HomeMy WebLinkAbout052 P303 Building 3 Plumbing DetailsWALL
FLOOR BELOW
UPPER FLOOR
PTAC
ROUTE CONDENSATE DRAIN
TO WASHER BOX ON FLOOR BELOW
1ST FLOOR PTAC
CONDENSATE IS TAKEN
CARE OF AT UNIT (SEE SCHEDULE)
PROVIDE MANUFACTURER'S WALL
SLEEVE/. INSTALL PER MANUFACTURER'S
WINSTRUCTIONS.
WASHING MACHINE WALL BOX.
2" STAND PIPE
CEILING
2' - 0"
FIRE RISER SIZED
BY FIRE SPRINKLER
11' - 0"
2' - 0"4" DCW
P
W
W
P
P2' - 0"1' - 0"1' - 4"1" IRRIGATION
DOUBLE CHECK BACKFLOW PREVENTOR
WATER METER BY UTILITY(TYP.)
STRAINER
REDUCER
2' MAX1' MIN3"∅
ISOLATION VALVE (TYP.)
PRESSURE GUAGE (TYP.)
PRESSURE REDUCING VALVE - SET TO 60 PSI (TYP.)
2" IRRIGATION (BUILDING 3 ONLY)
SEE FLOOR PLANS
FOR CONTINUATION
REDUCED PRESSURE BACKFLOW
PREVENTOR = PIPE AIR GAP TO
FLOOR DRAIN
OS&Y VALVE WITH STEM;
PARALLELTO FLOOR.
4"
3"
SEE FLOOR PLANS
FOR CONTINUATION
BALL VALVE (TYPICAL)
THERMOMETER (TYPICAL)
DIELECTRIC UNION
(TYPICAL)
WALL
R
WH-3
RUN DISCHARGE LINE
TO SERVICE SINK
(SAME SIZE AS VALVE
DISCHARGE)
WATTS RESTRAINT
T&P RELIEF VALVE
ANCHOR WATER HEATER TO
WALL WITH WATTS
SPACEMAKER WM-30
NON-CORROSSIVE METAL DRIP PAN
RUN 3/4" DRAIN LINE TO AN
APPROVED INDIRECT RECEPTOR
THERMAL EXPANSION TANK.
ET-3
SECURE TANK TO WALL.
MOUNT HIGH
ON WALL
RECIRCULATION PUMP RP-1
BALL VALVE (TYP)
CHECK VALVE (TYP)
3/4" COLD WATER
3/4" HOT WATER
3/4" HOT WATER RETURN
NTS1WATER HEATER DETAIL (ELECTRIC WALL HUNG W/ RECIRC)BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1
sheet:
title:
D
C
B
A
D
C
B
A
1 2 3 4 5
1 2 3 4 5
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
601 Euclid Ave. Suite C
Helena, Montana
59601
406-531-4745
unitedhousingpartners.com
UHP Design LLC
406-224-8220
revisions :
p r o j e c t # :
d a t e :
KEY PLAN
project:
stamp
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
PROJECT NO. 24-373
P303
PLUMBING
DETAILS
100% CD SET
11/26/2025
24.0550
Bozeman, MT
Hidden Creek
Building 3
3 City Plan Review Comments 8/08/2025
4 Revision #3 11/26/2025
5 City Comments #2 12/23/2025NTS2PTAC CONDENSATE DRAIN DETAIL
NTS3IRRIGATION WATER LINE DETAIL
5
12/17/2025