HomeMy WebLinkAbout032 A514 - Typical Roof Canopy DetailsCORRUGATED METAL ROOFING
METAL FLASHING
SELF ADHERED FLEXIBLE FLASHING
SCHEDULED WALL
2 X LEDGER - SEE STRUCT
HANGER PER STRUCT
WRB
METAL FLASHING
ROOF JOIST PER STRUCT
2 x BLOCKING - SEE STRUCT
FASCIA BOARD
COUNTER FLASHING
CORRUGATED METAL ROOFINGMETAL FLASHING DRIP EDGE1" MIN
GUTTER ATTACHED THROUGH BENT PLATE @ 4'-0" O.C.
24 GA. PREFINISHED FABRICATED ALUMINUM GUTTER
ALUM GUTTER BRACKETS @ 36" O.C., WELDED TO INTERIOR FACE OF GUTTER
24 GA. PREFINISHED METAL FASCIA TRIM
FOAM CLOSURE
B5
A514A4
A514
A5
A514
CORRUGATED METAL ROOFING
SLOPED 2X LEDGER (BEYOND)
SHEATHING PER STRUCT
ROOF JOIST - SEE STRUCT FOR SPACING
NOTE: STAIN ALL EXPOSED WOOD AT CANOPIES
CORRUGATED METAL ROOFING
SIDING - SEE ELEVATIONS
METAL FLASHING
SELF ADHERED FLEXIBLE FLASHING
SCHEDULED WALL
SLOPE 1/8" / 12"
2 x BLOCKING
METAL FLASHING
SIDING - SEE ELEVATIONS
WRB
ROOF JOIST - SEE STUCT
98
FU.N.O. ON DIMENSION PLANS4' - 0 1/2"A2
A5141/8" / 1'-0"SLOPE8' - 6"
A5
A514
ROOF DOWNSPOUT
CANOPY GUTTER - TIE INTO ROOF DOWNSPOUT
ROOF DOWNSPOUT
RA-2
7
F
E
5.1
A602A2
A514
ROOF DOWNSPOUT
SLOPE
CANOPY GUTTER - TIE INTO ROOF DOWNSPOUT4' - 0 1/2"8' - 0"
A5
A514
3
FLEXIBLE FLASHINGWEATHER RESISTIVE BARRIER
LINE LEGEND
1 1/2" = 1'-0"A2ROOF CANOPY SECTION
3" = 1'-0"B5ROOF CANOPY FACIA DETAIL
3" = 1'-0"A4 ROOF CANOPY WALL DETAIL CONNECTION
3" = 1'-0"A5 ROOF CANOPY SIDE CONNECTION DETAIL BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1
3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2
sheet:
title:
D
C
B
A
D
C
B
A
123 4 5
123 4 5
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION
601 Euclid Ave. Suite CHelena, Montana59601
406-531-4745
unitedhousingpartners.com
UHP Design LLC
406-224-8220
revisions :
p r o j e c t # :
d a t e :
KEY PLAN
project:
stamp
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.
A514
TYP ROOF
CANOPY
DETAILS
BLDG 1-4
SITE PLAN RC 2
12.23.2025
24.0550
ADDRESSBozeman, MT
Hidden Creek
Site
1/2" = 1'-0"A1TYP ROOF CANOPY PLAN @ STAIR ENTRY BLG 1-4
B1TYP CANOPY BLDG 1-4 AXON VIEW
D3CANOPY BLDG 2-3 ONLY AXON VIEW
1/2" = 1'-0"D5 TYP ROOF CANOPY PLAN @ CORNER ENTRY BLG 2-3
BUILDING 2 - 3 ONLY