HomeMy WebLinkAbout005 A2.00 - MAIN FLOOR PLANSTORAGE
WEST STAIRS EAST STAIRS
MECH BED
KITCHEN
BATH
UP
STORAGE
1
1
2
2
AA
BB
3
3
4
4
5
5
LIFT
UP1
A4.00
1
A4.01
2
A4.01
3
A4.01
5
A4.00 30' - 0"18' - 0"
4' - 2"3' - 4"11' - 0"13' - 0"6' - 0"6' - 11"4' - 2"6' - 11"
2' - 0"4' - 2"5' - 10"4' - 0"2' - 0"4' - 0"4' - 0"4' - 0"8' - 0"
18' - 0"20' - 0"10' - 10"2' - 8"2' - 8"11' - 4"2' - 6"13' - 0"4' - 8"4' - 10"7' - 6"30' - 0"18' - 0"20' - 0"14' - 0"6' - 6"9' - 6"3' - 6"4' - 0"6' - 6"1' - 6"3' - 6"1' - 6"6' - 6"4' - 0"7' - 6"4' - 0"2' - 6"
0' - 6"
4' - 0"6' - 0"
7' - 0"13' - 0"
FURN
E.P.2' - 6"9' - 6"4' - 0"6' - 0"8 RISERS @ 6"7 TREADS @ 12"9' - 0"
10' - 0"
FOUNDATION
13' - 0"
CONCRETE LANDING -SAME
HEIGHT AS SIDEWALK
18 RISERS @ 6 7/8"
17 TREADS @ 11"
18 RISERS @ 6 7/8"
17 TREADS @ 11"HOOKS 18' - 0"74' - 0"
8' - 0"
4
A4.01
PAVERS / SIDEWALK-TBDTO FOUNDATION15' - 0"3
A3.01
DARKENED DASHED LINE
DENOTES METAL ROOF OUTLINE
LIGHTENED DASHED LINE
DENOTES UPPER ROOF
OUTLINE 4' - 0"4' - 2"4' - 2"1' - 2"4' - 2"1' - 0"FLOOR PLAN GENERAL NOTES
1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
2. ALL WORK SHALL COMPLY WITH APPLICABLE CODES LISTED.
3. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS UNLESS NOTED OTHERWISE. DRAWINGS SHOW THE DESIGN INTENT AND MAY NOT
SHOW ALL DETAILS FOR INSTALLATION.
4. ALL ELECTRICAL AND PLUMBING WORK SHALL BE INSTALLED BY LICENSED PROFESSIONAL(S) AND SHALL CONFORM WITH CURRENT CODES.
5. CONFIRM AND COORDINATE LOCATIONS OF ALL UTILITIES WITH CONTRACTOR.
6. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS.
7. ALL DIMENSIONS ARE FROM STRUCTURAL GRIDLINES OR UNFINISHED FACE OF STUD, UNLESS OTHERWISE NOTED.
8. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING CONSTRUCTION.
9. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
10. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
11. THE MEANS AND METHODS OF CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR.
12. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC.
13. PROTECTION OF PENETRATIONS OF WALL OR FLOOR/CEILING ASSEMBLIES REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH SECTION R302.2 OR R302.3.
14. THE FLAME SPREAD FOR WALLS AND CEILINGS FINISHED TO BE NOT GREATER THAN 200 (R302.9.1)
15. THE SMOKE-DEVELOPED INDEX FOR WALLS AND CEILINGS SHALL NOT HAVE AN INDEX GREATER THAN 450 (R302.9.2)
16. FIREBLOCKING VERTICALLY AT FLOOR AND CEILINGS, HORIZONTALLY AT INTERVALS NO GREATER THAN 10. CONCEALED SPACES (SOFFIT, DROP CEILINGS, MECH CHASES, ETC)
BETWEEN VERTICAL AND HORIZONTAL SPACES SHALL HAVE FIREBLOCKING.
17. SMOKE DETECTORS AND CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN EXISTING BEDROOMS AND HALLWAYS PER IRC 314 & 315.
18. CONTINUITY OF FIRE-RESISTANCE-RATING SHALL BE CONTINUOUS FROM FOUNDATION TO UNDERSIDE OF ROOF DECKING. SHALL EXTEND THE FULL LENGTH OF THE WALL OR
ASSEMBLY, INCLUDING EXTENSIONS.
19. ALL EGRESS WINDOWS FROM BEDROOMS SHALL HAVE A NEW CLEAR OPENING 5.7 SF AND A MAXIMUM SILL HEIGHT OF 42"
SCALE:
DRAWN:
PROJECT NO:
DATE:
As indicated
1/27/2026 10:55:53 AM
A2.00
24-015
Main Floor Plan
Delta Gamma
Site Alteration
Hannah House Inc.
410 West Garfield St.
Bozeman MT
3/16" = 1'-0"1 First Floor Plan
ISSUED FOR SITE PLAN