HomeMy WebLinkAbout051 P201 Building 2 Plumbing Details2' - 0"
FIRE RISER SIZED
BY FIRE SPRINKLER
11' - 0"
2' - 0"4" DCW
P
W
W
P
P2' - 0"1' - 0"1' - 4"1" IRRIGATION
DOUBLE CHECK BACKFLOW PREVENTOR
WATER METER BY UTILITY(TYP.)
STRAINER
REDUCER
2' MAX1' MIN3"∅
ISOLATION VALVE (TYP.)
PRESSURE GUAGE (TYP.)
PRESSURE REDUCING VALVE - SET TO 60 PSI (TYP.)
1" IRRIGATION (BUILDING 3 ONLY)
SEE FLOOR PLANS
FOR CONTINUATION
REDUCED PRESSURE BACKFLOW
PREVENTOR = PIPE AIR GAP TO
FLOOR DRAIN
OS&Y VALVE WITH STEM;
PARALLELTO FLOOR.
4"
3"
SEE FLOOR PLANS
FOR CONTINUATION
NOTE:
1. CLEANOUTS SHALL BE PROVIDED AT EACH HORIZONTAL DRAINAGE PIPE AT ITS UPPER
TERMINAL, AND EACH RUN OF PIPING WHICH IS MORE THAN 100 FEET, AND SHALL BE
PROVIDED FOR EACH 100 FEET DEVELOPED LENGTH, OR FRACTION THEREOF OF SUCH
PIPING. AN ADDITIONAL CLEANOUT SHALL BE PROVIDED FOR EACH AGGREGATE
HORIZONTAL CHANGE OF DIRECTION EXCEEDING ONE HUNDRED THIRTY-FIVE DEGREES,
PER APPLICABLE PLUMBING CODE. THIS SHALL BE PROVIDED REGARDLESS OF WHAT IS
SHOWN ON THE DRAWINGS.
BALANCE OF PIPING, SEE
SPECIFICATIONS FOR PIPE MATERIAL
1/8 C.I. BEND
FLOOR LINE
CLEANOUT AND ACCESS COVER, TOP OF
COVER TO BE FLUSH WITH TIP OF FLOOR
FINISH GRADE
BRONZE CLEANOUT PLUG WITH COUNTER
SUNK HEAD, SEE THE PLUMBING FIXTURE
SCHEDULE FOR MANUFACTURER AND MODEL
SAME SIZE AND MATERIAL
AS THE SEWER PIPING
CAP AT TERMINUS
SANITARY SEWER LINE (PVC, ASTM D3033 OR
D3034, SDR 35, WITH ELASTOMERIC GASKETS)
FINISH PAVEMENT
SCREW CAP/PLUG ROUND FLANGED HOUSING WITH HEAVY DUTY
CAST IRON COVER, COVER TO BE INSCRIBED
"SAN", SEE THE PLUMBING FIXTURE SCHEDULE
FOR MANUFACTURER AND MODEL
SAME SIZE AND MATERIAL
AS THE SEWER PIPING
CAP AT TERMINUS
SANITARY SEWER LINE (PVC, ASTM D3033 OR
D3034, SDR 35, WITH ELASTOMERIC GASKETS)
SEE PLANS
6"
18"
SEE PLANS
PEDESTRIAN TRAFFIC AREAS / NON-PAVED AREAS
45° ELBOW
45° WYE
45° WYE
45° ELBOW
VEHICULAR TRAFFIC AREAS / PAVED AREAS
NOTES:
A. INTERIOR EXPOSED PIPE, VALVES AND FIXTURE TRIM, INCLUDING TRIM BEHIND CASEWORK DOORS SHALL BE
CHROME PLATED.
B. ALL PIPING PENETRATIONS THROUGH FINISHED WALLS SHALL BE PROVIDED WITH CHROME ESCUTCHEONS.
C. ALL SINK TRAPS SHALL BE PROVIDED WITH A CLEANOUT PLUG IN THE BOTTOM OF THE TRAP.
D. ALL PLUMBING FIXTURES SHALL BE CAULKED AND SEALED TO SURROUNDING SURFACES.
SEE PLUMBING FIXTURE
SCHEDULE FOR BOWL &
FAUCET SPECIFICATIONS
CHROME PLATED
COPPER TUBING
WATER RISERS
OTHER PIPING
MATERIALS, SEE
SPECIFICATIONS
CHROME PLATED PIPING AND
FITTINGS, TYPICAL ALL PIPING
BELOW SINKS AND LAVATORIES,
SEE NOTES BELOW
CLEANOUT PLUG
CHROME ESCUTCHEON
NOTES:
1. MAINTAIN ONE-FOURTH (1/4) INCH PER FOOT SLOPE.
2. THE DEVELOPED LENGTH BETWEEN THE TRAP OF A WATER CLOSET OR SIMILAR FIXTURE (MEASURED FROM THE TOP
OF THE CLOSET FLANGE TO THE INNER EDGE OF THE VENT) AND IT'S VENT SHALL NOT EXCEED SIX (6) FEET.
3. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED
PLUMBING CODE, AND ALL LOCAL AND STATE CODES.
TRAP ARM
TRAP
VENT
FROM
FIXTURE
WASTE
FLOW
VENT
D (DIAMETER)
2'-6" (D=1-1/4")
3'-6" (D=1-1/2")
5' (D=2")
6' (D=3")
10' (D=4" OR MORE)
MAXIMUM
TRAP ARM
DISTANCE
TRAP WEIR
MINIMUM TRAP ARM
DISTANCE 2 X D
7/8" DISHWASHER
DISCHARGE HOSE
TO P-TRAP
DISHWASHER
LOOP HOSE UP HIGH
BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1
sheet:
title:
D
C
B
A
D
C
B
A
1 2 3 4 5
1 2 3 4 5
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
601 Euclid Ave. Suite C
Helena, Montana
59601
406-531-4745
unitedhousingpartners.com
UHP Design LLC
406-224-8220
revisions :
p r o j e c t # :
d a t e :
KEY PLAN
project:
stamp
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
PROJECT NO. 24-373
P201
PLUMBING
DETAILS
100% CD SET
11/26/2025
24.0550
Bozeman, MT
Hidden Creek
Building 2
NTS3FLOOR CLEANOUT (FCO) DETAIL
NTS4GRADE CLEANOUT (GCO) DETAIL
NTS5SINK/LAVATORY TAILPIECE & TRAP DETAIL
NTS6TRAP ARM DETAIL
5 Revision #3 11/26/2025
NTS2DISHWASHER CONNECTION DETAIL
NTS1BUILDING WATER SERVICE DETAIL
5
12/1/2025