HomeMy WebLinkAbout021 SP012 - Building 3 Elevations46'ENTRANCE
CANOPY TYPICAL: 1 PER ENTRANCE
EXTERIOR LIGHTING TYPICAL: 1 OR 2 PER ENTRANCE
MECHANICAL EQUIPMENT TYPICAL: 1 PTAC UNIT PER UNIT
BALCONY TYPICAL: 1 PER UNIT
EXTERIOR LIGHTING TYPICAL: 1 PER BALCONY
ENTRANCE14'23'10'38'3" / 1'-0"14.04°3" / 1'-0"14.04°9" / 1'-0"36.87°9" / 1'-0"36.87°3" / 1'-0"14.04°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°10'36'10'33'30'30'30'30'30'
150'
WINDOW & DOOR TRIM TYPICAL: ENGINEERED WOOD SIDING TRIM, SIZE 5/4X4, COLOR TO MATCH SIDING 5'3'5'25'VTACBENCH
ENTRANCE
CANOPY TYPICAL: 1 PER ENTRANCEEXTERIOR LIGHTING TYPICAL: 1 OR 2 PER ENTRANCE
MECHANICAL EQUIPMENT TYPICAL: 1 PTAC UNIT PER UNIT
BALCONY TYPICAL: 1 PER UNIT
EXTERIOR LIGHTING TYPICAL: 1 PER BALCONY
WINDOW & DOOR TRIM TYPICAL: ENGINEERED WOOD SIDING TRIM, SIZE 5/4X4, COLOR TO MATCH SIDING33'3'10'46'33'10'43'3" / 1'-0"14.04°3" / 1'-0"14.04°9" /
1
'
-
0
"
36.8
7
°9" / 1'-0"36.87°3" / 1'-0"
14.04°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°
30'30'30'30'
ENTRANCE
CANOPY TYPICAL: 1 PER ENTRANCEEXTERIOR LIGHTING TYPICAL: 1 OR 2 PER ENTRANCEMECHANICAL EQUIPMENT TYPICAL: 1 PTAC UNIT PER UNIT
BALCONY TYPICAL: 1 PER UNIT
EXTERIOR LIGHTING TYPICAL: 1 PER BALCONY
WINDOW & DOOR TRIM TYPICAL: ENGINEERED WOOD SIDING TRIM, SIZE 5/4X4, COLOR TO MATCH SIDING
LIGHTING UNDER CANOPY
FIREPLACE10'33'43'14'23'10'46'3" / 1'-0"14.04°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°9" / 1'-0"36.87°5'3'5'25'30'30'30'30'
LOW WALL
ENTRANCE
CANOPY TYPICAL: 1 PER ENTRANCE 14'33'47'4'10'33'EXTERIOR LIGHTING TYPICAL: 1 OR 2 PER ENTRANCE
EXTERIOR LIGHTING TYPICAL: 1 PER STAFF DOOR3" / 1'-0"14.04°MECHANICAL EQUIPMENT TYPICAL: 1 PTAC UNIT PER UNIT
BALCONY TYPICAL: 1 PER UNIT
EXTERIOR LIGHTING TYPICAL: 1 PER BALCONY
9" / 1'-0"36.87°3" / 1'-0"14.04°3" / 1'-0"14.04°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°9" / 1'-0"36.87°9" /
1
'
-
0
"
36.8
7
°
9" /
1
'
-
0
"
36.8
7
°5'26'ELECTRICAL GEAR LOCATION(METER BANKS)WINDOW & DOOR TRIM TYPICAL: ENGINEERED WOOD SIDING TRIM, SIZE 5/4X4, COLOR TO MATCH SIDING
30'30'30'30'30'
TRELLIS SEE LANDSCAPE
MATERIALS LEGEND
ROOFING #1: ASPHALT SHINGLE
SIDING #1: ENGINEERED WOOD SIDINGBOARD & BATTENCOLOR "WHITE"
CAST IN PLACE CONCRETE
ROOFING #2: METAL ROOF
SIDING #2: ENGINEERED WOOD SIDINGBOARD & BATTENCOLOR "ACCENT - BLUE"
SIDING #3: ENGINEERED WOOD SIDINGBOARD & BATTENCOLOR "GREY"
SIDING #4: ENGINEERED WOOD SIDINGBOARD & BATTENCOLOR "BLACK"
ACCENT SIDING ELKHORN "DOU BLEND" 6" LAP. DECK FASCIA BOARD, SOFIT @ EXTERIOR STAIRS
ELEVATION TRANSPARENCY
ELEVATION
WINDOW
5X5
5X6.5
5.5X2.5
4312 SF
702 SF
12
NORTH
75 SF
%TRANSPARENCY
STOREFRONT36 SF
6X6
3
12
2
X
X
X
X
=
=
=
=
390 SF
165 SF
72 SF
17.12%
5437 SF
867 SF
8
EAST
425 SF
118 SF
17
8
2
X
X
X
X
=
=
=
=
260 SF
110 SF
72 SF
18.12%
4090 SF
429.5 SF
10
SOUTH
25 SF
263 SF
2
6
2
X
X
X
X
=
=
=
=
195 SF
137.5 SF
72 SF
16.93%
5465 SF
722 SF
10
WEST
350 SF
76 SF
14
5
2
X
X
X
X
=
=
=
=
162.5 SF
137.5 SF
72 SF
14.60%
TOTALELEVATION
ORIENTATIONFRONTFRONTSIDESIDE
19,304 SF
2,720.5 SF
493 SF
16.65%BUILDING 2BUILDING 3BUILDING 5
BUILDING 4
BUILDING 1
3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2
sheet:
title:
D
C
B
A
D
C
B
A
123 4 5
123 4 5
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION
601 Euclid Ave Suite CHelena, MT 59601
unitedhousingpartners.com
UHP Design LLC
revisions :
p r o j e c t # :
d a t e :
KEY PLAN
project:
stamp
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.
SP012
BLDG 3
ELEVATIONS
Site Plan RC#2
12/23/25
xxx
Bozeman, MT
Hidden Creek
Community
3/32" = 1'-0"
BLDG 3_FRONT_EAST2
3/32" = 1'-0"
BLDG 3_FRONT_NORTH3 3/32" = 1'-0"
BLDG 3_SIDE_SOUTH4
3/32" = 1'-0"
BLDG 3_SIDE_WEST1
THIS SHEET SATISFIES REQUIREMENTS OF SITE PLAN SUBMITTAL REQUIREMENTS: BUILDING DESIGN & SIGNAGE: 85,86,87SEE CIVIL, LANDSCAPE, & MEP DRAWINGS FOR ADDITIONAL INFORMATION
SITE PLAN SUBMITTAL REQUIREMENTS