HomeMy WebLinkAbout033.2 A406 - Enlarged Amenity ElevationsGENERAL NOTES - ENLARGED PLANS & ELEVATIONS
A.
B.
C.
D.
E.
F.
G.
H.
SEE G001 FOR GENERAL NOTES
ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE
ALL ELECTRICAL OUTLETS ABOVE COUNTER TOPS SHOULD BE HORIZONTALLY ALIGNED AND MOUNTED HORIZONTALLY. SEE A1/A581 FOR MAX ALLOWABLE HEIGHT AT TYPE A.
PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES & WASTE LINES
COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. PROVIDE 4" BACKSPLASH IN THE SAME MATERIAL AS COUNTERTOP.
SEE SHEET SERIES G000 FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT
SEE A711 FOR FINISH, APPLIANCE AND ACCESSORY SCHEDULE
SEE SHEET SERIES A500 FOR WALL & ASSEMBLY TYPES
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
SEE SHEET SERIES A600 FOR DOOR & WINDOW TYPES
SEE SHEET SERIES A500 FOR CASEWORK DETAILS
SEE SHEET G000 FOR UNIT ACCESSIBILITY REQUIREMENTS
ALL RESIDENTIAL UNIT FURNITURE IS OWNER-PROVIDED, OWNER-INSTALLED
SEE SHEET A581 FOR CLOSET SHELVING LAYOUTS
SEE ACCESSIBILITY GENERAL SHEETS FOR REQUIRED BLOCKING IN TYPE A AND B UNITS
UPPER, LOWER, AND TALL MILLWORK CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE
UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYPICAL
ATTIC ACCESS PANELS WILL BE LOCATED IN SOME UNITS ON LEVEL 3, REFER TO LEVEL 3 RCP FOR FINAL LOCATIONS
WALL AND CEILING FINISH TEXTURES TO BE LIGHT KNOCK DOWN "SANTA FE"
A4
A516
115
EQ EQ
C4
A516
B4
A584
120M
ST-01
11.19
PNT-02 1' - 10"2' - 8 1/2"11.20
FILLER
8' - 6"
END PANEL
1" OVERHANG
A3
A516
WD-012"1'-6"2"2'-2 1/4"2'-6"09.01
TL-03
115
B4
A584
A4
A516
WB-01 120M
ST-01
PNT-02
TL-03
2"1'-6"2"2'-2 1/4"2'-6"WD-01
09.01
11.19
11.20
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
SEE ENLARGED FLOOR PLANS FOR INTERIOR ELEVATIONS
ALL MATERIALS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS
FLOORING MATERIAL TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR THRESHOLDS, UNLESS NOTED OTHERWISE. SEE A584 FOR TRANSITION DETAILS.
PREPARE FLOORS/WALLS TO RECEIVE FINISH MATERIAL. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. NOTIFY ARCHITECT IF CONDITIONS ARE INADEQUATE FOR REQUIRED INSTALLATION
REFER TO ROOM FINISH LEGEND ON SHEET SERIES A400 FOR MORE INFORMATION
SEE DIMENSION PLAN SHEET SERIES A120 FOR WALL TYPE LOCATIONS; SEE SHEET SERIES A500 FOR WALL TYPE AND ASSEMBLY DESCRIPTIONS
CONTRACTOR TO PROVIDE SOLID BLOCKING AT ALL CASEWORK, FIXED FURNISHINGS, TOILETS, TUBS, SHOWERS AND EQUIPMENT. COORDINATE WITH ENLARGED PLANS, ELEVATIONS, SECTIONS, FURNITURE, FIXTURE SHEETS, AND SPECIFICATIONS
SEE SHEET SERIES A500 FOR TYPICAL DETAILS
TILE INSTALLER TO FOLLOW TCNA & ANSI GUIDELINES
ALL FLOORING MATERIALS ARE TO RUN WALL TO WALL AND BENEATH CASEWORK
VERIFY LOCATION OF POINT OR ORIGIN OF TILE AND CONTROL JOINTS ON SHOP DRAWINGS AND WITH ARCHITECT ON-SITE PRIOR TO INSTALLATION
ALL GROUT TO BE SEALED
GENERAL CONTRACTOR TO COORDINATE POWER/DATA PLACEMENT FOR FF&E ITEMS WITH ARCHITECT
TILE PATTERN TO BE LAID AS SHOWN ON FINISH PLANS
PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS AND ALL OUTSIDE EDGES ON TILE WALLS; PROVIDE ALUMINUM EDGE MOULDING @ ALL TILE TO H.M. DOOR TRANSITIONS; SEE FINISH SCHEDULE + TRANSITION SCHEDULE + INTERIOR DETAILS
ALL FLOORING TRANSITIONS TO HAVE TRANSITION STRIP. SEE TRANSITION SCHEDULE ON A711
COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. PROVIDE 4" BACKSPLASH.
GENERAL NOTES - FINISH4'-0"4"6"
09.01
WB-02
FRP-01
22.34
22.24
22.35
TS-05
4'-0"6"
22.24
22.34
22.35
FRP-01
09.01
WB-02
TS-05
FILLER
2'-3"1'-0"2'-3"2'-9"2'-0"2'-9"
FILLER
230M212212
12.0711.1711.06
SF722.32
120M4"2"A4
A584
2124"23.12
06.25
PNT-02
ST-01
WB-01
09.01
115.2
09.01
CASEWORK TAG
101M
MODIFIED CASEWORK TYPE
AWS STANDARD CASEWORK TYPE
REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES
DIMENSIONS OF CASEWORK OUTLINED ON ELEVATIONS AND IN CASEWORK DETAILS BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1
3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2
sheet:
title:
D
C
B
A
D
C
B
A
123 4 5
123 4 5
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION
601 Euclid Ave. Suite CHelena, Montana59601
406-531-4745
unitedhousingpartners.com
UHP Design LLC
406-224-8220
revisions :
p r o j e c t # :
d a t e :
KEY PLAN
project:
stamp
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.
A406
ENLARGED
AMENITY
ELEVATIONS
SITE PLAN RC2
12.23.2025
24.0550
ADDRESSBozeman, MT
Hidden Creek
Building 3
KEYED NOTES
06.25 WOOD COLUMN, SEE STRUCTURAL
09.01 PAINTED GYP. PNT-1; RE: FINISH SCHEDULE
11.06 MICROWAVE (COUNTERTOP); RE: APPLIANCE SCHEDULE
11.17 UNDERCOUNTER ADA FRIDGE, SEE APPLIANCE SCHEDULE, AE601.
11.19 ELECTRIC FIREPLACE INSERT, TWO SIDED; RE: APPLIANCE SCHEDULE
11.20 WALL MOUNTED TV; ; OWNER PROVIDED, CONTRACTOR INSTALLED. PROVIDE BLOCKING FOR MOUNTING BRACKETS; POSITIONRECESSED POWER & INPUT RECEPTICLE CENTERED ON TV.
12.07 LOWER CABINETS, RE: FINISH SCHEDULE AND MILLWORK DETAILS
22.24 MOP SINK, RE: PLUMBING
22.32 KITCHEN FAUCET; SEE PLUMBING
22.34 WALL FAUCET, RE: PLUMBING
22.35 MOP HOOK, RE: PLUMBING
23.12 VENTED ACCESS PANEL, RE: MECHANICAL
FRP-01 FIBER-GLASS REINFORCED PANEL, FRP-01; RE: FINISH SCHEDULE
PNT-02 UNIT CASEWORK PAINT, PNT-02; RE: FINISH SCHEDULE
ST-01 QUARTZ COUNTERTOP AND BACKSPLASH, RE: FINISH SCHEDULE
TL-03 WALL TILE, TL-03; RE: FINISH SCHEDULE
TS-05 FRP CAP MOULDING, TS-06; RE: FINISH SCHEDULE
WB-01 WALL BASE, WB-01, RE: FINISH SCHEDULE
WB-02 COMPOSITE WALL BASE, WB-02; RE: FINISH SCHEDULE
WD-01 SOLID HARDWOOD, WD-01; RE: FINISH SCHEDULE
1/4" = 1'-0"A3COMMUNITY ROOM 1
1/4" = 1'-0"B3LEASING OFFICE 1
1/4" = 1'-0"D4 MAINTENANCE SINK - 1
1/4" = 1'-0"D3MAINTENANCE SINK - 2
1/4" = 1'-0"A2COMMUNITY ROOM 2
1/4" = 1'-0"B2LEASING OFFICE 2 5 Revision 2 10.10.25