HomeMy WebLinkAbout22 Cutsheet Overhead Garage DoorT HERMACORE® APDOOR S YSTEMS
INSULATED SECTIONAL ADVANCED PERFORMANCE DOORS
850
CLIMATE CONTROL.
DURABILITY.
EASE OF MAINTENANCE.
INDUSTRY EXPERTS,
DELIVERING TOTAL SOLUTIONS
THERMACORE AP DOOR SYSTEM MODEL 850 INSULATED SECTIONAL AP DOORS
2
Cover image: Model 850, large thermal lites, Brown paint finish
Options
• Large thermal lites (25" x 13"); black frame standard;
insulated lites (24" x 6"); optional color matched frame
• Glass: insulated tempered, multi-wall polycarbonate in
clear, bronze, or white
• High-cycle springs
• High-usage components
• Electric operator
• Chain hoist
• Cable failure device
• Exhaust ports
• Enhanced thermal performance jamb seal
• EPDM4 outer bulb seal recommended for more
extreme environments
Standard Features at a Glance
Panel Thickness 3" (76.2 mm)
Maximum Standard Width 40’2” (12243 mm)
Maximum Standard Height 24’1” (7317 mm)
Exterior Steel .015" (.38 mm)
Exterior Surface Stucco Embossed/Pinstripe
U-factor1 0.07 (.22 W/K m²)
R-value2 26 (4.58 K m²/W)
STC Rating3 Class 22
Air Infiltration:
at 15 mph (24 kmph).09 cfm/ft² (1.65 m³/hr/m²)
IECC®Meets requirements for U-factor
and air infiltration
Thermal Break 1-3/4" wide PVC thermal break;
PVC thermal break on end stiles
Standard Springs 10,000 cycles
Joint Profile Dual barrier tongue-in-groove
meeting rail consists of the industry’s
first dual tongue and groove joint
profile (patents pending)
Perimeter Protection Header seal; bottom weather
seal; rigid PVC retainer with dual-
durometer PVC bulb seal
Continuous Hinge Strip Two continuous steel strips at top
and bottom of section
Exterior Color White, Brown, Almond, Sandstone
Interior Color White
Limited Warranty 10-year delamination
1-year material and workmanship
3-year/20,000 cycle door and
operator system (material and
workmanship)
1 U-factor is a measure of thermal efficiency. The lower the U-factor the
greater the insulating properties of the door. U-factor is independently
tested and verified per ANSI/DASMA 105 using solid doors and specific
product sizes..
2 R-value is a measure of thermal efficiency. The higher the R-value the
greater the insulating properties of the door. Overhead Door Corporation
uses a calculated door section R-value for our insulated doors.
3 Sound Transmission Class (STC): how well the door reduces airborne
sound. The higher the number the better sound reduction.
4 Ethylene propylene diene monomer rubber. Used in the automotive
industry for its superior durability and wearability.
www.dasma.com/thermal
Overhead Door Corporation participates in the DASMA Thermal Performance Verification Program. The program verifies the thermal performance of sectional garage doors. The lower the U-Factor rating, the better the thermal performance.
Symbol indicates verified U-Factor rating in accordance with the DASMA Thermal Performance Verification Program.
Overhead Door™ Brand participates
in the DASMA Thermal Performance
Verification Program. The program verifies
the thermal performance of sectional
doors. The lower the U-factor rating, the
better the thermal performance.
Symbol indicates verified U-factor rating
in accordance with the DASMA Thermal
Performance Verification Program.