HomeMy WebLinkAbout012 - C1.1 - CIVIL DETAILSCONNECT TO GUTTER DOWNSPOUT 6" SCHED. 40 PVC 6" X 12" PVC WYE 12" PVC STORM DRAIN SCALE: N.T.S.7 ROOF DRAIN CONNECTION TO STORM SEWER SCALE: N.T.S.4 UTILITY TRENCH TYPE 2 PIPE BEDDING WHERE REQUIRED FOR SOFT OR UNSTABLE FOUNDATION TYPE 1 PIPE BEDDING PLACED IN 6" MAX. LAYERS AND COMPACTED THOROUGHLY SELECT TYPE 1 BEDDING MATERIAL PLACED IN 6" LAYERS AND COMPACTED THOROUGHLY NOTE: SLOPING, BENCHING OR SUPPORT SYSTEMS SHALL CONFORM W/ O.S.H.A. CONSTR. STANDARDS FOR EXCAVATIONS. MOUND TRENCH W/ 6" NATIVE TOPSOIL OR SUBGRADE PREP. AS REQ'D TYPE 'A' OR 'B' TRENCH BACKFILL AS PER PLANS TRENCH WIDTH = SEE SCHEDULE INSTALL DETECTABLE WARNING TAPE 1.5' MAX DEPTH (SEWER)MINIMUMDEPTH COVER6" 4" SEE SCHEDULE NOTES: 1.SEE O.S.H.A. CONSTRUCTION STANDARDS FOR EXCAVATIONS. 2.TYPE 1 PIPE BEDDING SHALL BE GRAVEL, GRAVEL-SAND, OR SAND. THE MATERIAL SHALL BE WELL GRADED AND SHALL CONFORM TO THE SOIL TYPE GW (GRAVEL, WELL GRADED) OR SW (SAND, WELL GRADED) OF THE UNIFIED SOIL CLASSIFICATION SYSTEM (USCS). THE MAXIMUM SIZE GRAVEL SHALL BE 3 4 IN. TYPE 1 BEDDING CONSISTS OF MIN 4", OR 1 8 THE OUTSIDE DIAMETER OF THE PIPE, WHICHEVER IS GREATER, UNDER THE PIPE AND A MIN. OF 6" ABOVE THE PIPE. PLACE IN MAX. LIFTS OF 6" USING HAND OR OTHER COMPACTION METHODS W/O DAMAGING OR DISTURBING THE PIPE. THOROUGHLY COMPACT EACH LAYER. 3.TYPE "B" BACKFILL - PLACE BACKFILL IN MAXIMUM 8" LIFTS WITHIN 3% OPTIMUM MOISTURE CONTENT, AND COMPACT TO AT LEAST 90% OF MAXIMUM DENSITY AS DETERMINED BY AASHTO T99 OR BY ASTM D698. 4.TYPE 'A' BACKFILL: PLACE TRENCH BACKFILL IN MAX. 8" COMPACTED LIFTS W/IN 3% OF OPTIMUM MOISTURE CONTENT, AND COMPACT TO AT LEAST 95% OF MAX. DRY DENSITY DETERMINED BY AASHTO T99 OR BY ASTM D698. 5.SLOPING, BENCHING OR SUPPORT SYSTEMS SHALL CONFORM WITH O.S.H.A. CONSTRUCTION STANDARDS FOR EXCAVATIONS. HIGH DENSITY RIGID FOAM INSULATION BOARD AS NEEDED SCALE: N.T.S.1 TYPICAL CLEAN-OUT AT BUILDING PVC FROM HOUSE TO SEPTIC TANK WITH MIN 14" PER FOOT SLOPE (INSULATE). GROUND ELEVATION VARIES NOTE: INSULATE FROM HOUSE TO TANK TO 6' EQUIVALENT BURY DEPTH. 1" OF INSULATION = 1' BURY DEPTH RIGID INSULATION APPROVED FOR BURY, AS NECESSARY 3' FROM BUILDING CONTROL PANEL MOUNTED AT ENGINEER/OWNER APPROVED LOCATION CLEANOUT, ADDITIONAL CLEANOUT EVERY 50' FIRE SERVICE LINE GENERAL NOTES: 1. THE FIRST FITTING INSIDE THE BUILDING SHALL BE A UL LISTED FLANGED OS&Y VALVE THE SAME SIZE AS THE FIRE SERVICE LINE. 2. HORIZONTAL INSTALLATIONS MUST BE A MINIMUM OF 2' ABOVE THE FINISHED FLOOR. 3. THE FIRE SERVICE RISER MUST BE A MINIMUM OF 2' CLEAR FROM ANY OUTSIDE WALL, AND A MINIMUM OF 1' CLEAR FROM ANY INTERIOR WALLS. 4. THE INCOMING FIRE SERVICE LINE SHALL BE A MINIMUM 6.5', AND A MAXIMUM OF 7.5' BELOW THE FINISHED GRADE. 5. ALL FIRE SERVICE LINE APPURTENANCES SHALL HAVE A MINIMUM PRESSURE RATING OF 175 PSI. 6. IF MEGALUGS ARE USED IN LIEU OF THRUST BLOCKS, MINIMUM TEST PRESSURE OF 200 PSI IS NEEDED. 7. ALL FIRE SERVICE LINES LARGER THAN 4" SHALL BE CLASS 51 DUCTILE IRON PIPING, U.N.O.. 8. INSTALL THRUST BLOCKING PER MPWSS & APPLICABLE CITY PWSS. 9. INSTALL FIRE SERVICE LINE PER APPLICABLE CITY STANDARD DETAIL. FIRE SERVICE LINE CLASSIFICATION FOR BACKFLOW PREVENTION IS CLASS I 10. PROVIDE FLEXIBLE, WATER-TIGHT CONNECTION FOR ALL WALL AND FLOOR PIPE PENETRATIONS. THRUST BLOCK CL. 51 D.I. 90° BEND(S) W/ MJ FITTINGS THRUST BLOCKING @ FITTINGS AS NEEDED 5 8" Ø REDI ROD (TYP. OF 2). INSTALL FROM MJ 90° BEND TO FLANGE AT O.S.&Y. VALVE. INSTALL NON-ADJACENT AT 2 OF THE 4 MJ BOLT HOLES. CL. 51 D.I. RISER PIPE. INSTALL PLUMB AND LEVEL FLANGE TO BE THREADED ON STANDPIPE. MJ TO FLANGE ADAPTERS ARE NOT ACCEPTABLE. ELEV.= FIELD VERIFY TOP OF ADAPT./SPOOL(6") ELEV.= FIELD VERIFY BLDG. F.F. ELEV. TOP OF SLAB ELEV.= FIELD VERIFY F.S. LINE FIRE SUPPRESSION EQUIP. OR CITY METER/BACKFLOW ASSEMBLYFLOOR PENETRATION DETAIL FLOOR SLAB SCH 40 PVC PIPE SLEEVE - SEE SCHEDULE CAULK SEAL ON BACKING MAT'L PROCESS PIPING FITTINGS & BENDS PER PLAN PIPE SIZE SLEEVE SIZE 3"4" 4"6" 6"8" FLANGED MUELLER O.S.&Y. RESILIENT WEDGE GATE VALVE. POSITION PARALLEL WITH ADJACENT WLL PIPE PER PLAN COUPLING FOR PVC TO DI PIPE SCALE: N.T.S.2 TYPICAL FIRE LINE RISER DTL. GATE VALVE W/ VALVE BOX 8"10" SCALE: N.T.S.3 WATER SERVICE LINE FROM CURB STOP SCALE: N.T.S.6 SIDEWALK/PATIO SECTION 6" BASE COURSE 4" CONCRETE SCALE: N.T.S.5 CONCRETE CURB AND GUTTER SHEET NUMBER PROJECT CODE PROJECT ADDRESS ARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS.DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ONDRAWING SHEET AND MAY NOT BE REPRODUCED OR USEDFOR OTHER PURPOSES WITHOUT WRITTEN PERMISSIONFROM ARCHITECT. FWC FERGUSON FARM OFFICE BUILDING 785 BOARDWALK AVE BOZEMAN, MT 59718 SITE PLAN REVIEW 161 W. HALEY SPRINGS ROAD SUITE 101 BOZEMAN, MT 59718 SHEET NAME PROJECT NAME DRAWING REVISIONS DRAWING ISSUE DATE DRAWING ISSUED FOR 2026-01-30 PHONE: (406) 587-2781 FOR SITE PLAN REVIEW ONLY M O NTANA BRETT C. No. 29106 PE MEGAARD PE FOR S OI LNA S RE N IGENEPRELIMINAR Y C1.1 CIVIL DETAILS 012