Loading...
HomeMy WebLinkAbout012.1 SP002 - Fire Plan & Landscape DiagramFUTURE PAD SITE18600 SFFUTURE PAD SITE 8000 SF OAK PARK DRIVEBUILDING 4 BUILDING 1 BUILDING 3BUILDING 2 BUILDING 5 FIRE RISER ROOMW/FIRE ALARM PANEL+ FDC FIRE RISER ROOMW/FIRE ALARM PANEL+ FDC FIRE RISER ROOMW/FIRE ALARM PANEL+FDC FIRE RISER ROOMW/FIRE ALARM PANEL+ FDC FIRE RISER ROOMW/FIRE ALARM PANEL+ FDC STANDPIPE HYDRANT 2,152HYDRANT 1,790 HYDRANT 1,789 HYDRANT 815 HYDRANT 1,788 R 10 0 ' - 0 " FUTURE HYDRANT STRIPED & SIGNED: NO PARKINGALONG ENTIRE LENGTH OF OAK PARK DRIVE64'-0"40'-0"157'-0" 67'-0" 200'-0" 36 UNITS3 FLOORS, TYPE VB CONSTRUCTION13 R SPRINKLER SYSTEM 34 UNITS3 FLOORS, TYPE VB CONSTRUCTION13 R SPRINKLER SYSTEM 36 UNITS3 FLOORS, TYPE VB CONSTRUCTION13 R SPRINKLER SYSTEM 24 UNITS3 FLOORS, TYPE VB CONSTRUCTION13 R SPRINKLER SYSTEM 52 UNITS4 FLOORS, TYPE VA CONSTRUCTIONFULL SPRINKLER SYSTEMR 150' - 0"170'-0" 150'-0"20'-0"BREAK-AWAY GATESEE CIVIL FIRE LANESTRIPED & SIGNED: NO PARKING LEGEND ENTRANCE NO PARKINGSEE CIVIL FOR MORE INFORMATION MEASUREMENTS FOR FIRE APPARATUSLEGENDNot Used LANDSCAPED BLOCK FRONTAGESLANDSCAPED BLOCK FRONTAGES 38.510.030.C Building Placement10' minimum front setback 13.5' Front Setback Provided Building EntrancesBuilding entrances must be visible and directly accessible from the street See sheets SP006, SP009, SP012, SP015, SP018 Facade TransparencyFor residential uses - at least 15% of the entire facade. Windows must be provided on all habitable floors of the facade. See sheets SP006, SP009, SP012, SP015, SP018 Weather ProtectionProvide weather protection at least 3' deep over residential entries Weather Protection Location: See this sheet, SP006, SP009, SP012, SP015, SP018Weather Protection Design: See Sheet A514 Parking LocationParking must be placed to the side, rear, below or above uses. Parking areas limited to no more than 50% of the street frontage with landscape buffer Landscape buffer-Location: See this sheetDesign and Plant Information: See Landscape Drawings LandscapingArea between the street and building must be landscaped, private porch or patio space, and/or pedestrian-oriented space. For setbacks adjacent to buildings with windows, provide low level landscaping that maintains views between the building and the street. Also provide plant materials that screen any blank walls and add visual interest at both the pedestrian scale and motorist scale. For extended wall areas, provide for a diversity of plant materials and textures to maintain visual interest from a pedestrian scale. Provided, See Landscape Drawings Sidewalk Width6' minimum sidewalks are required adjacent to arterial streets and public parks and 5' minimum width in other areas See Civil 38.510.030.J Special Residential Block Frontage StandardsOption 1. Raised deck or porch optionOption 2. Front setback option. 10' min required with landscaped area (38.550) / low fence/hedge (38.350/060)Option 3. Ground floor is 3' min above grade. Departure RequestedFor areas less than 10' from a sidewalk, this project is requesting a departure. Transition design measures that adequately protect the privacy and comfort of the residential unit and the attractiveness and usefulness of the pathway include a railing at each private patio porch. Additionally, intentional landscaping is used to create a buffer between sidewalks. Railing Locations: See Sheet SP006, SP009, SP012, SP015, SP018Railing Design: See Sheet A522Plant Design and Information: See Landscape Drawings Not Used8'25'5'OPEN SPACE SEE SP004OPEN SPACE SEE SP004 OPEN SPACE SEE SP004OPEN SPACE SEE SP004COVERED ENTRY, SEE A514 FOR TYP DETAILING RAILING @ FIRST FLOOR PATIO,SEE A522 FOR TYP DETAILING LEGENDSERVICE AREASSERVICE AREAS 38.520.070 ScreeningRequired around dumpsters Screening Location: See this sheetDesign & Plant information: See Landscape Drawings Required in front of utility metersScreening Location: See this sheetDesign & Plant information: See Landscape Drawings 38.550.050.C Screening Required4' screening reqd when adjacent to residential lotFence & landscaping providedFor location: See this SheetFor Design, Specifications, and Plant information: See Landscape DrawingsScreening reqd along public ROWFor location: See this SheetFor Design and Plant information: See Landscape Drawings PARKING LOT SCREENINGPARKING LOT SCREENING LEGEND9' 9' 5' 3'6'6'6'6'5' 3' 9'11'16'11'11'10'5'10'10'10'6'10'5'10'10'8'7'12'7'12'BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1BUILDING 2BUILDING 3BUILDING 5 BUILDING 4 BUILDING 1 3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2 sheet: title: D C B A D C B A 123 4 5 123 4 5 UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION 601 Euclid Ave Suite CHelena, MT 59601 406-531-4745 unitedhousingpartners.com UHP Design LLC 406-224-8220 revisions : p r o j e c t # : d a t e : KEY PLAN project: stamp THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. SP002 FIRE PLAN & LANDSCAPE DIAGRAM Site Plan RC#2 12/23/25 xxx Bozeman, MT Hidden Creek Community 1" = 50'-0" FIRE PLAN1 1" = 40'-0" BLOCK FRONTAGE & SCREENING DIAGRAM3