HomeMy WebLinkAbout066-A2-PLANS BLDG A_HIGHLAND-A2.8aA2.8a
THIRD LEVEL
FLOOR PLAN
-
BUILDING B
TAGS
25.104edinc Job #:
1535 liberty lane
suite 110b
missoula, montana
59808
phone: 406.540.4437
design + architecture
inc
THIS SHEET IS INTENDED TO BE PRINTED IN
COLOR TO FULLY UNDERSTAND THE
INFORMATION BEING PRESENTED.
INFORMAL SET:SITE PLAN PACKET #2 - 10/24/20252025 ENCOMPASS DESIGN INC.C A NEW KAMAKA HOUSING DEVELOPMENT:HIGHLANDS APARTMENTSBOZEMAN, MONTANA05/09/25
SITE PLAN PACKET #1:08/01/25
SITE PLAN PACKET #2:10/24/25
SCALE :1 Third Level Floor Plan - Building B
3/32" = 1'-0"
N
8 9 10 12 14 15 16.5 20.8 21.8 24.5 2564321
1 2 3 4 6 8 9 10 12
15 16 17 18 1920 21 22 23 24 25 26
115
5 11
137
7 13 ABCEGIKNOPRSTVWABCEGHQHIKNOPQRSTVWMMXXLLDDFFJJUUCON
T
R
O
L
P
O
I
N
T
72240100ACCORDSHOWER STALLVIKRELL
72240100ACCORDSHOWER STALLVIKRELL
72240100ACCORDSHOWER STALLVIKRELL
72240100ACCORDSHOWER STALLVIKRELL
72240100ACCORDSHOWER STALLVIKRELL
72240100ACCORDSHOWER STALLVIKRELL
VIKRELLSHOWER STALLACCORD72240100
72240100ACCORDSHOWER STALLVIKRELL
72240100ACCORDSHOWER STALLVIKRELL
STAIR 1
S301
STAIR 2
S302
(U2-2 B)2 BDRM / 2 BATH
UNIT B304
(U2-2 B)2 BDRM / 2 BATH
UNIT B306
(U1-1 B)
1 BDRM / 1 BATH
UNIT B308
(U3-2 B)3 BDRM / 2 BATH
UNIT B301
(U2-2 B)2 BDRM / 2 BATH
UNIT B303
(U2-2 B)2 BDRM / 2 BATH
UNIT B305 (U1-1 B)1 BDRM / 1 BATH
UNIT B307
(U3-2 B)3 BDRM / 2 BATH
UNIT B309
(U2-2 B)
2 BDRM / 2 BATH
UNIT B316
(U2-2 B)
2 BDRM / 2 BATH
UNIT B314
(U3-2 B)
3 BDRM / 2 BATH
UNIT B318
(U2-2 B)
2 BDRM / 2 BATH
UNIT B315
(U2-2 B)
2 BDRM / 2 BATH
UNIT B313
(U3-2 B)
3 BDRM / 2 BATH
UNIT B317
(U2-2 B)
2 BDRM / 2 BATH
UNIT B310
(U1-1 B)
1 BDRM / 1 BATH
UNIT B311
(U1-1 B)
1 BDRM / 1 BATH
UNIT B312
CORRIDOR
C301
CORRIDOR
C306
CLOSET
JANITOR
C302
CORRIDOR
C305
CLOSET
MAINTENANCE
C303
CLOSET
MAINTENANCE
C304
(U3-2 ACC.)3 BDRM / 2 BATH
UNIT B302
30 MIN REQUIRED FIRE RATING
CEILING FAN, SEE ELECTRICAL
#
ALT
SEE COVER SHEET FOR
INFORMATION ON
ALTERNATE
CPT#RF FLOORING DESIGNATION,
SEE FINISH NOTES
LIGHTING, SEE ELECTRICAL
ROOM NAME
ROOM NUMBER
DOOR TAG - SEE SCHEDULE
ON A0.5
WINDOW TAG - SEE SCHEDULE
ON A0.5
INTERIOR WALL TYPES - SEE
A0.2 FOR WALL ASSEMBLY
SECTION CUT
GRID LINE GUARD RAIL, SEE DETAILS ON A8.4
EGRESS WINDOW, SEE WINDOW
SCHEDULE, NOTED ON CODE PLANS(E)
TEMPERED GLASS, SEE
WINDOW SCHEDULE(T)
EXTERIOR WALL - SEE A0.2 FOR
WALL ASSEMBLY, SEE
ELEVATIONS FOR SIDING TYPE
24" DEEP SHELF W/ CLOSET
ROD, SEE SPEC.
FD FLOOR DRAIN, SEE MECHANICAL
AND DETAIL 8/A7.1b
HATCH DESIGNATION
DOWN SPOUT, SEE ROOF PLANDS
HOSE BIB, SEE MECHANICALHB
CONCRETE
RAIN CHAIN, SEE ROOF PLANRC
1
#
A#.#
LANDSCAPING,
SEE CIVIL
AWNING BELOW, SEE
DETAILS ON A8.6 AND
STRUCTURAL
WOOD DECKING
NO ROOF PENETRATIONS
SEE CODE WALL SECTIONS
30 YEAR ARCHITECTURAL
ASPHALT SHINGLES - SEE
ARCH ROOF PLAN
XXX
XXX
LEGEND - FLOOR PLANS
I-#
X
ROOM2
ROOM1
RM#
N
XXX
S
W E
D-100
E-#
INTERIOR ELEVATION
NUMBER
SHEET NUMBER
DETAIL REFERENCE
LOCATION
DETAIL DRAWING
NUMBER
DETAIL SHEET NUMBER
CLOTHES WASHER & DRYER
LOCATIONS. PROVIDE EXHAUST
VENTING AS REQ'D BY MANUF.
DRYER: PROVIDE MIN 26 GA DUCT,
SEE MECHANICAL
WASHER: PROVIDE A FLOOR DRAIN
(BY CODE) AND PROVIDE HOOKUPS
(CSCI)
ELECTRICAL PANEL, SEE
ELECTRICAL
20X30 ATTIC ACCESS, SEE DETAIL
1/A7.1c, COORDINATE W/
STRUCTURAL
GENERAL NOTES -FLOOR PLANS
A.USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED,
CONSULT ENCOMPASS FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
B.DIMENSIONS ARE FROM FACE OF STUD AT NEW WALLS. SEE WALL TYPES FOR ADDITIONAL WALL
ASSEMBLY INFORMATION.
C.SET DOOR ROUGH OPENINGS 6" FROM F.O.S., TYP. U.N.O. CENTER CLOSET DOOR ALONG LENGTH OF
CLOSET.
D.SEE OVERALL PLANS FOR ADDITIONAL DIMENSIONS.
E.SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF BEARING & SHEAR WALLS.
F.COORDINATE ALL COLUMN LOCATIONS AND SIZES WITH STRUCTURAL DRAWINGS.
G.PROVIDE 2x6 BLOCKING FOR ALL CABINETRY, GRAB BARS, TOILET ACCESSORIES, TRAVERSE RODS,
ETC. BACKING TO BE INCLUDED IN ALL UNITS ON ALL FLOORS TO COMPLY WITH "ADA" ADAPTABILITY.
REFER TO INTERIOR ELEVATIONS FOR FURTHER INFORMATION REGARDING TOILET & TUB/SHOWER
BLOCKING, TYPICAL.
H.SEE RCP, ELECTRICAL & MECHANICAL PLANS FOR ALL SOFFIT LOCATIONS & DUCT RUNS & LIGHTING.
I.COORDINATE LIGHTING LAYOUT, SEE RCP AND ELECTRICAL DRAWINGS.
J.DASHED LINES AT DOORS, KITCHENS AND BATHROOMS INDICATE CODE REQUIRED CLEAR FLOOR
SPACE FOR ACCESSIBILITY. CONTRACTOR TO COORDINATE. SEE CODE PLANS.
K.WHERE RATED ASSEMBLIES ABUT OTHER ASSEMBLIES, CONTRACTOR TO PROVIDE ADDITIONAL
LAYERS OF SHEATHING, SOUND CHANNEL, GWB, ETC. TO PROVIDE A SMOOTH, UNIFORM FINISHED
SURFACE FOR ENTIRE LENGTH OF WALL.
L.SEE CODE SHEET FOR FURTHER REQUIREMENTS.
M.ALL EXPOSED STRUCTURE, HVAC, CONDUIT, ECT. TO BE PAINTED, VERIFY COLOR W/ OWNER.
N.GWB TO TRIM & FINISH AROUND BEAMS & JOISTS THAT PENETRATE ASSEMBLIES, TYP.
O.USE WATER RESISTANT GWB IN ALL WET ROOMS. (EI. BATHROOMS, LAUNDRY ROOMS, WATER
HEATER ROOMS, ETC). USE ADDITIONAL LAYERS OF GWB AS REQ'D TO NOT INTERRUPT RATINGS OF
WALLS.
P.SEE A5.1 & A5.2 FOR ALL ACCESSIBLE DETAILS & TYPICAL CASEWORK DIMENSIONS FOR THIS FLOOR.
Q.SHELF MOUNTING HEIGHTS TO BE MAX 48" A.F.F. IN THE CODE REQUIRED ADA ACCESSIBLE UNITS
AND 64" A.F.F. IN ALL OTHER UNITS. SEE ACCESSIBLE MOUNTING HEIGHTS ON A5's.
R.SEE A5's FOR BATHROOM AND KITCHEN INTERIOR ELEVATIONS.
S.SEE A7's FOR INTERIOR FLOOR BASE & FLOORING TRANSITION DETAILS.
T.SEE A7's FOR CEILING PENETRATIONS AND DUCT/PIPING INSULATION DETAILS.
U.SEE A8's FOR DOOR AND WINDOW DETAILS.
V.VERIFY ALL HARDWARE WITH OWNER, PROVIDE ALLOWANCES.
W.PROVIDE P.T. PLATES AT ALL WALLS ADJACENT TO CEMENTIOUS MATERIAL.
X.CONTRACTOR TO VERIFY IN EACH UNIT THAT THE CABINETRY LENGTH IS COORDINATED AND
VERIFIED WITH THE REFRIGERATOR REQUIRED CLEAR SPACE PER THE INSTALLATION INSTRUCTIONS.
Y.VERIFY BATHTUB/SHOWER HEAD WALL LOCATIONS WITH ARCH & MECH.
Z.FLOOR DRAIN REQUIRED AT ALL LAUNDRY NOOKS AND WATER HEATER CLOSETS. SEE MECH.
AA.PROVIDE GARBAGE DISPOSALS @ ALL KITCHEN SINKS.
AB.USE ¼” DURAROCK (OR APPROVED WATER RESISTANT CEMENT BOARD) IN ALL BATHROOMS,
LAUNDRY ROOMS AND WATER HEATER ROOMS. AT RATED COMMON WALLS BEHIND TUB OR SHOWER
INSERT PROVIDE 5/8" TYPE 'X' IN FULL, FIRE TAPE PRE TUB / SHOWER INSTALL.
AC.CARBON MONOXIDE DETECTORS REQUIRED IN EACH UNIT, COORDINATE WITH ELECTRICAL. SEE
SPECS.
AD.PORTABLE FIRE EXTINGUISHERS REQUIRED IN ALL UNITS & COMMUNITY ROOM. G.C. TO VERIFY TYPE
& SIZE W/ CITY AHJ & FINAL LOCATION WITH ARCHITECT.
SEE A0.2's, A0.3's, A4's FOR:
HORIZONTAL & VERTICAL ASSEMBLIES
ROOF TYPE ASSEMBLIES
X.X* = EXT. RIGID INSULATION IS ADDED
ASSEMBLIES LEGEND
R-#
FLOOR TYPE ASSEMBLIESF-#
EXTERIOR WALL TYPE ASSEMBLIESE-#
INTERIOR WALL TYPE ASSEMBLIESI-#
RA-#
FB-#
RADON ASSEMBLY
FIRE BLOCKING
SEE A0.0a FOR ALTERNATE NOTES.
ALTERNATE NOTE
SEE CODE PLANS AND SECITON FOR RATED FLOOR, CEILING AND
ROOF ASSEMBLIES.
CODE NOTE
SEE SPECIFICATIONS FOR PRODUCT INFORMATION
SPEC NOTE
SEE OVERALL BUILDING PLANS FOR WINDOWS.
SEE WINDOW SCHEDULE ON A0.5.X
WINDOW TYPES & SCHEDULE
NOT USED
KEYED NOTES - THIS SHEET ONLY
1
A
B
C
C
D
D
D
D
D
D
E
A
C
D
D
E
A
B
C
C
D
D
D
D
D
D
E
C
D
D
E
B
B
C
D
A
C
E
A
C
D
E
D
D
D
D
E
AC B C
D
DDBCE
D
D AC B CD
D
D
E
D
D
E
AC B C
D
D AC B CD
D
D
E
AB AB D
G
G
D
D
G
C301
C305
C306
C302
C303
C304
1
A4.1
E-2
E-2
E-2
I-G
E-2
I-G
I-A
I-A
I-BI-B
I-BI-B
I-A
I-A
I-A
I-A I-A
I-A
I-A
I-A
I-A
I-A
I-A
I-A
I-A
I-A
G
G G