Loading...
HomeMy WebLinkAbout052 - L2.7 - IRRIGATION DETAILS L2.7 IRRIGATION DETAILS PVC SCH 40 ELL \��\/ J � PVC SCH 80 NIPPLE \� / PVC SCH 40 COUPLING WATERPROOF CONNECTIONS �� DECODER, PER SCHEDULE/SPECS � RECTANGULAR VALVE BOX � TOP OF MULCH OR FINISH GRADE EMITTER, PER SCHEDULE L� LAMINATED TAG W/ ZONE NUMBER Yq�� DISTRIBUTION PVC SCH 80 NIPPLE TUBWG FlNISH GRADE PVC SCH 80 UNION PoR Yq��TUBING STAKE; DO QUICK COUPLING VALVE, IN A ROUND OR I SERVICMG ASSY. NOT PENEfRATE ROOT RECTANGULAR VALVE BOX RECTANGULAR VALVE BOX, PER SCHEDULE PVC SCH 40 MALE ADAPTER BALL PE LATERAL DRIP PIPE � 3" MIN. DEPTH OF�" MINUS ' -` _ ZO SCHEDULE 80 PVC THREADED WASHED ROCK �'� NIPPLES; LENGiH AS REQUIRED BLOCK (1 OF 4) SINGLE OUTLET '�, ` � ,.._..._ RN. GRADE o o PRESSURE � j ___.-___. SCHEDULE 40 PVC °��O �o COMPENSATING w ��. FlTTINGS, NPICAL INLINE PRESSURE REGULATOR EMITTER; SEE ! � �' BRICKS (1 OF 2) REMOTE CONTROL VALVE, PER IRRIGATION �_.- � _..__ SCHEDULE 18" MIN. BALL VALVE (1.5-INCH MAMLINE WLWE WYE RLTER SCHEDULE FOR FLOW _ _ i AND SMALLER), SEE pIPE� BALL VALVE SCHEDULE/SPECIRCATIONS PVC MAINLINE MAIN LINE PVC SCH 40 TEE OR ELL NOTES: 3/4-INCH MINUS PVC SCH 80 NIPPLE (2-INCH LENGTH 1. PLACE EMITTER(S)AT THE BASE OF THE ROOTBALL. � GRAVEL HIDDEN) AND PVC SCH 40 ELL SEE SCHEDULE FOR THE iOiAL NUMBER OF EMITTERS H UNIONS AND FLOW PER PLANT. 0 6" DEPTH WASHE� 3/a" ROCK NOTES: 2. SPACE MULTIPLE EMITTERS EVENLY AROUND THE 1. PROVIDE DRIP ZONE CONTROL TO SUPPORT DRIP ZONE. LOCATION, ROOTBALL. PLACEMENT AND CONNECTION OF DRIP ZONE CONTROL TO BE 3. PROVIDE DRIP EMITTERS FOR ALL PLANTS LOCATED w COORDINATED WITH OWNER'S REPRESENTATNE. IN ALONG DRNEWAY AND IN PLANTING BEDS. � MANUAL ISOLATION VALVE QUICK COUPLING VALVE DRIP ZONE CONTROL /� DRIP EMITTER PLACEMENT 1 NOT TO SCALE � NOT TO SCALE � NOT TO SCALE T � NOT TO SCALE O PVC SUPPLY PIPE, SIZE AS PER PLAN WITH MINIMUM SIZE 1" DIAMEfER x � o � O DRIPLWE CONNECTION TO BELOW GRADE L � INSIDE wALL � Z LATERAL PIPE, SEE DRIPLINE TO LATERAL � �' � ADAPTER CONNECTION DEfAIL � -� 18" � $ 3 O 1/2�� PLOYEfHYLENE BLANK TUBING, � -� AS REQUIRED �� 6' FlNISH GRADE � � r O4 BARB CROSS INSERT RTTING � -o MAKE ALL SPLICES IN VALVE BOXES & I i� �� �W LOCATE ON AS-BUILT PLANS. TIE A LOOSE � 1O TWO-WIRE DECODER CONTROLLER: � 4 � 20 FT. LOOP IN WIRING AT ALL CHANGES IN R41N BIRD ESP-LXD TWO-WIRE DECODER CONTROLLER �� OS BARB TEE INSERT FliTING DIRECTION GREATER THAT 30 DEGREES AND IN IN LXMM MEfAL CABINEf WITH OUTSIDE WALL MOUNT. VALVE BOXES. UNTIE ALL LOOPS AFTER DIRECT BURY INSTALL CONTROLLER AND CABINET ON WALL PER � 3 5 � MAKING CONNECTIONS. COMROL WIRE SECTION MANUFACTURER'S RECOMMENDATIONS. � � O AT-GRADE DRIPLINE, INNER RING 12" FROM \ PLANT, OUTTER RING 30" FROM PLANT, RAIN DRAWN BY: AMR PLACE ALL WIRING UNDER PAVEMENT AND � � � \ BIRD XFS-CV-09-12 DRIPLWE THROUGH SLEEVES IN CONDUIT. TIES O2 JUNCTION BOX � 1 DESIGNED BY: AMR CONTRACTOR HAS THE OPTION TO TRENCH LOOP O3 1-INCH CONDUIT AND FITTINGS TO POWER SUPPLY � / �2�� � I OO P�NT TRUNK QUALITYCHECK: JCC OR PULL P.E. DRIP LATERAL LINES, �o/�7/7 I � I DATE: 72-OS-25 PROVIDED A MINIMUM COVER OF 10" CAN L_/�1LrJL/ �OQD OO POWER SUPPLY WIRE � 1 � � O METAL TIE-DOWN STAKE, SEE NOTES JOB NO. 25-160 BE GUARANTEED. � � � FIELDBOOK �2�� DIRECT BURY PLAN O5 2-INCH CONDUIT AND FITTINGS FOR TWO-WIRE CABLE 1 � \ � ��� O DRIPLWE BARBED WSERT ELL o � FINISH GRADE � � FINISH GR4DE O6 MAXICABLE TWO-WIRE PATH TO DECODERS � � _ O•. X , USE A DIFFERENT CABLE JACKET COLOR FOR EACH � � cy �8,� �8„ ' 2 5 PATH. � o L4TERAL ��' 6 � 1 O 2 PINCH CLAMPS AT ALL BARBED � CONNECTIONS �O � MAWLWE — �2' � NOTES: � �� INSERT ADAPTER � LATERAL 1. ESP-LXD CONTROLLER COMES WITH 50 STATIONS N BEDDING 3 AVAILABLE. TWO ADDITIONAL 75 STATION � � N __ SECTIONS ESPLXD-SUM75 MODULES MAY BE ADDED TO EXPAND � � � � ,_ � � RUBBER GROMMET THE CONTROLLER UP TO 200 TOTAL STATIONS. w 120V WIRE 2. USE STEEL CONDUIT FOR ABOVE GRADE AND SCH 40 NOiE: a �q (� . SNAKE ALL 4 PVC CONDUIT FOR BELOW GRADE CONDITIONS. 1. PLACE TIE DOWN STAKES EVERY 3 FT.,AS � DRILL 5/8" HOLE IN PVC LATERAL � 1 _J_'�. '�. '�. LATER4L PIPE 6 3. PROVIDE PROPER GROUNDWG COMPONENTS TO WELL AS AT ALL CHANGE OF DIRECTION PIPE WHERE REQUIRED. ��FORSTNER�� o --- � �.j IN TRENCH ACHIEVE GROUND RESISTANCE OF 10 OHMS OR LESS. SUCH AS AT TEES OR ELLS. DRILL BIT REQUIRED FOR DRILLWG Z �� �'� j � 2. PROVIDE 2 PINCH CLAMPS AT ALL INSERT INTO PVC. REMOVE ANY EXCESS g ' PLANS FITTING CONNECTIONS. BURRS OR ROUGH EDGES. I / _': . ______. 0 � F TRENCH & BEDDING ESP-LXD TWO WIRE DECODER CONTROLLER TREE DRIP RING = � V NOT TO SCALE � NOT TO SCALE � NOT TO SCALE („) (n N � J � - W = H H ¢ U � W _ � NOTE: � �--------- ----------� REMOTE CONTROL VALVE 1. RECOMMENDED MINIMUM � � i PER IRRIGATION SCHEDULE FILTRATION: 120 MESH Z Z � i i 2. PRESSURE AT FLUSH VALVE SHALL BE M�N ,4.5 PS� IRRIGATION DETAIL SCHEDULE � � O TECHLINEOO START CONNECTION O N � � i i 3. 2 PSI CHECK VALVE (MAX 4.6' OF _ N � � PVC OR POLY SUPPLY 4. REFER TOLMAXIMUMCLENGTH)OF A DETAIL NOTES o i i HEADER SINGLE LATERAL CHARi LOCATE MANUAL ISOLATION BALL VALVES PER PLANS, EACH LOCATED IN VALVE a O Q �O i i 1. MANUAL ISOLATION VALVE BOXES TO ALLOW FOR REPAIRS, MAINTENANCE OR WINTERIZATION OF THE �J,J m � i i IRRIGATION SYSTEM. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATNE. �n i i SEE SPECIRCATIONS 0 � � � FOR ROW SPACING PROVIDE QUICK COUPLING VALVES PER PLANS. VALVE SHALL BE SEf A MINIMUM � � i i 2. QUICK COUPLING VALVE OF TWELVE INCHES (12") FROM SIDEWALKS, CURBS, OR PAVED AREAS. QUICK W � � � �\\\ COUPLWG VALVES SHALL BE HOUSED IN VALVE BOXES. _ � � i i� PROVIDE DRIP ZONE CONTROL TO SUPPORT DRIP ZONE EXACT LOCATION, � 3. DRIP ZONE CONTROL PLACEMENT AND CONNECTION OF DRIP ZONE CONTROL TO BE COORDINATED WITH ��j i i PERIMETER LATERALS OWNER'S REPRESENTATIVE. x- i i 2" TO 4" FROM EDGE '"ivi � � 4. DRIP EMITTER PLACEMENT PROVIDE DRIP EMITTERS FOR ALL PLANTS LOCATED IN THE PLANTING BED, �� i � TECHLINEOO CV DRIPLWE REFERENCE IRRIGATION EMIiiER SCHEDULE. ¢o i� i i v i i N a i �AREA PERIMETER 5. TRENCHWG & BEDDING TRENCH AND BED PER DEfAIL. Nim � � PVC OR POLY EXHAUST ~io i i HEADER 6. CONTROLLER WALL MOUNTED. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. M N i � MANUAL FLUSH VALVE o � PLUMBED TO PVC OR POLY N� 7. TREE DRIP RING ENSURE ALL RINGS ARE COVERED BY MULCH a c� �o w N N ETA F I M-T E C H L I N E CV E N D F E E D LAYO U T 8. NEfAFIM TECHLWE CV LAYOUT INSTALL PER MANUFACTURER'S SPECIFlCATIONS, ENSURE ALL PIPING IS COVERED �o w� Q BY SOIL PEP MULCH G25-160 L2.X.DW �? V NOT TO SCALE a a SHEET L'1,7