HomeMy WebLinkAbout21 Cutsheet Hollow Metal DoorsFrames • MU Series multi-use Book Rev. 09/26/24 • Page Rev. 11/01/22 • Technical data manual • • 33 MU Series multi-use About the product Steelcraft’s MU Series multi-use flush frames are designed for light to extra heavy duty applications in both commercial and institutional buildings. They can be installed in both interior and exterior locations, and in virtually all types of buildings and wall constructions. They have a jamb profile similar to the DW frames, but are designed to be installed as part of the wall framing sequence. They can be specified and/or supplied as either KD (knock-down) for field assembly prior to installation, or welded for installation as a complete unit. Installation1. Installation shall conform to the published Steelcraft installation instructions, ANSI A250.11-2012 Recommended Erection Instructions for Steel Frames and HMMA 840. 2. Fire Rated Assemblies must be in accordance with NFPA Pamphlet 80. The Authority Having Jurisdiction is the final authority in issues related to the installation and use of installed Fire Rated Doors. Features and benefitsSteelcraft MU Series multi-use flush frames offer the following unique features which enhance long-term functionality and durability. Features can vary depending on the steel thickness of the frame: 1. Die-mitered corner connections of the MU Series multi- use flush frame corners lock together once the frame is installed. The tab/lock design: a. prevents the head from rising b. keeps the head and jamb members in alignment c. keeps the miter tight d. includes wedge-lock corner clips. Screws are supplied to secure miter. 2. Patented universal hinge preparations allow for easy field conversion from standard weight .134" (3.3 mm) thick hinges to heavy weight 0.180" (4.7 mm) hinges. 3. Adjustable base anchors allow for installation adjustment when the floor is not level. 4. Factory prepared for field installed silencers. 5. Factory applied baked-on rust-inhibiting primer in accordance with ANSI A250.10-2011. Specification compliance 1. Overall frame construction for Steelcraft MU Series multi-use flush frames meet the requirements of ANSI A250.8-2017. 2. Hardware preparations and reinforcements are in accordance with ANSI A250.6. Locations are in accordance with ANSI/DHI A115 unless otherwise stated. Fire ratings MU Series multi-use flush frames meet the broadest fire rating requirements. They are listed for installations requiring compliance to both neutral pressure testing (ASTM E152 and UL 10B) and positive pressure standards (UL 10C). Refer to the Fire Rated Section of this manual for particular listings. Typical wall construction and anchoring types Profile Steel thickness Wall construction Typical wall anchors MU16 16 Gauge [0.053" (1.3 mm)]Wood or steel stud Lock-in stud anchor MU16 16 Gauge [0.053" (1.3 mm)]Masonry Wire masonry MU16 16 Gauge [0.053" (1.3 mm)]Existing Masonry Bolted through soffit MU14 14 Gauge [0.067" (1.7 mm)]Wood or steel stud Lock-in stud anchor MU14 14 Gauge [0.067" (1.7 mm)]Masonry Wire masonry MU14 14 Gauge [0.067" (1.7 mm)]Existing masonry Bolted through soffit Frames • MU Series multi-use 34 • • Technical data manual • Book Rev. 09/26/24 • Page Rev. 08/29/18 Standard construction Standard Double Rabbet Frame Single Rabbet Frame for frame depths 4 ⁄" and narrower Elevation 1 ⁄"(40 mm) Varies JambDepth ⁄" (16 mm) 1 ⁄"(49 mm) Opening Width2"(50 mm) ThroatOpening ½" (13 mm) ½" (13 mm) ⁄"(8 mm) 2"(50 mm)2"(50 mm) 2"(50 mm) 9 ¾"(248 mm) Equal Equal 10 ⁄"(264 mm) Finished Opening Height HINGE HINGE HINGE STRIKE Optional 14 gauge closer reinforcement Finished Opening Width 40 ⁄"(1024 mm) Jamb Depth 1 ⁄" (49 mm) Varies ⁄" (16 mm) Opening Width ⁄" ThroatOpening ½" (13 mm) ½" (13 mm) 2"(50 mm) Frame sizing options Series Maximum opening size Jamb depth availability(profile)Standard profile dimensions (variations available)Corners Single Pair Narrow double rabbet Double rabbet Face Stop Returns StandardMin. Max. Min. Max. MU16 4’0" x 9’0" (1219 mm x 2743 mm) 8'0" x 9'0" (2439 mm x 2743 mm) 3 1⁄4" (83 mm) 4 3⁄8" (111 mm) 4 1⁄2" (114 mm)20" (508 mm)2" (51 mm)5⁄8" (16 mm)1⁄2" (13 mm) DIE MITERED with interlocking Soffit tab MU14 4’0" x 9’0" (1219 mm x 2743 mm) 8'0" x 9'0" (2439 mm x 2743 mm) 3 1⁄4" (83 mm) 4 3⁄8" (111 mm) 4 1⁄2" (114 mm)20" (508 mm)2" (51 mm)5⁄8" (16 mm)1⁄2" (13 mm) DIE MITERED with interlocking Soffit tab Frames • MU Series multi-use Book Rev. 09/26/24 • Page Rev. 10/28/22 • Technical data manual • • 35 Standard hardware and corner conditions Universal Mortise Hinge Prep 4 7⁄8" (124 mm) Standard 5" (127 mm) Optional 7 Gauge Hinge Reinforcement 4 7/8" (124 mm) Strike Prep (ASA) 4 7⁄8 " (124 mm) Standard KD Corner Detail Optional 4" (102 mm) Head Detail Notes 1. Variations in jamb depths available in 1⁄8" (3 mm) increments. 2. All MU Series frames are supplied standard with masonry wire or lock-in jamb anchors and adjustable base anchors. Anchors are designed for maximum wall/frame engagement and installation flexibility. 3. MU Series frames are to be installed as part of the wall framing sequence. 4. Depending on environmental and usage conditions the steel can be either cold rolled or galvannealed. Galvannealed steel is recommended for all exterior applications. 5. MU Series with 4" heads are used mainly in masonry applications when 2" face heads do not match block coursing, or in drywall applications when installed in close proximity to a F Series or MU Series frame installed with a 4" head. Frame options Series Frame profile Corner connections 4" (102 mm) HeadsKD (Knock-down)SUA (Set-up & weld) Narrow double rabbet Double rabbet Single rabbet Double rabbet Single rabbet Double rabbet MU16 Typically for walls less than 3 3⁄4" (95 mm) thick. Minimum walls thickness = 2" (51 mm) Typically for walls 3 3⁄4 " (95 mm) thickness or greater. Factory Die-Mitered, Soffit Tab included. Corner clip assembly screws required. Available when specified, and in accordance with ANSI A250.8-2017. Die-mitered for use with 2" (51 mm) face jambs. Corner Clip assembly screws required.MU14 N/A - Not Available Frames • MU Series multi-use 36 • • Technical data manual • Book Rev. 09/26/24 • Page Rev. 10/28/22 Standard anchoring Wire Masonry Anchor 3⁄16" (5 mm) dia. wire Existing Masonry Anchor See note #6. Adjustable Base Anchor Attached with S. M. screws (furnished) Maximum adjustment 1 3⁄8" (35 mm) below frame Anchor for Stud Partition Lock-in anchor Anchoring and installation notes 1. MU16 Series Multi-use flush frames are supplied standard with masonry wire, or lock-in jamb anchors and adjustable base anchors. Anchors are designed for maximum wall/frame engagement, and installation flexibility. 2. For anchoring options (e.g. Masonry T anchors) and applications, refer to "Anchoring systems" on page 84. 3. Installation caution notice: Grouted frames: • When temperature conditions necessitate an additive to be used in the mortar to prevent freezing, the contractor installing the frames must coat the inside of frames in the filed with a corrosion resistant coating per A250.11 • When frames are to be grouted full, silencers must be field installed prior to grouting. • Steel frames, including fire rated frames, do not require grouting. Grouting is not recommended for frames in drywall. 4. Installation shall conform to the published Steelcraft installation instructions, A250.11 Recommended Installation Instructions for Steel Frames. 5. All fire rated frames must be installed in accordance with NFPA Pamphlet 80 and the Authority Having Jurisdiction. 6. When using Standard Exiting Wall Anchors the anchor must be field modified (notched) to provide clearance for the backbend return. Framing applications Series Steel type Building type Opening Usage frequency 1 KD Corner 4 SUA Corner 5 Applications MU16 Non-Galvannealed 2 Institutional and Commercial Interior Heavy to extra heavy duty   Typical building conditions Galvannealed 3 Mainly Exterior High humidity and/or weather exposure MU14 Non-Galvannealed 2 Institutional and Commercial Interior Extra heavy to maximum duty   Typical building conditions Galvannealed 3 Mainly Exterior High humidity and/or weather exposure 1 Usage frequency is based on ANSI A250.8-2017 2 Commercial quality carbon steel 3 Reinforcements for galvannealed frames are also galvannealed 4 Knock-Down for field assembly prior to installation 5 Set-up and Welded for installation as a pre-welded unit