HomeMy WebLinkAbout043 E000 - Electrical Cover Sheetsheet:
title:
D
C
B
A
D
C
B
A
1 2 3 4 5
1 2 3 4 5
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
601 Euclid Ave. Suite C
Helena, Montana
59601
406-531-4745
unitedhousingpartners.com
UHP Design LLC
406-224-8220
revisions :
p r o j e c t # :
d a t e :
KEY PLAN
project:
stamp
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
Project No.: 24-373
E000
ELECTRICAL
COVER
SHEET
03/27/2025
Bozeman, MT
Hidden Creek
Community
G. ALL NON-LOCKING, 120-V, 15 AND 20-AMP RECEPTACLES SHALL BE LISTED
TAMPER-RESISTENT RECEPTACLES PER NEC 406.12
H. CONTRACTOR SHALL COORDINATE WITH AN UNDERGROUND
LOCATING SERVICE PRIOR TO COMMENCING WORK. SEE CIVIL
DRAWINGS FOR ADDITIONAL SITE INFORMATION. COORDINATE
WITH OTHER SITE DISCIPLINES.
I. SITE LIGHTING AND UTILITY EQUIPMENT SHOWN IN
APPROXIMATE LOCATION. COORDINATE EXACT LOCATION WITH
CIVIL DRAWINGS, PROPERTY LINES, AND UTILITY COMPANIES
PRIOR TO ROUGH-IN.
J. REFER TO POLE BASE DETAIL FOR SITE LIGHTING POLE BASE
REQUIREMENTS.
K. ROUTE CONDUITS IN COMMON TRENCH WHERE POSSIBLE
REFER TO TRENCHING DETAIL.
EG
100A
3P
J
ST
GFP
ELECTRICAL LEGEND - LIGHTING DEVICES ONE LINE
A AMPERES
AC 6" ABOVE BACKSPLASH
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AF AMP FRAME
AIC AMPS INTERRUPTING CAPACITY
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
BD BOTTOM OF DECK
BS BOTTOM OF STRUCTURE
C CEILING MOUNTED
C CONDUIT
CB CIRCUIT BREAKER
CF COMPACT FLUORESCENT
CKT CIRCUIT
CO CONDUIT ONLY, PROVIDE PULL-LINE
CT CURRENT TRANSFORMER
CTL CONTROL
DC DIRECT CURRENT
(D) DEMOLITION
DEMO DEMOLITION
DET DETAIL
DTT DOUBLE TWIN TUBE
E EMERGENCY
(E)EXISTING
EC ELECTRICAL CONTRACTOR
EL EMERGENCY LIGHT
F FUSE
(F)FUTURE
FACP FIRE ALARM CONTROL PANEL
G/GND GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFI GROUND FAULT INTERRUPTER
HH HAND HOLE
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTO
HPS HIGH PRESSURE SODIUM
HVAC HEATING, VENTILATION, & AIR CONDITIONING
IG ISOLATED GROUND
IPCO IDAHO POWER COMPANY
J-BOX JUNCTION BOX
KA KILOAMP
KVA KILO VOLT-AMP
KW KILOWATT
KWH KILOWATT HOUR
LCP LIGHTING CONTROL PANEL
MB MAIN BREAKER
MBR MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MLO MAIN LUGS ONLY
MMC MODULAR METERING CENTER
MH METAL HALIDE
MSB MAIN SWITCH BOARD
MTG MOUNTING
N NEUTRAL
(N) NEW
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
OH OVERHEAD
OS OCCUPANCY SENSOR
P POLES
PC PHOTO-CONTROL
PVC POLYVINYL CHLORIDE
PWR POWER
RE: REFERENCE
REC RECEPTACLE
(R)RELOCATED
SF SQUARE FEET
TBD TO BE DETERMINED
TDR TIME DELAY RELAY
TK TOE KICK
TSP TWISTED SHIELDED PAIR
TRT TRIPLE TUBE
TTB TELEPHONE TERMINAL BOARD
(TYP.) TYPICAL
UC UNDERCABINET
UG UNDERGROUND
U.N.O. UNLESS NOTED OTHERWISE
V VOLT
VA VOLT-AMPERE
W WATT
WG WIRE GUARD
WP WEATHER PROOF/NEMA 3R
ELECTRICAL ABBREVIATIONS
PROVIDED/
PROVIDE BY
INSTALLED/
INSTALL
PROVIDE AND INSTALL / PROVIDED
AND
INSTALLED BY / PROVIDE AND INSTALL
NOTE:THIS IS A STANDARD LIST OF COMMONLY
USED
ELECTRICAL ABBREVIATIONS. SOME OF THE
ABBREVIATIONS SHOWN ABOVE MAY NOT BE
USED IN THIS DRAWING PACKAGE.
CIRCUITING SYMBOLS
ELECTRICAL GENERAL NOTES
LSIGR
S
M
TVSS
HC
#
#
#
#
#
#
PANEL
NAME
VOLTAGE
PHASE
#P
##A
#P
##A
##A
##A
#P
T
##A
#P
XXX
EMERGENCY SOURCE
EXISTING
CONDUIT DOWN CONDUIT UP
6
NEUTRAL CONDUCTORS
GROUNDING CONDUCTOR
SIZE
QUANTITY
1"-4#10,1#10G
PANEL HOMERUN. (3/4"-2#12,1#12G CONDUCTORS UNO)
RACEWAY
DESIGNATES CIRCUIT ON
A-2,4,6
PANEL NAME
CIRCUIT #
EM
T
XXXA/XP
N
M
DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF FIXTURE
TO BE SWITCHED SEPARATELY.
INDIVIDUAL BREAKER WITH SHUNT TRIP, SIZE AND POLES
INDICATED. NEMA 1 UNO
INDIVIDUAL BREAKER, SIZE AND POLES INDICATED. NEMA 1 UNO
REFERENCE FIXTURE SCHEDULE FOR MOUNTING TYPE, MOUNTING HEIGHT,
AND FIXTURE TYPE.
DOUBLE FACE EXIT SIGN, CEILING MOUNTED, PROVIDE UNSWITCHED
CONDUCTOR.
WALL MOUNTED DOUBLE FACE EXIT SIGN PROVIDE UNSWITCHED
CONDUCTOR. MOUNT AT +8'-0" UNO.
SINGLE FACE EXIT SIGN, CEILING MOUNTED PROVIDE UNSWITCHED
CONDUCTOR.
WALL MOUNTED SINGLE FACE EXIT SIGN PROVIDE UNSWITCHED
CONDUCTOR. MOUNT AT +8'-0" UNO.
ARROW INDICATES DIRECTION TO BE SHOWN ON SIGN.
1'X1' LIGHT FIXTURE.
1'X1' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO
AN UNSWITCHED CONDUCTOR.
1'X4' LIGHT FIXTURE.
1'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO
AN UNSWITCHED CONDUCTOR.
2'X4' LIGHT FIXTURE.
2'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO
AN UNSWITCHED CONDUCTOR.
2'X2' LIGHT FIXTURE.
2'X2' LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST CONNECTED TO
AN UNSWITCHED CONDUCTOR.
DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH.
DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH.
PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED
CONDUCTOR
STRIP FLUORESCENT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH.
STRIP FLUORESCENT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH.
PROVIDE EMERGENCY BALLAST CONNECTED TO AN UNSWITCHED
CONDUCTOR
WALL MOUNTED LIGHT FIXTURE.
WALL MOUNTED LIGHT FIXTURE, PROVIDE EMERGENCY BALLAST
CONNECTED TO AN UNSWITCHED CONDUCTOR.
RECESSED LIGHT FIXTURE
RECESSED LIGHT FIXTURE. PROVIDE EMERGENCY BALLAST
CONNECTED TO AN UNSWITCHED CONDUCTOR.
ROUND LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE.
POLE LIGHT 1 HEAD WITH POLE
TIME CLOCK
PHOTO CONTROL CELL LOCATED 12" ABOVE ROOF FACING NORTH.
EMERGENCY EGRESS LIGHTING. CONNECT TO AN UNSWITCHED
CONDUCTOR.
INDICATES FIXTURE TYPE. REFER TO FIXTURE SCHEDULE.
EXTERIOR WALL PACK
EMERGENCY EXTERIOR WALL PACK. PROVIDE EMERGENCY BALLAST
CONNECTED TO AN UNSWITCHED CONDUCTOR
SWITCH, TYPE AS INDICATED. +46"AFF
OCCUPANCY SENSOR. PROVIDE RELAYS AND POWER PACKS AS
REQUIRED
SINGLE CONVENIENCE OUTLET, +18" AFF UNO
FLOOR MOUNT SINGLE CONVENIENCE OUTLET
DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
FLOOR MOUNT DUPLEX CONVENIENCE OUTLET
EMERGENCY DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
SWITCHED DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
FLOOR MOUNTED SWITCHED DUPLEX CONVENIENCE OUTLET
FOURPLEX CONVENIENCE OUTLET. +18"AFF UNO
FLOOR MOUNT FOURPLEX CONVENIENCE OUTLET
CONNECTION POINT TO EQUIPMENT SPECIFIED, ELECTRICAL
CONTRACTOR TO SUPPLY RACEWAY AND CONDUCTORS AND MAKE
FINAL CONNECTION TO EQUIPMENT UNDER THIS SECTION. UNO
JUNCTION BOX
WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO
WALL MOUNTED PUSH BUTTON, HANDICAPPED MOUNT AT SWITCH
HEIGHT UNO
WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO
MOTOR STARTER/CONTACTOR, SIZE/POLES NEMA 1 UNO AS INDICATED
COMBINATION STARTER AND DISCONNECT, SIZE/POLES, STARTER SIZE
AS INDICATED, NEMA 1 UNO
MECHANICAL EQUIPMENT CALL OUT
SURFACE MULTI-OUTLET RACEWAY
EQUIPMENT CABINET FLUSH MOUNTED
EQUIPMENT CABINET, SURFACE MOUNTED
PANELBOARD. SEE SCHEDULE FOR TYPE.
TRANSFORMER
POWER POLE - DUAL CHANNEL
THERMOSTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS
REQUIRED TO CONTROL ASSOCIATED UNITS. UNO COORDINATE WITH
DIVISION 15.
NON-FUSED DISCONNECT SIZE/ POLES AS INDICATED, NEMA 1 UNO
FUSED DISCONNECT SWITCH, SIZE/POLES, FUSE SIZES AS INDICATED,
NEMA 1 UNO
DELTA WYE TRANSFORMER UNO
PANEL BOARD, SEE SCHEDULE FOR TYPE AND SIZE
CIRCUIT BREAKER, SIZE AND POLES INDICATED
FUSE, SIZE AND TYPE INDICATED, PROVIDE FUSE FOR EACH POLE
INTERRUPTER SWITCH, SIZE AND POLES INDICATED
FUSED SWITCH, SIZE/POLES AND FUSE SIZE INDICATED
DRAW OUT CIRCUIT BREAKER, SIZE AND POLES INDICATED
GROUND FAULT PROTECTION
TRANSIENT VOLTAGE SURGE SUPPRESSION
NEUTRAL
METER AND BASE
AUTOMATIC TRANSFER SWITCH (ATS)
GENERATOR SET, MAIN BREAKER SIZE INDICATED
OVERHEAD SERVICE DROP
DISCONNECT SWITCH, SIZE AND POLES INDICATED. NEMA 1 UNO
MOTOR
SHUNT TRIP COIL
PAD MOUNT TRANSFORMER
TRANSFORMER
KITCHEN EQUIPMENT CALLOUT
TRACK LIGHT
ADJUSTABLE BREAKER SETTINGS
(PER SPECIFICATIONS):
'L'-LONG TIME
'S'-SHORT TIME
'I'-INSTANTANEOUS
'G'-GROUND FAULT
'R'-ENERGY REDUCING MAINTENANCE SWITCH W/STATUS INDICATOR
EMERGENCY EGRESS LIGHTING WITH OUT FIXTURE HEADS. CONNECT
TO AN UNSWITCHED CONDUCTOR.
2 DOUBLE POLE
3 3-WAY
4 4-WAY
K KEYED
P PILOT LIGHT
D DIMMER
HP HORSEPOWER RATED
TO THERMAL OVERLOAD
LV LOW VOLTAGE
OS OCCUPANCY SENSOR
OR LOW VOLTAGE, MOMENTARY OVERRIDE
VS VACANCY SENSOR
a SUPERSCRIPT INDICATES LIGHTS
TO BE SWITCHED TOGETHER
GROUND
ROUND EMERGENCY LIGHT FIXTURE
WALL MOUNTED EMERGENCY LIGHT FIXTURE.
DUAL LEVEL SWITCHING WITH OCCUPANCY SENSOR, INSIDE AND
OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY.
BEGINNING OF INDIVIDUAL
CIRCUIT(S), CIRCUIT NUMBER(S)
INDICATED.
CONDUIT, STUBBED, CAPPED AND MARKED
WITH PULL CORD AS SPECIFIED
EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED.
EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN INDIVIDUAL
DEDICATED NEUTRAL CONDUCTOR.
CONCEALED IN
FLOOR OR
UNDERGROUND NOTE:
UNMARKED CIRCUIT
IS CONCEALED IN CEILING OR WALL.
MAINTAIN CONDUIT AND CONDUCTOR
SIZE THROUGHOUT ENTIRE CIRCUIT.
CURRENT CARRYING
CONDUCTORS
LED DRIVER
OCCUPANCY SENSOR WITH MANUAL DIMMING, SET FOR 50%
AUTOMATIC ON, AUTOMATIC OFF, WITH MANUAL DIMMING.
USB DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
A. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE,
THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL
EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL,
AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE
WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR
ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR.
B. ALL CONDUIT AND JUNCTION BOXES ARE TO BE CONCEALED UNLESS LOCATED
WITHIN DEDICATED ELECTRICAL OR MECHANICAL ROOMS. USE OF SURFACE
MOUNTED RACEWAYS IN ALL OTHER SPACES MUST BE APPROVED BY THE
ARCHITECT FOR EACH LOCATION. WHERE SURFACE RACEWAYS ARE
APPROVED, UTILIZE WIREMOLD, OR APPROVED EQUAL, SURFACE MOUNTED
RACEWAYS PAINTED TO MATCH SURROUNDING WALLS.
C. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET HEIGHTS WHERE THE
SPECIFIC OUTLET HEIGHT IS NOT INDICATED. REFER TO THE ELECTRICAL
LEGEND FOR THE DEFAULT OUTLET HEIGHT WHEN NOT INDICATED ON
ELEVATIONS OR ON AT THE DEVICES.
D. PROVIDE PULL-LINE IN ALL EMPTY CONDUITS.
E. TERMINATE ALL LOW-VOLTAGE CONDUITS WITH INSULATED THROAT BUSHING.
F. MECHANICAL EQUIPMENT INDICATED IS SHOWN IN AN APPROXIMATE
LOCATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR
PRIOR TO ROUGH-IN.
JJ
JJJ
J
J
OSDS
OS
PC
TC
D
SOS2
S S
X-X
T
F
XXS
1 City Comments 07/16/2025
2 City Comments 12/22/2025
2
12/22/2025Ethan Hardy
12/22/2025