HomeMy WebLinkAbout070-A2-PLANS BLDG A_HIGHLAND-A2.10ROOF PLAN - BUILDING B SEE A0.2's, A0.3's, A4's FOR: HORIZONTAL & VERTICAL ASSEMBLIES ROOF TYPE ASSEMBLIES X.X* = EXT. RIGID INSULATION IS ADDED ASSEMBLIES LEGEND R-# FLOOR TYPE ASSEMBLIESF-# EXTERIOR WALL TYPE ASSEMBLIESE-# INTERIOR WALL TYPE ASSEMBLIESI-# RA-# FB-# RADON ASSEMBLY FIRE BLOCKING SEE A0.0a FOR ALTERNATE NOTES. ALTERNATE NOTE SEE CODE PLANS AND SECITON FOR RATED FLOOR, CEILING AND ROOF ASSEMBLIES. CODE NOTE DS LINE OF WALL BELOW GUTTER OVER FASCIA TO DOWNSPOUT. LOCATIONS ARE SHOWN GRAPHICALLY. EXACT LOCATIONS TO BE VERIFIED WITH INSTALLER. DOWNSPOUTS TO CONNECT TO PVC PIPES IN LANDSCAPE AREA AND TIE INTO DRAINAGE SYSTEM, SEE CIVIL. ENSURE PROPER SLOPES FOR DRAINAGE. SEE CIVIL FOR DRAINAGE UNDER SLAB/SIDEWALK TO PROPERLY REMOVE ROOF DRAINAGE OFF OF SIDEWALKS & TIE INTO STORM SEWER SYSTEM. SEE CIVIL AND SPEC. 2 HOUR RATED WALL BELOW, SEE CODE PLANS 1:12 DIRECTION OF ROOF SLOPE LINETYPE DESIGNATION 30 YEAR ASPHALT SHINGLES, INSTALL IN STRICT CONFORMANCE TO MANUFACTURER INSTALLATION INSTRUCTIONS, SEE SPEC, VERIFY ALL CONDITIONS. SEE DETAILS ON A8.3 CRICKETS, ROOFING CONTRACTOR TO FIELD VERIFY THICKNESS & SLOPE. ROOF OUTLINE GUTTER, SEE NOTE BELOW METAL AWNING BELOW, SEE DETAILS ON A8.6 AND STRUCTURAL SYMBOL DESIGNATION ROOF TYPE - SEE A0.2 FOR WALL ASSEMBLY SECTION CUT GRID LINE EXTERIOR WALL - SEE A0.2 FOR WALL ASSEMBLY, SEE ELEVATIONS FOR SIDING TYPE HATCH DESIGNATION 1 # A#.#XXX XXX LEGEND - ROOF PLANS R-# E-# DETAIL DRAWING NUMBER DETAIL SHEET NUMBER NO PENETRATIONS IN ROOF ALLOWED WITHIN THIS AREA; 4-0" ON EACH SIDE OF 2 HOUR WALL. SEE CODE WALL SECTION. G.C. TO FIELD VERIFY!20X30 ATTIC ACCESS, SEE DETAIL 1/A7.1c, COORDINATE WITH STRUCTURAL DRAFT STOPPING IN HORIZONTAL ASSEMBLY BELOW IN LINE WITH WALL AS SHOWN, SEE SECTIONS AND DETAILS FOR LOCATIONS WHERE DRAFTSTOPPING IS PROVIDED BY WALLS CONTINUING INTO HORIZONTAL CAVITIES. SEE D-1 & D-2 ON A0.2 HINGED, SELF CLOSING ACCESS PANELS REQ'D THROUGH DRAFT STOPPING TO PROVIDE EMERGENCY ACCESS TO ALL ATTIC SPACES. OVERFRAMING, SEE STRUCTURAL DRAWINGS. RIDGE VENT, SEE DETAIL A8s EXHAUST FAN FOR MECHANICALLY VENTED ATTIC, SEE MECHANICAL & ELECTRICAL DRAWINGS GENERAL NOTES - ROOF PLAN A.GENERAL CONTRACTOR REQUIRED TO REFER TO ALL STRUCTURAL DETAILS IN SET & NOTIFY ARCHITECT OF ANY DISCREPANCY. B.SEE 5/A8.3 FOR ROOF PENETRATION DETAIL. C.SEE MECHANICAL DRAWINGS FOR CEILING PENETRATIONS AND DUCT/PIPING INSULATION DETAILS. D.PROJECT ROOF ASSEMBLY IS DESIGNED AS A WARM ROOF & ALL COMPONENTS ARE REQUIRED. E.NOT USED F.ALL ROOFS WITH A SLOPE OF 3:12 OR LESS, TO BE COVERED WITH ICE & WATER SHIELD IN ITS ENTIRETY G.NOT USED H.ALL ROOF CRICKETS TO BE MINIMUM OF 1:12 SLOPE I.PROVIDE CONCRETE SPLASH BLOCK AT EACH DOWNSPOUT, U.N.O. VERIFY COLOR WITH ENCOMPASS. J.ALL PLUMB & MECH VENTS TO BE GROUPED ORDERLY & NICELY ON ROOF, SPACE PER CODE REQUIREMENTS & PAINTED, PER OWNER & ARCHITECT SELECTED COLOR. KEYED NOTES - ROOF PLAN AT RATED WALL, E-2 WALL ADJACENT SHALL ADD 5/8" EXTERIOR RATED GWB ON ENTIRE RUN OF WALL FROM GRID 10 TO GRID 12 AND TO THE UNDERSIDE OF THE ROOF SHEATHING.1 CORAVENT "IN" VENT ABOVE THE SPRAY FOAM LOCATION. 1” X 6” TOTAL SLOT FOR THE "IN" VENT LOCATIONS CENTERED EACH TRUSS BAY. INSTALL PER MANUF. REQUIREMENTS. SEE SECTIONS AND DETAIL 5/A8.3a, TYP. 2 GUTTERS REQUIRED @ ALL DOWNSLOPING ROOF EDGES. SEE 3/A8.3a 3 ATTIC ACCESS LOCATION - LOCKABLE WHEN LOCATED WITH-IN UNIT, SEE DETAIL 1/A7.1c 4 30 YEAR ASPHALT SHINGLES, INSTALL PER MANUFACTURER REQUIREMENTS, TYP. SEE ASSEMBLIES ON A0.2 5 ROOF TO WALL FLASHING REQ'D PER MANUFACTURER, SEE DETAIL 8/A8.3a. 6 SHINGLE OVER RIDGE VENT. SEE 4/A8.3a. 7 ROOF OVERHANG WITH WOOD BRACKET AND BEAM, SEE 1/A8.3b & SEE STRUCTURAL. 8 COVER 3:12 ROOFS WITH ICE & WATER SHIELD IN ITS ENTIRETY 9 HINGED, SELF CLOSING ACCESS PANELS REQ'D THROUGH DRAFT STOPPING TO PROVIDE EMERGENCY ACCESS TO ALL ATTIC SPACES. 10 EXHAUST FAN FOR MECHANICALLY VENTED ATTIC, SEE MECHANICAL & ELECTRICAL DRAWINGS11 12 13 PLUMBING VENTS, SEE MECH AND PLUMBING DWGS. COORDINATE WITH STRUCTURAL IN FIELD. SEE 6/A8.3a FOR ROOF PENETRATION TYP. DETAIL DRAFTSTOPPING, SEE CODE PLANS 14 METAL AWNING - SEE 2/A8.3b AND SEE STRUCTURAL A2.10 25.104edinc Job #: 1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 design + architecture inc THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. INFORMAL SET:SITE PLAN PACKET #2 - 10/24/20252025 ENCOMPASS DESIGN INC.C A NEW KAMAKA HOUSING DEVELOPMENT:HIGHLANDS APARTMENTSBOZEMAN, MONTANA05/09/25 SITE PLAN PACKET #1:08/01/25 SITE PLAN PACKET #2:10/24/25 SCALE :1 Roof Plan - Building B 3/32" = 1'-0" N 8 9 10 12 14 15 16.5 20.8 21.8 24.5 2564321 1 2 3 4 6 8 9 10 12 15 16 17 18 1920 21 22 23 24 25 26 115 5 11 137 7 13 ABCEGIKNOPRSTVWABCEGHQHIKNOPQRSTVWMMXXLLDDFFJJUUCON T R O L P O I N T 1 A4.1 E-2 E-2 E-2 I-G E-2 I-G