Loading...
HomeMy WebLinkAbout033.1 A405 - Enlarged Amenity Plans and ElevationsII JJ 6 6 5 5 2 2 1 1 5.1 5.1 MAINTENANCE 110 SURPLUS DELIVERY ROOM 115B FITNESS 111 OFFICE 115ALEASING 115 COMMUNITY ROOM 114 RR 113 HALL 112 A405D2 A406 D1 D4 A3 3 3 D3 6' - 4"13' - 1"6' - 8"13' - 1"11' - 4"9' - 0"110.1 115.4 115.3 115.2 115.1 115 112 113 111.2 114SF1SF6SF6SF2 SF7W7CLCL9' - 0"4 3/4"3' - 2 3/4"3' - 9 1/4"2' - 10 3/4"2' - 3"1' - 4"8' - 2 3/4"CL7 1/4"3' - 5 1/2"1' - 5 3/4"2' - 6"2' - 0"14' - 1 1/4"2' - 3 1/4" CL 2' - 0 3/4"3' - 6"2' - 3 1/4" CL 2' - 0 3/4" Wi2 Wi1 Wi1 Wi2 Wi2 Wi2 Wi2Wi1 Wi71 We21We21 We1 We1 We1 Wi1Wi1Wi61 A406B3 B2 - - - A405 C1 11.20 22.17 06.44A406D4 D3 22.01 Wi3Wi71 4 1/4"26.02 Wi4 Wi43' - 7"2'-4" A2 2'-11 1/2"10'-0"5'-0 1/2"5'-1"8'-2"2'-9"SF8A3 A516 11.19 RAMP VTAC CLOSET VTAC CLOSET 23.12 23.1223.11 2'-11"5'-0"1'-4"12'-0"4'-0" 3'-6" 12'-0"1'-4"5'-0"1'-5"3'-11"6'-2 3/4"4'-11 1/4"23.11 06.25 06.25 4'-6"3'-5 1/4"D1 AS101 06.44 GENERAL NOTES - ENLARGED PLANS & ELEVATIONS A. B. C. D. E. F. G. H. SEE G001 FOR GENERAL NOTES ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE ALL ELECTRICAL OUTLETS ABOVE COUNTER TOPS SHOULD BE HORIZONTALLY ALIGNED AND MOUNTED HORIZONTALLY. SEE A1/A581 FOR MAX ALLOWABLE HEIGHT AT TYPE A. PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES & WASTE LINES COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. PROVIDE 4" BACKSPLASH IN THE SAME MATERIAL AS COUNTERTOP. SEE SHEET SERIES G000 FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT SEE A711 FOR FINISH, APPLIANCE AND ACCESSORY SCHEDULE SEE SHEET SERIES A500 FOR WALL & ASSEMBLY TYPES H. I. J. K. L. M. N. O. P. Q. SEE SHEET SERIES A600 FOR DOOR & WINDOW TYPES SEE SHEET SERIES A500 FOR CASEWORK DETAILS SEE SHEET G000 FOR UNIT ACCESSIBILITY REQUIREMENTS ALL RESIDENTIAL UNIT FURNITURE IS OWNER-PROVIDED, OWNER-INSTALLED SEE SHEET A581 FOR CLOSET SHELVING LAYOUTS SEE ACCESSIBILITY GENERAL SHEETS FOR REQUIRED BLOCKING IN TYPE A AND B UNITS UPPER, LOWER, AND TALL MILLWORK CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYPICAL ATTIC ACCESS PANELS WILL BE LOCATED IN SOME UNITS ON LEVEL 3, REFER TO LEVEL 3 RCP FOR FINAL LOCATIONS WALL AND CEILING FINISH TEXTURES TO BE LIGHT KNOCK DOWN "SANTA FE" ACCESSIBILITY LEGEND 30"48" CLR FLOOR SPACETYPE B 1104.1.1 30"52" CLR FLOOR SPACETYPE A 305 ACCESSIBLE ROUTE36"VARIESVARIES DOOR MANEUVERING CLEARANCESSEE G014 NOTE: SEE G SERIES FOR ADDITIONAL CLEARANCE REQUIREMENTS 10.04 10.03 10.05 10.10 22.07 10.13 22.14 10.08 6'-4"09.01A1 A584 A2 A584 22.07 10.04 10.05 10.03 6'-4"A1 A584 A2 A584 10.10 09.01 22.14 10.3010.14 6'-4"09.01 A1 A584 A2 A584 113 09.01A1 A584 A2 A5846'-4"1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. SEE ENLARGED FLOOR PLANS FOR INTERIOR ELEVATIONS ALL MATERIALS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS FLOORING MATERIAL TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR THRESHOLDS, UNLESS NOTED OTHERWISE. SEE A584 FOR TRANSITION DETAILS. PREPARE FLOORS/WALLS TO RECEIVE FINISH MATERIAL. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. NOTIFY ARCHITECT IF CONDITIONS ARE INADEQUATE FOR REQUIRED INSTALLATION REFER TO ROOM FINISH LEGEND ON SHEET SERIES A400 FOR MORE INFORMATION SEE DIMENSION PLAN SHEET SERIES A120 FOR WALL TYPE LOCATIONS; SEE SHEET SERIES A500 FOR WALL TYPE AND ASSEMBLY DESCRIPTIONS CONTRACTOR TO PROVIDE SOLID BLOCKING AT ALL CASEWORK, FIXED FURNISHINGS, TOILETS, TUBS, SHOWERS AND EQUIPMENT. COORDINATE WITH ENLARGED PLANS, ELEVATIONS, SECTIONS, FURNITURE, FIXTURE SHEETS, AND SPECIFICATIONS SEE SHEET SERIES A500 FOR TYPICAL DETAILS TILE INSTALLER TO FOLLOW TCNA & ANSI GUIDELINES ALL FLOORING MATERIALS ARE TO RUN WALL TO WALL AND BENEATH CASEWORK VERIFY LOCATION OF POINT OR ORIGIN OF TILE AND CONTROL JOINTS ON SHOP DRAWINGS AND WITH ARCHITECT ON-SITE PRIOR TO INSTALLATION ALL GROUT TO BE SEALED GENERAL CONTRACTOR TO COORDINATE POWER/DATA PLACEMENT FOR FF&E ITEMS WITH ARCHITECT TILE PATTERN TO BE LAID AS SHOWN ON FINISH PLANS PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS AND ALL OUTSIDE EDGES ON TILE WALLS; PROVIDE ALUMINUM EDGE MOULDING @ ALL TILE TO H.M. DOOR TRANSITIONS; SEE FINISH SCHEDULE + TRANSITION SCHEDULE + INTERIOR DETAILS ALL FLOORING TRANSITIONS TO HAVE TRANSITION STRIP. SEE TRANSITION SCHEDULE ON A711 COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. PROVIDE 4" BACKSPLASH. GENERAL NOTES - FINISH WB-01 10.32 22.17 09.01 2'-6"10.31 1'-6"7'-0"EQEQCL 13'-0"3'-7" 23.00 BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1 3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2 sheet: title: D C B A D C B A 123 4 5 123 4 5 UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION 601 Euclid Ave. Suite CHelena, Montana59601 406-531-4745 unitedhousingpartners.com UHP Design LLC 406-224-8220 revisions : p r o j e c t # : d a t e : KEY PLAN project: stamp THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. A405 ENLARGED AMENITY PLANS AND ELEVATIONS SITE PLAN RC2 12.23.2025 24.0550 ADDRESSBozeman, MT Hidden Creek Building 3 1/4" = 1'-0"A1AMENITY ENLARGED PLAN KEYED NOTES 06.25 WOOD COLUMN, SEE STRUCTURAL 06.44 PROVIDE BLOCKING FOR TV TO BE MOUNTED BY OUTLET (COORDINATE WITH ELECTRICAL) 09.01 PAINTED GYP. PNT-1; RE: FINISH SCHEDULE 10.03 18" GRAB BAR; RE: ACCESSORY SCHEDULE, -SEE BLOCKING REQUIREMENTS ON G021 10.04 36" GRAB BAR; RE: ACCESSORY SCHEDULE, -SEE BLOCKING REQUIREMENTS ON G021 10.05 42" GRAB BAR; RE: ACCESSORY SCHEDULE, -SEE BLOCKING REQUIREMENTS ON G021 10.08 MIRROR-SMALL, RE: ACCESSORY SCHEDULE 10.10 TOILET PAPER HOLDER; RE: ACCESSORY SCHEDULE 10.13 WALL MOUNTED SOAP DISPENSER; RE: ACCESSORY SCHEDULE 10.14 PAPER TOWEL DISPENSER & DISPOSAL; RE: ACCESSORY SCHEDULE 10.30 HORIZONTAL BABY CHANGING STATION; RE:ACCESSORY SCHEDULE 10.31 FITNESS MIRROR; RE: ACCESSORY SCHEDULE 10.32 BULLETIN CORK BOARD; RE: ACCESSORY SCHEDULE 11.19 ELECTRIC FIREPLACE INSERT, TWO SIDED; RE: APPLIANCE SCHEDULE 11.20 WALL MOUNTED TV; ; OWNER PROVIDED, CONTRACTOR INSTALLED. PROVIDE BLOCKING FOR MOUNTING BRACKETS; POSITIONRECESSED POWER & INPUT RECEPTICLE CENTERED ON TV. 22.01 DRAIN, SEE PLUMBING DRAWINGS 22.07 FLOOR MOUNTED TOILET; SEE PLUMBING 22.14 WALL MOUNT SINK; RE: PLUMBING. 22.17 WATER FOUNTAIN WITH BOTTLE FILLER. NOTE ADA MOUNTING HEIGHTS; SEE PLUMBING 23.00 SEE MECHANICAL 23.11 VTAC GRILLE, RE: MECHANICAL 23.12 VENTED ACCESS PANEL, RE: MECHANICAL 26.02 ELECTRICAL SWITCH GEAR; SEE ELECTRICAL WB-01 WALL BASE, WB-01, RE: FINISH SCHEDULE 1/4" = 1'-0"D1RESTROOM 2 1/4" = 1'-0"D4 RESTROOM 1 1/4" = 1'-0"D2RESTROOM 3 1/4" = 1'-0"D3RESTROOM 4 NOTE: ALL FURNITURE TO BE OWNER PROVIDED. 1/4" = 1'-0"C1FITNESS 2 2 Addendum 02 6.10.25