HomeMy WebLinkAbout045 - L2.0 - IRRIGATION PLANWSWSWSWSSSSDSDSDSD6WHYDSDSD SD UPUPDNUPBP
BP
BP BPBPOHPOHPOHPOHPOHPOHPOHPDN0°16'39"E14.03'N0°03'23"E 28.07'4.01'52.17'N89°19'10"E 122.34'N0°03'23"E 60.15'S89°21'50"W 202.40'N89°25'08"E 80.14'S0°09'19"W 74.20'DPTVFXXW W W W W W W W W W W
BFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBP BP BP NGNGNGNGNGNGNGNGNGNGSSSSSSBF BF BF BFBPBPBP
BPBTV BTV BT
V
BTVBTV BTV BTV BTV BTV BTV BTV BTV BTV BTV
NGNGNGNGS S S S S S S S S S S SSDSDSDSDSDSDSDSDSDSDFCOCO
EDP
TWXXXOH
P
OH
POHP SDSDSDWSWSWSWSSSSDSDSDSD6WHYDSDSDSDUPUPDNUP
BP
BP
BP BPBPOHPOHPOHPOHPOHPOHPOHPDDPTVFXXW W W W W W W W W W W
BFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBP BP BP NGNGNGNGNGNGNGNGNGNGSSSSSSBF BF BF BFBPBPBP
BPBTV BTV BT
V
BTVBTV BTV BTV BTV BTV BTV BTV BTV BTV BTV
NGNGNGNGS S S S S S S S S S S SSDSDSDSDSDSDSDSDSDSDFCOCO
EDP
TWXXXOH
P
OH
POHP SDSDSDN0°16'39"E14.03'N0°03'23"E 28.07'4.01'52.17'N89°19'10"E 122.34'N0°03'23"E 60.15'S89°21'50"W 202.40'N89°25'08"E 80.14'S0°09'19"W 74.20'WR2D10.181"D20.721"FLOOR 1 POCBFC1"1"1"1"D30.631"DESIGNED BY:QUALITY CHECK:JOB NO.FIELDBOOKDRAWN BY:DATE:G25-160 L2.XREV DATE REVISION
PRINTED 2026-01-14, BY ALY ROSS, I:\2025\GTF\25-160 112 S CHURCH AVE BZM\06_CADD\LANDSCAPE\G25-160 L2.X.DWG
THE DEPOT ON CHURCH
BOZEMAN, MT
IRRIGATION PLAN, NOTES & SCHEDULE
AMRAMRJCC12-05-2525-160SHEETL2.01 1/14/26 CITY OF BOZEMAN REVIEW
.DWGPAGE SETUP 2023_TDH_22X34_AS_11X17_L
Engineering
tdhengineering.com L2.0 IRRIGATION SHEET PLAN SHEET L2.2PROPOSED BUILDING, PER ARCHALLEYWAY
SOUTH CHURCH AVE.EXIST. BLDG.EXIST. BLDG.EXIST. BLDG.EXIST. BLDG.WATER BUDGET CALCULATORIRRIGATION NOTES1.ALL LANDSCAPE AREAS WITHIN THE SITE SHALL BE IRRIGATED WITH AN AUTOMATIC UNDERGROUND IRRIGATION SYSTEM. THE USE OF HOSE BIBS ON THE EXTERIOR OFEXISTING OR PROPOSED STRUCTURES IS NOT ACCEPTABLE.2.A POINT OF CONNECTION WILL BE LOCATED AT THE NORTHWEST CORNER OF THE BUILDING ON GROUND FLOOR AND CONNECTED TO CITY WATER SERVICE. BACKFLOWPREVENTION DEVICE SHALL BE PROFESSIONALLY INSTALLED PER LOCAL JURISDICTION REQUIREMENTS.3.AUTOMATIC IRRIGATION SYSTEM SHALL CONNECT TO CITY WATER SYSTEM. IRRIGATION SYSTEM TO MEET ALL LOCAL AND STATE CODES. FINAL POINT OF CONNECTION,FLOW AND PRESSURE TO BE DETERMINED AND COORDINATED WITH OWNER'S REPRESENTATIVE.4.ALL IRRIGATION SYSTEMS AND LANDSCAPED AREAS SHALL BE DESIGNED, CONSTRUCTED, OPERATED AND MAINTAINED SO AS TO PROMOTE WATER CONSERVATION ANDPREVENT WATER OVERFLOW OR SEEPAGE INTO THE STREET, SIDEWALK OR PARKING AREAS.5.ALL TREE AND SHRUB BEDS AND ROOFTOP PLANTERS ARE TO BE IRRIGATED WITH AN AUTOMATIC DRIP IRRIGATION SYSTEM OR ACCEPTABLE ALTERNATIVE.6.THE IRRIGATION SYSTEM IS TO BE ADJUSTED TO MEET THE WATER EQUIPMENTS OF THE INDIVIDUAL PLANT MATERIAL.7.CONTRACTOR SHALL MAKE HIMSELF AWARE OF ALL EXISTING AND PROPOSED SITE CONDITIONS, INCLUDING PLANTING, GRADING, BUILDING CONSTRUCTION, WATERDEVELOPMENT, ELECTRIC SERVICE, AND SUPPLY, PRIOR TO COMMENCEMENT OF WORK. NOTE ANY SLEEVES AND IRRIGATION STUBS FOR FUTURE WORK.8.CONTRACTOR SHALL LOCATE AND PROTECT ALL UNDERGROUND UTILITIES, CONDUITS, AND STRUCTURES AND SHALL ASSUME RESPONSIBILITY FOR ANY DAMAGE INCURRED.9.THE IRRIGATION CONTRACTOR SHALL CAREFULLY SCHEDULE HIS WORK WITH THE CONTRACTOR AND ALL OTHER CONSTRUCTION ACTIVITIES.10.THE IRRIGATION CONTRACT INCLUDES SUPPLYING AND INSTALLING ALL MATERIALS AND EQUIPMENT FOR A COMPLETE, AUTOMATIC IRRIGATION SYSTEM. ANY ITEMSREQUIRED TO CONFORM WITH SUCH INTENT ARE CONSIDERED TO BE INCIDENTAL TO THE WORK.11.DO NOT WILLFULLY INSTALL THE SYSTEM WHEN OBVIOUS OBSTRUCTIONS, GRADE CHANGES AND SITE GEOMETRY EXIST. SUCH DIFFERENCES SHALL BE REPORTED TOTHE OWNER'S REPRESENTATIVE. IN THE EVENT NOTIFICATION IS NOT MADE, THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY NECESSARY REVISIONS.12.CONTRACTOR SHALL REFER TO LANDSCAPE AND UTILITY PLANS WHEN LAYING OUT HEAD PLACEMENT AND TRENCHING.13.REFER TO ARCHITECTURAL, CIVIL DRAWINGS FOR ADDITIONAL INFORMATION, IF CONFLICTS EXIST CONTRACTOR SHALL BRING THESE TO THE ATTENTION OF THE OWNER'SREPRESENTATIVE PRIOR TO COMMENCING WORK.INSTALLATION NOTES1.PRIOR TO COMMENCING ANY WORK, THE APPLICANT MUST CONTACT THE CITY OF BOZEMAN WATER CONSERVATION DIVISION TO SCHEDULE A PRE-INSTALLATION MEETING.2.IRRIGATION CONTROLLER LOCATION:INSTALL IRRIGATION CONTROLLER ASSEMBLY IN THE APPROXIMATE LOCATION INDICATED ON IRRIGATION PLANS. COORDINATE ELECTRICAL INSTALLATION AND CONNECTIONWITH APPROPRIATE SUB-CONTRACTOR PRIOR TO CONSTRUCTION. COORDINATE EXACT PLACEMENT OF CONTROLLER WITH OWNER'S REPRESENTATIVE PRIOR TOCONSTRUCTION.3.IRRIGATION EQUIPMENT MAY BE SHOWN OUTSIDE OF THE PLANTING AREA IN THE HARDSCAPE FOR CLARITY ONLY. INSTALL ALL IRRIGATION COMPONENTS IN LANDSCAPEDAREA.4.THE NEW IRRIGATION SYSTEM DESIGN WAS DESIGNED WITH THE FOLLOWING ASSUMPTIONS: SYSTEM DESIGN PRESSURE REQUIREMENTS 80 PSI. BOOSTER PUMP TO BEPROVIDED IF AVAILABLE PRESSURE IS NOT SUFFICIENT TO OPERATE SYSTEM. CONTRACTOR TO VERIFY AVAILABLE PRESSURE AND FLOW ON SITE AT THE POINT OFCONNECTION (POC) PRIOR TO CONSTRUCTION AND REPORT IN WRITING ANY DISCREPANCIES BETWEEN THESE ASSUMPTIONS AND ACTUAL FIELD CONDITIONS.5.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION.6.THE DRAWINGS ARE DIAGRAMMATIC THEREFORE, THE FOLLOWING SHOULD BE NOTED:6.1.IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING ARES FOR GRAPHIC CLARITY ONLY. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, UTILITIES,PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE.6.2.VALVE BOXES SHALL BE LOCATED GENERALLY AS SHOWN ON PLANS, FINAL PLACEMENT/LOCATION SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TOINSTALLATION.6.3.USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF CROSS TYPE FITTINGS IS NOT PERMITTED.7.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT:7.1.TWO OPERATION KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVE.7.2.TWO QUICK COUPLING KEYS, EACH WITH ATTACHED SWIVEL HOSE ELL FOR OPERATION OF THE QUICK COUPLING VALVES SHOWN ON THE DRAWINGS.8.CONTRACTOR RESPONSIBLE FOR PROVIDING OWNER WITH IRRIGATION AS-BUILTS AT COMPLETION OF INSTALLATION.9.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE TO BE INSTALLED FOR BOTH PIPING AND ELECTRICALWIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTINGHARDSCAPE WHERE SLEEVING WAS NOT INSTALLED, REQUIRES HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. SLEEVE AND CONDUIT SIZES SHALL BE A MINIMUMOF TWICE THE AGGREGATE DIAMETER OF ALL PIPE AND WIRE CONTAINED WITHIN SLEEVE OR CONDUIT PIPE.10.INSTALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITYCODES.11.THE FINAL GRADE OF LANDSCAPE DESIGN ELEMENTS SUCH AS ROCK AND WOOD MULCH MUST BE BELOW THE TOP OF THE CURB TO PREVENT MULCH FROM MIGRATINGINTO THE CURB LINE AND SIDEWALK. THE CURB REVEAL MUST NOT POSE A TRIP HAZARD.12.DRIP IRRIGATION SHALL BE INSTALLED TO BE EASILY FLUSHED.SEE SHEETS L2.2-L2.6 FOR ROOFTOP&BALCONY PLANSNOTE:1)359 SF OF ROOFTOP PLANTER AREA HAS BEEN EXCLUDED FROM WATER BUDGETAS IT IS NOT REVIEWED AS PART OF THE CURRENT WATER CONSERVATION MANUAL.2)ROOFTOP PLANTER AREAS HAVE BEEN PLANTED WITH ONLY PLANT FACTOR .3PLANT MATERIAL OR LESS AND WILL BY IRRIGATED WITH NETAFIM DRIP IRRIGATION.DECODER NOTES1.ALL ELECTRIC CONTROL VALVES SHALL UTILIZE FD-TURF DECODERS FOR COMMUNICATION TO CONTROLLER.2.VALVE WIRING SHALL CONSIST OF PAIGE ELECTRIC 14 AWG 2-WIRE, JACKETED, DECODER WIRE SUITABLE FOR DIRECT BURIAL, PER MANUFACTURER'SSPECIFICATIONS.3.WIRE-TO-DECODER CONNECTIONS SHALL BE MADE USING DBR-6 DRY SPLICE CONNECTORS FROM 3M; DECODER-TO-SOLENOID CONNECTIONS SHALL BE MADEUSING DBY DRY SPLICE CONNECTORS FROM 3M.4.THE DECODER WIRE PATH SHALL BE GROUNDED EVERY 500 FEET OR 8 DECODERS, WHICHEVER OCCURS SOONEST. GROUNDING SHALL ALSO BE INSTALLED AT ALLTERMINATIONS OF THE DECODER WIRE PATH.5.DECODER GROUNDING SHALL CONSIST OF A COPPER PLATE 4-INCH X 96-INCH CONNECTED VIA 6-AWG BARE COPPER WIRE TO THE DECODER GROUNDING LEAD.THE GROUND PLATE SHALL BE PERPENDICULAR TO THE WIRE PATH AND LOCATED 8-FEET AWAY FROM THE DECODER.6.CONTROLLER GROUNDING SHALL CONSIST OF A 5/8-INCH X 96-INCH COPPER GROUND ROD AND A 4-INCH X 96-INCH COPPER PLATE, BOTH CONNECTED TOTHE GROUND LUG OF THE CONTROLLER BY 6-AWG BARE COPPER WIRE. THE GROUND ROD AND GROUND PLATE SHALL BOTH BE LOCATED 8-FEET FROM THECONTROLLER AND PERPENDICULAR TO EACH OTHER.11