HomeMy WebLinkAbout054 P100 Building 5 Plumbing PlanA1BCDEFGHIJ456789101112131415234E1014E100STAIR11142E1032E1042E1052E1062E1072E1082E1102E109STAIR21172F1112F1121E102ECO6" SAN11SP-110P0034P003WC-1BS-1WB-1L-1FD-1S-12" SAN UP3" SAN UP442BS-1WC-1L-1FD-1WB-1S-143" SAN UPWB-14" SAN UPL-2WC-2SH-1FD-1S-22" SAN UP44L-1WC-1BS-1S-244WB-1FD-1SH-1L-2WC-24L-1WC-1BS-1S-22" SAN UP3" SAN UP44WB-1FD-1SH-1L-2WC-24336" FP1P4012P4012P4012P4012P4012P4012P4012P4012P4011P4021P4022P4022P402FCOFCOBS-1WC-1L-1FD-1WB-1S-143" SAN UP3BS-1WC-1L-1FD-1WB-1S-143" SAN UP3BS-1WC-1L-1FD-1WB-1S-143" SAN UP3BS-1WC-1L-1FD-1WB-1S-143" SAN UP3BS-1WC-1L-1FD-1WB-1S-143" SAN UP3BS-1WC-1L-1FD-1WB-1S-143" SAN UP3BS-1WC-1L-1FD-1WB-1S-143" SAN UP33" SAN UP4" SAN4" SAN4" SAN4" SAN4" SAN4" SAN4" SAN4" SAN4" SAN4" SAN4" SAN4" SAN24" SAN6" SAN6" SAN6" SAN6" SAN6" SANFIRERISER11944WC-1BS-1WB-1L-1WC-1S-12" SAN UP3" SAN UP4423" SAN UP2FS-1FCOTP-13" SAN UPFD-1FCO6" SANFCO4" DCW UP1" IRR UP6BUILDING 2BUILDING 3BUILDING 5BUILDING 4BUILDING 1sheet:title:DCBADCBA1 2 3 4 51 2 3 4 5UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION601 Euclid Ave. Suite CHelena, Montana59601406-531-4745unitedhousingpartners.comUHP Design LLC406-224-8220revisions :p r o j e c t # :d a t e :KEY PLANproject:stampTHE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.m-m.net2880 Technology Blvd W, Bozeman, MT 59718(406) 587-0721P100PLUMBINGUNDERSLABPLAN - LEVEL1100% CD SET2025.11.2625.0275ADDRESS: BOZEMAN, MTHidden CreekBuilding 53/32" = 1'-0"1PLUMBING UNDERSLAB PLAN - LEVEL 1A. PROVIDE ACCESS DOORS TO ALLOW SERVICE AND INSPECTION OF EQUIPMENT, VALVES, AND OTHER DEVICES INSTALLED IN INACCESSIBLE LOCATIONS. COORDINATE SUCH INSTALLATIONS WITH THE ARCHITECT AND ENGINEER.B. PROVIDE TRAP SEALS AND TRAP PRIMERS FOR FLOOR DRAINS, FLOOR SINKS, AND OTHER FLOOR RECEPTORS.C. INSTALL ACCESSIBLE PLUMBING FIXTURES IN COMPLIANCE WITH ADA REQUIREMENTS. INSULATE EXPOSED PIPING BELOW ADA ACCESSIBLE FIXTURES. D. INSTALL FLOOR DRAIN STRAINERS AND CLEANOUT COVERS FLUSH AND LEVEL WITH FINISHED FLOOR.E. PIPING SHALL BE IDENTIFIED WITH PIPE LABELS MARKED AT A MAXIMUM OF EVERY 25 FT. VALVES SHALL BE IDENTIFIED WITH BRASS OR ALUMINUM VALVE TAGS.F. PROVIDE AND INSTALL PIPE GUIDES, EXPANSION JOINTS, AND HANGERS PER MANUFACTURER'S RECOMMENDATIONS.G. PIPING WALL PENETRATIONS SHALL BE FINISHED WITH A CHROME ESCUTCHEON PLATE.H. MAINTAIN THE INTEGRITY OF DRAFTSTOPPING WHERE PIPES PENETRATE DRAFTSTOPPING MATERIALS.I. NO FITTINGS OR PIPING CONNECTIONS SHALL BE INSTALLED UNDERSLAB.J. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES.K. COORDINATE CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.L. EXPOSED PIPING SHALL BE PAINTED PER ARCHITECTURAL OR PROVIDED WITH A PVC COATED JACKET IN THE COLOR OF THE ARCHITECT'S CHOOSING. CONTRACTOR TO CLEAN AND DRY PIPING PRIOR TO PAINTING. M. SANITARY SEWER, RAINWATER, AND OTHER DRAIN PIPING SHALL BE INSTALLED AT A MINIMUM 1/4" PER FOOT (2%) SLOPE IN DIRECTION OF FLOW. UNLESS OTHERWISE INDICATED ON THE DRAWINGS.N. COORDINATE UNDERGROUND FIRE RISER STUB UP LOCATION WITH FIRE SUPPRESSION SHOP DRAWINGS.PLUMBING PLAN NOTESKEY NOTES:#1. REFER TO SITE CIVIL FOR CONTINUATION.2. WET VENTED BATHROOM GROUP. SIZE PIPING AS SHOWN AND CONNECT WATER CLOSET DOWNSTREAM OF LAVATORY. 3. SINK TO BE PENINSULA VENTED.4. ROUTE UNDERSLAB PIPING FROM UPPER FLOORS AT LEAST 8' BEFORE CONNECTING INTO ANY OTHER SANITARY DRAINAGE LINES FOR SUDS RELIEF PER SECTION 711.0 IN THE UNIFORM PLUMBING CODE.5. CONNECT FS-1 SANITARY PIPING INTO ADJACENT UNIT SANITARY PIPING. 6. FIRE LINE SHOWN FOR REFERENCE ONLY. PLUMBING CONTRACTOR IS NOT RESPONSIBLE FOR THIS SCOPE.ISSEFORP LANOENGINEERONTMANALICENSEDDYLAN R.JUNJAKNo. 76054 PE