HomeMy WebLinkAbout033.2 A406 - Enlarged Amenity ElevationsGENERAL NOTES - ENLARGED PLANS & ELEVATIONS A. B. C. D. E. F. G. H. SEE G001 FOR GENERAL NOTES ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE ALL ELECTRICAL OUTLETS ABOVE COUNTER TOPS SHOULD BE HORIZONTALLY ALIGNED AND MOUNTED HORIZONTALLY. SEE A1/A581 FOR MAX ALLOWABLE HEIGHT AT TYPE A. PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES & WASTE LINES COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. PROVIDE 4" BACKSPLASH IN THE SAME MATERIAL AS COUNTERTOP. SEE SHEET SERIES G000 FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT SEE A711 FOR FINISH, APPLIANCE AND ACCESSORY SCHEDULE SEE SHEET SERIES A500 FOR WALL & ASSEMBLY TYPES H. I. J. K. L. M. N. O. P. Q. SEE SHEET SERIES A600 FOR DOOR & WINDOW TYPES SEE SHEET SERIES A500 FOR CASEWORK DETAILS SEE SHEET G000 FOR UNIT ACCESSIBILITY REQUIREMENTS ALL RESIDENTIAL UNIT FURNITURE IS OWNER-PROVIDED, OWNER-INSTALLED SEE SHEET A581 FOR CLOSET SHELVING LAYOUTS SEE ACCESSIBILITY GENERAL SHEETS FOR REQUIRED BLOCKING IN TYPE A AND B UNITS UPPER, LOWER, AND TALL MILLWORK CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYPICAL ATTIC ACCESS PANELS WILL BE LOCATED IN SOME UNITS ON LEVEL 3, REFER TO LEVEL 3 RCP FOR FINAL LOCATIONS WALL AND CEILING FINISH TEXTURES TO BE LIGHT KNOCK DOWN "SANTA FE" A4 A516 115 EQ EQ C4 A516 B4 A584 120M ST-01 11.19 PNT-02 1' - 10"2' - 8 1/2"11.20 FILLER 8' - 6" END PANEL 1" OVERHANG A3 A516 WD-012"1'-6"2"2'-2 1/4"2'-6"09.01 TL-03 115 B4 A584 A4 A516 WB-01 120M ST-01 PNT-02 TL-03 2"1'-6"2"2'-2 1/4"2'-6"WD-01 09.01 11.19 11.20 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. SEE ENLARGED FLOOR PLANS FOR INTERIOR ELEVATIONS ALL MATERIALS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS FLOORING MATERIAL TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR THRESHOLDS, UNLESS NOTED OTHERWISE. SEE A584 FOR TRANSITION DETAILS. PREPARE FLOORS/WALLS TO RECEIVE FINISH MATERIAL. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. NOTIFY ARCHITECT IF CONDITIONS ARE INADEQUATE FOR REQUIRED INSTALLATION REFER TO ROOM FINISH LEGEND ON SHEET SERIES A400 FOR MORE INFORMATION SEE DIMENSION PLAN SHEET SERIES A120 FOR WALL TYPE LOCATIONS; SEE SHEET SERIES A500 FOR WALL TYPE AND ASSEMBLY DESCRIPTIONS CONTRACTOR TO PROVIDE SOLID BLOCKING AT ALL CASEWORK, FIXED FURNISHINGS, TOILETS, TUBS, SHOWERS AND EQUIPMENT. COORDINATE WITH ENLARGED PLANS, ELEVATIONS, SECTIONS, FURNITURE, FIXTURE SHEETS, AND SPECIFICATIONS SEE SHEET SERIES A500 FOR TYPICAL DETAILS TILE INSTALLER TO FOLLOW TCNA & ANSI GUIDELINES ALL FLOORING MATERIALS ARE TO RUN WALL TO WALL AND BENEATH CASEWORK VERIFY LOCATION OF POINT OR ORIGIN OF TILE AND CONTROL JOINTS ON SHOP DRAWINGS AND WITH ARCHITECT ON-SITE PRIOR TO INSTALLATION ALL GROUT TO BE SEALED GENERAL CONTRACTOR TO COORDINATE POWER/DATA PLACEMENT FOR FF&E ITEMS WITH ARCHITECT TILE PATTERN TO BE LAID AS SHOWN ON FINISH PLANS PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS AND ALL OUTSIDE EDGES ON TILE WALLS; PROVIDE ALUMINUM EDGE MOULDING @ ALL TILE TO H.M. DOOR TRANSITIONS; SEE FINISH SCHEDULE + TRANSITION SCHEDULE + INTERIOR DETAILS ALL FLOORING TRANSITIONS TO HAVE TRANSITION STRIP. SEE TRANSITION SCHEDULE ON A711 COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. PROVIDE 4" BACKSPLASH. GENERAL NOTES - FINISH4'-0"4"6" 09.01 WB-02 FRP-01 22.34 22.24 22.35 TS-05 4'-0"6" 22.24 22.34 22.35 FRP-01 09.01 WB-02 TS-05 FILLER 2'-3"1'-0"2'-3"2'-9"2'-0"2'-9" FILLER 230M212212 12.0711.1711.06 SF722.32 120M4"2"A4 A584 2124"23.12 06.25 PNT-02 ST-01 WB-01 09.01 115.2 09.01 CASEWORK TAG 101M MODIFIED CASEWORK TYPE AWS STANDARD CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES DIMENSIONS OF CASEWORK OUTLINED ON ELEVATIONS AND IN CASEWORK DETAILS BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1 3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2 sheet: title: D C B A D C B A 123 4 5 123 4 5 UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION 601 Euclid Ave. Suite CHelena, Montana59601 406-531-4745 unitedhousingpartners.com UHP Design LLC 406-224-8220 revisions : p r o j e c t # : d a t e : KEY PLAN project: stamp THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. A406 ENLARGED AMENITY ELEVATIONS SITE PLAN RC2 12.23.2025 24.0550 ADDRESSBozeman, MT Hidden Creek Building 3 KEYED NOTES 06.25 WOOD COLUMN, SEE STRUCTURAL 09.01 PAINTED GYP. PNT-1; RE: FINISH SCHEDULE 11.06 MICROWAVE (COUNTERTOP); RE: APPLIANCE SCHEDULE 11.17 UNDERCOUNTER ADA FRIDGE, SEE APPLIANCE SCHEDULE, AE601. 11.19 ELECTRIC FIREPLACE INSERT, TWO SIDED; RE: APPLIANCE SCHEDULE 11.20 WALL MOUNTED TV; ; OWNER PROVIDED, CONTRACTOR INSTALLED. PROVIDE BLOCKING FOR MOUNTING BRACKETS; POSITIONRECESSED POWER & INPUT RECEPTICLE CENTERED ON TV. 12.07 LOWER CABINETS, RE: FINISH SCHEDULE AND MILLWORK DETAILS 22.24 MOP SINK, RE: PLUMBING 22.32 KITCHEN FAUCET; SEE PLUMBING 22.34 WALL FAUCET, RE: PLUMBING 22.35 MOP HOOK, RE: PLUMBING 23.12 VENTED ACCESS PANEL, RE: MECHANICAL FRP-01 FIBER-GLASS REINFORCED PANEL, FRP-01; RE: FINISH SCHEDULE PNT-02 UNIT CASEWORK PAINT, PNT-02; RE: FINISH SCHEDULE ST-01 QUARTZ COUNTERTOP AND BACKSPLASH, RE: FINISH SCHEDULE TL-03 WALL TILE, TL-03; RE: FINISH SCHEDULE TS-05 FRP CAP MOULDING, TS-06; RE: FINISH SCHEDULE WB-01 WALL BASE, WB-01, RE: FINISH SCHEDULE WB-02 COMPOSITE WALL BASE, WB-02; RE: FINISH SCHEDULE WD-01 SOLID HARDWOOD, WD-01; RE: FINISH SCHEDULE 1/4" = 1'-0"A3COMMUNITY ROOM 1 1/4" = 1'-0"B3LEASING OFFICE 1 1/4" = 1'-0"D4 MAINTENANCE SINK - 1 1/4" = 1'-0"D3MAINTENANCE SINK - 2 1/4" = 1'-0"A2COMMUNITY ROOM 2 1/4" = 1'-0"B2LEASING OFFICE 2 5 Revision 2 10.10.25