Loading...
HomeMy WebLinkAbout204 L2.2 - IRRIGATION SCHEDULES & NOTESESTIMATED WATER CONSUMPTIONWATER CONSUMPTION ESTIMATES ARE BASED ON ASEASONAL 24-WEEK WATERING WINDOW, AND ARELISTED IN ANNUAL TOTALSACRE FEET BASED ON SYSTEM DESIGN2,250 GAL/.WEEK = 0.17 AC.FT.ACRE FEET BASED ON VEGETATION TYPE SQUAREFEETTURF: 772 S.F. = 0.04 AC.FT.SHRUBS & GROUND COVER: 3,750 S.F. = 0.17 AC.FT.TREES: 35SF = 0.01 AC.FT.CRITICAL ANALYSISGenerated:2026-01-23 15:21P.O.C. NUMBER: 01Water Source Information:EXISTING POCFLOW AVAILABLEPoint of Connection Size:1"Flow Available18.2 GPMPRESSURE AVAILABLEStatic Pressure at POC:65 PSIPressure Available:65 PSIDESIGN ANALYSISMaximum Station Flow:16.91 GPMFlow Available at POC:18.2 GPMResidual Flow Available:1.29 GPMCritical Station:3 Design Pressure:40 PSI Friction Loss:0.04 PSI Fittings Loss:0 PSI Elevation Loss:0 PSI Loss through Valve:1.6 PSIPressure Req. at Critical Station:41.6 PSILoss for Fittings:0 PSILoss for Main Line:0.03 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:11.8 PSILoss for Master Valve:0.2 PSICritical Station Pressure at POC:53.7 PSIPressure Available:65 PSIResidual Pressure Available:11.3 PSICRITICAL ANALYSISFLOW TOTALSArea for Dripline:39.4Drip Ring:0.7Turf Rotary:3.5Total:43.6 GPMFLOW AVAILABLE18.2 GPMArea for Dripline:3 ValvesDrip Ring:1 ValvesTurf Rotary:1 ValvesTotal:5 ValvesNUMBERMODELTYPEPRECIPSUNMONTUEWEDTHUFRISATIN./WEEKMIN./WEEKGAL./WEEKGAL./DAY1HUNTER ICZ-101-25AREA FOR DRIPLINE1.45 in/h14 min14 min14 min1423631212HUNTER ICZ-101-25AREA FOR DRIPLINE1.2 in/h17 min17 min17 min1506942313HUNTER PGV-101GTURF ROTARY0.4 in/h38 min38 min38 min0.751123921314HUNTER ICZ-101-25AREA FOR DRIPLINE1.43 in/h15 min15 min15 min1437272425HUNTER ICZ-101-25-LFDRIP RING0.57 in/h36 min36 min36 min110674.224.7TOTALS:1201201203532,250749.9WATERING SCHEDULEIRRIGATION NOTES1.CONTRACTOR RESPONSIBLE FOR SCHEDULING PRE-INSTALLATION MEETING WITH CITY OF BOZEMAN WATERCONSERVATION DIVISION PRIOR TO COMMENCING ANY WORK.2.LANDSCAPE & IRRIGATION SELF-CERTIFICATION FORMS REQUIRED TO RECEIVE CITY OF BOZEMAN BUILDING PERMIT.3.CONTRACTOR RESPONSIBLE TO INFORM LANDSCAPE ARCHITECT OF ANY DISCREPANCIES OR CHANGES NEEDED TO THEIRRIGATION DESIGN. IF CONTRACTOR MAKES CHANGES TO THE IRRIGATION DESIGN WITHOUT NOTIFYING THELANDSCAPE ARCHITECT, CONTRACTOR ASSUMES FULL RESPONSIBILITY OF THE IRRIGATION SYSTEM DESIGN ANDFUNCTIONALITY.4.LANDSCAPE CONTRACTOR RESPONSIBLE FOR SCHEDULING A PUNCH-LIST SUBSTANTIAL COMPLETION INSPECTION ANDFINAL COMPLETION INSPECTION WITH LANDSCAPE ARCHITECT. PRIOR TO INSPECTIONS, IRRIGATION MAINLINE TO BECHARGED FOR A MINIMUM TWO HOURS AND VALVE BOXES AND EQUIPMENT HOUSINGS SHALL BE OPENED.5.CONTRACTOR RESPONSIBLE FOR PROVIDING IRRIGATION AS-BUILTS TO LANDSCAPE ARCHITECT WITHIN ONE WEEK OFFINAL COMPLETION INSPECTION.6.CONTRACTOR TO VERIFY STATIC PRESSURE IN THE FIELD PRIOR TO BIDDING AND CONSTRUCTION. IN THE EVENT OF ADISCREPANCY, CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IN WRITING OF ANY CHANGES NECESSARY TOPROVIDE THE REQUIRED OPERATIONAL PRESSURE AND FLOW. IF NOTIFICATION IS NOT RECEIVED, CONTRACTORASSUMES FULL RESPONSIBILITY FOR SYSTEM OPERABILITY.7.PROVIDE PRESSURE REDUCING VALVE UP STREAM OF BACKFOW ASSEMBLY IF PRESSURE EXCEEDS 80 PSI. REDUCE TO60PSI STATIC PRESSURE.8.INSTALLED SYSTEM TO BE FULLY WINTERIZEABLE. CONTRACTOR TO PROVIDE LANDSCAPE ARCHITECT WITHWINTERIZATION PLAN.9.PROVIDE FLUSH VALVES AT END OF EACH DRIP ZONE FOR FLUSHING AND WINTERIZATION. INSTALL AT LEAST ONE FLUSHVALVE AT LOWEST POINT OF SYSTEM FOR DRAINAGE. LOCATE VALVES IN ACCESSIBLE AREAS IN VALVE BOXES. SHOWALL FLUSH VALVE LOCATIONS ON AS-BUILT IRRIGATION PLAN.10.CONTRACTOR SHALL COORDINATE PLANTING WITH IRRIGATION INSTALLATION.11.THE CONTRACTOR SHALL INSPECT THE SITE AND VERIFY CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION.12.IRRIGATION PLANS ARE DIAGRAMMATIC REPRESENTATIONS ONLY. PLACE LINES IN A COMMON TRENCH WHENEVERPOSSIBLE. FIELD ADJUST LINES TO AVOID CONFLICT WITH UTILITIES. PLACE SPRINKLER HEADS A MINIMUM OF 2" FROMHARDSCAPE EDGES.13.IRRIGATION IS COORDINATED WITH THE PLANTING PLAN AND SITE IMPROVEMENTS AND IS DESIGNED WITHRECTANGULAR SPACING GIVING HEAD TO HEAD COVERAGE. COORDINATE IRRIGATION HEAD LAYOUT WITH NEW PLANTMATERIALS, LOCATE SPRAY HEADS 30" FROM BASE OF TREE. DO NOT ALTER HEAD LOCATION, PIPE LAYOUT, OR VALVELOCATION WITHOUT WRITTEN APPROVAL FROM THE LANDSCAPE ARCHITECT. NOTIFY LANDSCAPE ARCHITECT IFDISCREPANCIES OCCUR BETWEEN THE PLANS AND FIELD CONDITIONS.14.ALL COMPONENTS OF IRRIGATION SYSTEM SHALL BE INSTALLED AND PROPERLY ADJUSTED TO PROVIDE ADEQUATEHEAD TO HEAD COVERAGE AND ELIMINATE OVER SPRAY ONTO WALKS, BUILDINGS, PARKING AREAS, ETC.15.ALL PIPE SIZES INDICATED ARE MINIMUMS. CONTRACTOR MAY NOT DECREASE PIPE SIZE. LARGER PIPE SIZES MAY BEUSED AT NO ADDITIONAL COST TO OWNER. PIPE SIZES INCREASE IN SIZE DOWNSTREAM OF NEXT SPRAY HEAD, ASSHOWN.16.INSTALL ALL IRRIGATION PIPE AND CONTROL WIRES IN MINIMUM 4" PVC SLEEVE BELOW ALL PAVED SURFACES UNLESSOTHERWISE INDICATED ON THE PLANS. INSTALL SLEEVES PRIOR TO PLACEMENT OF PAVEMENTS AND PAVEMENTSUB-BASE. WHERE PAVEMENT EXISTS BORE AND PLACE SLEEVES.17.COORDINATE IRRIGATION POINTS OF CONNECTION AND LOCATION OF AUTOMATIC CONTROL VALVES WITH LANDSCAPEARCHITECT. COORDINATE ALL WORK WITH OTHER TRADES, I.E. ELECTRICAL, MASONRY, ETC.18.CONTRACTOR TO PROGRAM AUTOMATIC CONTROLLER TO ALLOW FOR THE EQUIVALENT OF 3/4" OF WATER PER WEEKFOR MANICURED LAWNS AND 1" PER WEEK FOR ALL OTHER PLANTINGS, OR PER SITE AND PLANTING NEEDS FOR BESTPLANT HEALTH.19.ALL PVC PIPES SHALL BE TRENCHED UNLESS PRE-APPROVED TO BE PULLED IN WRITING BY LANDSCAPE ARCHITECT.POLLY PIPE MAY BE PULLED. PROVIDE POSITIVE DRAINAGE OF MAINLINE. PLACE MANUAL DRAIN AT LOW POINTS INMAINLINE. IDENTIFY LOCATIONS ON AS-BUILTS.20.USE 45° ELBOWS INSTEAD OF 90° ELBOWS ON ALL MAINLINES 2-1/2" AND LARGER. INSTALL CMU THRUST BLOCKS AT ALLMAINLINE CHANGES IN DIRECTION FOR PIPE 2" AND LARGER .21.CONTRACTOR TO INSTALL CONTROLLER AND ACCESSORIES AS REQUIRED. CONTRACTOR TO FURNISH CONTROL WIRESFROM VALVES TO CONTROLLER. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING 110 VOLT SERVICE FROMEXISTING ELECTRICAL SERVICE AND CONNECTION TO CONTROLLER SERVICE.22.INSTALL ONE (1) ADDITIONAL RED CONTROL WIRE AND ONE (1) ADDITIONAL WHITE CONTROL WIRE FROM CONTROLLER TOEND OF MAINLINE.23.ALL TREES TO BE ON A DEDICATED DRIP ZONE FOR DROUGHT PREPARATION.24.ALL RAISED PLANTER BEDS TO BE ON A DEDICATED DRIP ZONE AND DAILY WATERING SCHEDULE.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYPSIHUNTER MP1000 PROS-06-PRS40-CVTURF ROTATOR, 6" POP-UP WITH CHECK VALVE, PRESSUREREGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY.M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC,O=OLIVE 360 ARC.1040SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER ICZ-101-25 1"DRIP CONTROL ZONE KIT. 1" ICV GLOBE VALVE WITH 1" HY100 FILTERSYSTEM. PRESSURE REGULATION: 25PSI. FLOW RANGE: 2 GPM TO 20GPM. 150 MESH STAINLESS STEEL SCREEN.3HUNTER ICZ-101-25-LF 1"DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH 1IN. HY100FILTER SYSTEM. PRESSURE REGULATION: 25 PSI. FLOW RANGE: .5GPM - 15 GPM. 150 MESH STAINLESS STEEL SCREEN.1HUNTER HDL-06-12-R DRIP RING5AREA TO RECEIVE DRIPLINEHUNTER HDL-06-12-PCHDL-06-12-PC: HUNTER DRIPLINE WITH 0.6 GPH FLOW. LIGHT BROWNTUBING WITH GRAY STRIPING. EMITTERS AT 12" O.C. DRIPLINELATERALS SPACED AT 12" APART, WITH EMITTERS OFFSET FORTRIANGULAR PATTERN. INSTALL WITH HUNTER PLD BARBED ORPLD-LOC FITTINGS.3,941 LFSYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER PGV-101G 1"1IN. PLASTIC ELECTRIC REMOTE CONTROL VALVE, FORRESIDENTIAL/LIGHT COMMERCIAL USE. FEMALE NPT INLET/OUTLET.GLOBE CONFIGURATION, WITH FLOW CONTROL.1HUNTER HQ-33DLRC 3/4"QUICK COUPLER VALVE, YELLOW LOCKING RUBBER COVER, REDBRASS AND STAINLESS STEEL, WITH 3/4IN. NPT INLET, 2-PIECE BODY.1LASCO FITTINGS TUBV-SC1", 1-1/2", 2", AND 3" PLASTIC FULL BLOCK TRUE UNION BALL VALVE.SHUT OFF/ISOLATION VALVE TO ELIMINATE WATER HAMMER. INSTALLSAME SIZE AS MAINLINE.1BUCKNER-SUPERIOR 3000 1"NORMALLY CLOSED BRASS MASTER VALVE THAT PROVIDES DIRTYWATER PROTECTION AND 3-WAY SOLENOID DESIGN. AVAILABLE IN 1",1-1/4", 1-1/2", 2", 2-1/2" AND 3" SIZES.1EXISTING BACKFLOW 1"350 DOUBLE CHECK BACKFLOW PREVENTER 3/4"-2"1HUNTER P2C-400LIGHT COMMERCIAL & RESIDENTIAL CONTROLLER, 4-STATION BASEMODULE CONTROLLER, 120 VAC, OUTDOOR/INDOOR MODEL1HUNTER WSSWIRELESS SOLAR, RAIN FREEZE SENSOR WITH OUTDOOR INTERFACE,CONNECTS TO HUNTER PCC, PRO-C, AND I-CORE CONTROLLERS,INSTALL AS NOTED. INCLUDES 10 YEAR LITHIUM BATTERY AND RUBBERMODULE COVER, AND GUTTER MOUNT BRACKET.1POINT OF CONNECTION 1"EXISTING POC1IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1"613.5 LFIRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1 1/2"57.0 LFIRRIGATION MAINLINE: PVC SCHEDULE 40 1 1/2"141 LFPIPE SLEEVE: PVC CLASS 200 SDR 2197.1 LFMLOMBFCRFPOCIRRIGATION SCHEDULEMMPERFORMANCE LANDSCAPE DESIGN PATHWAYSHEET No:JOB No:DATE:PREPARED FOR:REV:DATE:DESCRIPTION:LANDSCAPEARCHITECTURE614 S Ferguson Ave., Ste 3Bozeman, MT 59718(406) 624-9111hello@inContour.comwww.inContour.comDELTA GAMMA 410 WEST GARFIELD ST. BOZEMAN MT kkuntz.m5@gmail.com703 Wyoming Street Belgrade MT 59714FIRM 5 Hannah House Incorporated2534001/27/2026L2.2IRRIGATION SCHEDULE & NOTESSTAT E OFMONTANALANDSCAPEARCH ITECTLICENSE D LESSA R.MILLARD274