Loading...
HomeMy WebLinkAbout043 E000 - Electrical Cover Sheetsheet: title: D C B A D C B A 1 2 3 4 5 1 2 3 4 5 UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION 601 Euclid Ave. Suite C Helena, Montana 59601 406-531-4745 unitedhousingpartners.com UHP Design LLC 406-224-8220 revisions : p r o j e c t # : d a t e : KEY PLAN project: stamp THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. Project No.: 24-373 E000 ELECTRICAL COVER SHEET 03/27/2025 Bozeman, MT Hidden Creek Community G. ALL NON-LOCKING, 120-V, 15 AND 20-AMP RECEPTACLES SHALL BE LISTED TAMPER-RESISTENT RECEPTACLES PER NEC 406.12 H. CONTRACTOR SHALL COORDINATE WITH AN UNDERGROUND LOCATING SERVICE PRIOR TO COMMENCING WORK. SEE CIVIL DRAWINGS FOR ADDITIONAL SITE INFORMATION. COORDINATE WITH OTHER SITE DISCIPLINES. I. SITE LIGHTING AND UTILITY EQUIPMENT SHOWN IN APPROXIMATE LOCATION. COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS, PROPERTY LINES, AND UTILITY COMPANIES PRIOR TO ROUGH-IN. J. REFER TO POLE BASE DETAIL FOR SITE LIGHTING POLE BASE REQUIREMENTS. K. ROUTE CONDUITS IN COMMON TRENCH WHERE POSSIBLE REFER TO TRENCHING DETAIL. EG 100A 3P J ST GFP ELECTRICAL LEGEND - LIGHTING DEVICES ONE LINE A AMPERES AC 6" ABOVE BACKSPLASH AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AF AMP FRAME AIC AMPS INTERRUPTING CAPACITY AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BD BOTTOM OF DECK BS BOTTOM OF STRUCTURE C CEILING MOUNTED C CONDUIT CB CIRCUIT BREAKER CF COMPACT FLUORESCENT CKT CIRCUIT CO CONDUIT ONLY, PROVIDE PULL-LINE CT CURRENT TRANSFORMER CTL CONTROL DC DIRECT CURRENT (D) DEMOLITION DEMO DEMOLITION DET DETAIL DTT DOUBLE TWIN TUBE E EMERGENCY (E)EXISTING EC ELECTRICAL CONTRACTOR EL EMERGENCY LIGHT F FUSE (F)FUTURE FACP FIRE ALARM CONTROL PANEL G/GND GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER HH HAND HOLE HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTO HPS HIGH PRESSURE SODIUM HVAC HEATING, VENTILATION, & AIR CONDITIONING IG ISOLATED GROUND IPCO IDAHO POWER COMPANY J-BOX JUNCTION BOX KA KILOAMP KVA KILO VOLT-AMP KW KILOWATT KWH KILOWATT HOUR LCP LIGHTING CONTROL PANEL MB MAIN BREAKER MBR MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MMC MODULAR METERING CENTER MH METAL HALIDE MSB MAIN SWITCH BOARD MTG MOUNTING N NEUTRAL (N) NEW NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OH OVERHEAD OS OCCUPANCY SENSOR P POLES PC PHOTO-CONTROL PVC POLYVINYL CHLORIDE PWR POWER RE: REFERENCE REC RECEPTACLE (R)RELOCATED SF SQUARE FEET TBD TO BE DETERMINED TDR TIME DELAY RELAY TK TOE KICK TSP TWISTED SHIELDED PAIR TRT TRIPLE TUBE TTB TELEPHONE TERMINAL BOARD (TYP.) TYPICAL UC UNDERCABINET UG UNDERGROUND U.N.O. UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERE W WATT WG WIRE GUARD WP WEATHER PROOF/NEMA 3R ELECTRICAL ABBREVIATIONS PROVIDED/ PROVIDE BY INSTALLED/ INSTALL PROVIDE AND INSTALL / PROVIDED AND INSTALLED BY / PROVIDE AND INSTALL NOTE:THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. CIRCUITING SYMBOLS ELECTRICAL GENERAL NOTES LSIGR S M TVSS HC # # # # # # PANEL NAME VOLTAGE PHASE #P ##A #P ##A ##A ##A #P T ##A #P XXX EMERGENCY SOURCE EXISTING CONDUIT DOWN CONDUIT UP 6 NEUTRAL CONDUCTORS GROUNDING CONDUCTOR SIZE QUANTITY 1"-4#10,1#10G PANEL HOMERUN. (3/4"-2#12,1#12G CONDUCTORS UNO) RACEWAY DESIGNATES CIRCUIT ON A-2,4,6 PANEL NAME CIRCUIT # EM T XXXA/XP N M DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. INDIVIDUAL BREAKER WITH SHUNT TRIP, SIZE AND POLES INDICATED. NEMA 1 UNO INDIVIDUAL BREAKER, SIZE AND POLES INDICATED. NEMA 1 UNO REFERENCE FIXTURE SCHEDULE FOR MOUNTING TYPE, MOUNTING HEIGHT, AND FIXTURE TYPE. DOUBLE FACE EXIT SIGN, CEILING MOUNTED, PROVIDE UNSWITCHED CONDUCTOR. WALL MOUNTED DOUBLE FACE EXIT SIGN PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO. SINGLE FACE EXIT SIGN, CEILING MOUNTED PROVIDE UNSWITCHED CONDUCTOR. WALL MOUNTED SINGLE FACE EXIT SIGN PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO. ARROW INDICATES DIRECTION TO BE SHOWN ON SIGN. 1'X1' LIGHT FIXTURE. 1'X1' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR. 1'X4' LIGHT FIXTURE. 1'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR. 2'X4' LIGHT FIXTURE. 2'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR. 2'X2' LIGHT FIXTURE. 2'X2' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR. DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR STRIP FLUORESCENT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. STRIP FLUORESCENT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR WALL MOUNTED LIGHT FIXTURE. WALL MOUNTED LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR. RECESSED LIGHT FIXTURE RECESSED LIGHT FIXTURE. PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR. ROUND LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE. POLE LIGHT 1 HEAD WITH POLE TIME CLOCK PHOTO CONTROL CELL LOCATED 12" ABOVE ROOF FACING NORTH. EMERGENCY EGRESS LIGHTING. CONNECT TO AN UNSWITCHED CONDUCTOR. INDICATES FIXTURE TYPE. REFER TO FIXTURE SCHEDULE. EXTERIOR WALL PACK EMERGENCY EXTERIOR WALL PACK. PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED CONDUCTOR SWITCH, TYPE AS INDICATED. +46"AFF OCCUPANCY SENSOR. PROVIDE RELAYS AND POWER PACKS AS REQUIRED SINGLE CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT SINGLE CONVENIENCE OUTLET DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT DUPLEX CONVENIENCE OUTLET EMERGENCY DUPLEX CONVENIENCE OUTLET, +18" AFF UNO SWITCHED DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNTED SWITCHED DUPLEX CONVENIENCE OUTLET FOURPLEX CONVENIENCE OUTLET. +18"AFF UNO FLOOR MOUNT FOURPLEX CONVENIENCE OUTLET CONNECTION POINT TO EQUIPMENT SPECIFIED, ELECTRICAL CONTRACTOR TO SUPPLY RACEWAY AND CONDUCTORS AND MAKE FINAL CONNECTION TO EQUIPMENT UNDER THIS SECTION. UNO JUNCTION BOX WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, HANDICAPPED MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO MOTOR STARTER/CONTACTOR, SIZE/POLES NEMA 1 UNO AS INDICATED COMBINATION STARTER AND DISCONNECT, SIZE/POLES, STARTER SIZE AS INDICATED, NEMA 1 UNO MECHANICAL EQUIPMENT CALL OUT SURFACE MULTI-OUTLET RACEWAY EQUIPMENT CABINET FLUSH MOUNTED EQUIPMENT CABINET, SURFACE MOUNTED PANELBOARD. SEE SCHEDULE FOR TYPE. TRANSFORMER POWER POLE - DUAL CHANNEL THERMOSTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS REQUIRED TO CONTROL ASSOCIATED UNITS. UNO COORDINATE WITH DIVISION 15. NON-FUSED DISCONNECT SIZE/ POLES AS INDICATED, NEMA 1 UNO FUSED DISCONNECT SWITCH, SIZE/POLES, FUSE SIZES AS INDICATED, NEMA 1 UNO DELTA WYE TRANSFORMER UNO PANEL BOARD, SEE SCHEDULE FOR TYPE AND SIZE CIRCUIT BREAKER, SIZE AND POLES INDICATED FUSE, SIZE AND TYPE INDICATED, PROVIDE FUSE FOR EACH POLE INTERRUPTER SWITCH, SIZE AND POLES INDICATED FUSED SWITCH, SIZE/POLES AND FUSE SIZE INDICATED DRAW OUT CIRCUIT BREAKER, SIZE AND POLES INDICATED GROUND FAULT PROTECTION TRANSIENT VOLTAGE SURGE SUPPRESSION NEUTRAL METER AND BASE AUTOMATIC TRANSFER SWITCH (ATS) GENERATOR SET, MAIN BREAKER SIZE INDICATED OVERHEAD SERVICE DROP DISCONNECT SWITCH, SIZE AND POLES INDICATED. NEMA 1 UNO MOTOR SHUNT TRIP COIL PAD MOUNT TRANSFORMER TRANSFORMER KITCHEN EQUIPMENT CALLOUT TRACK LIGHT ADJUSTABLE BREAKER SETTINGS (PER SPECIFICATIONS): 'L'-LONG TIME 'S'-SHORT TIME 'I'-INSTANTANEOUS 'G'-GROUND FAULT 'R'-ENERGY REDUCING MAINTENANCE SWITCH W/STATUS INDICATOR EMERGENCY EGRESS LIGHTING WITH OUT FIXTURE HEADS. CONNECT TO AN UNSWITCHED CONDUCTOR. 2 DOUBLE POLE 3 3-WAY 4 4-WAY K KEYED P PILOT LIGHT D DIMMER HP HORSEPOWER RATED TO THERMAL OVERLOAD LV LOW VOLTAGE OS OCCUPANCY SENSOR OR LOW VOLTAGE, MOMENTARY OVERRIDE VS VACANCY SENSOR a SUPERSCRIPT INDICATES LIGHTS TO BE SWITCHED TOGETHER GROUND ROUND EMERGENCY LIGHT FIXTURE WALL MOUNTED EMERGENCY LIGHT FIXTURE. DUAL LEVEL SWITCHING WITH OCCUPANCY SENSOR, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. BEGINNING OF INDIVIDUAL CIRCUIT(S), CIRCUIT NUMBER(S) INDICATED. CONDUIT, STUBBED, CAPPED AND MARKED WITH PULL CORD AS SPECIFIED EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED. EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN INDIVIDUAL DEDICATED NEUTRAL CONDUCTOR. CONCEALED IN FLOOR OR UNDERGROUND NOTE: UNMARKED CIRCUIT IS CONCEALED IN CEILING OR WALL. MAINTAIN CONDUIT AND CONDUCTOR SIZE THROUGHOUT ENTIRE CIRCUIT. CURRENT CARRYING CONDUCTORS LED DRIVER OCCUPANCY SENSOR WITH MANUAL DIMMING, SET FOR 50% AUTOMATIC ON, AUTOMATIC OFF, WITH MANUAL DIMMING. USB DUPLEX CONVENIENCE OUTLET, +18" AFF UNO A. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE, THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR. B. ALL CONDUIT AND JUNCTION BOXES ARE TO BE CONCEALED UNLESS LOCATED WITHIN DEDICATED ELECTRICAL OR MECHANICAL ROOMS. USE OF SURFACE MOUNTED RACEWAYS IN ALL OTHER SPACES MUST BE APPROVED BY THE ARCHITECT FOR EACH LOCATION. WHERE SURFACE RACEWAYS ARE APPROVED, UTILIZE WIREMOLD, OR APPROVED EQUAL, SURFACE MOUNTED RACEWAYS PAINTED TO MATCH SURROUNDING WALLS. C. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET HEIGHTS WHERE THE SPECIFIC OUTLET HEIGHT IS NOT INDICATED. REFER TO THE ELECTRICAL LEGEND FOR THE DEFAULT OUTLET HEIGHT WHEN NOT INDICATED ON ELEVATIONS OR ON AT THE DEVICES. D. PROVIDE PULL-LINE IN ALL EMPTY CONDUITS. E. TERMINATE ALL LOW-VOLTAGE CONDUITS WITH INSULATED THROAT BUSHING. F. MECHANICAL EQUIPMENT INDICATED IS SHOWN IN AN APPROXIMATE LOCATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. JJ JJJ J J OSDS OS PC TC D SOS2 S S X-X T F XXS 1 City Comments 07/16/2025 2 City Comments 12/22/2025 2 12/22/2025Ethan Hardy 12/22/2025