGHT -BACKUP POWER PENDANT FIXTURE; HIGH BAY OR DECORATIVE -NORMAL POWER -BACKUP POWER DUAL HEAD EMERGENCY EGRESS BATTERY PACK -WALL MOUNT, CEILING MOUNT WALL MOUNTED SCONCE -NORMAL POWER -BACKUP POWER SURFACE DOWNLIGHT -NORMAL POWER -BACKUP POWER RECESSED CAN DOWNLIGHT -NORMAL POWER -BACKUP POWER RECESSED CAN WALL WASHER TRACK LIGHTING. SEE FIXTURE SCHEDULE AND LIGHTING PLANS. PENDANT MOUNT CAN DOWNLIGHT -NORMAL POWER -BACKUP POWER EXTERIOR WALL MOUNTED SCONCE -NORMAL POWER -BACKUP POWER ELECTRICAL LIGHTING CONTROL LEGEND OCCUPANCY/VACANCY SENSOR -CEILING MOUNT. WATTSTOPPER DT-355 OR EQUAL. TOGGLE SWITCH (MOUNT AT +46", UNO) "X" INDICATES TYPE: BLANK -SINGLE POLE 3 -INDICATES THREE-WAY 4 -INDICATES FOUR-WAY K -INDICATES KEYED SWITCH T -INDICATES TIMER P -INDICATES PILOT LIGHT OS -INDICATES WALL SWITCH OCC SENSOR WATTSTOPPER DW-301 (SINGLE OR DUAL DW-302 SWITCH) "(y)" INDICATES ZONE: (a) -INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE a (a,b) -INDICATES LIGHTING SWITCHES WITH MULTIPLE ZONES (a and b) OCCUPANCY/VACANCY SENSOR -CEILING MOUNT WATTSTOPPER LMDC-100, OR EQUAL PHOTOCELL -CEILING MOUNT WATTSTOPPER LMLS-400, OR EQUAL. STANDARD LIGHTING CONTROLS: SWITCHES AND LINE VOLTAGE DIMMERS DIGITAL LIGHTING CONTROLS: DLM DEVICES ON/OFF ROOM CONTROLLER WITH (1) RELAY WATTSTOPPER BZ-250, OR EQUAL ON/OFF/0-10V ROOM CONTROLLER WITH (1) RELAYS WATTSTOPPER DLM LMRC-211, OR EQUAL ON/OFF/0-10V ROOM CONTROLLER WITH (2) RELAYS WATTSTOPPER DLM LMRC-212, OR EQUAL BUTTON ON/OFF WALL SWITCH WATTSTOPPER LMSW-210, OR EQUAL R1 R1 R2 ON/OFF/0-10V ROOM CONTROLLER WITH (3) RELAYS WATTSTOPPER DLM LMRC-213, OR EQUAL R3 OS VS OS VS P SX(y) S 0-10V DIMMING SWITCH WATTSTOPPER DCLV2, OR EQUAL. UNO ON DRAWINGS D OS VS OCCUPANCY/VACANCY SENSOR -WALL MOUNT WATTSTOPPER LMDX-100, OR EQUAL 24VDC LOW VOLTAGE DEVICES OCCUPANCY/VACANCY SENSOR -CEILING MOUNT WATTSTOPPER DT-300, OR EQUAL OS VS OS VS OCCUPANCY/VACANCY SENSOR -WALL MOUNT WATTSTOPPER DT-205, OR EQUAL MOMENTARY ON/OFF SWITCH (MOUNT AT +46", UNO) WATTSTOPPER LVSW-101, OR EQUALSX LOW VOLTAGE DIMMING SWITCH WATTSTOPPER LMSW-241, OR EQUAL. 4-SEPARATE SCENE SELECTOR BUTTONS AND DIMMING ROCKER SWITCH SCENE SELECTOR BUTTONS SHALL BE UN-ENGRAVED AND SET TO 25%, 50%, 75%, AND 100% LIGHTING OUTPUT. BUTTONS MAY BE CUSTOM ENGRAVED AND SET TO DIFFERENT LIGHTING OUTPUTS AS REQUESTED BY OWNERSHIP. OPTIONS SHALL BE COORDINATED PRIOR TO PROCUREMENT OF DEVICES, AND MAY BE INCLUDED IN SUBMITTAL FOR REVIEW. D NOTE:WHERE SENSORS ARE SHOWN AS "OS", POWERPACK SWITCH SHALL BE SET TO "AUTO-ON" FOR LIGHTS TO AUTOMATICALLY TURN ON WHEN SENSOR DETECTS MOTION. WHERE SENSORS ARE SHOWN AS "VS", POWERPACK SWITCH SHALL BE SET TO "MANUAL-ON" FOR LIGHTS TO TURN ON ONLY WHEN AN "ON" WALL SWITCH IS PRESSED. NOTE:WATTSTOPPER LMLS-500, OR EQUAL WHERE NOTED SPECIFICALLY ON DRAWINGS. 24VDC NOTE:MOMENTARY ON/OFF SWITCHES AND 0-10V DIMMING SWITCHES SHALL NOT BE WIRED TO THE SAME POWERPACK. LIGHT FIXTURE CONTROLS WILL BECOME OUT OF SYNC. GENERAL NOTE:LIGHTING CONTROLS MAY BE SUBSTITUTED WITH DIFFERENT MANUFACTURER PRODUCTS IF QUALITY AND FUNCTION ARE EQUAL. DEVICES SHOWN ON DRAWINGS ARE TO SHOW DESIGN INTENT. FINAL LIGHTING CONTROLS CONSTRUCTION SHOP DRAWINGS SHALL BE PROVIDED BY A MANUFACTURER CONTROLS ENGINEER. ALL CONTROLS WIRING DIAGRAMS AND WIRING REQUIREMENTS SHALL BE REFERENCED SPECIFICALLY FROM THE LIGHTING CONTROLS MANUFACTURER, WHETHER SHOWN ON THESE DRAWINGS OR NOT. LIGHTING CONTROLS MANUFACTURER SHALL BE CAPABLE OF PROVIDING ON-SITE FIELD SUPPORT AND TELECOMMUNICATIONS SUPPORT AS REQUIRED BY INSTALLING CONTRACTOR. SHEET NUMBER PROJECT CODE PROJECT ADDRESS ARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS. DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ON DRAWING SHEET AND MAY NOT BE REPRODUCED OR USED FOR OTHER PURPOSES WITHOUT WRITTEN PERMISSION FROM ARCHITECT. FOR SITE PLAN REVIEW ONLY 2042 Stadium Dr SUITE 2 BOZEMAN, MT 59715 SHEET NAME PROJECT NAME DRAWING REVISIONS DRAWING ISSUE DATE DRAWING ISSUED FOR PHONE: (406) 587-2917 Autodesk Docs://FWC - Ferguson Farm Office Building/FWC - First West Consulting Office Building R24.rvt4/8/2026 3:11:35 PME0.0 FWC FERGUSON FARM OFFICE BUILDING ELECTRICAL COVER SHEET 785 BOARDWALK AVE BOZEMAN, MT 59718 SITE PLAN 2026-04-10 SHEET LIST - ELECTRICAL E0.0 ELECTRICAL COVER SHEET E0.1 ELEC - SITE PLAN E0.3 ELEC - PHOTOMETRIC SITE PLAN E0.4 ELEC - PHOTOMETRIC ELEVATION PLAN E2.3 ELEC - LIGHTING SCHEDULES io.*.{h Si*'.\ i-...1'$t* t i sr*r i t No.' oTffi'l*t* Kiffiifi:.ffi uqt.oi1*'