HomeMy WebLinkAbout070-A2-PLANS BLDG A_HIGHLAND-A2.10ROOF PLAN
-
BUILDING B
SEE A0.2's, A0.3's, A4's FOR:
HORIZONTAL & VERTICAL ASSEMBLIES
ROOF TYPE ASSEMBLIES
X.X* = EXT. RIGID INSULATION IS ADDED
ASSEMBLIES LEGEND
R-#
FLOOR TYPE ASSEMBLIESF-#
EXTERIOR WALL TYPE ASSEMBLIESE-#
INTERIOR WALL TYPE ASSEMBLIESI-#
RA-#
FB-#
RADON ASSEMBLY
FIRE BLOCKING
SEE A0.0a FOR ALTERNATE NOTES.
ALTERNATE NOTE
SEE CODE PLANS AND SECITON FOR RATED FLOOR, CEILING AND
ROOF ASSEMBLIES.
CODE NOTE
DS
LINE OF WALL BELOW
GUTTER OVER FASCIA TO DOWNSPOUT. LOCATIONS ARE SHOWN GRAPHICALLY. EXACT
LOCATIONS TO BE VERIFIED WITH INSTALLER. DOWNSPOUTS TO CONNECT TO PVC PIPES IN
LANDSCAPE AREA AND TIE INTO DRAINAGE SYSTEM, SEE CIVIL. ENSURE PROPER SLOPES FOR
DRAINAGE. SEE CIVIL FOR DRAINAGE UNDER SLAB/SIDEWALK TO PROPERLY REMOVE ROOF
DRAINAGE OFF OF SIDEWALKS & TIE INTO STORM SEWER SYSTEM. SEE CIVIL AND SPEC.
2 HOUR RATED WALL
BELOW, SEE CODE PLANS 1:12 DIRECTION OF ROOF SLOPE
LINETYPE DESIGNATION
30 YEAR ASPHALT SHINGLES, INSTALL IN STRICT CONFORMANCE TO
MANUFACTURER INSTALLATION INSTRUCTIONS, SEE SPEC, VERIFY ALL CONDITIONS.
SEE DETAILS ON A8.3
CRICKETS, ROOFING CONTRACTOR TO FIELD VERIFY THICKNESS & SLOPE.
ROOF OUTLINE
GUTTER, SEE NOTE BELOW
METAL AWNING BELOW, SEE DETAILS ON A8.6 AND STRUCTURAL
SYMBOL DESIGNATION
ROOF TYPE - SEE A0.2 FOR
WALL ASSEMBLY
SECTION CUT
GRID LINE
EXTERIOR WALL - SEE A0.2 FOR
WALL ASSEMBLY, SEE
ELEVATIONS FOR SIDING TYPE
HATCH DESIGNATION
1
#
A#.#XXX
XXX
LEGEND - ROOF PLANS
R-#
E-#
DETAIL DRAWING
NUMBER
DETAIL SHEET NUMBER
NO PENETRATIONS IN ROOF ALLOWED WITHIN THIS AREA; 4-0" ON EACH
SIDE OF 2 HOUR WALL. SEE CODE WALL SECTION. G.C. TO FIELD VERIFY!20X30 ATTIC ACCESS, SEE DETAIL 1/A7.1c, COORDINATE WITH STRUCTURAL
DRAFT STOPPING IN HORIZONTAL ASSEMBLY BELOW IN LINE WITH WALL AS SHOWN, SEE
SECTIONS AND DETAILS FOR LOCATIONS WHERE DRAFTSTOPPING IS PROVIDED BY WALLS
CONTINUING INTO HORIZONTAL CAVITIES. SEE D-1 & D-2 ON A0.2
HINGED, SELF CLOSING ACCESS PANELS REQ'D THROUGH DRAFT STOPPING TO PROVIDE
EMERGENCY ACCESS TO ALL ATTIC SPACES.
OVERFRAMING, SEE STRUCTURAL DRAWINGS.
RIDGE VENT,
SEE DETAIL A8s
EXHAUST FAN FOR MECHANICALLY VENTED ATTIC,
SEE MECHANICAL & ELECTRICAL DRAWINGS
GENERAL NOTES - ROOF PLAN
A.GENERAL CONTRACTOR REQUIRED TO REFER TO ALL STRUCTURAL DETAILS IN SET & NOTIFY
ARCHITECT OF ANY DISCREPANCY.
B.SEE 5/A8.3 FOR ROOF PENETRATION DETAIL.
C.SEE MECHANICAL DRAWINGS FOR CEILING PENETRATIONS AND DUCT/PIPING INSULATION DETAILS.
D.PROJECT ROOF ASSEMBLY IS DESIGNED AS A WARM ROOF & ALL COMPONENTS ARE REQUIRED.
E.NOT USED
F.ALL ROOFS WITH A SLOPE OF 3:12 OR LESS, TO BE COVERED WITH ICE & WATER SHIELD IN ITS
ENTIRETY
G.NOT USED
H.ALL ROOF CRICKETS TO BE MINIMUM OF 1:12 SLOPE
I.PROVIDE CONCRETE SPLASH BLOCK AT EACH DOWNSPOUT, U.N.O. VERIFY COLOR WITH
ENCOMPASS.
J.ALL PLUMB & MECH VENTS TO BE GROUPED ORDERLY & NICELY ON ROOF, SPACE PER CODE
REQUIREMENTS & PAINTED, PER OWNER & ARCHITECT SELECTED COLOR.
KEYED NOTES - ROOF PLAN
AT RATED WALL, E-2 WALL ADJACENT SHALL ADD 5/8" EXTERIOR RATED GWB ON ENTIRE RUN OF WALL
FROM GRID 10 TO GRID 12 AND TO THE UNDERSIDE OF THE ROOF SHEATHING.1
CORAVENT "IN" VENT ABOVE THE SPRAY FOAM LOCATION. 1” X 6” TOTAL SLOT FOR THE "IN" VENT
LOCATIONS CENTERED EACH TRUSS BAY. INSTALL PER MANUF. REQUIREMENTS. SEE SECTIONS AND
DETAIL 5/A8.3a, TYP.
2
GUTTERS REQUIRED @ ALL
DOWNSLOPING ROOF EDGES. SEE 3/A8.3a
3
ATTIC ACCESS LOCATION - LOCKABLE WHEN
LOCATED WITH-IN UNIT, SEE DETAIL 1/A7.1c
4 30 YEAR ASPHALT SHINGLES, INSTALL PER MANUFACTURER REQUIREMENTS, TYP. SEE ASSEMBLIES ON A0.2
5
ROOF TO WALL FLASHING REQ'D PER
MANUFACTURER, SEE DETAIL 8/A8.3a.
6
SHINGLE OVER RIDGE VENT. SEE 4/A8.3a.
7
ROOF OVERHANG WITH WOOD BRACKET
AND BEAM, SEE 1/A8.3b & SEE STRUCTURAL.
8
COVER 3:12 ROOFS WITH ICE & WATER
SHIELD IN ITS ENTIRETY
9
HINGED, SELF CLOSING ACCESS PANELS REQ'D THROUGH DRAFT STOPPING TO PROVIDE EMERGENCY
ACCESS TO ALL ATTIC SPACES.
10
EXHAUST FAN FOR MECHANICALLY VENTED ATTIC,
SEE MECHANICAL & ELECTRICAL DRAWINGS11
12
13
PLUMBING VENTS, SEE MECH AND PLUMBING
DWGS. COORDINATE WITH STRUCTURAL IN FIELD.
SEE 6/A8.3a FOR ROOF PENETRATION TYP. DETAIL
DRAFTSTOPPING, SEE CODE PLANS
14 METAL AWNING - SEE 2/A8.3b AND SEE STRUCTURAL
A2.10
25.104edinc Job #:
1535 liberty lane
suite 110b
missoula, montana
59808
phone: 406.540.4437
design + architecture
inc
THIS SHEET IS INTENDED TO BE PRINTED IN
COLOR TO FULLY UNDERSTAND THE
INFORMATION BEING PRESENTED.
INFORMAL SET:SITE PLAN PACKET #2 - 10/24/20252025 ENCOMPASS DESIGN INC.C A NEW KAMAKA HOUSING DEVELOPMENT:HIGHLANDS APARTMENTSBOZEMAN, MONTANA05/09/25
SITE PLAN PACKET #1:08/01/25
SITE PLAN PACKET #2:10/24/25
SCALE :1 Roof Plan - Building B
3/32" = 1'-0"
N
8 9 10 12 14 15 16.5 20.8 21.8 24.5 2564321
1 2 3 4 6 8 9 10 12
15 16 17 18 1920 21 22 23 24 25 26
115
5 11
137
7 13 ABCEGIKNOPRSTVWABCEGHQHIKNOPQRSTVWMMXXLLDDFFJJUUCON
T
R
O
L
P
O
I
N
T
1
A4.1
E-2
E-2
E-2
I-G
E-2
I-G