HomeMy WebLinkAbout055 P003 Building 5 Plumbing DetailsALL PIPING WITHIN 18" OF WATER
HEATER TO BE COPPER TYPE 'L'.
EXPANSION
TANK (PET-1)
DWH-1
THERMOMETER
DRAIN VALVE
ASME T&P RELIEF VALVE -
ROUTE TYPE 'L' FULL SIZE
TO DRAIN RECEPTOR
DRAIN PAN WITH SCH. 40 PVC
PIPE TO DRAIN RECEPTOR
1" DHW
ISOLATION VALVE -TYP
T
SEISMIC STRAPPING SHALL BE
LOCATED AT POINTS WITHIN
UPPER 1/3 AND LOWER 1/3 OF
WATER HEATER
ROUTE TP-1 DISCHARGE
DIRECTLY TO DRAIN
RECEPTOR
DCW LINE FROM
VERTICAL MAIN
1" DCW
1" DCW
NOTE: REFER TO UPC 2021
SECTION 908.2 FOR
ADDITIONAL INFORMATION
2" DRY VENT SIZED FOR
BATHROOM GROUP'S TOTAL
DRAINAGE FIXTURE UNITS (DFU)
DRY-VENTED LAVATORY
START OF WET VENT SHALL BE
ABOVE THE WEIR OF EACH
WET-VENTED FIXTURES TRAPS
2" WET VENT FOR 4 DFU
OR LESS AND 3" WET VENT
FOR 5 DFU OR MORE
WATER CLOSET CONNECTION
TO BE DOWNSTREAM OF
OTHER FIXTURES
OFFSET LAVATORY WET-VENT AND/OR
UPSIZE BATH/SHOWER TRAP ARM TO
MAINTAIN MAXIMUM TRAP ARM LENGTH
LISTED IN THE ABOVE TABLE
ONLY ONE WET-VENTED FIXTURE
MAY DISCHARGE UPSTREAM OF
THE DRY-VENTED LAVATORY
TRAP ARM DIA.
1-1/2"
2"
MAX LENGTH
3'-6"
5'-0"
TRAP PRIMER TAILPIECE -
INSTALL PER MANUF.
INSTRUCTIONS
TRANSITION TO TRAP PRIMER
PIPING WHERE CONCEALED
SINK / LAVATORY
FLOOR DRAIN/SINK
FINISHED FLOOR
FRAMED WALL
PROVIDE TRAP PRIMER CONNECTION
ON FLOOR DRAIN/SINK OR PROVIDE
TRAP PRIMER ADAPTER
PROVIDE PIPE ESCUTCHEON
1/2'' DCW PIPE TO TRAP PRIMER
CONNECTION -NO FITTINGS UNDERSLAB
INSTALL SLEEVE THRU
CONCRETE -SEAL WATERTIGHT
PREFABRICATED FLASHING
BOOT WITH MEMBRANE COLLAR
STAINLESS STEEL
CLAMP -TRIM EXCESS
TRANSITION TO
MINIMUM 3"ø VTR
LOCATE TRANSITION MINIMUM
12" BELOW ROOF DECK
HOLE THROUGH
ROOF DECK
APPLY WEATHER
SEALANT AT INTERFACE
FASTEN FLASHING
BOOT TO ROOF
ATTIC TRUSS -12" MIN
FROM BUILDING
TO SEWER MAIN
FINISH GRADE
RISER PIPE
45 DEGREE ELBOW -TYP
CLEAN OUT TO GRADE -SEE
CIVIL SITE PLAN
TWO-WAY CLEANOUT FITTING
SEE SITE CIVIL PLANS
FOR INVERT ELEVATION
SEE SITE UNDERSLAB PLUMBING
PLAN FOR INVERT ELEVATION
SINK
CLEANOUT
2" SAN
1-1/2" VENT
BRING VENT UP AS
HIGH AS POSSIBLE
HIGH LEVEL OF RIM OF
SINK OR COUNTER TOP
VENT UP IN WALL
WALL
2" SAN
INSTALL USING DWV
FITTINGS AND SLOPE AT A
MINIMUM OF 1/4" PER FOOT.
INTERIOR FLOOR CLEANOUTEXTERIOR CLEANOUT
(LIGHT TRAFFIC AREA)
FINISHED FLOOR
PIPE EXTENSION
SAME SIZE AS SEWER
UP TO 4" DIA.
6" THICK BY 18" SQUARE
CONCRETE PAD
"CO" TO BE CAST IN COVER
GRADE OR PAVING
CAST IRON CLEANOUT WITH
COVER FOR DUTY REQUIRED
LONG SWEEP 1/4 BEND OR
COMBINATION WYE & 1/8
BEND. (USE REDUCING TYPE
WHERE REQUIRED)
BUILDING DRAIN OR SEWER
MATERIAL AND SIZE AS SPECIFIEDSEE PLANSCLEANOUT TEE
FLOOR LINE
CONNECT TO WASTE LINE
STAINLESS STEEL WALL
COVER AND SCREW
WALL
EXTEND WASTE OR VENT
LINE WHERE INDICATED
12" MIN.EXISTING 18" X 18" X 24"
DEEP SUMP
ELEVATOR
PIT
SUMP PUMP SHALL BE 3000 GPH (50 GPM) AND
CONTROLLED VIA INTEGRAL FLOAT SWITCH TO PROVIDE
OPERATION WITHOUT HUMAN INTERVENTION.
OIL SENSOR CONTROL SYSTEM -MOUNT
ON DISCHARGE PIPE
1-1/2" DISCHARGE PIPE WITH CHECK VALVE
AND ISOLATION VALVE (LOCKED OPEN)
SUMP PUMP CONTROL
PANEL -CONNECT TO
EXISTING GFI OUTLET -
WIRE PER MANUF. INSTALL
INSTRUCTIONS
DISCHARGE INTO TOP OF ABOVE GRADE
SANITARY PIPE WITH SANITARY WYE 4'-0" MIN.1/2"ø DCW SUPPLY
WALL
INSTALL SLEEVE THRU
CONCRETE -SEAL WATERTIGHT
1/2'' DCW PIPE TO TRAP PRIMER
CONNECTION -NO FITTINGS UNDERSLAB
PROVIDE TRAP PRIMER CONNECTION
ON FLOOR DRAIN/SINK OR PROVIDE
TRAP PRIMER ADAPTER
FLOOR DRAIN/SINK
FINISHED FLOOR
BALL VALVE
TRAP PRIMER -SECURE TO
WALL PER SPECIFICATIONSUNION -PROVIDE WYE
SPLITTER WHERE REQUIRED
P
3"ø DCW
W
P
REDUCED PRESSURE BACKFLOW PREVENTOR -PIPE
AIR GAP TO FLOOR SINK -TYP
ISOLATION VALVE -TYP
PRESSURE GAUGE -TYP
PRESSURE REDUCING VALVE -SET TO 60 PSI -TYP
WATER METER (BY UTILITY) -TYP
STRAINER
TO BUILDING
SEE UNDERSLAB
PLAN -TYP
REDUCER
2' MAX1' MINOS&Y VALVE WITH STEM
PARALLEL TO FLOOR
W
P
4"ø DCW 2"ø IRR BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1
sheet:
title:
D
C
B
A
D
C
B
A
1 2 3 4 5
1 2 3 4 5
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
601 Euclid Ave. Suite C
Helena, Montana
59601
406-531-4745
unitedhousingpartners.com
UHP Design LLC
406-224-8220
revisions :
p r o j e c t # :
d a t e :
KEY PLAN
project:
stamp
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
m-m.net
2880 Technology Blvd W, Bozeman, MT 59718
(406) 587-0721
P003
PLUMBING
DETAILS
100% CD SET
2025.11.26
25.0275
ADDRESS: BOZEMAN, MT
Hidden Creek
Building 5
N.T.S.1 WATER HEATER SCHEMATIC (DWH-1)
N.T.S.2 HORIZONTAL BATHROOM GROUP VENTING DETAIL
N.T.S.6 TAILPIECE TRAP PRIMER DETAIL (TP-2)
N.T.S.11 VENT THRU ROOF DETAIL
N.T.S.3 BUILDING SEWER SERVICE DETAIL
N.T.S.7 PENINSULA FIXTURE VENTING DETAIL
N.T.S.8 SEWER LINE CLEANOUT DETAIL
N.T.S.9 SEWER LINE CLEANOUT THRU WALL DETAIL
N.T.S.10 ELEVATOR SUMP PUMP DETAIL
N.T.S.5 TRAP PRIMER DETAIL (TP-1)
N.T.S.4 WATER SERVICE ENTRANCE
IS
SEFORP
LANO E N G INEERO N TM ANA
LICENS E D
DYLAN R.
JUNJAK
No. 76054 PE