HomeMy WebLinkAbout042.1 L5.1 - Irrigation Details 2Civil Engineering Professionals, Inc.6080 Enterprise Drive. Casper, Wy 82609Phone 307.266.4346 Fax 307.266.0103www.cepi-casper.comC:\Users\K
a
l
i
n
aV
a
n
d
e
rP
o
e
l
\
O
ne
D
r
i
v
e
-
U
n
i
t
ed
H
o
u
si
n
g
P
a
rt
n
e
r
s
\
Pr
o
j
e
c
t
s
\M
o
n
t
an
a
\
B
o
ze
m
a
n
-
H
C
\
D
es
i
g
n
\
UH
P
-
M
e
th
o
d
2
4
x3
6
-
O
r
i
gi
n
a
l
L
o
go
_
l
o
g
oo
n
l
y
-
2
51
0
6
0
3
.p
n
gsheet:title:DCBADCBA1234512345UNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARYAND IS NOT INTENDED FOR CONSTRUCTION,RECORDING PURPOSES, OR IMPLEMENTATION545 Blaine StreetMissoula, Montana59801406-531-4745unitedhousingpartners.comUHP Design LLC406-224-8220revisions :p r o j e c t # :d a t e :FEBRUARY 04, 202624-023KEY PLANBUILDING 2
BUILDING 3BUILDING 1BUILDING 4BUILDING 5LOT 1 HIDDEN CREEK MINORHIDDENCREEKAPARTMENTSproject:BUILDING 2
BUILDING 3BUILDING 1BUILDING 4BUILDING 5BUILDING 2
BUILDING 3BUILDING 1BUILDING 4BUILDING 5BUILDING 2
BUILDING 3BUILDING 1BUILDING 4BUILDING 5BUILDING 2
BUILDING 3BUILDING 1BUILDING 4BUILDING 5stampTHE DESIGNS SHOWN AND DESCRIBED HEREININCLUDING ALL TECHNICAL DRAWINGS, GRAPHICREPRESENTATIONS & MODELS THEREOF, AREPROPRIETARY & CAN NOT BE COPIED, DUPLICATED, ORCOMMERCIALLY EXPLOITED IN WHOLE OR IN PARTWITHOUT THE SOLE AND EXPRESS WRITTENPERMISSION FROM METHOD STUDIO INC.Date: 2/4/2026PERFORMANCElandscape design path:RC#2L5.1IRRIGATIONDETAILS 2ICZ-151-40 DRIP CONTROL KIT WITH UNIONSNOT TO SCALE1SUPER JUMBO VALVE BOX12FINISH GRADE23DRIP ZONE KITMODEL ICZ-151-40 WITH FILTER (TIP45 DEGREES) REGULATOR 40 PSI34WATERPROOF CONNECTORS (2)4518-24" COILED WIRE56SCH 80 T.O.E. NIPPLE67MAIN LINE PIPE & FITTINGS78BRICK SUPPORTS (7)893/4" MINUS WASHED GRAVEL910LATERAL PIPE AND FITTINGS1011PVC SLIP UNIONS (2)1116361176111FX-IR-HUNT-DRIP-19NOT TO SCALEDRIP EMITTER AT 1/4" TUBINGSINGLE-OUTLET EMITTER.1/2" POLY DRIP TUBING.EMITTER.TIE-DOWN STAKE AT TOP OF MULCH ELEVATION.1/4" DISTRIBUTION TUBING.1/4" TUBING STAKE.DIFFUSER BUG CAP.2328413.13-03NOT TO SCALEDRIP FLUSH VALVE10" DIAMETER VALVE BOX.COIL 24" TO 30" OF DRIP TUBING IN THEBOX.34" PVC BALL VALVE WITHSHORT NIPPLE.12" DRIP TUBING.2"SET VALVE BOX 2" ABOVEFINISHED GRADE OF SHRUBAREA.6" THICK LAYER OF 34" WASHEDGRAVEL. THE BOX SHALL RESTUPON THE ROCK BED. DO NOTEXTEND GRAVEL INTO BOX.12" DRIP TUBING TO 34" FPT ADAPTER.POP-UP SPRAY HEAD WITHCLOSED NOZZLE, PURPLECOVER AND SWING PIPE.(ZONE OPERATIONALINDICATOR).3328413.49-03NOTE:INSTALL FLUSH VALVE AT THE END OFEVERY BRANCH OF DRIP LINE.PVC MAINLINE.CENTER FEED EXAMPLEEND FEED EXAMPLETYPICAL OFFSET2" FROMHARDSCAPE, 4"FROM PLANTEDAREA.TYPICAL OFFSET 2" FROMHARDSCAPE, 4" FROMPLANTED AREA.TECHLINE CV MAXIMUM LENGTH OF SINGLE LATERAL (FEET)TECHLINE FLOW PER 100 FEETTECHLINE CV GENERAL GUIDELINES FOR WATERING TIMETYPICAL TECHLINE TUBINGLATERALS WITH EMITTERSPACING AS NOTED.STAPLE (TLS6) AT ALL TEES,ELLS, AND AT 5' O.C. ATCLAY, 4' O.C. AT LOAM, OR 3'O.C. AT SAND.POLYETHYLENE OR PVCSUPPLY HEADER, SIZE AS PERHEADER SIZING CHART.MANUAL LINE FLUSHINGVALVE PLUMBED TOEXHAUST HEADER, AS FARFROM THE SUPPLY HEADERAS POSSIBLE.FLUSHING VALVE ATEACH EXHAUST END.MAXIMUM LENGTH OF SINGLELATERAL, SEE CHART.TYPICAL VALVE, FILTER,PRESSURE REGULATOR.MAXIMUM LENGTH OF SINGLELATERAL, SEE CHART.STEP 1: ADD LENGTH OF ALL TECHLINE LATERAL TUBING CONNECTED TO THE HEADER.STEP 2: DIVIDE THIS TOTAL LENGTH BY 100 TO INDICATE THE LENGHT IN UNITS OF 100.STEP 3: LOCATE THE GPM THAT APPLIES FOR EACH UNIT OF 100 FEET LENGTH ON THE CHART"TECHLINE FLOW PER 100 FEET". MULTIPLY THIS GPM NUMBER TIMES THE UNITS OF 100FEET FOR THE TOTAL GPM AT THIS HEADER.STEP 4: SIZE THE HEADER WITH THE FOLLOWING:1 TO 6 GPM: 3/4" HEADER.6 TO 10 GPM: 1" HEADER.10 TO 20 GPM:1 1/4" HEADER.20 TO 30 GPM: 1 1/2" HEADER.SUPPLY AND EXHAUST HEADER SIZING CHART (UNLESS NOTED ON PLANS)TYPICAL NETAFIM TECHLINE CV REQUIREMENTSN.T.S.LAYOUTISLANDODD CURVESIRREGULAR BRANCHING OUT LATERALSJOINING LATERALSSUPPLYHEADEREXHAUSTHEADERCHECK LONGESTLATERAL AGAINSTCHART FOR MAX.LENGTH OF SINGLELATERALTOTAL THE COMBINED LENGTHOF THESE LATERALS ANDCOMPARE TO THE CHART FORMAX. LENGTH OF SINGLELATERAL.AREAS: TRIANGULARIRREGULAR SLOPE FEED LAYOUTMANUAL LINE FLUSHING VALVE.TECHLINE CV LATERAL TUBING.LATERALS PARALLEL TO THECONTOURS OF THE SLOPE.PVC EXHAUST HEADER.TOE OFSLOPE.TOP OF SLOPE.PVC SUPPLYHEADER.REMOTE CONTROLVALVE ASSEMBLY.54" MAXIMUM ELEV.CHANGE WITHOUT CHECKVALVE. IF GREATER,INSTALL INLINE CHECKVALVES EVERY 54" IN ELEV.CHANGE.BOTTOM 1/3 OF SLOPE:CONVENTIONAL SPACING PLUS25%.TOP 2/3 OF SLOPE:CONVENTIONALSPACING.TOTAL LENGTH OF TECHLINE TUBINGIN THIS AREA CAN NOT EXCEED THEMAX. LENGTH OF RUN.TYPICAL START CONNECTIONON EXHAUST HEADER.TYPICAL START CONNECTION ONSUPPLY HEADER.SEESUB-HEADERDETAIL.TYPICAL TECHLINE STARTCONNECTION.PARKING ISLAND TYPICAL LAYOUTMANUAL LINEFLUSHING VALVEPLUMBED TO PVCOR POLYHEADER.WATER SOURCE:DRIP VALVE ORLATERAL FROMVALVE.TYPICAL SUPPLYPIPE.TYPICAL TECHLINEDRIPPER LINETUBING.TYPICAL PVC ORPOLY SUPPLY OREXHAUST HEADER.4328413.56-04Techline® CV STARTCONNECTION (TYP)Techline® CV DRIPLINEFINISH GRADENOTE:1.SEE PLANS AND LEGEND FOR ALL DIMENSIONS AND Techline® CV DRIPLINE SPACING.2.RATIO OF Techline® CV DRIPLINES TO START CONNECTIONS IS SHOWN AT 2:1, BUT MAY VARY PERHYDRAULIC DEMAND ON START CONNECTIONS. SEE PLANS AND LEGEND.COMPACTED SUBGRADEPVC HEADERTechline® CV TEE (TYP)NETAFIM TECHLINE CV SUBHEADER INSTALLATIONNOT TO SCALE5328413.56-84MFMFMFTREE TRUNKREMOTE CONTROL VALVEWITH DISC FILTER AND PRVTechline® CV DRIPLINE.FLOW, DRIPPER SPACING,LINE SPACING PER NETAFIMINSTALLATION GUIDELINES17mm BLANK DRIPLINESUPPLY HEADERMODEL: TLCVOEXHAUST HEADERMANUAL FLUSH VALVE (TYP)MODEL: TLSOVNOTES TO DESIGNER:1.SEE Techline® CV TREE RING DOUBLE OR TRIPLE FOR DETAIL OF EACH SET OF RINGS.2.FOR TOTAL SYSTEM FLOW GREATER THAN 5 GPM USE PVC TO CONNECT TREE RINGS, DOUBLE ORTRIPLE, AND SIZE PVC APPROPRIATELY.SQUARE CONFIGURATION18"Techline® CV SPACING PER NETAFIMINSTALATION GUIDELINESNETAFIM TECHLINE CV MULTIPLE TREE RING LAYOUT - BNTS6328413.56-86