Loading...
HomeMy WebLinkAbout032 A514 - Typical Roof Canopy DetailsCORRUGATED METAL ROOFING METAL FLASHING SELF ADHERED FLEXIBLE FLASHING SCHEDULED WALL 2 X LEDGER - SEE STRUCT HANGER PER STRUCT WRB METAL FLASHING ROOF JOIST PER STRUCT 2 x BLOCKING - SEE STRUCT FASCIA BOARD COUNTER FLASHING CORRUGATED METAL ROOFINGMETAL FLASHING DRIP EDGE1" MIN GUTTER ATTACHED THROUGH BENT PLATE @ 4'-0" O.C. 24 GA. PREFINISHED FABRICATED ALUMINUM GUTTER ALUM GUTTER BRACKETS @ 36" O.C., WELDED TO INTERIOR FACE OF GUTTER 24 GA. PREFINISHED METAL FASCIA TRIM FOAM CLOSURE B5 A514A4 A514 A5 A514 CORRUGATED METAL ROOFING SLOPED 2X LEDGER (BEYOND) SHEATHING PER STRUCT ROOF JOIST - SEE STRUCT FOR SPACING NOTE: STAIN ALL EXPOSED WOOD AT CANOPIES CORRUGATED METAL ROOFING SIDING - SEE ELEVATIONS METAL FLASHING SELF ADHERED FLEXIBLE FLASHING SCHEDULED WALL SLOPE 1/8" / 12" 2 x BLOCKING METAL FLASHING SIDING - SEE ELEVATIONS WRB ROOF JOIST - SEE STUCT 98 FU.N.O. ON DIMENSION PLANS4' - 0 1/2"A2 A5141/8" / 1'-0"SLOPE8' - 6" A5 A514 ROOF DOWNSPOUT CANOPY GUTTER - TIE INTO ROOF DOWNSPOUT ROOF DOWNSPOUT RA-2 7 F E 5.1 A602A2 A514 ROOF DOWNSPOUT SLOPE CANOPY GUTTER - TIE INTO ROOF DOWNSPOUT4' - 0 1/2"8' - 0" A5 A514 3 FLEXIBLE FLASHINGWEATHER RESISTIVE BARRIER LINE LEGEND 1 1/2" = 1'-0"A2ROOF CANOPY SECTION 3" = 1'-0"B5ROOF CANOPY FACIA DETAIL 3" = 1'-0"A4 ROOF CANOPY WALL DETAIL CONNECTION 3" = 1'-0"A5 ROOF CANOPY SIDE CONNECTION DETAIL BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1 3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2 sheet: title: D C B A D C B A 123 4 5 123 4 5 UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION 601 Euclid Ave. Suite CHelena, Montana59601 406-531-4745 unitedhousingpartners.com UHP Design LLC 406-224-8220 revisions : p r o j e c t # : d a t e : KEY PLAN project: stamp THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. A514 TYP ROOF CANOPY DETAILS BLDG 1-4 SITE PLAN RC 2 12.23.2025 24.0550 ADDRESSBozeman, MT Hidden Creek Site 1/2" = 1'-0"A1TYP ROOF CANOPY PLAN @ STAIR ENTRY BLG 1-4 B1TYP CANOPY BLDG 1-4 AXON VIEW D3CANOPY BLDG 2-3 ONLY AXON VIEW 1/2" = 1'-0"D5 TYP ROOF CANOPY PLAN @ CORNER ENTRY BLG 2-3 BUILDING 2 - 3 ONLY